Loic Schiesko
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Research Interests
Loic Schiesko has a total of 226 co-authors. Here are the top co-authors by number of shared publications:
- Ursel Fantz
Max-Planck-Institut für Plasmaphysik
28 shared publications - Dirk Wunderlich
Max-Planck-Institut für Plasmaphysik
17 shared publications - Christian Wimmer
Max-Planck-Institut für Plasmaphysik, Boltzmannstr. 2, 85748 Garching, Germany
14 shared publications B. Heinemann
Max-Planck-Institut für Plasmaphysik (IPP) 1 , Boltzmannstr. 2, 85748 Garching, Germany
10 shared publicationsP. Franzen
Max Planck Society
10 shared publicationsW. Kraus
9 shared publications
Latest Publications
- Open Access
- 24 November 2026
- Published by IOP Publishing in Plasma Sources Science and Technology
Measurement of the electron temperature in the channel of a Hall thruster using a xenon collisional-radiative model
In this work, radial and axial measurement of optical emission spectra from Hall thruster are analysed using a xenon collisional radiative model. The collisional radiative model includes transitions between the ground state, the 1s and the 2p states of the xenon atom due to electron impact excitation and de-excitation and radiative decay with an escape factor correction. The extraction of the plasma parameters relies on an optimisation loop that fits the 15 emission lines of the xenon atoms in the near-infrared range to the experimental ones and yields the effective electron temperature. The loop mainly constrains the effective electron temperature but it includes also the density of electrons and neutrals as fitting parameters. The predictions of the latter are considered only qualitatively. The model predictions of the effective electron temperature are benchmarked against Langmuir probe measurements in the plume region. The measurements are line-of-sight integrated and are performed at equally-spaced positions in the plume along the axial direction and in the channel along the radial direction. Measurements of the axial profile in the plume show a strong electron cooling and an exponential decrease of the electron density, linked to the plume expansion and the neutral background in the vacuum chamber. The measurements of the radial profile within the channel reveal, as expected, a hot core and a sharp decrease near the channel walls. A parametric study with the applied anode voltage and the mass flow rate demonstrate the capabilities and limitations of the method for non-invasive monitoring of the electron temperature in the thruster plume and the thruster channel.
- 24 November 2026
- Published by IOP Publishing in Plasma Sources Science and Technology
Open AccessMeasurement of the electron temperature in the channel of a Hall thruster using a xenon collisional-radiative model
In this work, radial and axial measurement of optical emission spectra from Hall thruster are analysed using a xenon collisional radiative model. The collisional radiative model includes transitions between the ground state, the 1s and the 2p states of the xenon atom due to electron impact excitation and de-excitation and radiative decay with an escape factor correction. The extraction of the plasma parameters relies on an optimisation loop that fits the 15 emission lines of the xenon atoms in the near-infrared range to the experimental ones and yields the effective electron temperature. The loop mainly constrains the effective electron temperature but it includes also the density of electrons and neutrals as fitting parameters. The predictions of the latter are considered only qualitatively. The model predictions of the effective electron temperature are benchmarked against Langmuir probe measurements in the plume region. The measurements are line-of-sight integrated and are performed at equally-spaced positions in the plume along the axial direction and in the channel along the radial direction. Measurements of the axial profile in the plume show a strong electron cooling and an exponential decrease of the electron density, linked to the plume expansion and the neutral background in the vacuum chamber. The measurements of the radial profile within the channel reveal, as expected, a hot core and a sharp decrease near the channel walls. A parametric study with the applied anode voltage and the mass flow rate demonstrate the capabilities and limitations of the method for non-invasive monitoring of the electron temperature in the thruster plume and the thruster channel.
