George Nemes
Research Subjects
George Nemes has a total of 18 co-authors. Here are the top co-authors by number of shared publications:
Julio Serna
Univ. Complutense (Spain)
5 shared publicationsAurel Stratan
National Institute for Lasers, Plasma, and Radiation Physics 1 , 409 Atomistilor Str., P.O. Box MG-36, 077125 Magurele, Romania
4 shared publicationsAlexandru Zorila
National Institute for Laser, Plasma and Radiation Physics (Romania)
3 shared publications- Laurentiu Rusen
National Institute for Lasers, Plasma, and Radiation Physics, 409 Atomistilor Street, 077125, Romania
3 shared publications A. E. Siegman
1 shared publication- Alexandru Zorila
National Institute for Lasers, Plasma, and Radiation Physics 1 , 409 Atomistilor Str., P.O. Box MG-36, 077125 Magurele, Romania
1 shared publication
Latest Publications
- 1 January 2018
- Published by AIP Publishing in Review of Scientific Instruments
- Vol. 89 (1) , 013104
Comparing the ISO-recommended and the cumulative data-reduction algorithms in S-on-1 laser damage test by a reverse approach method
We compare the ISO-recommended (the standard) data-reduction algorithm used to determine the surface laser-induced damage threshold of optical materials by the S-on-1 test with two newly suggested algorithms, both named “cumulative” algorithms/methods, a regular one and a limit-case one, intended to perform in some respects better than the standard one. To avoid additional errors due to real experiments, a simulated test is performed, named the reverse approach. This approach simulates the real damage experiments, by generating artificial test-data of damaged and non-damaged sites, based on an assumed, known damage threshold fluence of the target and on a given probability distribution function to induce the damage. In this work, a database of 12 sets of test-data containing both damaged and non-damaged sites was generated by using four different reverse techniques and by assuming three specific damage probability distribution functions. The same value for the threshold fluence was assumed, and a Gaussian fluence distribution on each irradiated site was considered, as usual for the S-on-1 test. Each of the test-data was independently processed by the standard and by the two cumulative data-reduction algorithms, the resulting fitted probability distributions were compared with the initially assumed probability distribution functions, and the quantities used to compare these algorithms were determined. These quantities characterize the accuracy and the precision in determining the damage threshold and the goodness of fit of the damage probability curves. The results indicate that the accuracy in determining the absolute damage threshold is best for the ISO-recommended method, the precision is best for the limit-case of the cumulative method, and the goodness of fit estimator (adjusted R-squared) is almost the same for all three algorithms.
- 1 January 2018
- Published by AIP Publishing in Review of Scientific Instruments
- Vol. 89 (1) , 013104
Comparing the ISO-recommended and the cumulative data-reduction algorithms in S-on-1 laser damage test by a reverse approach method
We compare the ISO-recommended (the standard) data-reduction algorithm used to determine the surface laser-induced damage threshold of optical materials by the S-on-1 test with two newly suggested algorithms, both named “cumulative” algorithms/methods, a regular one and a limit-case one, intended to perform in some respects better than the standard one. To avoid additional errors due to real experiments, a simulated test is performed, named the reverse approach. This approach simulates the real damage experiments, by generating artificial test-data of damaged and non-damaged sites, based on an assumed, known damage threshold fluence of the target and on a given probability distribution function to induce the damage. In this work, a database of 12 sets of test-data containing both damaged and non-damaged sites was generated by using four different reverse techniques and by assuming three specific damage probability distribution functions. The same value for the threshold fluence was assumed, and a Gaussian fluence distribution on each irradiated site was considered, as usual for the S-on-1 test. Each of the test-data was independently processed by the standard and by the two cumulative data-reduction algorithms, the resulting fitted probability distributions were compared with the initially assumed probability distribution functions, and the quantities used to compare these algorithms were determined. These quantities characterize the accuracy and the precision in determining the damage threshold and the goodness of fit of the damage probability curves. The results indicate that the accuracy in determining the absolute damage threshold is best for the ISO-recommended method, the precision is best for the limit-case of the cumulative method, and the goodness of fit estimator (adjusted R-squared) is almost the same for all three algorithms.
