RNRoberto Zenhei Nakazato

Roberto Zenhei Nakazato

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Roberto Zenhei Nakazato has a total of 111 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Electrochemical corrosion mechanisms of Zr–Nb and Zr–Sn alloys with different Fe content using classical, noise, and wavelet-based methods: a statistical approach

    by Alexandre Roberto Soares, Rafael Santos, Guilherme Pennachin Sakamiti, Antônio dos Reis de Faria Neto, Heloísa Andrea Acciari, Roberto Zenhei Nakazato

    This study investigates the composition–property relationship governing the electrochemical behavior and corrosion resistance for Zr–Nb and Zr–Sn alloys with iron (Fe) contents: 300, 400, and 600 ppm (Zr–Nb), and 1100 ppm (Zr–Sn). An integrated experimental approach combining Open Circuit Potential (OCP), Linear Sweep Voltammetry (LSV), Electrochemical Impedance Spectroscopy (EIS), and Electrochemical Noise (ECN), supported by statistical analysis and multiscale time–frequency methods based on discrete wavelet transforms, was employed to evaluate passive film protectiveness and stability. The results reveal a significant and non-linear influence of Fe content on the corrosion behavior of Zr–Nb alloys and modulates the frequency distribution of electrochemical noise, indicating a mechanistic role in repassivation dynamics. Increasing Fe content shifts the wavelet energy distribution from low-frequency to high-frequency coefficients, indicating a transition from steady-state passivation to intermittent repassivation. This transition is accompanied by increased average polarization resistance and reduced corrosion current densities, albeit with greater statistical dispersion. The Zr-Nb alloy with 600 ppm Fe exhibited pronounced electrochemical noise dispersion and intermittent localized transients, highest polarization resistance (~3.1 MΩ·cm2) and highest statistical dispersion (CV > 160%), attributed to passive film rupture followed by rapid repassivation. These results demonstrate that Fe content acts as an electrochemical modifier of passive film stability in zirconium alloys, governing both passive film protectiveness and dynamic stability, emphasizing the relevance of ECN and wavelet analysis for advanced materials qualification.

  • Open Access

    Electrochemical corrosion analysis of Zr–Nb and Zr–Sn alloys with different Fe content using classical, noise, and wavelet-based methods: a statistical approach

    by Alexandre Roberto Soares, Rafael Santos, Guilherme Pennachin Sakamiti, Antônio dos Reis de Faria Neto, Heloísa Andrea Acciari, Roberto Zenhei Nakazato

    This study investigates the composition–property relationship governing the electrochemical behavior and corrosion resistance for Zr–Nb and Zr–Sn alloys with iron (Fe) contents: 300, 400, and 600 ppm (Zr–Nb), and 1100 ppm (Zr–Sn). An integrated experimental approach combining Open Circuit Potential (OCP), Linear Sweep Voltammetry (LSV), Electrochemical Impedance Spectroscopy (EIS), and Electrochemical Noise (ECN), supported by statistical analysis and multiscale time–frequency methods based on discrete wavelet transforms, was employed to evaluate passive film protectiveness and stability. The results reveal a significant and non-linear influence of Fe content on the corrosion behavior of Zr–Nb alloys and modulates the frequency distribution of electrochemical noise, indicating a mechanistic role in repassivation dynamics. Increasing Fe content shifts the wavelet energy distribution from low-frequency to high-frequency coefficients, indicating a transition from steady-state passivation to intermittent repassivation. This transition is accompanied by increased average polarization resistance and reduced corrosion current densities, albeit with greater statistical dispersion. The Zr-Nb alloy with 600 ppm Fe exhibited pronounced electrochemical noise dispersion and intermittent localized transients, highest polarization resistance (~3.1 MΩ·cm2) and highest statistical dispersion (CV > 160%), attributed to passive film rupture followed by rapid repassivation. These results demonstrate that corrosion resistance in zirconium alloys for nuclear applications is governed by both passive film protectiveness and dynamic stability, emphasizing the relevance of combined ECN and wavelet analysis for advanced materials qualification.

  • Open Access

    Fretting Wear and Corrosion Behavior of the Fe‐35Mn Biodegradable Alloy for Biomedical Applications

    by Kerolene Barboza da Silva, Caio Pascotti Valem, S. Sudhagara Rajan, Vasanth Gopal, Praveenkumar Kesavan, Roberto Zenhei Nakazato, Geetha Manivasagam, Ana Paula Rosifini Alves

    The biodegradable Fe‐35Mn alloy has emerged as a promising material for temporary implants due to its excellent mechanical, degradation, magnetic, and biocompatibility properties. Despite these advantages, its in vivo performance can be affected by factors such as friction, wear, and corrosive environments, compromising long‐term stability. This study aimed to evaluate the corrosion and tribological wear behavior of the Fe‐35Mn alloy using pure Fe as the control group. Characterization was conducted using XRD, Vickers microhardness, and OM. Corrosion resistance was assessed through potentiodynamic polarization, and fretting wear behavior was investigated under simulated micromotion conditions. The addition of Mn promoted the formation of a predominantly austenitic microstructure, resulting in increased hardness. The alloy exhibited a higher degradation rate and tribological stability. Its coefficient of friction stabilized more rapidly, and wear mark analysis revealed reduced depth and lower material loss. The results reinforce the potential of the alloy for applications in physiological environments subjected to mechanical loading and dynamic conditions.

