Maria Margaretha Suliyanti
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Maria Margaretha Suliyanti has a total of 105 co-authors. Here are the top co-authors by number of shared publications:
- Koo Hendrik Kurniawan
Research Center of Maju Makmur Mandiri Foundation, Jakarta, Indonesia
34 shared publications - Marincan Pardede
Department of Electrical Engineering, University of Pelita Harapan, 1100 M.H. Thamrin Boulevard, Lippo Village, Tangerang 15811, Indonesia
31 shared publications - Rinda Hedwig
Computer Engineering Department, Faculty of Engineering, Bina Nusantara University, Jakarta, Indonesia
29 shared publications Kiichiro Kagawa
Research Center of Maju Makmur Mandiri Foundation Jakarta 11630 Indonesia
26 shared publications- Tjung Jie Lie
Research Center of Maju Makmur Mandiri Foundation, 40/80 Srengseng Raya, Jakarta 11630, Indonesia
25 shared publications - Syahrun Nur Abdulmadjid
Department of Physics, Faculty of Mathematics and Natural Sciences Universitas Syiah Kuala, Banda Aceh 23111, Indonesia
24 shared publications
Latest Publications
- 27 June 2024
- Published by Wiley in Chemphyschem
- Vol. 25 (16) , e202300843
In‐Situ Lithium Analysis In MgLi Alloys Using Laser‐Induced Breakdown Spectroscopy with a Compact Chamber
This study explores the feasibility of in situ Lithium (Li) analysis in Magnesium‐Lithium (MgLi) alloys using Laser‐Induced Breakdown Spectroscopy (LIBS). It focuses on two Li emission lines: Li I 670.8 nm (resonance) and Li I 610.4 nm (non‐resonance). Comparing characteristics at atmospheric and low pressures, self‐reversal signatures are observed in both emission lines at atmospheric pressure, complicating the analysis. Challenges in suppressing self‐reversal effect using laser energy and detection window adjustments are noted. To address this, a compact chamber (80 mm×50 mm×50 mm) with adjustable pressure (using a portable vacuum pump) is developed. Lowering the pressure significantly reduces self‐reversal effect, particularly for the Li I 610.4 nm line. This makes Li I 610.4 nm more suitable for analyzing high Lithium concentrations in MgLi alloys. Using standard samples, such as LA91 (8 % Li) and LA141 (14 % Li), the study successfully obtains Li I 610.4 nm spectra with proportional Li emission intensities. Even with a commercially affordable time‐integrated charge‐coupled device (CCD) detection system, the results indicate the efficacy of this approach for in situ Li analysis in MgLi alloys.
- 27 June 2024
- Published by Wiley in Chemphyschem
- Vol. 25 (16) , e202300843
In‐Situ Lithium Analysis In MgLi Alloys Using Laser‐Induced Breakdown Spectroscopy with a Compact Chamber
This study explores the feasibility of in situ Lithium (Li) analysis in Magnesium‐Lithium (MgLi) alloys using Laser‐Induced Breakdown Spectroscopy (LIBS). It focuses on two Li emission lines: Li I 670.8 nm (resonance) and Li I 610.4 nm (non‐resonance). Comparing characteristics at atmospheric and low pressures, self‐reversal signatures are observed in both emission lines at atmospheric pressure, complicating the analysis. Challenges in suppressing self‐reversal effect using laser energy and detection window adjustments are noted. To address this, a compact chamber (80 mm×50 mm×50 mm) with adjustable pressure (using a portable vacuum pump) is developed. Lowering the pressure significantly reduces self‐reversal effect, particularly for the Li I 610.4 nm line. This makes Li I 610.4 nm more suitable for analyzing high Lithium concentrations in MgLi alloys. Using standard samples, such as LA91 (8 % Li) and LA141 (14 % Li), the study successfully obtains Li I 610.4 nm spectra with proportional Li emission intensities. Even with a commercially affordable time‐integrated charge‐coupled device (CCD) detection system, the results indicate the efficacy of this approach for in situ Li analysis in MgLi alloys.
