Bijan Kumar Mandal
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Research Interests
Bijan Kumar Mandal has a total of 38 co-authors. Here are the top co-authors by number of shared publications:
- Ranendra Roy
Department of Mechanical Engineering, IIEST Shibpur, Howrah 711103, West Bengal, India
11 shared publications Ambarish Datta
8 shared publications- Arup Jyoti Bhowal
Heritage Institute of Technology
6 shared publications - Ambarish Datta
Department of Mechanical Engineering, Indian Institute of Engineering Science and Technology, Shibpur, Howrah – 711103, West Bengal, India
5 shared publications Achin Kumar Chowdhuri
Indian Institute of Engineering Science and Technology, Shibpur
4 shared publications- Pijush Kanti Mondal
Gaighata Govt. Polytechnic
3 shared publications
Latest Publications
- 2 February 2025
- Published by Springer Nature
- p. 77-88
Comparative Review on Biodiesel with Water-Emulsified Diesel as an Alternative Fuel for CI Engines
- 2 February 2025
- Published by Springer Nature
- p. 77-88
Comparative Review on Biodiesel with Water-Emulsified Diesel as an Alternative Fuel for CI Engines
- 9 December 2024
- Published by Wiley in Journal of Thermal Science and Engineering Applications
- Vol. 17 (2) , 1-32
Effect of Variation of the Aspect Ratio of Rectangular Twisted Tapes Inserted in a Circular Pipe on the Thermal Performance
This study aims to determine the effect of the aspect ratio of the cross section of a rectangular twisted tape on the laminar heat transfer characteristics inside an isothermally heated circular pipe. Detailed three-dimensional simulations reveal facts that would be difficult to estimate otherwise. A novel study of the evolution of the axial and secondary velocity fields as well as the temperature field within the pipe is presented to understand the flow physics behind the heat transfer enhancement. The three-dimensional simulation results are used to accurately calculate the portion of the total energy of the flow that is converted to secondary kinetic energy. In addition to the Nusselt number and friction factor, three parameters, viz. relative increase in heat transfer coefficient, relative increase in pressure drop, and thermo-hydraulic performance factor are used to quantify the effect of the twisted tape. While both the heat transfer and the pressure drop increase with a decrease in the twist ratio (TR), the thermo-hydraulic performance factor (THPF) is found to become almost independent of TR as the aspect ratio (AR) decreases to low values. It is inferred from the present results that although a twisted tape with a small pitch and large aspect ratio enhances heat transfer performance, a lower aspect ratio may provide a better option from a power requirement perspective. Hence, this work shows, for the first time, that a square-like cross section of the twisted tape could be advantageous.
- 9 December 2024
- Published by Wiley in Journal of Thermal Science and Engineering Applications
- Vol. 17 (2) , 1-32
Effect of Variation of the Aspect Ratio of Rectangular Twisted Tapes Inserted in a Circular Pipe on the Thermal Performance
This study aims to determine the effect of the aspect ratio of the cross section of a rectangular twisted tape on the laminar heat transfer characteristics inside an isothermally heated circular pipe. Detailed three-dimensional simulations reveal facts that would be difficult to estimate otherwise. A novel study of the evolution of the axial and secondary velocity fields as well as the temperature field within the pipe is presented to understand the flow physics behind the heat transfer enhancement. The three-dimensional simulation results are used to accurately calculate the portion of the total energy of the flow that is converted to secondary kinetic energy. In addition to the Nusselt number and friction factor, three parameters, viz. relative increase in heat transfer coefficient, relative increase in pressure drop, and thermo-hydraulic performance factor are used to quantify the effect of the twisted tape. While both the heat transfer and the pressure drop increase with a decrease in the twist ratio (TR), the thermo-hydraulic performance factor (THPF) is found to become almost independent of TR as the aspect ratio (AR) decreases to low values. It is inferred from the present results that although a twisted tape with a small pitch and large aspect ratio enhances heat transfer performance, a lower aspect ratio may provide a better option from a power requirement perspective. Hence, this work shows, for the first time, that a square-like cross section of the twisted tape could be advantageous.
- 18 May 2023
- Published by Wiley in Journal of Thermal Science and Engineering Applications
- Vol. 15 (8) , 1-34
Heat Transfer Enhancement in Laminar Pipe Flow Using Al2O3–Water Nanofluid and Twisted Tape Inserts
In this study, an attempt has been made to carry out a numerical investigation using water-based Al2O3 nanofluid, flowing through a circular tube under constant inlet temperature and constant heat flux conditions in the laminar flow regime. The water-based Al2O3 nanofluid is used in a circular plain tube first, and then, this process is repeated for the same tube fitted with twisted tape inserts of twist ratio 1.85 at Reynolds numbers ranging from 680 to 2030. For the numerical analysis, ANSYS FLUENT is used to solve three-dimensional conservation equations of mass, momentum, and energy. The simulated results indicate that when twisted tape is used, heat transfer rates increase significantly with the use of nanofluid. In the case of nanofluid with the plain tube, only 10–24% enhancement in heat transfer rate is noted. On the other hand, almost 27–45% increase in heat transfer is observed compared to that with only water when twisted tape is inserted into it. Also, the friction factor increases as the nanoparticle volume fraction increases. However, the effect on the heat transfer rate is more significant than that on the friction factor. The best thermohydraulic performance factor achieved is 2.1 using nanofluids with a 5% volume fraction of the nanoparticles at a high Reynolds number when twisted tape is also inserted.
