KHKas J. Houthuijs

Kas J. Houthuijs

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Kas J. Houthuijs has a total of 125 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Data-Driven Filter for Detector Oscillation Artifacts in Time-of-Flight Mass Spectrometry

    by Kas J. Houthuijs, Karl J. Jobst, Frederic Béen

    Time-of-flight mass spectrometry (TOF-MS) is widely used for complex mixture analysis due to its ability to detect thousands of chemical compounds in a single sample. However, high-intensity ions can saturate the detector and generate artifacts, commonly referred to as “detector ringing”. These artifacts resemble true MS features and often persist after componentization, complicating data interpretation and feature prioritization. Here, we introduce a data-driven filtering approach that exploits the time-domain origin of detector ringing to remove such artifacts. Because ion flight times scale with m/z, oscillations in the detector response manifest as artifactual features with constant delays in m/z, providing a universal detection criterion independent of ion source conditions and chromatographic or ion mobility separation. The workflow was evaluated on GC-, LC-, and ion mobility-hyphenated TOF-MS datasets from multiple instrumental platforms, identifying and removing up to 5.3% of features. Comparison across instruments revealed that Δm/z spacings are not only constant but also instrument-specific and polarity-independent, suggesting potential applications in data forensics and traceability. To assess broader relevance, the filter was applied to the MassBank and NIST DART-MS Forensics fragmentation mass spectral libraries. Although the overall incidence was low relative to library size (1.7%), over 1000 mass spectra were provisionally identified as containing ringing artifacts. Clustering these spectra by their Δm/z effectively partitioned the data by TOF-MS platform, revealing distinct groupings across libraries and contributors. By specifically targeting detector-derived artifacts, this workflow reduces false positives and improves feature prioritization and compound identification, enhancing the robustness of TOF-MS-based chemical analyses.


  • Top Cited Papers

    Health impacts of microplastic and nanoplastic exposure

    by Marja H. Lamoree, Jeske van Boxel, Federica Nardella, Kas J. Houthuijs, Sicco H. Brandsma, Frederic Béen, Majorie B. M. van Duursen

    As evidence demonstrating the presence of micro- and nanoplastics (MNPs) in the human body accumulates, so do concerns about their potential health impacts. Multiple factors determine the properties and behavior of MNPs—including polymer type, size, shape and the presence of a biocorona, among others—which place high demands on analytical methodology and tools for assessment of potential adverse health effects. Experimental models have shown that MNPs can cross cell barriers in the human lung and intestine and reach systemic circulation and subsequently tissues such as reproductive organs, placenta and brain. Early clinical findings indicate that MNPs may be associated with adverse health outcomes, including immune modulation, reproductive effects and cardiovascular effects. However, these studies typically suffer from low patient numbers and inadequate MNP exposure assessment, which precludes adequate risk assessment. Still, outcomes from animal and cell-based analyses generally support the preliminary clinical findings. To conduct more robust human studies, maturation of methods for exposure and effect assessment are crucial. Addressing these challenges will improve scientific research on the health impact of MNPs, which is urgently needed.


  • Open Access

    Identification of micro-/nanoplastics in human placental blood using comprehensive multidimensional pyrolysis - gas chromatography x ion mobility mass spectrometry

    by Justine R. Bissonnette, Nikita E. Harvey, Mikela L. Rowsell, Sophie Kiefte, Kas J. Houthuijs, Frederic M. Béen, Marja H. Lamoree, Lindsay S. Cahill, Karl J. Jobst


  • Open Access

    Structure Elucidation for MALDI Mass Spectrometry Imaging Using Infrared Ion Spectroscopy

    by Jelle L. Schuurman, Lara van Tetering, Kas J. Houthuijs, Pieter Kooijman, Valerie Gailus-Durner, Stefanie Leuchtenberger, Helmut Fuchs, Martin Hrabe de Angelis, Udo F. H. Engelke, Dirk J. Lefeber, et al.

