SRShreyas Rangan

Shreyas Rangan

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Shreyas Rangan has a total of 16 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • EXPRESS: Data Adequacy Testing for Partial Least Squares Discriminant Analysis Using Raman Spectra

    by H. Georg Schulze, Rupa Haldavekar, Shreyas Rangan, Smilla Colombini, Michael W. Blades, Robin F. B. Turner, James M. Piret

    Partial least squares discriminant analysis (PLS-DA) is often used for data sets that consist of a large number of potential predictors but relatively few observations such that chance correlations between predictors and response can occur that lead to false conclusions. Hence, there is a need for data adequacy testing before model building but currently no such method exists. In this work we propose one where we used random permutations to destroy the correlation structure between predictor and response data. This produced normal distributions of chance correlation coefficients that were used to find correlation coefficients in the non-permuted data that differed significantly from chance occurrences. Based on these distributions, we defined two novel null hypotheses to control for when a true null hypothesis is incorrectly rejected and the other for when a false null hypothesis is not rejected. To counter false positive errors, the standard significance levels were adjusted with predictor-based Bonferroni corrections. To counter false negative errors, we compared the true and permuted correlation coefficients in distribution tails. The outcomes of the hypothesis tests then indicated whether or not PLS-DA models could be successfully built from these data sets. We also investigated how to determine the number of samples needed for a data set with a given number of predictors. Simulations showed that our method produced significantly fewer false positives than PLS-DA ( P = 0.0018, our method error rate 12× less than PLS-DA error rate) but significantly more false negatives ( P = 0.0003, our method error rate 4.5× more than PLS-DA error rate). Data from Raman spectroscopy showed that the method transferred to real data. By pre-screening such data, our method can aid in assessing whether to proceed with model building and, when there is a need to increase the sample size, we show by how much.

  • Open Access

    Demixing and Analysis of Complex Biological Raman Hyperspectra Based on Peak Fitting, Amplitude Trend Clustering, and Spectrum Reconstruction

    by H. Georg Schulze, Shreyas Rangan, Martha Z. Vardaki, Michael W. Blades, Robin F. B. Turner, James M. Piret

    To better interpret the Raman spectra from mammalian cells, it is often desirable to reduce their complexity by decomposing them into the spectral contributions from individual macromolecules or types of macromolecules. Diverse methods exist for demixing complex spectra, each with different benefits and drawbacks. However, some methods require a library of component spectra that might not be available, while others are hampered by noise and peak congestion that includes many proximal overlapping peaks. Through rapid fitting of individual peaks in every spectrum of a Raman hyperspectral data set, we have obtained individual peak parameters from which we determined the trends for all the peak amplitudes. We then grouped similar trends with k -means clustering. Then we used the peak parameters of all the peaks in a given cluster to reconstruct a spectrum representative of that cluster. This method produced spectra that were less distorted by unrelated overlapping peaks or noise, were less congested than those in the hyperspectral set, and thereby improved peak identification and macromolecule recognition. We have demonstrated the application of the method with Raman spectra from a perchlorate–polystyrene model system and extended it to complex spectra from methanol-fixed mammalian cells. We were able to recover independent spectra of perchlorate and polystyrene in the model system and spectra pertaining to individual macromolecular types (proteins, nucleic acids, lipids) from the mammalian cell data. We discuss how imperfections in spectral preprocessing and peak fitting can adversely affect the results. In summary, we have provided a proof-of-concept for a novel mixture resolution method with different attributes than extant ones.