- Open Access
- 2 April 2026
- Published by Oxford University Press (OUP) in Progress of Theoretical and Experimental Physics
- Vol. 2026 (5)
Influence of Short-Range Quantum Effects on Coulomb Collisions in Nondegenerate Plasmas
In this letter, a finite differential cross section is derived for Coulomb collisions in high-temperature nondegenerate plasmas using the first Born approximation with a short-range potential incorporating quantum screening and diffraction. The corresponding momentum-transfer cross section is also shown to acquire a nonnegligible contribution from small-angle collisions.
- 2 April 2026
- Published by Oxford University Press (OUP) in Progress of Theoretical and Experimental Physics
- Vol. 2026 (5)
Open AccessInfluence of Short-Range Quantum Effects on Coulomb Collisions in Nondegenerate Plasmas
In this letter, a finite differential cross section is derived for Coulomb collisions in high-temperature nondegenerate plasmas using the first Born approximation with a short-range potential incorporating quantum screening and diffraction. The corresponding momentum-transfer cross section is also shown to acquire a nonnegligible contribution from small-angle collisions.
- Open Access
- 24 December 2025
- Published by Oxford University Press (OUP) in Progress of Theoretical and Experimental Physics
- Vol. 2026 (2)
High-Temperature Quantum Regime and Emergent Short-Range Screening in Nondegenerate Plasmas
In nondegenerate, weakly coupled, fully ionized plasmas, microscopic quantum effects are often neglected in standard kinetic treatments. Here, we identify a high-temperature regime, elucidated and characterized by a hierarchy of length scales, in which short-range quantum screening and diffraction arise from the nonlocal electron response to the bare Coulomb field of a test charge. This quantum response yields a temperature- and density-dependent short-range screened potential, and we examine its consequences under conditions attained in magnetically confined fusion plasmas.
- 24 December 2025
- Published by Oxford University Press (OUP) in Progress of Theoretical and Experimental Physics
- Vol. 2026 (2)
Open AccessHigh-Temperature Quantum Regime and Emergent Short-Range Screening in Nondegenerate Plasmas
In nondegenerate, weakly coupled, fully ionized plasmas, microscopic quantum effects are often neglected in standard kinetic treatments. Here, we identify a high-temperature regime, elucidated and characterized by a hierarchy of length scales, in which short-range quantum screening and diffraction arise from the nonlocal electron response to the bare Coulomb field of a test charge. This quantum response yields a temperature- and density-dependent short-range screened potential, and we examine its consequences under conditions attained in magnetically confined fusion plasmas.
- Open Access
- 21 October 2024
- Published by AIP Publishing in Journal of Applied Physics
- Vol. 136 (15)
Analysis and control of Hall effect thruster using optical emission spectroscopy and artificial neural network
This study presents a proof-of-principle for using optical emission spectroscopy and artificial neural networks for real-time monitoring and control of the operational parameters of a Hall effect thruster: the anode voltage, the anode xenon injection, the discharge current, and the coil current. In that regard, we build an optical database of 26 spectral lines across 6469 operating conditions to train and test the neural network. We then reduced the learning lines from 26 to 15 based on their statistical correlation with the target parameters. After tuning the hyperparameters of the network, the network predicted the thruster’s parameters with notable accuracies: 95% for the anode voltage, 84% for the coil current, and 99% for both the anode flow rate and the discharge current. The estimated uncertainty of predictions, at 3σ, is ±51V for voltage, ±1A for coil current, ±0.15A for discharge current, and ±0.15mgs−1 for anode flow rate. The prediction calculations were within milliseconds and enabled real-time monitoring of the thruster parameters. Therefore, a proportional-integrator-derivative controller (PID) controller was implemented to regulate the anode voltage and flow rate based on the optical emission of the plume. The PID showcased short settling times from 0.1 to 0.4 s and overshoot levels up to 3% of the target value for the voltage and 10% of the target value for the flow rate. These results were for a fixed coil current at 4A. The study showed that changing the coil current may necessitate more sophisticated prediction models and control strategies. Future work will expand the model’s generalizability to different thruster types, propellants, and magnetic field configurations.