  • Open Access

    Electrochemical corrosion analysis of Zr–Nb and Zr–Sn alloys using classical, noise, and wavelet-based methods

    by Alexandre Roberto Soares, Guilherme Pennachin Sakamiti, Antônio dos Reis de Faria Neto, Heloísa Andrea Acciari, Roberto Zenhei Nakazato

    This study investigates the electrochemical behavior and resistance of zirconium-based alloys in the Zr–Nb and Zr–Sn systems with different iron (Fe) contents: 300, 400, and 600 ppm for Zr–Nb alloys, and 1100 ppm for a Zr–Sn. An integrated experimental approach combining Open Circuit Potential (OCP), Linear Sweep Voltammetry (LSV), Electrochemical Impedance Spectroscopy (EIS), and Electrochemical Noise (ECN), supported by statistical analysis and multiscale time–frequency methods based on discrete wavelet transforms, was employed to evaluate passive film protectiveness and stability. The results reveal a significant and non-linear influence of Fe content on the corrosion behavior of Zr–Nb alloys and modulates the frequency distribution of electrochemical noise, indicating a mechanistic role in repassivation dynamics. Increasing Fe content shifts the wavelet energy distribution from low-frequency to high-frequency coefficients, indicating a transition from steady-state passivation to intermittent repassivation. This transition is accompanied by increased average polarization resistance and reduced corrosion current densities, albeit with greater statistical dispersion. The Zr-Nb alloy with 600 ppm Fe exhibited pronounced electrochemical noise dispersion and intermittent localized transients, attributed to passive film rupture followed by rapid repassivation. These results demonstrate that corrosion resistance in zirconium alloys for nuclear applications is governed by both passive film protectiveness and its dynamic stability, emphasizing the relevance of combined ECN and wavelet analysis for advanced materials qualification.

  • Hydrogen spillover modulated by metal loading effects on Pd/C electrocatalysts

    by Elizabeth L.G. Paiva, Roberto Z. Nakazato, Ronaldo S. Nunes, Hebe M. Villullas, Eduardo G. Ciapina


  • Open Access

    Evaluation of corrosion resistance and biocompatibility test of Ti10Mo8Nb alloy for biomedical applications

    by Edwin G. M. Bejarano, Patrícia Capellato, Roberto Z. Nakazato, Kerolene B. da Silva, João P. A. Carobolante, Thierre Capellato, Mirian de L. N. M. Melo, Ana Paula R. Alves, Daniela Sachs

    Among the various materials used in the composition of biomedical implants, titanium alloys (Ti) stand out, mainly the β-phase ternary alloys. The Ti10Mo8Nb alloy developed in an electric arc furnace and rotary forging was analyzed and showed adequate mechanical properties. However, its corrosion resistance has not been deeply investigated in the literature. This research aims to investigate the corrosion resistance and bacterial proliferation of β-phase alloys composed of titanium, molybdenum and niobium (Ti10Mo8Nb).For corrosion analysis, a passive current density of 4.2∙10-5 A/cm² and a dissolution potential of 1.5 V were obtained. Its biocompatibility tests, based on bacterial proliferation was 12.3% lower than that of commercially pure Ti. Combined with the mechanical characteristics of Ti10Mo8Nb, the alloy presented potential and advantageous properties to make it applicable in the field of biomedical application.


  • Open Access

    Influence of a Novel Thermomechanical Processing Route on the Structural, Mechanical, and Corrosion Properties of a Biodegradable Fe-35Mn Alloy

    by Kerolene Barboza da Silva, João Pedro Aquiles Carobolante, Roberto Zenhei Nakazato, Angelo Caporalli Filho, Ana Paula Rosifini Alves