- 23 November 2015
- Published by SPIE-Intl Soc Optical Eng
- Vol. 9632, 96321H-96321H-9
Analysis of cumulative versus ISO-recommended calculation of damage probability using a database of real S-on-1 tests
- 23 November 2015
- Published by SPIE-Intl Soc Optical Eng
- Vol. 9632, 96321H-96321H-9
Analysis of cumulative versus ISO-recommended calculation of damage probability using a database of real S-on-1 tests
- 8 October 2014
- Published by SPIE-Intl Soc Optical Eng in Optical Engineering
- Vol. 53 (12) , 122513
Measuring effective area of spots from pulsed laser beams
The effective area of a laser spot is an important quantity used to characterize the laser-induced damage threshold of optical materials according to ISO 21254-1:2011 standard. A method for measuring the effective area/diameter of spots from pulsed laser beams using charge-coupled device camera-based beam profilers is presented. Factors affecting the measurement’s accuracy, as the background noise and the size of the summation area, were evaluated using MATLAB®. To minimize the noise contribution, we use an iterative method similar to the one used to measure the second-moment-based spot sizes. We find that the two analyzed components of the background noise, its zero-mean noise and its offset, have an opposite effect on the measurements of the effective area/diameter as compared with the second-moment-based measurements. We prove that there is an upper limit of the relative error of such iterative measurements of effective area, the iteration limit parameter, and that it is a measurable quantity. We measure the effective area/diameter of laser spots with different sizes from a Nd:YAG laser at 1064 nm, 6 ns pulse duration, 10 Hz repetition frequency, and estimate the standard uncertainty of the measurements. Further, we generalize the effective area/diameter concept to include elongated (elliptical/rectangular) spots.
- 8 October 2014
- Published by SPIE-Intl Soc Optical Eng in Optical Engineering
- Vol. 53 (12) , 122513
Measuring effective area of spots from pulsed laser beams
The effective area of a laser spot is an important quantity used to characterize the laser-induced damage threshold of optical materials according to ISO 21254-1:2011 standard. A method for measuring the effective area/diameter of spots from pulsed laser beams using charge-coupled device camera-based beam profilers is presented. Factors affecting the measurement’s accuracy, as the background noise and the size of the summation area, were evaluated using MATLAB®. To minimize the noise contribution, we use an iterative method similar to the one used to measure the second-moment-based spot sizes. We find that the two analyzed components of the background noise, its zero-mean noise and its offset, have an opposite effect on the measurements of the effective area/diameter as compared with the second-moment-based measurements. We prove that there is an upper limit of the relative error of such iterative measurements of effective area, the iteration limit parameter, and that it is a measurable quantity. We measure the effective area/diameter of laser spots with different sizes from a Nd:YAG laser at 1064 nm, 6 ns pulse duration, 10 Hz repetition frequency, and estimate the standard uncertainty of the measurements. Further, we generalize the effective area/diameter concept to include elongated (elliptical/rectangular) spots.
- 1 May 2013
- Published by SPIE-Intl Soc Optical Eng in Optical Engineering
- Vol. 52 (5) , 054203
Measuring the effective pulse duration of nanosecond and femtosecond laser pulses for laser-induced damage experiments
We report on our approach to measure the quantity named effective pulse duration as defined in the ISO 21254-1:2011 standard, which deals with laser-induced damage (LID) threshold measurements. The approach is applied to measure pulses from two laser sources: an injection-seeded electro-optically Q-switched Nd:YAG nanosecond system with 10-Hz pulse repetition frequency, and a fully integrated Ti:sapphire laser with 150–400 fs and 2-kHz pulse repetition frequency. For comparison, the full-width-half-maximum (FWHM) of the same pulses is also measured. The analysis and description of the measurement process, the experimental results, and the corresponding uncertainties are presented. A smaller combined uncertainty is obtained for the effective pulse duration than for the FWHM-defined pulse duration for each time scale involved in experiments. This suggests that the effective pulse duration is the appropriate parameter to characterize the pulse duration in LID experiments.