- 21 October 2024
- Published by AIP Publishing in Journal of Applied Physics
- Vol. 136 (15)
Open AccessAnalysis and control of Hall effect thruster using optical emission spectroscopy and artificial neural network
This study presents a proof-of-principle for using optical emission spectroscopy and artificial neural networks for real-time monitoring and control of the operational parameters of a Hall effect thruster: the anode voltage, the anode xenon injection, the discharge current, and the coil current. In that regard, we build an optical database of 26 spectral lines across 6469 operating conditions to train and test the neural network. We then reduced the learning lines from 26 to 15 based on their statistical correlation with the target parameters. After tuning the hyperparameters of the network, the network predicted the thruster’s parameters with notable accuracies: 95% for the anode voltage, 84% for the coil current, and 99% for both the anode flow rate and the discharge current. The estimated uncertainty of predictions, at 3σ, is ±51V for voltage, ±1A for coil current, ±0.15A for discharge current, and ±0.15mgs−1 for anode flow rate. The prediction calculations were within milliseconds and enabled real-time monitoring of the thruster parameters. Therefore, a proportional-integrator-derivative controller (PID) controller was implemented to regulate the anode voltage and flow rate based on the optical emission of the plume. The PID showcased short settling times from 0.1 to 0.4 s and overshoot levels up to 3% of the target value for the voltage and 10% of the target value for the flow rate. These results were for a fixed coil current at 4A. The study showed that changing the coil current may necessitate more sophisticated prediction models and control strategies. Future work will expand the model’s generalizability to different thruster types, propellants, and magnetic field configurations.
- Open Access
- 16 August 2023
- Published by AIP Publishing in Journal of Applied Physics
- Vol. 134 (7)
On the polytropic coefficient of negative ions for modeling the sheath and presheath of electronegative plasmas
The fluid description is widely used for the multi-dimensional modeling of low temperature plasmas with complex chemistries due to their relative low computational cost. It relies, however, on a series of simplifying assumptions and some truncation of the moment equations for describing the non-equilibrium between the electrons, positive ions, negative ions, and the neutrals. In this paper, the classical assumption of isothermal negative ions is revisited for electronegative plasmas and, more particularly, for the fluid modeling of the transition between the plasma and its sheath. To do so, and in contrast to previous studies, the energy balance equation for the negative ions is also computed, and it allows us to derive the polytropic coefficient γ of the negative ions in addition to one of the positive ions. Strong variations in the sheath and presheath of the negative ions temperature and their polytropic coefficient are observed. The polytropic coefficient is shown to be a strongly varying function of space having for consequence that the negative ions are isothermal only in a very narrow extension of the presheath. For the case considered in this paper, both positive and negative ion flows are nearly adiabatic at the sheath-edge and become adiabatic inside the sheath. This paper shows that classical fluid modeling assumptions need to be verified for each system under consideration, most particularly while modeling the transition from plasma to a wall.
- 16 August 2023
- Published by AIP Publishing in Journal of Applied Physics
- Vol. 134 (7)
Open AccessOn the polytropic coefficient of negative ions for modeling the sheath and presheath of electronegative plasmas
The fluid description is widely used for the multi-dimensional modeling of low temperature plasmas with complex chemistries due to their relative low computational cost. It relies, however, on a series of simplifying assumptions and some truncation of the moment equations for describing the non-equilibrium between the electrons, positive ions, negative ions, and the neutrals. In this paper, the classical assumption of isothermal negative ions is revisited for electronegative plasmas and, more particularly, for the fluid modeling of the transition between the plasma and its sheath. To do so, and in contrast to previous studies, the energy balance equation for the negative ions is also computed, and it allows us to derive the polytropic coefficient γ of the negative ions in addition to one of the positive ions. Strong variations in the sheath and presheath of the negative ions temperature and their polytropic coefficient are observed. The polytropic coefficient is shown to be a strongly varying function of space having for consequence that the negative ions are isothermal only in a very narrow extension of the presheath. For the case considered in this paper, both positive and negative ion flows are nearly adiabatic at the sheath-edge and become adiabatic inside the sheath. This paper shows that classical fluid modeling assumptions need to be verified for each system under consideration, most particularly while modeling the transition from plasma to a wall.