- Open Access
- 1 May 2023
- Published by IOP Publishing in Materials Research Express
- Vol. 10 (5) , 055305
Flexible fibrous structure of bacterial cellulose by synergic role carboxymethyl cellulose and glycerol for LiB polymer electrolyte
In this work, we report a flexible nanofibrous cellulose nanocomposite with great potential for lithium-ion battery (LiB) polymer electrolyte. Flexible and fibrous material is synthesized using a simple and easy technique by synergistically combining carboxymethyl cellulose (CMC) and glycerol (Gly). Flexible porous cellulose forms a three-dimensional network for the mobility of Li ions in the polymer electrolyte of LIB systems. We investigated the effect ionic liquid of flexible fibrous cellulose (BC-CMC-Gly) on the electrochemical properties. The surface interaction between Li ions and the porous network is a key parameter demonstrated by the Li-ion emission line at 610.37 nm using laser inductance breakdown spectroscopy (LiBS). The ionic conductivity of BC-CMC-Gly characterized by EIS measurement is about 1.1 × 10−3 S cm−1. According to linear sweep voltammetry (LSV), BC-CMC-Gly, with a potential window of 4.3 V, shows a more expansive window voltage than pure BC (2.75 V) and BC-CMC (3.3 V). This indicates that the electrochemical stability is good, as wide as the range of voltages that the electrode reactions define. The specific capacity of BC-CMC-Gly containing IL is very high, about 27.6 mAh g−1 compared to BC (7.4 mAh g−1) and BC-CMC (11,5 mAh g−1). All these findings clearly show that forming plasticized structures synergistically with CMC trapped in the BC structure results in the largest Li-ion adsorption capacity and electrochemical performance improvement. Thermal stability up to 200 °C and electrolyte uptake of approx. 189% are the beneficial properties of BC-CMC-Gly fibrous cellulose for LiB electrolyte polymer.
- 1 May 2023
- Published by IOP Publishing in Materials Research Express
- Vol. 10 (5) , 055305
Open AccessFlexible fibrous structure of bacterial cellulose by synergic role carboxymethyl cellulose and glycerol for LiB polymer electrolyte
In this work, we report a flexible nanofibrous cellulose nanocomposite with great potential for lithium-ion battery (LiB) polymer electrolyte. Flexible and fibrous material is synthesized using a simple and easy technique by synergistically combining carboxymethyl cellulose (CMC) and glycerol (Gly). Flexible porous cellulose forms a three-dimensional network for the mobility of Li ions in the polymer electrolyte of LIB systems. We investigated the effect ionic liquid of flexible fibrous cellulose (BC-CMC-Gly) on the electrochemical properties. The surface interaction between Li ions and the porous network is a key parameter demonstrated by the Li-ion emission line at 610.37 nm using laser inductance breakdown spectroscopy (LiBS). The ionic conductivity of BC-CMC-Gly characterized by EIS measurement is about 1.1 × 10−3 S cm−1. According to linear sweep voltammetry (LSV), BC-CMC-Gly, with a potential window of 4.3 V, shows a more expansive window voltage than pure BC (2.75 V) and BC-CMC (3.3 V). This indicates that the electrochemical stability is good, as wide as the range of voltages that the electrode reactions define. The specific capacity of BC-CMC-Gly containing IL is very high, about 27.6 mAh g−1 compared to BC (7.4 mAh g−1) and BC-CMC (11,5 mAh g−1). All these findings clearly show that forming plasticized structures synergistically with CMC trapped in the BC structure results in the largest Li-ion adsorption capacity and electrochemical performance improvement. Thermal stability up to 200 °C and electrolyte uptake of approx. 189% are the beneficial properties of BC-CMC-Gly fibrous cellulose for LiB electrolyte polymer.