- 18 May 2023
- Published by Wiley in Journal of Thermal Science and Engineering Applications
- Vol. 15 (8) , 1-34
Heat Transfer Enhancement in Laminar Pipe Flow Using Al2O3–Water Nanofluid and Twisted Tape Inserts
In this study, an attempt has been made to carry out a numerical investigation using water-based Al2O3 nanofluid, flowing through a circular tube under constant inlet temperature and constant heat flux conditions in the laminar flow regime. The water-based Al2O3 nanofluid is used in a circular plain tube first, and then, this process is repeated for the same tube fitted with twisted tape inserts of twist ratio 1.85 at Reynolds numbers ranging from 680 to 2030. For the numerical analysis, ANSYS FLUENT is used to solve three-dimensional conservation equations of mass, momentum, and energy. The simulated results indicate that when twisted tape is used, heat transfer rates increase significantly with the use of nanofluid. In the case of nanofluid with the plain tube, only 10–24% enhancement in heat transfer rate is noted. On the other hand, almost 27–45% increase in heat transfer is observed compared to that with only water when twisted tape is inserted into it. Also, the friction factor increases as the nanoparticle volume fraction increases. However, the effect on the heat transfer rate is more significant than that on the friction factor. The best thermohydraulic performance factor achieved is 2.1 using nanofluids with a 5% volume fraction of the nanoparticles at a high Reynolds number when twisted tape is also inserted.
- 31 March 2021
- Published by Wiley in Journal of Thermal Science and Engineering Applications
- Vol. 13 (6) , 1-31
Thermoeconomic Analysis of Vapor Compression Refrigeration System With Dedicated Subcooler for High-Temperature Lift Applications
A single-stage vapor compression refrigeration system becomes inefficient and impractical when the temperature lift between the evaporator and the condenser becomes large. Under the high-temperature lift, different losses in the system increase, and more refrigerant vapor is formed at the end of the throttling process. The authors have attempted to analyze a vapor compression refrigeration system with a dedicated subcooler for high-temperature lift applications using R134a in the main cycle and four low global warming potential (GWP) refrigerants in the subcooler cycle. The modeling of the proposed system has been carried out in Engineering Equation Solver (EES) considering the energy, exergy, and economic aspects for the simulation of the system. The predicted results show that the use of the proposed system is more beneficial from both performance and economic point of view for high-temperature lift. Nearly 27% improvement in both energetic and exergetic performances are noted whereas cost is reduced by 2% when the proposed system is used instead of a typical refrigeration system. Finally, the present investigation concludes that the use of refrigerant R1234ze is much efficient than the other investigated refrigerants due to its low GWP and compressor discharge temperature, in spite of achieving better thermo-economic performances using R152a as subcooler refrigerant.
- 31 March 2021
- Published by Wiley in Journal of Thermal Science and Engineering Applications
- Vol. 13 (6) , 1-31
Thermoeconomic Analysis of Vapor Compression Refrigeration System With Dedicated Subcooler for High-Temperature Lift Applications
A single-stage vapor compression refrigeration system becomes inefficient and impractical when the temperature lift between the evaporator and the condenser becomes large. Under the high-temperature lift, different losses in the system increase, and more refrigerant vapor is formed at the end of the throttling process. The authors have attempted to analyze a vapor compression refrigeration system with a dedicated subcooler for high-temperature lift applications using R134a in the main cycle and four low global warming potential (GWP) refrigerants in the subcooler cycle. The modeling of the proposed system has been carried out in Engineering Equation Solver (EES) considering the energy, exergy, and economic aspects for the simulation of the system. The predicted results show that the use of the proposed system is more beneficial from both performance and economic point of view for high-temperature lift. Nearly 27% improvement in both energetic and exergetic performances are noted whereas cost is reduced by 2% when the proposed system is used instead of a typical refrigeration system. Finally, the present investigation concludes that the use of refrigerant R1234ze is much efficient than the other investigated refrigerants due to its low GWP and compressor discharge temperature, in spite of achieving better thermo-economic performances using R152a as subcooler refrigerant.