- 1 May 2013
- Published by SPIE-Intl Soc Optical Eng in Optical Engineering
- Vol. 52 (5) , 054203
Measuring the effective pulse duration of nanosecond and femtosecond laser pulses for laser-induced damage experiments
We report on our approach to measure the quantity named effective pulse duration as defined in the ISO 21254-1:2011 standard, which deals with laser-induced damage (LID) threshold measurements. The approach is applied to measure pulses from two laser sources: an injection-seeded electro-optically Q-switched Nd:YAG nanosecond system with 10-Hz pulse repetition frequency, and a fully integrated Ti:sapphire laser with 150–400 fs and 2-kHz pulse repetition frequency. For comparison, the full-width-half-maximum (FWHM) of the same pulses is also measured. The analysis and description of the measurement process, the experimental results, and the corresponding uncertainties are presented. A smaller combined uncertainty is obtained for the effective pulse duration than for the FWHM-defined pulse duration for each time scale involved in experiments. This suggests that the effective pulse duration is the appropriate parameter to characterize the pulse duration in LID experiments.
- 3 March 2008
- Published by SPIE-Intl Soc Optical Eng in Proceedings of SPIE
- p. 700704
New optics for industrial laser applications: VariSpot and VariFoc
Two new families of zoom optical systems, developed for industrial and medical laser applications, are introduced. First we discuss the main physical processes involved in industrial laser applications and the requirements for the optics. The spatial beam parameters are reviewed, explaining the relatively new concepts of intrinsic stigmatism and intrinsic astigmatism. Then two new zoom systems are discussed, including experimental examples: VariSpot(R), which delivers round spots with adjustable diameters at fixed working distances, and VariFocTM, able to adjust spot shapes and sizes at different working distances. We conclude that these systems represent a valuable addition for industrial and medical lasers.
- 3 March 2008
- Published by SPIE-Intl Soc Optical Eng in Proceedings of SPIE
- p. 700704
New optics for industrial laser applications: VariSpot and VariFoc
Two new families of zoom optical systems, developed for industrial and medical laser applications, are introduced. First we discuss the main physical processes involved in industrial laser applications and the requirements for the optics. The spatial beam parameters are reviewed, explaining the relatively new concepts of intrinsic stigmatism and intrinsic astigmatism. Then two new zoom systems are discussed, including experimental examples: VariSpot(R), which delivers round spots with adjustable diameters at fixed working distances, and VariFocTM, able to adjust spot shapes and sizes at different working distances. We conclude that these systems represent a valuable addition for industrial and medical lasers.
- 16 March 2007
- Published by SPIE-Intl Soc Optical Eng
- Vol. 6606, 66060C
Damage tests for 355 nm laser mirror by using a new variable spot size optical system (VariSpot)
We report preliminary measurements on the catastrophic damage threshold and also on the maximum fluence/irradiance for non-damage of a 355 nm high reflectance mirror, by using a new optical arrangement. Our goal was two-fold: to determine the ability of a new, variable spot size (zoom) optical system (named VariSpot®) to be used in laser-induced damage measurements, and also to characterize the damage properties of the mirror under test. The classical measurement scheme maintains a constant spot size on the target by using a fixed-focus optical system, and the laser fluence/irradiance on the target is varied by appropriately attenuating the laser beam before the focusing optics. In contrast, our scheme maintains constant the energy/power of the incoming beam before the focusing optics and uses a zoom-type optical system to continuously change the spot size and correspondingly the fluence/irradiance on the target, while keeping constant the working distance (from optics to target). A 355 nm beam representing the third harmonic of an electro-optically Q-switched, unstable cavity Nd:YAG laser was used as incoming beam. Its spatial diagnostics was done by using a CMOS-type beam profiler and following the definitions and recommendations of the ISO 11146 standard. The VariSpot optical system represents a prototype with a working distance of approximately 100 mm and delivering a round and adjustable spot size with diameters from 0.085 mm to 4.3 mm at that distance for the specific 355 nm incoming laser beam. The results show the advantages of using the VariSpot system for such type of measurements and also reveal reasonable good damage properties of the tested mirror. We briefly discuss the major sources of errors in the obtained results and also suggest several ways to improve the future measurements using similar arrangements.