- 5 August 2022
- Published by AIP Publishing in Journal of Applied Physics
- Vol. 132 (5) , 054904
Saturation pressure of nonequilibrium titanium evaporation during additive manufacturing by electron powder bed fusion
Electron beam powder bed fusion (E-PBF) is an attractive technology for the additive manufacturing of metal parts. However, process improvements require precise control of the energy transferred to the powder by the electron beam. Here, we used tunable diode laser absorption spectroscopy (TD-LAS) to measure the velocity distribution functions of titanium atoms evaporated during E-PBF. The narrow spectral ranges emitted by laser diodes allow for high-resolution absorption profiles of the evaporated atoms and thus accurate determinations of their Doppler broadening, density, and temperature during melting. The obtained vapor temperature reveals overheating at the surface of the melt pool relative to the low-pressure (0.1 Pa) boiling point of titanium, indicating that evaporation occurs under nonequilibrium conditions. We characterized the influence of the linear energy density on titanium evaporation and found it to be consistent with the saturation vapor pressure. Our characterization of the vapor properties provides reliable inputs for melt pool simulations. Furthermore, TD-LAS may be further exploited to prevent the evaporation of low-concentration alloy elements, which can induce defects in the printed part.
- 5 August 2022
- Published by AIP Publishing in Journal of Applied Physics
- Vol. 132 (5) , 054904
Saturation pressure of nonequilibrium titanium evaporation during additive manufacturing by electron powder bed fusion
Electron beam powder bed fusion (E-PBF) is an attractive technology for the additive manufacturing of metal parts. However, process improvements require precise control of the energy transferred to the powder by the electron beam. Here, we used tunable diode laser absorption spectroscopy (TD-LAS) to measure the velocity distribution functions of titanium atoms evaporated during E-PBF. The narrow spectral ranges emitted by laser diodes allow for high-resolution absorption profiles of the evaporated atoms and thus accurate determinations of their Doppler broadening, density, and temperature during melting. The obtained vapor temperature reveals overheating at the surface of the melt pool relative to the low-pressure (0.1 Pa) boiling point of titanium, indicating that evaporation occurs under nonequilibrium conditions. We characterized the influence of the linear energy density on titanium evaporation and found it to be consistent with the saturation vapor pressure. Our characterization of the vapor properties provides reliable inputs for melt pool simulations. Furthermore, TD-LAS may be further exploited to prevent the evaporation of low-concentration alloy elements, which can induce defects in the printed part.
- 1 April 2022
- Published by IOP Publishing in Plasma Sources Science and Technology
- Vol. 31 (4) , 04LT01
On the use of ultra-high resolution PIC methods to unveil microscale effects of plasma kinetic instabilities: electron trapping and release by electrostatic tidal effect
Ultra-high resolution particle-in-cell coupled to Monte-Carlo collisions modelling unveils microscale instabilities in non-equilibrium plasmas fulfilling Penrose’s instability criterion. The spontaneous development of ion turbulence in the phase-space generated by charge exchange collisions leads to finite amplitude modulations of the local electric field. The latter are responsible for the trapping of low energy electrons and their transport from the plasma volume to the sheath vicinity. Electrostatic tidal effect occurring near the sheath is responsible for the release of the trapped electrons as a monochromatic bunch, accelerated back towards the source. This instability provides an additional theoretical ground for the anomalous enrichment of low-energy electrons observed by Langmuir probes in similar conditions. The present results demonstrate that marginally fulfilling PIC criteria is insufficient to study the microscale instabilities effects on the electrons dynamics in non-equilibrium low temperature plasmas.