    Infrared ion spectroscopy (IRIS) is a tandem mass spectrometry (MS) technique that generates structurally diagnostic vibrational spectra for mass-selected ions trapped in a mass spectrometer. Until now, IRIS applications for biological samples have primarily focused on solution-based analyses, such as body fluids (e.g., plasma and urine) and tissue homogenates, using electrospray ionization (ESI) coupled with liquid chromatography-mass spectrometry (LC-MS). In this study, we have combined matrix-assisted laser desorption/ionization (MALDI) with IRIS for the direct analysis of small molecules from biological tissues on a Fourier-transform ion cyclotron resonance mass spectrometer. We applied this technique alongside MALDI mass spectrometry imaging to analyse brain tissue from two knockout mouse models of l-lysine catabolism disorders: pyridoxine-dependent epilepsy (ALDH7A1) and glutaric aciduria type 1 (GCDH). The MALDI-IRIS platform, now available for users at HFML-FELIX, represents a significant advance in the direct structural characterization of metabolites in complex biological tissues and opens new possibilities for structure elucidation in the field of MALDI mass spectrometry imaging.


  • A Machine-Learned “Chemical Intuition” to Overcome Spectroscopic Data Scarcity

    by Cailum M. K. Stienstra, Teun van Wieringen, Liam Hebert, Patrick Thomas, Kas J. Houthuijs, Giel Berden, Jos Oomens, Jonathan Martens, W. Scott Hopkins

    Machine learning models for predicting IR spectra of molecular ions (infrared ion spectroscopy, IRIS) have yet to be reported owing to the relatively sparse experimental data sets available. To overcome this limitation, we employ the Graphormer-IR model for neutral molecules as a knowledgeable starting point and then employ transfer learning to refine the model to predict the spectra of gaseous ions. A library of 10,336 computed spectra and a small data set of 312 experimental IRIS spectra is used for model fine-tuning. Nonspecific global graph encodings that describe the molecular charge state (i.e., (de)protonation, sodiation), combined with an additional transfer learning step that considers computed spectra for ions, improved model performance. The resulting Graphormer-IRIS model yields spectra that are 21% more accurate than those produced by commonly employed DFT quantum chemical models, while capturing subtle phenomena such as spectral red-shifts due to sodiation. Dimensionality reduction of model embeddings demonstrates derived "chemical intuition" of functional groups, trends in molecular electron density, and the location of charge sites. Our approach will enable fast IRIS predictions for determining the structures of unknown small molecule analytes (e.g., metabolites, lipids) present in biological samples.


  • Open Access

    Improved multivariate quantification of plastic particles in human blood using non-targeted pyrolysis GC-MS

    by Wilco Nijenhuis, Kas J. Houthuijs, Marthinus Brits, Martin J.M. van Velzen, Sicco H. Brandsma, Marja H. Lamoree, Frederic M. Béen


  • Open Access

    A Machine-Learned "Chemical Intuition" to Overcome Spectroscopic Data Scarcity

    by Cailum M. K. Stienstra, Teun van Wieringen, Liam Hebert, Patrick Thomas, Kas J. Houthuijs, Giel Berden, Jos Oomens, Jonathan Martens, W. Scott Hopkins

    Machine learning models for predicting IR spectra of molecular ions (infrared ion spectroscopy, IRIS) have yet to be reported owing to the relatively sparse experimental datasets available. To overcome this limitation, we employ the Graphormer-IR model for neutral molecules as a knowledgeable starting point, then employ transfer learning to refine the model to predict the spectra of gaseous ions. A library of 10,336 computed spectra and a small dataset of 312 experimental IRIS spectra is used for model fine-tuning. Nonspecific global graph encodings that describe the molecular charge state (i.e., (de)protonation, sodiation), combined with an additional transfer learning step that considers computed spectra for ions, improved model performance. The resulting Graphormer-IRIS model yields spectra that are 21% more accurate than those produced by commonly employed DFT quantum chemical models, while capturing subtle phenomena such as spectral red-shifts due to sodiation. Dimensionality reduction of model embeddings demonstrate derived “chemical intuition” of functional groups, trends in molecular electron density, and the location of charge sites. Our approach will enable fast IRIS predictions for determining the structures of unknown small molecule analytes (e.g., metabolites, lipids) present in biological samples.


