RPRoelf R. Postema

Roelf R. Postema

*This is an algorithmically generated author record based on publicly available information.

Roelf R. Postema has a total of 55 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Design and Validation of a Grasping Force Measuring Vibrotactile Feedback Add-On for Laparoscopic Instruments

    by Jan-Willem Klok, Yannick Smits, Roelf Postema, Asþor T. Steinþorsson, Jenny Dankelman, Tim Horeman

    Objective: Grasping force control is crucial for safe laparoscopic surgery. However, force feedback is limited as haptic information on grasping strength and tissue stiffness is mostly lost due to internal instrument backlash and friction. This increases tissue trauma risk as excessive grasping forces can lead to (postoperative) complications. This study aims to develop a grasping force feedback providing add-on for a laparoscopic grasper and to validate its impact on skills acquisition in basic laparoscopic skills training. Method: The ShaftFlex, a shaft-based grasping force measurement system providing feedback was designed as an add-on for standard reusable instruments. It consists of a compliant element deflecting proportionally to the applied grasping force, and a Hall sensor measuring that deflection. Influence on skills acquisition was evaluated in a comparative study where novices were divided into a Feedback and No feedback group, performing five training trials of a silicon torus transfer boxtrainer task. Afterwards, both groups performed a post-training task without feedback. Grasping force, time to completion and number of errors were measured. Results: There was a significant difference in mean grasping force between groups for all training trials and the post-training trial. In the Feedback group, there was no significant increase in grasping force when feedback was removed. Conclusion: The ShaftFlex working principle provided a feasible, sustainable method to measure grasping forces exerted by a laparoscopic grasper, enabling immediate haptic feedback. It potentially enhances objective skill assessment, providing feedback on training performance. In a clinical context, the ShaftFlex might be useful in surgery where delicate tissue is grasped.


  • Open Access

    A pre-clinical application study of the SATA-LRS laparoscopic instrument in a human cadaver model

    by Tomas Lenssen, Roelf R. Postema, Christian Camenzuli, Jean Calleja-Agius, Jenny Dankelman, Tim Horeman-Franse

    To validate whether the SATA-LRS, a novel reusable articulating laparoscopic instrument, fits surgical practice, a pre-clinical study was performed. Thirteen medical doctors used the instrument in a laparoscopic endoscopic inguinal hernia repair (TEP)-like task inside a cadaver. A set of sensors on the instrument handle detected motion and articulation of the instrument tip. Data from the sensors and video recordings were used to assess the amount and type of movement of the instrument and the time spent on tasks. questionnaire was used to gain insight into the participants' perception of the contextual factors. There was no difference between task time and instrument tip velocities when using articulation (or not) and all participants used articulation at least half of the task time. Instrument-handle movement, indicating the user's hand and arm movement, was significantly reduced when using articulation. The questionnaire indicated strong acceptance of the instrument and the experimental setup, and a desire to use the instrument in surgery by most participants. The added articulation feature of the SATA-LRS instrument was deemed beneficial by the participants, showed no increased handling complexity or time spent on the task and was used frequently when enabled, indicating intuitiveness.


  • Open Access

    Design and Evaluation of a Balanced Compliant Laparoscopic Grasper

    by Jan-Willem Klok, Roelf Postema, Asþor T. Steinþorsson, Jenny Dankelman, Tim Horeman

    Objective : In laparoscopic surgery, quality of haptic feedback is reduced compared to conventional surgery, leading to unintentional tissue damage during grasping. From the perspective of haptics, poor mechanical design of laparoscopic instrument joints induces friction and a nonlinear actuation - tip force relation. In this study, a novel laparoscopic grasper using compliant joints and a magnetic balancer is presented, and the reduction in hysteresis and friction is evaluated. Methods & Results : The hysteresis loop of the novel compliant grasper and two conventional laparoscopic graspers (high quality leading commercial brand and low quality unbranded grasper) were measured. In order to assess quality of haptic feedback, the lowest grasper tip load perceivable by instrument users was measured with the novel and the conventional laparoscopic graspers. The hysteresis loop measurement yielded a mechanical efficiency of 43% for the novel grasper, compared to- 25% and 23% for the Aesculap and the unbranded grasper, respectively. The forces perceivable by the user through the novel grasper were significantly lower (mean 1.37N, SD 0.44N) than those of conventional graspers (mean 2.15N, SD 0.71N and mean 2.65N, SD 1.20N, respectively). Conclusions : The balanced compliant grasper technology has the ability to improve the quality of haptic feedback compared to conventional laparoscopic graspers. Research is needed to relate these results to soft and delicate tissue grasping in a clinical setting, for which this instrument is intended.


