SRSergio Rescia

Sergio Rescia

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Sergio Rescia has a total of 378 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    The forward physics facility: Physics opportunities and conceptual design

    by Luis A. Anchordoqui, John Kenneth Anders, Akitaka Ariga, Tomoko Ariga, David Asner, Jeremy Atkinson, Alan J. Barr, Larry Bartoszek, Brian Batell, Hans Peter Beck, et al.


  • Ultra-pure nickel for structural components of low-radioactivity instruments

    by T.J. Roosendaal, C.T. Overman, G.S. Ortega, T.D. Schlieder, N.D. Rocco, L.K.S. Horkley, K.P. Hobbs, K. Harouaka, J.L. Orrell, P. Acharya, et al.


  • Open Access

    Ultra-pure Nickel for Structural Components of Low-Radioactivity Instruments

    by T. J. Roosendaal, C. T. Overman, G. S. Ortega, T. D. Schlieder, N. D. Rocco, L. K. S. Horkley, K. P. Hobbs, K. Harouaka, J. L. Orrell, P. Acharya, et al.

    The next generation of rare-event search experiments in nuclear and particle physics demand structural materials combining exceptional mechanical strength with ultra-low levels of radioactive contamination. This study evaluates chemical vapor deposition (CVD) nickel as a candidate structural material for such applications. Manufacturer-supplied CVD Ni grown on aluminum substrates underwent tensile testing before and after welding alongside standard Ni samples. CVD Ni exhibited a planar tensile strength of ~600 MPa, significantly surpassing standard nickel. However, welding and heat treatment were found to reduce the tensile strength to levels comparable to standard Ni, with observed porosity in the welds likely contributing to this reduction. Material assay via inductively coupled plasma mass spectrometry (ICP-MS) employing isotope-dilution produced measured bulk concentration of 232-Th, 238-U, and nat-K at the levels of ~70 ppq, <100 ppq, and ~900 ppt, respectively, which is the lowest reported in nickel. Surface-etch profiling uncovered higher concentrations of these contaminants extending ~10 micrometer beneath the surface, likely associated with the aluminum growth substrate. The results reported are compared to the one other well documented usage of CVD Ni in a low radioactive background physics research experiment and a discussion is provided on how the currently reported results may arise from changes in CVD fabrication or testing process. These results establish CVD Ni as a promising low-radioactivity structural material, while outlining the need for further development in welding and surface cleaning techniques to fully realize its potential in large-scale, low radioactive background rare-event search experiments.

  • Open Access

    Cryogenic Front-End ASICs for Low-Noise Readout of Charge Signals

    by Prashansa Mukim, Gabriella A. Carini, Hucheng Chen, Grzegorz W. Deptuch, Shanshan Gao, Gianluigi De Geronimo, Soumyajit Mandal, Venkata Narasimha Manyam, Veljko Radeka, Sergio Rescia

    This paper presents design details and measurement results of LArASIC, a front-end application specific integrated circuit (ASIC) designed for low-noise readout of charge signals generated in neutrino study experiments within liquid argon time projection chambers. LArASIC comprises of 16-channels of programmable charge amplification and pulse shaping stages that provide a voltage readout proportional to the input charge and was optimized for operation at liquid argon temperature, i.e., 89K. The chip was fabricated in a 180nm CMOS process. Measurements at liquid nitrogen temperature, i.e., 77K, indicate that the channel outputs have high linearity (INL $\mu $ s and a detector capacitance of 150pF, and a worst-case inter-channel cross-talk of 0.35%. The paper also presents design choices made in the process of migrating LArASIC to CHARMS, an ASIC to be fabricated in a 65nm process that includes all features provided by LArASIC, along with additional digital programmability for improved robustness and flexibility. CHARMS is intended for use in future high-energy physics experiments that require high-resolution charge or light readout with shorter pulse peaking times.


  • Open Access

    Quantum Sensing for High Energy Physics

    by Karl van Bibber, Malcolm Boshier, Marcel Demarteau, Matt Dietrich, Maurice Garcia-Sciveres, Salman Habib, Hannes Hubmayr, Kent Irwin, Akito Kusaka, Joe Lykken, et al.

    The Coordinating Panel for Advanced Detectors (CPAD) of the APS Division of Particles and Fields organized a first workshop on Quantum Sensing for High Energy Physics (HEP) in early December 2017 at Argonne National Laboratory. Participants from universities and national labs were drawn from the intersecting fields of Quantum Information Science (QIS), high energy physics, atomic, molecular and optical physics, condensed matter physics, nuclear physics and materials science. Quantum-enabled science and technology has seen rapid technical advances and growing national interest and investments over the last few years. The goal of the workshop was to bring the various communities together to investigate pathways to integrate the expertise of these two disciplines to accelerate the mutual advancement of scientific progress.


  • Design and R&D of RICH detectors for EIC experiments

    by A. Del Dotto, C.-P. Wong, L. Allison, M. Awadi, B. Azmoun, F. Barbosa, W. Brooks, T. Cao, M. Chiu, E. Cisbani, et al.


  • Origin of Low-Energy Spurious Peaks in Spectroscopic Measurements With Silicon Detectors

    by Gabriele Giacomini, Alan Huber, Robert Redus, Sergio Rescia

    When an uncollimated radioactive X-ray source illuminates a silicon PIN sensor, some ionizing events are generated in the nonimplanted gap between the active area of the sensor and the guard rings (GRs). Carriers can be collected by floating electrodes, i.e., electron accumulation layers at the silicon/oxide interface, and floating GRs. The crosstalk signals generated by these events create spurious peaks, replicas of the main peaks at either lower amplitude or of opposite polarity. We explain this phenomenon as crosstalk caused by charge collected on these floating electrodes, which can be analyzed by means of an extension of Ramo theorem.


  • PN-CDDs for the XMM satellite mission

    by Heinrich W Braeuninger, Gerhard Lutz, Norbert Meidinger, Peter Predehl, C Reppin, Wolfgang Schreiber, Lothar Strueder, J Truemper, E Kendziorra, R Staubert, et al.

    Recent results on the on-chip electronics, transfer properties, and radiation entrance window of pn-CCDs are presented. With recently fabricated devices, an improved charge transfer efficiency per pixel of 0.9995 and an energy resolution of the CCD output stage of 5 e(-) rms have been measured. This performance is achieved without a degradation of other characteristics of the devices, such as an X-ray efficiency of 90 percent at 10 keV, more than a factor of 1000 better time resolution in the full frame mode in comparison with all other CCD concepts, and a one-dimensional spatial resolution of 24 microsec in the timing mode. The use of pn-junctions instead of MOS structures makes the devices intrinsically radiation resistant.