  • Development of Nontargeted Workflow of Occupational Exposure by Infrared Ion Spectroscopy and Silicone Wristbands’ Passive Sampling

    by John T. Kelly, Louis E. McNamara, Megan E. Hoover, H. Mitchell Rubenstein, Kas Houthuijs, Jonathan Martens

    A new approach using orthogonal analytical techniques is developed for chemical identification. High resolution mass spectrometry and infrared ion spectroscopy are applied through a 5-level confidence paradigm to demonstrate the effectiveness of nontargeted workflow for the identification of hazardous organophosphates. Triphenyl phosphate is used as a surrogate organophosphate for occupational exposure, and silicone wristbands are used to represent personal samplers. Spectral data of a target compound is combined with spectral data of the sodium adduct and quantum chemical calculations to achieve a confirmed identification. Here, we demonstrate a nontargeted workflow that identifies organophosphate exposure and provides a mechanism for selecting validated methods for quantitative analyses.


  • Open Access

    Characterization of elusive rhamnosyl dioxanium ions and their application in complex oligosaccharide synthesis

    by Peter H. Moons, Floor ter Braak, Frank F. J. de Kleijne, Bart Bijleveld, Sybren J. R. Corver, Kas J. Houthuijs, Hero R. Almizori, Giel Berden, Jonathan Martens, Jos Oomens, et al.

    Attaining complete anomeric control is still one of the biggest challenges in carbohydrate chemistry. Glycosyl cations such as oxocarbenium and dioxanium ions are key intermediates of glycosylation reactions. Characterizing these highly-reactive intermediates and understanding their glycosylation mechanisms are essential to the stereoselective synthesis of complex carbohydrates. Although C-2 acyl neighbouring-group participation has been well-studied, the reactive intermediates in more remote participation remain elusive and are challenging to study. Herein, we report a workflow that is utilized to characterize rhamnosyl 1,3-bridged dioxanium ions derived from C-3 p-anisoyl esterified donors. First, we use a combination of quantum-chemical calculations and infrared ion spectroscopy to determine the structure of the cationic glycosylation intermediate in the gas-phase. In addition, we establish the structure and exchange kinetics of highly-reactive, low-abundance species in the solution-phase using chemical exchange saturation transfer, exchange spectroscopy, correlation spectroscopy, heteronuclear single-quantum correlation, and heteronuclear multiple-bond correlation nuclear magnetic resonance spectroscopy. Finally, we apply C-3 acyl neighbouring-group participation to the synthesis of complex bacterial oligosaccharides. This combined approach of finding answers to fundamental physical-chemical questions and their application in organic synthesis provides a robust basis for elucidating highly-reactive intermediates in glycosylation reactions.


  • Open Access

    A spectroscopic test suggests that fragment ion structure annotations in MS/MS libraries are frequently incorrect

    by Lara van Tetering, Sylvia Spies, Quirine D. K. Wildeman, Kas J. Houthuijs, Rianne E. van Outersterp, Jonathan Martens, Ron A. Wevers, David S. Wishart, Giel Berden, Jos Oomens

    Modern untargeted mass spectrometry (MS) analyses quickly detect and resolve thousands of molecular compounds. Although features are readily annotated with a molecular formula in high-resolution small-molecule MS applications, the large majority of them remains unidentified in terms of their full molecular structure. Collision-induced dissociation tandem mass spectrometry (CID-MS2) provides a diagnostic molecular fingerprint to resolve the molecular structure through a library search. However, for de novo identifications, one must often rely on in silico generated MS2 spectra as reference. The ability of different in silico algorithms to correctly predict MS2 spectra and thus to retrieve correct molecular structures is a topic of lively debate, for instance in the CASMI contest. Underlying the predicted MS2 spectra are the in silico generated product ion structures, which are normally not used in de novo identification, but which can serve to critically assess the fragmentation algorithms. Here we evaluate in silico generated MSn product ion structures by comparison with structures established experimentally by infrared ion spectroscopy (IRIS). For a set of three dozen product ion structures from five precursor molecules, we find that virtually all fragment ion structure annotations in three major in silico MS2 libraries (HMDB, METLIN, mzCloud) are incorrect and caution the reader against their use for structure annotation of MS/MS ions.