  • Open Access

    Rapid Vector-Based Peak Fitting and Resolution Enhancement for Correlation Analyses of Raman Hyperspectra

    by H. Georg Schulze, Shreyas Rangan, Martha Z. Vardaki, Michael W. Blades, Robin F. B. Turner, James M. Piret

    Spectroscopic peak parameters are important since they provide information about the analyte under study. Besides obtaining these parameters, peak fitting also resolves overlapped peaks. Thus, the obtained parameters should permit the construction of a higher-resolution version of the original spectrum. However, peak fitting is not an easy task due to computational reasons and because the true nature of the analyte is often unknown. These difficulties are major impediments when large hyperspectral data sets need to be processed rapidly, such as for manufacturing process control. We have developed a novel and relatively fast two-part algorithm to perform peak fitting and resolution enhancement on such data sets. In the first part of the algorithm, estimates of the total number of bands and their parameters were obtained from a representative spectrum in the data set, using a combination of techniques. Starting with these parameter estimates, all the spectra were then iteratively and rapidly fitted with Gaussian bands, exploiting intrinsic features of the Gaussian distribution with vector operations. The best fits for each spectrum were retained. By reducing the obtained bandwidths and commensurately increasing their amplitudes, high-resolution spectra were constructed that greatly improved correlation-based analyses. We tested the performance of the algorithm on synthetic spectra to confirm that this method could recover the ground truth correlations between highly overlapped peaks. To assess effective peak resolution, the method was applied to low-resolution spectra of glucose and compared to results from high-resolution spectra. We then processed a larger spectral data set from mammalian cells, fixed with methanol or air drying, to demonstrate the resolution enhancement of the algorithm on complex spectra and the effects of resolution-enhanced spectra on two-dimensional correlation spectroscopy and principal component analyses. The results indicated that the algorithm would allow users to obtain high-resolution spectra relatively fast and permit the recovery of important aspects of the data's intrinsic correlation structure.


  • Open Access

    Saline dry fixation for improved cell composition analysis using Raman spectroscopy

    by Shreyas Rangan, Riley Wong, H. Georg Schulze, Martha Z. Vardaki, Michael W. Blades, Robin F. B. Turner, James M. Piret

    Raman spectroscopy enables the label-free assessment of cellular composition. While live cell analysis is the most accurate approach for cellular Raman spectroscopy, the analysis of fixed cells has proved to be very useful, particularly in collaborative projects where samples need to be serially examined by different laboratories or stored and reanalyzed at a later date. However, many chemicals that are widely used for cell fixation directly affect cellular biomolecules, yielding Raman spectra with missing or altered information. In this article, we compared the suitability of dry-fixation with saline versus chemical fixatives. We compared the Raman spectroscopy of saline dry-fixed cells with the more commonly used formaldehyde and methanol fixation and found that dry-fixed cell spectra preserved more cellular information than either chemical fixative. We also assessed the stability of dry-fixed cells over time and found that they were stable for at least 5 months. Finally, a comparison of dry-fixed and live cell spectra revealed effects due to the hydration state of the cells since they were recovered upon rehydrating dry-fixed samples. Thus, for fixed cell Raman spectroscopy, we recommend dry-fixation with unbuffered saline as a superior method to formaldehyde or methanol fixation.


  • Open Access

    Two-Dimensional Clustering of Spectral Changes for the Interpretation of Raman Hyperspectra

    by H. Georg Schulze, Shreyas Rangan, Martha Z. Vardaki, Michael W. Blades, Robin F. B. Turner, James M. Piret