- 16 March 2007
- Published by SPIE-Intl Soc Optical Eng
- Vol. 6606, 66060C
Damage tests for 355 nm laser mirror by using a new variable spot size optical system (VariSpot)
We report preliminary measurements on the catastrophic damage threshold and also on the maximum fluence/irradiance for non-damage of a 355 nm high reflectance mirror, by using a new optical arrangement. Our goal was two-fold: to determine the ability of a new, variable spot size (zoom) optical system (named VariSpot®) to be used in laser-induced damage measurements, and also to characterize the damage properties of the mirror under test. The classical measurement scheme maintains a constant spot size on the target by using a fixed-focus optical system, and the laser fluence/irradiance on the target is varied by appropriately attenuating the laser beam before the focusing optics. In contrast, our scheme maintains constant the energy/power of the incoming beam before the focusing optics and uses a zoom-type optical system to continuously change the spot size and correspondingly the fluence/irradiance on the target, while keeping constant the working distance (from optics to target). A 355 nm beam representing the third harmonic of an electro-optically Q-switched, unstable cavity Nd:YAG laser was used as incoming beam. Its spatial diagnostics was done by using a CMOS-type beam profiler and following the definitions and recommendations of the ISO 11146 standard. The VariSpot optical system represents a prototype with a working distance of approximately 100 mm and delivering a round and adjustable spot size with diameters from 0.085 mm to 4.3 mm at that distance for the specific 355 nm incoming laser beam. The results show the advantages of using the VariSpot system for such type of measurements and also reveal reasonable good damage properties of the tested mirror. We briefly discuss the major sources of errors in the obtained results and also suggest several ways to improve the future measurements using similar arrangements.
- 1 January 2007
- Published by Optica Publishing Group
- p. LThB6
Defining the Degree of General Astigmatism of a General Astigmatic Beam
We define the degree of general astigmatism (DGA) of a general astigmatic beam, a measurable positive number expressing the departure of such a beam from more symmetrical beams, the latter having the DGA = 0.
- 1 January 2007
- Published by Optica Publishing Group
- p. LThB6
Defining the Degree of General Astigmatism of a General Astigmatic Beam
We define the degree of general astigmatism (DGA) of a general astigmatic beam, a measurable positive number expressing the departure of such a beam from more symmetrical beams, the latter having the DGA = 0.
- 31 August 2006
- Published by SPIE-Intl Soc Optical Eng
- Vol. 6290, 629008
Optical system for variable resizing of round flat-top distributions
An optical system is described which is capable of variable resizing of a round flat-top light distribution of a highly coherent and collimated laser beam at a certain, fixed working distance. It contains cylindrical and spherical optics. First-order optics is used to analyze the system, and the second-order moments method is used to describe the beam properties. The analysis indicates the existence of an "image-mode" regime, allowing a dynamic range, or a zoom range of about (13 - 15) : 1 for resizing the diameter of the round, flat-top distribution in the target plane, by rotating one cylindrical element. Experiments using as incoming beam a collimated Ar-laser TEM00 gaussian beam reshaped to a collimated flat-top with 6.8 mm in diameter, confirm the approach, by obtaining at the target plane spot sizes with diameters continuously variable between 1.0 mm and 13.6 mm and with flat-top profiles.