- 1 April 2022
- Published by IOP Publishing in Plasma Sources Science and Technology
- Vol. 31 (4) , 04LT01
On the use of ultra-high resolution PIC methods to unveil microscale effects of plasma kinetic instabilities: electron trapping and release by electrostatic tidal effect
Ultra-high resolution particle-in-cell coupled to Monte-Carlo collisions modelling unveils microscale instabilities in non-equilibrium plasmas fulfilling Penrose’s instability criterion. The spontaneous development of ion turbulence in the phase-space generated by charge exchange collisions leads to finite amplitude modulations of the local electric field. The latter are responsible for the trapping of low energy electrons and their transport from the plasma volume to the sheath vicinity. Electrostatic tidal effect occurring near the sheath is responsible for the release of the trapped electrons as a monochromatic bunch, accelerated back towards the source. This instability provides an additional theoretical ground for the anomalous enrichment of low-energy electrons observed by Langmuir probes in similar conditions. The present results demonstrate that marginally fulfilling PIC criteria is insufficient to study the microscale instabilities effects on the electrons dynamics in non-equilibrium low temperature plasmas.
- 1 April 2021
- Published by Oxford University Press (OUP) in Europhysics Letters
- Vol. 134 (1)
Surface and sub-surface investigations of the plasma influence on Cs doped Mo as surface converter for negative hydrogen ion sources for fusion(a)
The influence of low-pressure and low-temperature hydrogen plasma on a pure molybdenum sample implanted with caesium is investigated by means of sputtering-XPS. A portion of the sample was exposed to the plasma, while the rest of the sample was covered by stainless steel and thus shielded from direct plasma flux. The results show that the part of the sample exposed to the plasma exhibits both on and beneath the surface an increased amount of H 2 O and MoO 2 with respect to the covered sample part which can be explained by a chemical reduction of MoO 3 oxides by the hydrogen plasma species. The XPS Cs lines show oxidation peaks. A sputtering depth of roughly 13 nm is necessary to recover an identical spectrum, indicating that the plasma changes the chemical composition of the implanted samples not only on the surface but also inside the material.
- 1 April 2021
- Published by Oxford University Press (OUP) in Europhysics Letters
- Vol. 134 (1)
Surface and sub-surface investigations of the plasma influence on Cs doped Mo as surface converter for negative hydrogen ion sources for fusion(a)
The influence of low-pressure and low-temperature hydrogen plasma on a pure molybdenum sample implanted with caesium is investigated by means of sputtering-XPS. A portion of the sample was exposed to the plasma, while the rest of the sample was covered by stainless steel and thus shielded from direct plasma flux. The results show that the part of the sample exposed to the plasma exhibits both on and beneath the surface an increased amount of H 2 O and MoO 2 with respect to the covered sample part which can be explained by a chemical reduction of MoO 3 oxides by the hydrogen plasma species. The XPS Cs lines show oxidation peaks. A sputtering depth of roughly 13 nm is necessary to recover an identical spectrum, indicating that the plasma changes the chemical composition of the implanted samples not only on the surface but also inside the material.