- Open Access
- 9 November 2021
- Published by Springer Nature in Scientific Reports
- Vol. 11 (1) , 1-10
High sensitivity hydrogen analysis in zircaloy-4 using helium-assisted excitation laser-induced breakdown spectroscopy
High-sensitivity detection of hydrogen (H) contained in zircaloy-4, a commonly used material for nuclear fuel containers, is crucial in a nuclear power plant. Currently, H detection is performed via gas chromatography, which is an offline and destructive method. In this study, we developed a technique based on metastable excited-state He-assisted excitation to achieve excellent quality of H emission spectra in double-pulse orthogonal laser-induced breakdown spectroscopy (LIBS). The production of metastable excited-state He atoms is optimized by using LiF as sub-target material. The results show a narrow full-width-at-half-maximum of 0.5 Å for the H I 656.2 nm emission line, with a detection limit as low as 0.51 mg/kg. Thus, using this novel online method, H in zircaloy-4 can be detected efficiently, even at very low concentrations.
- 9 November 2021
- Published by Springer Nature in Scientific Reports
- Vol. 11 (1) , 1-10
Open AccessHigh sensitivity hydrogen analysis in zircaloy-4 using helium-assisted excitation laser-induced breakdown spectroscopy
High-sensitivity detection of hydrogen (H) contained in zircaloy-4, a commonly used material for nuclear fuel containers, is crucial in a nuclear power plant. Currently, H detection is performed via gas chromatography, which is an offline and destructive method. In this study, we developed a technique based on metastable excited-state He-assisted excitation to achieve excellent quality of H emission spectra in double-pulse orthogonal laser-induced breakdown spectroscopy (LIBS). The production of metastable excited-state He atoms is optimized by using LiF as sub-target material. The results show a narrow full-width-at-half-maximum of 0.5 Å for the H I 656.2 nm emission line, with a detection limit as low as 0.51 mg/kg. Thus, using this novel online method, H in zircaloy-4 can be detected efficiently, even at very low concentrations.
- Open Access
- 2 April 2021
- Published by AIP Publishing in AIP Conference Proceedings
- Vol. 2331 (1) , 030026
Detecting pyrethroid pesticide residues in cocoa products using laser induced breakdown spectroscopy
One of the main problems in cocoa products is the contamination of pesticide residues, especially pyrethroid pesticides. Therefore, a rapid and accurate detection of pyrethroid group pesticides is critically important to maintain the quality of fermented cocoa products. Conventional chemical methods to detect pesticide residues require complicated and time-consuming sample preparation. Therefore, it is necessary to develop new methods that are faster and easier. Laser-induced breakdown spectroscopy (LIBS) has been proven to be used to detect residual content pesticides in some food products. Testing of pyrethroid pesticide residues on fermented cocoa products using LIBS is possible because pyrethroid has several specific halogen elements that do not exist in fermented cocoa products that can be measured through LIBS. We report detection of cypermethrin (a synthetic pyrethroid pesticide) residue as low as 1wt.% using LIBS spectral line of chlorine at 837.6 nm.
- 2 April 2021
- Published by AIP Publishing in AIP Conference Proceedings
- Vol. 2331 (1) , 030026
Open AccessDetecting pyrethroid pesticide residues in cocoa products using laser induced breakdown spectroscopy
One of the main problems in cocoa products is the contamination of pesticide residues, especially pyrethroid pesticides. Therefore, a rapid and accurate detection of pyrethroid group pesticides is critically important to maintain the quality of fermented cocoa products. Conventional chemical methods to detect pesticide residues require complicated and time-consuming sample preparation. Therefore, it is necessary to develop new methods that are faster and easier. Laser-induced breakdown spectroscopy (LIBS) has been proven to be used to detect residual content pesticides in some food products. Testing of pyrethroid pesticide residues on fermented cocoa products using LIBS is possible because pyrethroid has several specific halogen elements that do not exist in fermented cocoa products that can be measured through LIBS. We report detection of cypermethrin (a synthetic pyrethroid pesticide) residue as low as 1wt.% using LIBS spectral line of chlorine at 837.6 nm.