    Recent studies have focused on developing temporary metallic implants made from biodegradable biomaterials, such as iron and its alloys, along with the associated manufacturing methods. These biomaterials allow the implant to gradually degrade after fulfilling its function, which reduces the risks of complications associated with permanent implants. Iron is particularly appealing from a structural standpoint, and adding manganese enhances its potential for use. The Fe-35Mn alloy demonstrates excellent mechanical properties and degradation characteristics, making it an ideal choice within the Fe-Mn system. As a result, new processing techniques can be applied to this alloy to further improve its performance. The objective of this research is to propose a new processing route and evaluate its impact on the properties of the Fe-35Mn alloy. The experimental alloy was produced using an arc melting furnace, followed by homogenization, hot swaging, and solution treatment. Alloy characterization was conducted using various techniques, including X-ray fluorescence (XRF), optical microscopy (OM), X-ray diffraction (XRD), differential scanning calorimetry (DSC), microhardness testing, tensile strength measurements, Young’s modulus determination, and potentiodynamic polarization analysis. The microstructural evolution throughout the applied processing route was analyzed in relation to the alloy’s mechanical performance and corrosion resistance. The typical microstructure of the Fe-35Mn alloy is primarily composed of austenitic grains stabilized at room temperature. Its mechanical properties—yield strength (297 MPa), ultimate tensile strength (533 MPa), and elongation to failure (39%)—are comparable to, or even surpass, those of conventional biomedical materials such as 316 L stainless steel and pure iron. The reduced Young’s modulus (171 GPa), compared to other alloys, further underscores its potential for biomedical applications. Electrochemical testing revealed lower corrosion resistance than that of similar alloys reported in the literature, with a corrosion potential of −0.76 V and a current density of 3.88 µA·cm−2, suggesting an enhanced corrosion rate.


  • Open Access

    Mechanical Properties, Corrosion Behavior, and In Vitro Cell Studies of the New Ti-25Ta-25Nb-5Sn Alloy

    by Kerolene Barboza da Silva, João Pedro Aquiles Carobolante, S. Sudhagara Rajan, Celso Bortolini Júnior, Roberta Maia Sabino, Maurício Rangel Seixas, Roberto Zenhei Nakazato, Ketul C. Popat, Ana Paula Rosifini Alves Claro

    This study aims to characterize a new Ti-25Ta-25Nb-5Sn alloy for biomedical application. Microstructure, phase formation, mechanical and corrosion properties, along with the cell culture study of the Ti-25Ta-25Nb alloy with Sn content 5 mass% are presented in this article. The experimental alloy was processed in an arc melting furnace, cold worked, and heat treated. For characterization, optical microscopy, X-ray diffraction, microhardness, and Young’s modulus measurements were employed. Corrosion behavior was also evaluated using open-circuit potential (OCP) and potentiodynamic polarization. In vitro studies with human ADSCs were performed to investigate cell viability, adhesion, proliferation, and differentiation. Comparison among the mechanical properties observed in other metal alloy systems, including CP Ti, Ti-25Ta-25Nb, and Ti-25Ta-25-Nb-3Sn showed an increase in microhardness and a decrease in the Young’s modulus when compared to CP Ti. The potentiodynamic polarization tests indicated that the corrosion resistance of the Ti-25Ta-25Nb-5Sn alloy was similar to CP Ti and the experiments in vitro demonstrated great interactions between the alloy surface and cells in terms of adhesion, proliferation, and differentiation. Therefore, this alloy presents potential for biomedical applications with properties required for good performance.


  • Open Access

    Influência da agitação no crescimento de nanotubos de TiO2 na superfície de discos de titânio comercialmente puro.

    by Barbara Lois Mathias de Souza, Roberto Zenhei Nakazato, Ana Paula Rosifini Alves Claro, Ana Lúcia Do Amaral Escada

    RESUMO As estratégias atuais no design de biomateriais incluem a alteração das propriedades da superfície do biomaterial para direcionar sistematicamente o comportamento celular. O titânio é o material mais prevalente para uso em implantes devido às suas propriedades mecânicas. Modificações na superfície de titânio podem otimizar a osseointegração de um implante modulando a resposta imunossupressora, acelerando o processo de cicatrização e reduzindo o tempo de tratamento. O crescimento de nanotubos de TiO2 através da anodização pode alterar as propriedades da superfície do titânio comercialmente puro, permitindo uma melhor resposta quando inserido no corpo humano. Objetivo do presente trabalho foi o crescimento de nanotubos de TiO2 na superfície de discos de titânio comercialmente puro e a redução do tempo de anodização, com agitação durante a oxidação anódica, tensão de 30V e eletrólito composto por 90-10% (v/v) de etilenoglicol-H2O e 1% NH4F (m/m). Para determinar a melhor intensidade de agitação foi estabelecido um tempo de 20 minutos. A classificação da intensidade da agitação foi feita pelo método de observação, classificada como fraca, moderada e vigorosa. Para determinar o melhor tempo de oxidação anódica, foi estabelecida intensidade de agitação moderada. O tempo de anodização deve permitir que a estrutura se reorganize e aumente o grau de auto-organização, assim, foram estabelecidos tempos de 20, 30 e 40 minutos. Em seguida, as amostras foram submetidas à calcinação em forno mufla EDG com taxa de aquecimento de 5ºC/minuto, mantida por 1 hora a 450ºC. A morfologia da superfície foi analisada por microscopia eletrônica de varredura (MEV), ângulo de contato e difração de raios X (DRX).