  • Open Access

    Pre-clinical evaluation of the new veress needle+ mechanism on thiel-embalmed bodies: a controlled crossover study – Experimental research

    by Roelf R. Postema, Sem Frederik Hardon, David Msc Cefai, Jenny Msc Dankelman, Frank-Willem Jansen, Christian Md Frcs(Edin) Camenzuli, Jean Md Msc Frcog Frcpi Calleja-Agius, Tim Msc Horeman-Franse

    Background: Veress needles (VN) are commonly used in establishing pneumoperitoneum in laparoscopic surgery. Previously, a VN with a new safety mechanism ‘VeressPLUS’ needle (VN+) was developed to reduce the amount of overshoot. Methods: Eighteen participants (novices, intermediates, and experts) performed in total of 248 insertions in a systematic way on Thiel-embalmed bodies with wide and small bore versions of the conventional VN (VNc) and the VN+. Insertion depth was measured by recording the graduations on the needle under direct laparoscopic vision. Results: Participants graded the bodies and the procedures as lifelike. Overall, a significant reduction (PPP<0.001) for female participants compared to male. Conclusion: This study indicated that the VN+ significantly reduced the insertion depth in all tested conditions. Whether the difference between female and male performance can be linked to differences in muscle control or arm mass should be further investigated. Useful technical information was gathered from this study to further improve the VN+.


  • Open Access

    A novel Veress needle mechanism that reduces overshooting after puncturing the abdominal wall

    by Roelf R. Postema, David Cefai, Bart van Straten, Rein Miedema, Latifa Lesmana Hardjo, Jenny Dankelman, Felix Nickel, Tim Horeman-Franse

    Background: Complications that occur in laparoscopic surgery are often associated with the initial entry into the peritoneal cavity. The literature reported incidences of Veress needle (VN) injuries of e.g. 0.31% and 0.23%. In a 2010 national survey of laparoscopic entry techniques in the Canadian General Surgical practice, 57.3% of respondents had either experienced or witnessed a serious laparoscopic entry complication like bowel perforation and vascular injury. As those complications are potentially life threatening and should be avoided at all costs, improving safety of this initial action is paramount. Methods: Based on a bare minimum design approach with focus on function expansion of existing components, a new Safety mechanism was developed for the VN that decreases the risks of VN overshooting. The mechanism works by preventing the puncturing acceleration of the tip of the VN by decoupling the surgeon’s hand from the VN immediately after entering the abdomen. Results: Based on a set of requirements, a first prototype of the VN+ with force decoupling safety mechanism is presented and evaluated on an ex vivo porcine abdominal wall tissue model in a custom setup. The experiments conducted by two novices and one experienced surgeon indicated a significant difference between the attempts with a standard, conventional working VN (41.4 mm [37.5–45 mm]) and VN+ with decoupling mechanism (20.8 mm [17.5–22.5 mm]) of p < 0.001. Conclusion: A new decoupling safety mechanism was integrated successfully in a standard VN resulting in a VN+ . The results from the pilot study indicate that this new VN+ reduces overshooting with a minimum of 50% in a standardised ex vivo setting on fresh porcine abdominal wall specimens.


  • Open Access

    Haptic exploration improves performance of a laparoscopic training task

    by Roelf R. Postema, Leonie A. van Gastel, Sem F. Hardon, H. Jaap Bonjer, Tim Horeman

    Background: Laparoscopy has reduced tactile and visual feedback compared to open surgery. There is increasing evidence that visual and haptic information converge to form a more robust mental representation of an object. We investigated whether tactile exploration of an object prior to executing a laparoscopic action on it improves performance. Methods: A prospective cohort study with 20 medical students randomized in two different groups was conducted. A silicone ileocecal model, on which a laparoscopic action had to be performed, was used inside an outside a ForceSense box trainer. During the pre-test, students either did a combined manual and visual exploration or only visual exploration of the caecum model. To track performance during the trials of the study we used force, motion and time parameters as representatives of technical skills development. The final trial data were used for statistical comparison between groups. Results: All included time and motion parameters did not show any clear differences between groups. However, the force parameters Mean force non-zero (p = 004), Maximal force (p = 0.01) Maximal impulse (p = 0.02), Force volume (p = 0.02) and SD force (p = 0.01) showed significant lower values in favour of the tactile exploration group for the final trials. Conclusions: By adding haptic sensation to the existing visual information during training of laparoscopic tasks on life-like models, tissue manipulation skills improve during training.


  • Open Access

    A Case of Chronic Appendicopathy Caused by Parasitic Infection

    by A.S. Ramsaransing, R.R. Postema, J.L. Simons

    Parasitic infection of the appendix is rarely seen, but should be considered in patients with symptoms of chronic appendicitis. It is rarely associated with histological inflammation of the appendix, therefore radiographic imaging, performed during initial workup, remains unremarkable most of the time.


    • 14 June 2008
      • Vol. 152  (24) , 1387-90

    [Chronic pain due to a retained guidewire following endovascular laser therapy for varicose veins].

    by J R Kichari, R Salomonsz, Roelf Postema

    A 37-year-old woman was referred to the emergency room with pain in the right hemithorax and increasing dyspnoea. She also suffered from aggravating diffuse chronic pain in the body. The pain had started one year previously following endovascular laser therapy (EVLT) for varicose veins at a private clinic. Radiography showed metal-like wires throughout the body, even in her heart. She underwent transluminal percutaneous intervention to remove the guide wire-fragments and a thoracotomy for a subsequent tamponade of the heart. Although most studies report that EVLT is a safe therapeutic option for treating varicose veins and that complications are mostly self-limiting, this case shows that in inexperienced hands this procedure can cause severe iatrogenic damage.

  • Congenital Diaphragmatic Hernia and Situs Inversus Totalis

    by Coranne D. Tesselaar, Roelf R. Postema, Marieke F. van Dooren, Karel Allegaert, Dick Tibboel