- Open Access
- 1 February 2020
- Published by Laser Institute of America in Journal of Laser Applications
- Vol. 32 (1) , 012014
Comparison of excitation mechanisms and the corresponding emission spectra in femto second and nano second laser-induced breakdown spectroscopy in reduced ambient air and their performances in surface analysis
A study is conducted on the detailed static and dynamic characteristics of plasma and the resulting emission spectral qualities generated by a femtosecond (fs) laser irradiation compared with those produced by nanosecond (ns) laser irradiation at a reduced ambient air pressure of 0.65 kPa. It is shown that both plasmas feature a tiny primary and a much larger secondary plasmas, which share the same hemispherical shape of roughly the same size at the appropriately chosen pulse energies. The resulted emission spectra in both cases exhibit one of the shock wave characteristics marked by a much stronger Zn triplet than its singlet emission lines. Further measurement of log(r)–log(t) of Cu I 521.8 nm emission line yields a slope of around 0.4, which is in good agreement with Sedov's equation derived for shock wave plasma. While exhibiting similar pressure-dependent emission intensities of Cu and Zn emission lines, the fs induced emission intensities are consistently lower than those induced by ns laser plasma. The estimated average temperature of the ns laser induced plasma (10 200 K) is only slightly higher than that induced by the fs laser (9800 K). The lower integrated emission intensity of fs plasma is related to previously reported lower electron density in fs laser-induced breakdown spectroscopy (fs-LIBS) and the faster decay of the associated continuum background, implying rapid diminution of ionized atoms and hence lower integrated emission intensity. Therefore, apart from cases demanding minimal surface damages, the simpler and less expensive ns-LIBS should be considered as a more favorable alternative for spectrochemical analysis. However, the applications to surface analysis do show that the fs laser offers higher detection sensitivity. A judicial selection is, therefore, strongly recommended.
- 1 February 2020
- Published by Laser Institute of America in Journal of Laser Applications
- Vol. 32 (1) , 012014
Open AccessComparison of excitation mechanisms and the corresponding emission spectra in femto second and nano second laser-induced breakdown spectroscopy in reduced ambient air and their performances in surface analysis
A study is conducted on the detailed static and dynamic characteristics of plasma and the resulting emission spectral qualities generated by a femtosecond (fs) laser irradiation compared with those produced by nanosecond (ns) laser irradiation at a reduced ambient air pressure of 0.65 kPa. It is shown that both plasmas feature a tiny primary and a much larger secondary plasmas, which share the same hemispherical shape of roughly the same size at the appropriately chosen pulse energies. The resulted emission spectra in both cases exhibit one of the shock wave characteristics marked by a much stronger Zn triplet than its singlet emission lines. Further measurement of log(r)–log(t) of Cu I 521.8 nm emission line yields a slope of around 0.4, which is in good agreement with Sedov's equation derived for shock wave plasma. While exhibiting similar pressure-dependent emission intensities of Cu and Zn emission lines, the fs induced emission intensities are consistently lower than those induced by ns laser plasma. The estimated average temperature of the ns laser induced plasma (10 200 K) is only slightly higher than that induced by the fs laser (9800 K). The lower integrated emission intensity of fs plasma is related to previously reported lower electron density in fs laser-induced breakdown spectroscopy (fs-LIBS) and the faster decay of the associated continuum background, implying rapid diminution of ionized atoms and hence lower integrated emission intensity. Therefore, apart from cases demanding minimal surface damages, the simpler and less expensive ns-LIBS should be considered as a more favorable alternative for spectrochemical analysis. However, the applications to surface analysis do show that the fs laser offers higher detection sensitivity. A judicial selection is, therefore, strongly recommended.
- Open Access
- 1 August 2019
- Published by IOP Publishing in Journal of Physics: Conference Series
- Vol. 1245 (1) , 012035
Antibacterial activity of ZnO nanoparticles fabricated using laser ablation in solution technique
The zinc oxide (ZnO) nanoparticles have been produced by using laser ablation in solution technique, resulting nanoparticles with hexagonal wurtzite structure and the size range of 20 – 50 nm. The optical characterization has predicted the nanoparticles band gap at least 3.16 eV. The ZnO nanoparticles were employed as an antibacterial agent for the growth of Escherichia coli (E. coli), and it shows a great potential. Total plate count (TPC) analysis was conducted by applying the ZnO nanoparticles with different concentration of 5%, 10%, 15%, 20%, 25% and 30% (portion of bacteria medium). The 5% concentration could reduce more than half of the E. coli population after 24 hours incubation time. There was no living bacteria detected for 20%, 25% and 30% ZnO concentration.