- 31 August 2006
- Published by SPIE-Intl Soc Optical Eng
- Vol. 6290, 629008
Optical system for variable resizing of round flat-top distributions
An optical system is described which is capable of variable resizing of a round flat-top light distribution of a highly coherent and collimated laser beam at a certain, fixed working distance. It contains cylindrical and spherical optics. First-order optics is used to analyze the system, and the second-order moments method is used to describe the beam properties. The analysis indicates the existence of an "image-mode" regime, allowing a dynamic range, or a zoom range of about (13 - 15) : 1 for resizing the diameter of the round, flat-top distribution in the target plane, by rotating one cylindrical element. Experiments using as incoming beam a collimated Ar-laser TEM00 gaussian beam reshaped to a collimated flat-top with 6.8 mm in diameter, confirm the approach, by obtaining at the target plane spot sizes with diameters continuously variable between 1.0 mm and 13.6 mm and with flat-top profiles.
- 9 February 2006
- Published by SPIE-Intl Soc Optical Eng
- p. 610118-610118-12
Correlation between geometrical and intrinsic classification of general astigmatic laser beams
The second-order moments method is a standard method to characterize laser beams. All beams are described by a beam matrix, with specific mathematical properties. The geometrical classification of these beams is based on their matrix structure, or symmetry, rather than on the symmetry of beams' cross sections in freespace propagation. Accordingly, the beams can be stigmatic, simple astigmatic, or general astigmatic. On the other hand, at propagation through ABCD -type optical systems, some intrinsic properties of the beams remain invariant. Two independent invariant quantities define two classes and four types of families of beams, providing the intrinsic classification of beams, irrespective of their geometrical classification. The paper reveals the intrinsic classification of the general astigmatic beams, by determining the intrinsic class and family each general astigmatic beam matrix belongs to. First, we summarize previous results which are important to understand and to obtain the new results of this paper. This includes the beam description using two more mathematical models, one using the same beam matrix with a different order of the elements, and the other being the gaussian-Schell-model. Then we show what kind of information on the invariants we can retrieve from the mathematical properties of the different quantities used in the three beam descriptions. Finally we analyze all possible non-degenerate matrices representing general astigmatic beams (ten in all) and apply the information retrieved as described above for each of them. The final result is a list of all ten matrices representing general astigmatic beams and their intrinsic classification.
- 9 February 2006
- Published by SPIE-Intl Soc Optical Eng
- p. 610118-610118-12
Correlation between geometrical and intrinsic classification of general astigmatic laser beams
The second-order moments method is a standard method to characterize laser beams. All beams are described by a beam matrix, with specific mathematical properties. The geometrical classification of these beams is based on their matrix structure, or symmetry, rather than on the symmetry of beams' cross sections in freespace propagation. Accordingly, the beams can be stigmatic, simple astigmatic, or general astigmatic. On the other hand, at propagation through ABCD -type optical systems, some intrinsic properties of the beams remain invariant. Two independent invariant quantities define two classes and four types of families of beams, providing the intrinsic classification of beams, irrespective of their geometrical classification. The paper reveals the intrinsic classification of the general astigmatic beams, by determining the intrinsic class and family each general astigmatic beam matrix belongs to. First, we summarize previous results which are important to understand and to obtain the new results of this paper. This includes the beam description using two more mathematical models, one using the same beam matrix with a different order of the elements, and the other being the gaussian-Schell-model. Then we show what kind of information on the invariants we can retrieve from the mathematical properties of the different quantities used in the three beam descriptions. Finally we analyze all possible non-degenerate matrices representing general astigmatic beams (ten in all) and apply the information retrieved as described above for each of them. The final result is a list of all ten matrices representing general astigmatic beams and their intrinsic classification.