    Two-dimensional correlation spectroscopy (2D-COS) is a technique that permits the examination of synchronous and asynchronous changes present in hyperspectral data. It produces two-dimensional correlation coefficient maps that represent the mutually correlated changes occurring at all Raman wavenumbers during an implemented perturbation. To focus our analysis on clusters of wavenumbers that tend to change together, we apply a k-means clustering to the wavenumber profiles in the perturbation domain decomposition of the two-dimensional correlation coefficient map. These profiles (or trends) reflect peak intensity changes as a function of the perturbation. We then plot the co-occurrences of cluster members two-dimensionally in a manner analogous to a two-dimensional correlation coefficient map. Because wavenumber profiles are clustered based on their similarity, two-dimensional cluster member spectra reveal which Raman peaks change in a similar manner, rather than how much they are correlated. Furthermore, clustering produces a discrete partitioning of the wavenumbers, thus a two-dimensional cluster member spectrum exhibits a discrete presentation of related Raman peaks as opposed to the more continuous representations in a two-dimensional correlation coefficient map. We demonstrate first the basic principles of the technique with the aid of synthetic data. We then apply it to Raman spectra obtained from a polystyrene perchlorate model system followed by Raman spectra from mammalian cells fixed with different percentages of methanol. Both data sets were designed to produce differential changes in sample components. In both cases, all the peaks pertaining to a given component should then change in a similar manner. We observed that component-based profile clustering did occur for polystyrene and perchlorate in the model system and lipids, nucleic acids, and proteins in the mammalian cell example. This confirmed that the method can translate to “real world” samples. We contrast these results with two-dimensional correlation spectroscopy results. To supplement interpretation, we present the cluster-segmented mean spectrum of the hyperspectral data. Overall, this technique is expected to be a valuable adjunct to two-dimensional correlation spectroscopy to further facilitate hyperspectral data interpretation and analysis.


  • Open Access

    Critical Evaluation of Spectral Resolution Enhancement Methods for Raman Hyperspectra

    by H. Georg Schulze, Shreyas Rangan, Martha Z. Vardaki, Michael W. Blades, Robin F. B. Turner, James M. Piret

    Overlapping peaks in Raman spectra complicate the presentation, interpretation, and analyses of complex samples. This is particularly problematic for methods dependent on sparsity such as multivariate curve resolution and other spectral demixing as well as for two-dimensional correlation spectroscopy (2D-COS), multisource correlation analysis, and principal component analysis. Though software-based resolution enhancement methods can be used to counter such problems, their performances often differ, thereby rendering some more suitable than others for specific tasks. Furthermore, there is a need for automated methods to apply to large numbers of varied hyperspectral data sets containing multiple overlapping peaks, and thus methods ideally suitable for diverse tasks. To investigate these issues, we implemented three novel resolution enhancement methods based on pseudospectra, over-deconvolution, and peak fitting to evaluate them along with three extant methods: node narrowing, blind deconvolution, and the general-purpose peak fitting program Fityk. We first applied the methods to varied synthetic spectra, each consisting of nine overlapping Voigt profile peaks. Improved spectral resolution was evaluated based on several criteria including the separation of overlapping peaks and the preservation of true peak intensities in resolution-enhanced spectra. We then investigated the efficacy of these methods to improve the resolution of measured Raman spectra. High resolution spectra of glucose acquired with a narrow spectrometer slit were compared to ones using a wide slit that degraded the spectral resolution. We also determined the effects of the different resolution enhancement methods on 2D-COS and on chemical contrast image generation from mammalian cell spectra. We conclude with a discussion of the particular benefits, drawbacks, and potential of these methods. Our efforts provided insight into the need for effective resolution enhancement approaches, the feasibility of these methods for automation, the nature of the problems currently limiting their use, and in particular those aspects that need improvement.


  • Augmented Two-Dimensional Correlation Spectroscopy for the Joint Analysis of Correlated Changes in Spectroscopic and Disparate Sources

    by H. Georg Schulze, Shreyas Rangan, Martha Z. Vardaki, Diepiriye G. Iworima, Timothy J. Kieffer, Michael W. Blades, Robin F. B. Turner, James M. Piret