- 28 February 2020
- Published by Wiley in Journal of Thermal Science and Engineering Applications
- Vol. 12 (3) , 1-44
Exergy and Cost Optimization of a Two-Stage Refrigeration System Using Refrigerant R32 and R410A
An attempt has been made to investigate numerically a two-stage refrigeration system with flash intercooler of 50 kW cooling capacity using refrigerant R410A and its possible alternative R32. Development of the simulation model for the analysis of the system has been carried out in engineering equation solver considering the energetic, exergetic, economic, and environmental aspects. Evaporator and condenser temperatures have been varied from −50 °C to −25 °C and 40 °C to 55 °C, respectively, to carry out the simulation work. Co-efficient of performance (COP), exergetic efficiency, and plant cost rate are the three performance parameters computed in this present work. Results show that the performances of the system using R32 are comparable with those of the system using R410A. It is also observed that R32 shows slightly better thermo-economic performances at higher condenser temperature. Multi-objective optimization has also been carried out using the toolbox available for optimization in matlab to obtain the optimum performance and optimum operating conditions for both the refrigerants. Optimization results also show better thermo-economic performances of R32 over R410A though compressor discharge temperature is higher in case of R32.
- 28 February 2020
- Published by Wiley in Journal of Thermal Science and Engineering Applications
- Vol. 12 (3) , 1-44
Exergy and Cost Optimization of a Two-Stage Refrigeration System Using Refrigerant R32 and R410A
An attempt has been made to investigate numerically a two-stage refrigeration system with flash intercooler of 50 kW cooling capacity using refrigerant R410A and its possible alternative R32. Development of the simulation model for the analysis of the system has been carried out in engineering equation solver considering the energetic, exergetic, economic, and environmental aspects. Evaporator and condenser temperatures have been varied from −50 °C to −25 °C and 40 °C to 55 °C, respectively, to carry out the simulation work. Co-efficient of performance (COP), exergetic efficiency, and plant cost rate are the three performance parameters computed in this present work. Results show that the performances of the system using R32 are comparable with those of the system using R410A. It is also observed that R32 shows slightly better thermo-economic performances at higher condenser temperature. Multi-objective optimization has also been carried out using the toolbox available for optimization in matlab to obtain the optimum performance and optimum operating conditions for both the refrigerants. Optimization results also show better thermo-economic performances of R32 over R410A though compressor discharge temperature is higher in case of R32.
- 17 January 2020
- Published by Springer Nature
- p. 717-727
A Simplified Approach for the Rapid Evaluation of Thermodynamic Properties of Saturated Water and Steam
- 17 January 2020
- Published by Springer Nature
- p. 717-727
A Simplified Approach for the Rapid Evaluation of Thermodynamic Properties of Saturated Water and Steam
- Open Access
- 1 November 2019
- Published by Elsevier in Energy Reports
- Vol. 5, 639-648
A comparative study on the performance and emissions from a CI engine fuelled with water emulsified diesel prepared by mechanical homogenization and ultrasonic dispersion method
- 1 November 2019
- Published by Elsevier in Energy Reports
- Vol. 5, 639-648
Open AccessA comparative study on the performance and emissions from a CI engine fuelled with water emulsified diesel prepared by mechanical homogenization and ultrasonic dispersion method
- 28 August 2019
- Published by Springer Nature in Journal of Thermal Analysis and Calorimetry
- Vol. 139 (5) , 3247-3261
Thermo-economic analysis and multi-objective optimization of vapour cascade refrigeration system using different refrigerant combinations
- 28 August 2019
- Published by Springer Nature in Journal of Thermal Analysis and Calorimetry
- Vol. 139 (5) , 3247-3261
Thermo-economic analysis and multi-objective optimization of vapour cascade refrigeration system using different refrigerant combinations
- 28 June 2019
- Published by Springer Nature in International Journal of Air-Conditioning and Refrigeration
- Vol. 27 (02)
A Review on Energy and Exergy Analysis of Two-Stage Vapour Compression Refrigeration System
This paper presents a review on energy and exergy analysis of two-stage vapour compression refrigeration (VCR) system. The use of alternative refrigerants instead of conventional refrigerants has also been addressed. The governing equations for the energetic and exergetic analysis of two-stage VCR system have been identified and presented. Several experimental and numerical investigations and their findings on the performance of the two-stage VCR system available in the literature have been discussed in brief. Some of the results have also been reproduced as case studies.
- 28 June 2019
- Published by Springer Nature in International Journal of Air-Conditioning and Refrigeration
- Vol. 27 (02)
A Review on Energy and Exergy Analysis of Two-Stage Vapour Compression Refrigeration System
This paper presents a review on energy and exergy analysis of two-stage vapour compression refrigeration (VCR) system. The use of alternative refrigerants instead of conventional refrigerants has also been addressed. The governing equations for the energetic and exergetic analysis of two-stage VCR system have been identified and presented. Several experimental and numerical investigations and their findings on the performance of the two-stage VCR system available in the literature have been discussed in brief. Some of the results have also been reproduced as case studies.