Adnan Al-Sibahy
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Research Interests
Adnan Al-Sibahy has a total of 5 co-authors. Here are the top co-authors by number of shared publications:
- Rodger Edwards
Unversity of Manchester, Manchester, the United Kingdom
8 shared publications Maha Sabhan
2 shared publicationsSafaa Mashshay
2 shared publicationsAhmed Tarish
1 shared publicationRodger Edwards
1 shared publication
Latest Publications
- Open Access
- 9 November 2021
- Published by MDPI AG in Infrastructures
- Vol. 6 (11) , 160
Effect of Chases with Renovation Techniques on the Load Carrying Capacity of Masonry Walls
Infrastructure through the masonry walls (for example, wiring and piping works) are usually installed using chases in different directions. Introducing these chases in a newly built wall will affect its overall load carrying capacity. However, there has thus far been very limited research into the effects of chases on the response and load carrying capacity of walls. This study has been undertaken to evaluate the structural behaviour of new masonry walls having chases in both horizontal and vertical directions and subjected to compression load throughout an extensive experimental programme. In addition, two renovation techniques have been proposed to infill the chases created in small scale walls (wallettes). The first technique involved the use of plastic wire mesh and cement mortar, while the second incorporated using galvanized steel channel together with the plastic wire mesh and cement mortar. Furthermore, a reference case of wallette without chases has been considered to enable reasonable comparisons to check the effect of the chases and the efficiency of the proposed renovation techniques. The outcomes of this study were used to modify the design equations proposed in the relevant codes of practice. The obtained results showed a notable reduction in the load carrying capacity of the masonry wall due to the introduction of the chases with a reduction percentage of 29% compared to the masonry wall without chase. The percentage decrease depends on the depth of the chase and the inclination angle of the load flow. The walls with horizontal chases exhibited more reduction in the load carrying capacity compared to those with vertical chases. The adopted renovation techniques using galvanized steel channel and/or plastic wire mesh with cement mortar recovered 55% and 93% of the lost load carrying capacity due to the presence of the chase and the failure was due to the de-bonded phenomena of the infill materials. Suitable factors of safety have been proposed to be incorporated in the compressive strength and modulus of elasticity formulas of the masonry walls of the BS EN codes.
- 9 November 2021
- Published by MDPI AG in Infrastructures
- Vol. 6 (11) , 160
Open AccessEffect of Chases with Renovation Techniques on the Load Carrying Capacity of Masonry Walls
Infrastructure through the masonry walls (for example, wiring and piping works) are usually installed using chases in different directions. Introducing these chases in a newly built wall will affect its overall load carrying capacity. However, there has thus far been very limited research into the effects of chases on the response and load carrying capacity of walls. This study has been undertaken to evaluate the structural behaviour of new masonry walls having chases in both horizontal and vertical directions and subjected to compression load throughout an extensive experimental programme. In addition, two renovation techniques have been proposed to infill the chases created in small scale walls (wallettes). The first technique involved the use of plastic wire mesh and cement mortar, while the second incorporated using galvanized steel channel together with the plastic wire mesh and cement mortar. Furthermore, a reference case of wallette without chases has been considered to enable reasonable comparisons to check the effect of the chases and the efficiency of the proposed renovation techniques. The outcomes of this study were used to modify the design equations proposed in the relevant codes of practice. The obtained results showed a notable reduction in the load carrying capacity of the masonry wall due to the introduction of the chases with a reduction percentage of 29% compared to the masonry wall without chase. The percentage decrease depends on the depth of the chase and the inclination angle of the load flow. The walls with horizontal chases exhibited more reduction in the load carrying capacity compared to those with vertical chases. The adopted renovation techniques using galvanized steel channel and/or plastic wire mesh with cement mortar recovered 55% and 93% of the lost load carrying capacity due to the presence of the chase and the failure was due to the de-bonded phenomena of the infill materials. Suitable factors of safety have been proposed to be incorporated in the compressive strength and modulus of elasticity formulas of the masonry walls of the BS EN codes.