- Open Access
- 1 February 2021
- Published by AIP Publishing in AIP Advances
- Vol. 11 (2) , 025330
First direct comparison of whole beam and single beamlet divergences in a negative ion source with simultaneous BES and CFC tile calorimetry measurements
Neutral beam injection (NBI) systems are required for heating and current drive in the next generation fusion experiment ITER, and strict requirements are placed on the beamlet core divergence (<7 mrad) for transmission into the tokamak. The measurement of single beamlet divergence is challenging due to the multi-beamlet nature of the negative ion sources that are required for such systems; diagnostic systems compatible with large high power ion beams can only provide spatially averaged measurements, leading to mixing of beamlet signals within diagnostic results. To improve the understanding of this effect, a direct comparison has been made between the single beamlet and multi-beamlet divergence by a combination of both Beam Emission Spectroscopy (BES) and 1D carbon fiber composite tile calorimetry, in a joint campaign by IPP and Consorzio RFX. The measurements performed so far in this campaign at the BATMAN Upgrade Test Facility have led to two major results. First, an excellent agreement is found for single beamlet divergences from the two diagnostics, showing that the results from these diagnostic systems can be compared for single beamlets. Second, the contribution of beamlet deflection, caused by an alternating magnetic field at the extract grid, to the divergence as measured using BES has been quantified with up to a factor of 3 increase when compared with the single beamlet value. This demonstrates that further investigation is needed into how mixing of information from a beamlet affects diagnostic results with a combination of both simulation and experiment, which will be performed in a next step.
- 1 February 2021
- Published by AIP Publishing in AIP Advances
- Vol. 11 (2) , 025330
Open AccessFirst direct comparison of whole beam and single beamlet divergences in a negative ion source with simultaneous BES and CFC tile calorimetry measurements
Neutral beam injection (NBI) systems are required for heating and current drive in the next generation fusion experiment ITER, and strict requirements are placed on the beamlet core divergence (<7 mrad) for transmission into the tokamak. The measurement of single beamlet divergence is challenging due to the multi-beamlet nature of the negative ion sources that are required for such systems; diagnostic systems compatible with large high power ion beams can only provide spatially averaged measurements, leading to mixing of beamlet signals within diagnostic results. To improve the understanding of this effect, a direct comparison has been made between the single beamlet and multi-beamlet divergence by a combination of both Beam Emission Spectroscopy (BES) and 1D carbon fiber composite tile calorimetry, in a joint campaign by IPP and Consorzio RFX. The measurements performed so far in this campaign at the BATMAN Upgrade Test Facility have led to two major results. First, an excellent agreement is found for single beamlet divergences from the two diagnostics, showing that the results from these diagnostic systems can be compared for single beamlets. Second, the contribution of beamlet deflection, caused by an alternating magnetic field at the extract grid, to the divergence as measured using BES has been quantified with up to a factor of 3 increase when compared with the single beamlet value. This demonstrates that further investigation is needed into how mixing of information from a beamlet affects diagnostic results with a combination of both simulation and experiment, which will be performed in a next step.
- Open Access
- 17 January 2020
- Published by AIP Publishing in Journal of Applied Physics
- Vol. 127 (3) , 033302
Kinetic sheath in presence of multiple positive ions, negative ions, and particle wall emission
The region between a Maxwellian plasma source and a floating or current-carrying surface is described by a static, one-dimensional collisionless kinetic sheath model. In the plasma source, electrons, negative ions, and several positive ion species with different temperatures can be included. The surface (wall) can emit electrons and/or negative ions. When the flux of surface-emitted negative ions and/or electrons reaches a critical value, the sheath becomes space-charge saturated, which leads to the formation of a virtual cathode in front of the emitting wall and sets the maximum current density that can be transported from the surface to the plasma. The analytical results are benchmarked against a particle-in-cell code.
- 17 January 2020
- Published by AIP Publishing in Journal of Applied Physics
- Vol. 127 (3) , 033302
Open AccessKinetic sheath in presence of multiple positive ions, negative ions, and particle wall emission
The region between a Maxwellian plasma source and a floating or current-carrying surface is described by a static, one-dimensional collisionless kinetic sheath model. In the plasma source, electrons, negative ions, and several positive ion species with different temperatures can be included. The surface (wall) can emit electrons and/or negative ions. When the flux of surface-emitted negative ions and/or electrons reaches a critical value, the sheath becomes space-charge saturated, which leads to the formation of a virtual cathode in front of the emitting wall and sets the maximum current density that can be transported from the surface to the plasma. The analytical results are benchmarked against a particle-in-cell code.