- 1 August 2019
- Published by IOP Publishing in Journal of Physics: Conference Series
- Vol. 1245 (1) , 012035
Open AccessAntibacterial activity of ZnO nanoparticles fabricated using laser ablation in solution technique
The zinc oxide (ZnO) nanoparticles have been produced by using laser ablation in solution technique, resulting nanoparticles with hexagonal wurtzite structure and the size range of 20 – 50 nm. The optical characterization has predicted the nanoparticles band gap at least 3.16 eV. The ZnO nanoparticles were employed as an antibacterial agent for the growth of Escherichia coli (E. coli), and it shows a great potential. Total plate count (TPC) analysis was conducted by applying the ZnO nanoparticles with different concentration of 5%, 10%, 15%, 20%, 25% and 30% (portion of bacteria medium). The 5% concentration could reduce more than half of the E. coli population after 24 hours incubation time. There was no living bacteria detected for 20%, 25% and 30% ZnO concentration.
- Open Access
- 1 March 2019
- Published by IOP Publishing in Journal of Physics: Conference Series
- Vol. 1191 (1) , 012010
Stabilization of Au-Ag Nanoalloys with Polyvinylpyrrolidone (PVP) as Capping Agent
Van der Waals attraction between nanoparticles will create aggregation, therefore, adding a capping agent is needed to stabilize the nanoparticles. We have synthesized Au50Ag50 nanoalloys from a mixture of silver and gold metal ions using a femtosecond laser irradiated for 5, 10, and 15 minutes. The process occurred in a water-only medium and in a water medium added with 0.01 wt% polyvinylpyrrolidone (PVP). Only Au50Ag50 with 5 minutes irradiation times that was characterized by TEM. From TEM result, PVP was proven to generate stabilization of the nanoparticles. It was confirmed that the nanoparticles in Au-Ag nanoalloys with PVP are more disperse than the Au-Ag nanoalloys without PVP. From the result, the particle size of Au-Ag nanoalloys without PVP is 10.72 nm, and 7.94 nm with PVP. This indicates that not only reducing the van der Waals attractive forces and stabilizing the nanoparticles, PVP can also reduce the particle size.
- 1 March 2019
- Published by IOP Publishing in Journal of Physics: Conference Series
- Vol. 1191 (1) , 012010
Open AccessStabilization of Au-Ag Nanoalloys with Polyvinylpyrrolidone (PVP) as Capping Agent
Van der Waals attraction between nanoparticles will create aggregation, therefore, adding a capping agent is needed to stabilize the nanoparticles. We have synthesized Au50Ag50 nanoalloys from a mixture of silver and gold metal ions using a femtosecond laser irradiated for 5, 10, and 15 minutes. The process occurred in a water-only medium and in a water medium added with 0.01 wt% polyvinylpyrrolidone (PVP). Only Au50Ag50 with 5 minutes irradiation times that was characterized by TEM. From TEM result, PVP was proven to generate stabilization of the nanoparticles. It was confirmed that the nanoparticles in Au-Ag nanoalloys with PVP are more disperse than the Au-Ag nanoalloys without PVP. From the result, the particle size of Au-Ag nanoalloys without PVP is 10.72 nm, and 7.94 nm with PVP. This indicates that not only reducing the van der Waals attractive forces and stabilizing the nanoparticles, PVP can also reduce the particle size.
- 1 January 2019
- Published by Elsevier in Spectrochimica Acta Part B: Atomic Spectroscopy
- Vol. 151, 26-32
Enhancement of carbon detection sensitivity in laser induced breakdown spectroscopy with low pressure ambient helium gas
- 1 January 2019
- Published by Elsevier in Spectrochimica Acta Part B: Atomic Spectroscopy
- Vol. 151, 26-32
Enhancement of carbon detection sensitivity in laser induced breakdown spectroscopy with low pressure ambient helium gas
- 1 June 2018
- Published by Elsevier in Journal of Luminescence
- Vol. 198, 215-219
Concentration effect on optical properties of carbon dots at room temperature
- 1 June 2018
- Published by Elsevier in Journal of Luminescence
- Vol. 198, 215-219
Concentration effect on optical properties of carbon dots at room temperature