- 1 December 2020
- Published by Elsevier in Structures
- Vol. 28, 309-320
Development of hybrid ECC columns subjected to concentric and eccentric loading
- 1 December 2020
- Published by Elsevier in Structures
- Vol. 28, 309-320
Development of hybrid ECC columns subjected to concentric and eccentric loading
- Open Access
- 1 December 2020
- Published by Elsevier in Case Studies in Construction Materials
- Vol. 13
Structural evaluation for the historic Palace of King Ghazi and mechanism of its rehabilitation
- 1 December 2020
- Published by Elsevier in Case Studies in Construction Materials
- Vol. 13
Open AccessStructural evaluation for the historic Palace of King Ghazi and mechanism of its rehabilitation
- 1 July 2020
- Published by Elsevier in Construction and Building Materials
- Vol. 250
Corrosion effects on the bond behaviour of steel bars in self-compacting concrete
- 1 July 2020
- Published by Elsevier in Construction and Building Materials
- Vol. 250
Corrosion effects on the bond behaviour of steel bars in self-compacting concrete
- Open Access
- 1 March 2020
- Published by Al-Qadisiyah Journal for Engineering Sciences (QJES) in Al-Qadisiyah Journal for Engineering Sciences
- Vol. 13 (1) , 30-35
Structural Behavior of Novel ECC Short Columns Subjected to Eccentric Loading
This study was undertaken in order to investigate the structural behaviour of novel Engineering Cementitious Composites (ECC) columns subjected to eccentric loading. These columns were experimentally formulated using a hybridization of steel and polypropylene fibres. Two ratios were adopted for the steel fibres of 0.5% and 1%, whilst the polypropylene fibre was kept to be constant at a ratio of 0.5% for all of the ECC columns. The eccentric loads were applied at two eccentricities: small (h/6) and large (5h/12). A comparison was also made with the behaviour of self-compacting concrete and traditional ECC columns containing either steel or polypropylene fibres. The vertical and lateral deformations as well as the maximum load at failure were noted. The results obtained showed that the hybrid ECC columns exhibited higher load carrying capacities when compared with those of both self-compacting concrete and traditional ECC columns. The percentage increase was 30%. The hybrid ECC column samples containing 1% steel fibre did not show a signification difference in the load-deformation behaviour when it compared with that containing 0.5% steel fibre. The values of eccentricity governed the global behaviour of the tested columns. The predicated load carrying capacity of the ECC columns needs a magnification factor in case of concentric test, and to take into account the existence of fibres ratio when calculating the area of steel reinforcement for eccentric loading.
- 1 March 2020
- Published by Al-Qadisiyah Journal for Engineering Sciences (QJES) in Al-Qadisiyah Journal for Engineering Sciences
- Vol. 13 (1) , 30-35
Open AccessStructural Behavior of Novel ECC Short Columns Subjected to Eccentric Loading
This study was undertaken in order to investigate the structural behaviour of novel Engineering Cementitious Composites (ECC) columns subjected to eccentric loading. These columns were experimentally formulated using a hybridization of steel and polypropylene fibres. Two ratios were adopted for the steel fibres of 0.5% and 1%, whilst the polypropylene fibre was kept to be constant at a ratio of 0.5% for all of the ECC columns. The eccentric loads were applied at two eccentricities: small (h/6) and large (5h/12). A comparison was also made with the behaviour of self-compacting concrete and traditional ECC columns containing either steel or polypropylene fibres. The vertical and lateral deformations as well as the maximum load at failure were noted. The results obtained showed that the hybrid ECC columns exhibited higher load carrying capacities when compared with those of both self-compacting concrete and traditional ECC columns. The percentage increase was 30%. The hybrid ECC column samples containing 1% steel fibre did not show a signification difference in the load-deformation behaviour when it compared with that containing 0.5% steel fibre. The values of eccentricity governed the global behaviour of the tested columns. The predicated load carrying capacity of the ECC columns needs a magnification factor in case of concentric test, and to take into account the existence of fibres ratio when calculating the area of steel reinforcement for eccentric loading.
- Open Access
- 31 December 2019
- Published by Al-Qadisiyah Journal for Engineering Sciences (QJES) in Al-Qadisiyah Journal for Engineering Sciences
- Vol. 12 (4) , 260–266
Pullout strength behaviour of self-compacted concrete in aggressive solutions
The aim of this study was to investigate the pullout strength behaviour of self-compacted concrete under corrosion conditions. Block samples with two configurations were formulated. A total number of twelve block samples in addition to 24 cubes were tested. The hardened concrete samples were either cured in tap water or exposed to salt solution. A suitable epoxy was used for coating part of the formulated samples. The preliminary mechanical properties and the rate of corrosion were firstly measured, the pullout was then carried out. A comparison was also made with the relevant code of practice. The results obtained showed that both compressive strength and density features exhibited a notable increase at an early age when the samples are exposed to salt solution. The adverse effect of such curing condition appeared at the later ages when the corrosion rate became more intensive. The highest decrease in the value of pullout strength was observed for the reinforced concrete block samples containing epoxy coating reaching to 44.5% less than those cured in tap water.
- 31 December 2019
- Published by Al-Qadisiyah Journal for Engineering Sciences (QJES) in Al-Qadisiyah Journal for Engineering Sciences
- Vol. 12 (4) , 260–266
Open AccessPullout strength behaviour of self-compacted concrete in aggressive solutions
The aim of this study was to investigate the pullout strength behaviour of self-compacted concrete under corrosion conditions. Block samples with two configurations were formulated. A total number of twelve block samples in addition to 24 cubes were tested. The hardened concrete samples were either cured in tap water or exposed to salt solution. A suitable epoxy was used for coating part of the formulated samples. The preliminary mechanical properties and the rate of corrosion were firstly measured, the pullout was then carried out. A comparison was also made with the relevant code of practice. The results obtained showed that both compressive strength and density features exhibited a notable increase at an early age when the samples are exposed to salt solution. The adverse effect of such curing condition appeared at the later ages when the corrosion rate became more intensive. The highest decrease in the value of pullout strength was observed for the reinforced concrete block samples containing epoxy coating reaching to 44.5% less than those cured in tap water.
