APAlexander Pirker

Alexander Pirker

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Alexander Pirker has a total of 7 co-authors. Here are the top co-authors by number of shared publications:

  • U. Schichler

    Institute of High Voltage Engineering and System Performance, Graz University of Technology, Inffeldgasse 18, 8010 Graz, Austria

    2 shared publications
  • Uwe Schichler

    Graz University of Technology, Institute of High Voltage Engineering and System Performance, Inffeldgasse 18, 8010 Graz, Austria

    2 shared publications
  • Michael Muhr

    Institute of High Voltage Engineering and System Management, TU Graz, Austria

    1 shared publication
  • Mutiara Sofia Siregar

    PT. PLN (Persero), Jakarta, Indonesia

    1 shared publication
  • Rudolf Woschitz

    Technische Universität Graz, Austria

    1 shared publication
  • Suwarno

    Institut Teknologi Bandung, Indonesia

    1 shared publication

Latest Publications

  • Partial discharge measurement at DC voltage — Evaluation and characterization by NoDi∗ pattern

    by Alexander Pirker, Uwe Schichler

    In this paper the requirements on PD measurement systems for DC voltage are summarized and the experience gained about the PD behavior of some typical defects in HVDC GIS and GIL are discussed. Some physical effects at different voltage levels are shown and a method for the representation and characterization of the PD pulse sequences is introduced. Special test cells with different types of defects such as a protrusion, a floating electrode, a free moving particle and a void are used for the investigations. The procedure for PD measurement at DC voltage is improved and PD pulse sequences at different gas pressures and voltage levels were recorded. In a further step the PD behavior up to the breakdown voltage was determined. The NoDi* pattern was developed for the visualization and interpretation of the measured PD pulse sequences. This pattern supports the visualization and the physical interpretation of the pulse sequences and may allow the characterization of the typical defects in HVDC GIS and GIL by a human expert.


  • Partial discharges of defects in different insulating gases: N2, CO2, dry air and SF6

    by A. Pirker, U. Schichler

    Due to the global warming potential of SF 6 and the rising number of ecological and economic considerations, it is becoming increasingly important to develop gas insulated systems which use an environmentally-acceptable gas. The partial discharge (PD) measurement plays an important role in testing, assessing and monitoring of all gas insulated components. Due to the different behavior of some defects related to DC voltage, the measurement procedures and acceptance criteria for AC voltage cannot be fully adapted for DC voltage. In this paper, the behavior of three typical defects at GIS and GIL (protrusion, floating electrode and free metallic particle) at four different gases (N 2 , CO 2 , dry air and SF 6 ) and for different gas pressures are described, and the differences in PD activity at AC and DC voltage are shown. The PD inception voltages of the various measurements are compared, and typical PD patterns at AC and DC voltage are described. In this context, the innovative NoDi* pattern for visualization and physical interpretation of the measured pulse sequences at DC voltage is presented.


  • Partial discharges at DC voltage - measurement and pattern recognition

    by A. Pirker, U. Schichler

    Knowledge of the current status of the components of an electrical power supply is essential for power grids to operate safely and economically. This means that the partial discharge diagnosis is of great importance for AC grids. It also plays an important role in connection with the increase in HVDC technology; the PD diagnosis is important for the condition assessment of the involved components. The AC PD measurement, the measurement procedure, and especially the interpretation of results cannot fully be adapted to DC voltage. In this paper, the previous findings of investigations about the PD behavior of some typical defects under different artificial environmental conditions and different measuring procedures are summarized. To analyze the numerous measured PD sequences, a software tool called “PDDC Analyzer” was developed. With this tool, well-known DC PD graphs can be shown and new methods for creating a DC PD pattern for defect identification and risk assessment can be investigated. The quality of the improved NoDi* Pattern is shown and the measurement procedures are discussed. At the end, new methods and aspects for PD identification at DC are introduced and a short overview of further research is given.


  • Partial discharge patterns on cross-linked polyethylene DC power cables

    by Mutiara Sofia Siregar, Rudolf Woschitz, Uwe Schichler, Alexander Pirker, Suwarno

    Since electrical energy supply is crucial and HVAC applications play a significant role in that field, work and discussion about PD are mostly related to AC voltage. The situation is different recently because HVDC applications have started to take a part on the electrical energy supply. HVDC cable systems nowadays have been replaced the use of HVAC cable systems for transporting energy over long distances because some advantages it has. Cross-linked polyethylene (XLPE) cables are increasingly taking the place of mass-impregnated (MI) and oil-filled (OF) cables in power transmission because they are easier to maintain and are less likely to cause oil leakage. The number of new installed high voltage XLPE power cable increases because of the increase of the use of XLPE cables. In order to investigate partial discharge (PD) phenomena on a cable, XLPE cables with artificial defects are created and tested under DC voltage. This paper describes the DC voltage partial discharge characteristics for different sources such as surface discharge and void discharge. By comparing new representations of DC PD named “NoDi* Pattern” with conventional “PD magnitude as a function of time”, DC PD patterns can be shown and discussed.


  • Conductivity measurements of electrical insulating oils

    by Thomas Judendorfer, Alexander Pirker, Michael Muhr

    Mineral oils play - in combination with cellulose (paper and pressboard), a vital part in the insulation system of large transformers and bushings. The dielectric stress within such insulation systems during high voltage direct current (HVDC) network operation is defined by a mixed stress that consists of AC, DC and transient components. Exemplary, the valve winding of converter transformers is to be named here. Profound knowledge of materials parameters like, for example, electrical conductivity, is crucial for a safe and reliable design of HVDC equipment. First of all, the electrical conductivity of insulating oil is a material parameter and differs with oil type and manufacturer. These differences can reach easily one or even several orders of magnitude. Furthermore, the electrical conductivity is strongly dependent on temperature and on electrical field strength. The electrical field strength differs generally between material measurements and actual operating conditions. Finally the electrical conductivity can also vary with ageing, generally it will increase with advancing ageing. These influences are all together very inconvenient for the design engineer as the electrical field stress within an insulation system can change significantly during the operational life cycle of electrical equipment. For this work, measurements of electrical conductivity have been made for insulating (mineral) oils with test cells according to the IEC 60247 standard. Two different oils have been tested. The temperature has been varied between room temperature (22°C) and 90°C. It could be demonstrated, that there is a strong influence of the oil type and oil temperature on the electrical conductivity.