    Here, we present an augmented form of two-dimensional correlation spectroscopy, that integrates in a single format data from spectroscopic and multiple non-spectroscopic sources for analysis. The integration is affected by augmenting every spectrum in a hyperspectral data set with relevant non-spectroscopic data to permit two-dimensional correlation analysis (2D-COS) of the ensemble of augmented spectra. A k-means clustering is then applied to the results of the perturbation domain decomposition to determine which Raman peaks cluster with any of the non-spectroscopic data. We introduce and explain the method with the aid of synthetic spectra and synthetic non-spectroscopic data. We then demonstrate this approach with data using Raman spectra from human embryonic stem cell aggregates undergoing directed differentiation toward pancreatic endocrine cells and parallel bioassays of hormone mRNA expression and C-peptide levels in spent medium. These pancreatic endocrine cells generally contain insulin or glucagon. Insulin has disulfide bonds that produce Raman scattering near 513 cm –1 , but no tryptophan. For insulin-positive cells, we found that the application of multisource correlation analysis revealed a high correlation between insulin mRNA and Raman scattering in the disulfide region. In contrast, glucagon has no disulfide bonds but does contain tryptophan. For glucagon-positive cells, we also observed a high correlation between glucagon mRNA and tryptophan Raman scattering (∼757 cm –1 ). We conclude with a discussion of methods to enhance spectral resolution and its effects on the performance of multisource correlation analysis.


  • Applications of Raman spectroscopy in the development of cell therapies: state of the art and future perspectives

    by Shreyas Rangan, H. Georg Schulze, Martha Z. Vardaki, Michael W. Blades, James M. Piret, Robin F. B. Turner

    This comprehensive review article discusses current and future perspectives of Raman spectroscopy-based analyses of cell therapy processes and products.


  • Smoothing Raman Spectra with Contiguous Single-Channel Fitting of Voigt Distributions: An Automated, High-Quality Procedure

    by H. Georg Schulze, Shreyas Rangan, Michael W. Blades, James M. Piret, Robin F. B. Turner

    Theoretical probability distributions are often fitted to the individual peaks of Raman spectra to decompose them and facilitate further analyses. Fitting has the additional advantage of eliminating noise. We have exploited this noise-eliminating attribute of fitting procedures in an automated algorithm to smooth Raman spectra. An initial smoothing was performed by fitting Voigt distributions to every channel in a spectrum. The Voigt distribution characters used were strongly Gaussian, the distribution widths equal to the spectral resolution, and their initial amplitudes equal to the spectral intensities at the channels where they were located. The smoothed spectrum was then subtracted from the original noisy spectrum to obtain a residual. For channels where the residual exceeded a limit-of-detection threshold, the distribution width was decreased. The fitting was then repeated until a secondary, lower limit distribution width was reached. The residual was then smoothed repeatedly in the same manner until the minimum distribution width was reached. After each repetition, the smoothed residual was added to the smoothed spectrum. The process was continued until a combined limit of detection and chi-squared stopping criterion was reached. Although slower in comparison to spline- and Savitzky–Golay-based methods, the smoothing quality was significantly better allowing the majority of smoothed spectra, in contrast to these methods, to pass a stringent smoothing quality test.


  • Developing Fully Automated Quality Control Methods for Preprocessing Raman Spectra of Biomedical and Biological Samples

    by H. Georg Schulze, Shreyas Rangan, James M. Piret, Michael W. Blades, Robin F. B. Turner

    Spectral preprocessing is frequently required to render Raman spectra useful for further processing and analyses. The various preprocessing steps, individually and sequentially, are increasingly being automated to cope with large volumes of data from, for example, hyperspectral imaging studies. Full automation of preprocessing is especially desirable when it produces consistent results and requires minimal user input. It is therefore essential to evaluate the “quality” of such preprocessed spectra. However, relatively few methods exist to evaluate preprocessing quality, and fully automated methods for doing so are virtually non-existent. Here we provide a brief overview of fully automated spectral preprocessing and fully automated quality assessment of preprocessed spectra. We follow this with the introduction of fully automated methods to establish figures-of-merit that encapsulate preprocessing quality. By way of illustration, these quantitative methods are applied to simulated and real Raman spectra. Quality factor and quality parameter figures-of-merit resulting from individual preprocessing step quality tests, as well as overall figures-of-merit, were found to be consistent with the quality of preprocessed spectra.