- Open Access
- 28 November 2018
- Published by Science Publishing Corporation in International Journal of Engineering & Technology
- Vol. 7 (4.20) , 266-270
Behaviour of Gypsum Plasterboards Under Mechanical Loads and Thermal Effects
This paper presents an experimental study conducted to investigate the behaviour of gypsum plasterboard assemblies subjected to mechanical loads and thermal effects. These assemblies were boxes in shape and connected to reinforced concrete slabs. Each side of gypsum plasterboard was fastened using either two or three bolts. The loads were applied at the assembly centre and the maximum flexural load at failure was recorded. Besides, the elapsed time to failure was monitored.The results obtained showed that the material property of the plasterboard and the method of fastening are governed the global behaviour of the tested samples. The average flexural braking loads at failure were 538 N and 564 N for the assemblies fastened with two and three bolts, respectively. The corresponding failure times under conditions of fire exposure and mechanical loading were 2.1 minutes and 1.7 minutes, respectively. Suitable emended were made for the expressions suggested by the related codes of practice in order to suit the experimental results
- 28 November 2018
- Published by Science Publishing Corporation in International Journal of Engineering & Technology
- Vol. 7 (4.20) , 266-270
Open AccessBehaviour of Gypsum Plasterboards Under Mechanical Loads and Thermal Effects
This paper presents an experimental study conducted to investigate the behaviour of gypsum plasterboard assemblies subjected to mechanical loads and thermal effects. These assemblies were boxes in shape and connected to reinforced concrete slabs. Each side of gypsum plasterboard was fastened using either two or three bolts. The loads were applied at the assembly centre and the maximum flexural load at failure was recorded. Besides, the elapsed time to failure was monitored.The results obtained showed that the material property of the plasterboard and the method of fastening are governed the global behaviour of the tested samples. The average flexural braking loads at failure were 538 N and 564 N for the assemblies fastened with two and three bolts, respectively. The corresponding failure times under conditions of fire exposure and mechanical loading were 2.1 minutes and 1.7 minutes, respectively. Suitable emended were made for the expressions suggested by the related codes of practice in order to suit the experimental results
- 1 March 2018
- Published by Emerald Publishing in Proceedings of the Institution of Civil Engineers - Structures and Buildings
- Vol. 171 (3) , 253-262
Effect of admixtures on the behaviour of lightweight concretes
This paper presents an experimental investigation of the combined effect of a superplasticiser admixture and metakaolin material on the mechanical behaviour of expanded clay lightweight concrete containing recycled glass aggregate. The optimum dosage of the superplasticiser admixture (type SNF) was adjusted and used by weight of cement. The short- and long-term mechanical properties of concrete mixes were measured in accordance with the relevant British/EN standards. The results obtained were compared with the results of control concrete mixes (without superplasticiser). They showed that the superplasticiser admixture exhibited a 20% reduction in mixing water content. All measured values of unit weight, compressive and splitting tensile strengths increased when the superplasticiser admixture and metakaolin material were used. The concrete mix containing 30% recycled glass revealed an increase in the mechanical strength compared with the mix of 15% recycled glass. However, the workability of the superplasticiser concrete mixes was degraded, reaching 44% reduction in slump value.
- 1 March 2018
- Published by Emerald Publishing in Proceedings of the Institution of Civil Engineers - Structures and Buildings
- Vol. 171 (3) , 253-262
Effect of admixtures on the behaviour of lightweight concretes
This paper presents an experimental investigation of the combined effect of a superplasticiser admixture and metakaolin material on the mechanical behaviour of expanded clay lightweight concrete containing recycled glass aggregate. The optimum dosage of the superplasticiser admixture (type SNF) was adjusted and used by weight of cement. The short- and long-term mechanical properties of concrete mixes were measured in accordance with the relevant British/EN standards. The results obtained were compared with the results of control concrete mixes (without superplasticiser). They showed that the superplasticiser admixture exhibited a 20% reduction in mixing water content. All measured values of unit weight, compressive and splitting tensile strengths increased when the superplasticiser admixture and metakaolin material were used. The concrete mix containing 30% recycled glass revealed an increase in the mechanical strength compared with the mix of 15% recycled glass. However, the workability of the superplasticiser concrete mixes was degraded, reaching 44% reduction in slump value.
- 1 September 2017
- Published by Elsevier in Engineering Structures
- Vol. 147, 517-529
Characterization of the clay masonry units and construction technique at the ancient city of Nippur
- 1 September 2017
- Published by Elsevier in Engineering Structures
- Vol. 147, 517-529
Characterization of the clay masonry units and construction technique at the ancient city of Nippur