Marcin Gnyba
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Research Interests
Marcin Gnyba has a total of 94 co-authors. Here are the top co-authors by number of shared publications:
- Robert Bogdanowicz
Gdansk University of Technology
23 shared publications - Michał Sobaszek
Gdansk University of Technology
13 shared publications - Małgorzata Szczerska
Department of Metrology and Optoelectronics, Faculty of Electronics, Telecommunications and Informatics Gdansk University of Technology Gdansk Poland
12 shared publications - Jacek Ryl
Faculty of Applied Physics and Mathematics Division of Electrochemistry and Surface Physical Chemistry Gdańsk University of Technology Gdansk Poland
11 shared publications - Mateusz Ficek
Department of Metrology and Optoelectronics, Faculty of Electronics, Telecommunications and Informatics, Gdask University of Technology, Gdask, Poland
8 shared publications - Maciej Stefan Wróbel
Gdańsk University of Technology, Department of Metrology and Optoelectronics, Faculty of Electronics, Telecommunications and Informatics, Gdansk, Poland
6 shared publications
Latest Publications
- 4 August 2018
- Published by Springer Nature in Journal of Sol-Gel Science and Technology
- Vol. 87 (3) , 725-733
Spectroscopic studies of a ring opening process between epoxy- and aminosilanes and imine formation reactions in aqueous solutions
- 4 August 2018
- Published by Springer Nature in Journal of Sol-Gel Science and Technology
- Vol. 87 (3) , 725-733
Spectroscopic studies of a ring opening process between epoxy- and aminosilanes and imine formation reactions in aqueous solutions
- Open Access
- 1 June 2018
- Published by Walter de Gruyter GmbH in Materials Science-Poland
- Vol. 36 (2) , 288-296
Gas Composition Influence on the Properties of Boron-Doped Diamond Films Deposited on the Fused Silica
The main subject of this study are molecular structures and optical properties of boron-doped diamond films with [B]/[C]ppm ratio between 1000 and 10 000, fabricated in two molar ratios of CH4-H2mixture (1 % and 4 %). Boron-doped diamond (BDD) film on the fused silica was presented as a conductive coating for optical and electronic purposes. The scanning electron microscopy images showed homogenous and polycrystalline surface morphology. The Raman spectroscopy confirmed the growth of sp3 diamond phase and sp2carbon phase, both regular and amorphous, on the grain boundaries, as well as the efficiency of boron doping. The sp3/sp2ratio was calculated using the Raman spectra deconvolution method. A high refractive index (in a range of 2.0 to 2.4 at λ= 550 nm) was achieved for BDD films deposited at 700 °C. The values of extinction coefficient were below 1.4 at λ= 550 nm, indicating low absorption of the film
- 1 June 2018
- Published by Walter de Gruyter GmbH in Materials Science-Poland
- Vol. 36 (2) , 288-296
Open AccessGas Composition Influence on the Properties of Boron-Doped Diamond Films Deposited on the Fused Silica
The main subject of this study are molecular structures and optical properties of boron-doped diamond films with [B]/[C]ppm ratio between 1000 and 10 000, fabricated in two molar ratios of CH4-H2mixture (1 % and 4 %). Boron-doped diamond (BDD) film on the fused silica was presented as a conductive coating for optical and electronic purposes. The scanning electron microscopy images showed homogenous and polycrystalline surface morphology. The Raman spectroscopy confirmed the growth of sp3 diamond phase and sp2carbon phase, both regular and amorphous, on the grain boundaries, as well as the efficiency of boron doping. The sp3/sp2ratio was calculated using the Raman spectra deconvolution method. A high refractive index (in a range of 2.0 to 2.4 at λ= 550 nm) was achieved for BDD films deposited at 700 °C. The values of extinction coefficient were below 1.4 at λ= 550 nm, indicating low absorption of the film
- 6 April 2017
- Published by American Chemical Society (ACS) in ACS Applied Materials & Interfaces
- Vol. 9 (15) , 12982-12992
Boron-Enhanced Growth of Micron-Scale Carbon-Based Nanowalls: A Route toward High Rates of Electrochemical Biosensing
In this study, we have demonstrated the fabrication of novel materials called boron-doped carbon nanowalls (B:CNWs), which are characterized by remarkable electrochemical properties such as high standard rate constant (k°), low peak-to-peak separation value (ΔE) for the oxidation and reduction processes of the [Fe(CN)6]3–/4– redox system, and low surface resistivity. The B:CNW samples were deposited by the microwave plasma-assisted chemical vapor deposition (CVD) using a gas mixture of H2/CH4/B2H6 and N2. Growth results in sharp-edged, flat, and long CNWs rich in sp2 as well as sp3 hybridized phases. The achieved high values of k° (1.1 × 10–2 cm s–1) and ΔE (85 mV) are much lower compared to those of the glassy carbon or undoped CNWs. The enhanced electrochemical performance of the B:CNW electrode facilitates the simultaneous detection of DNA purine bases: adenine and guanine. Both separated oxidation peaks for the independent determination of guanine and adenine were observed by means of cyclic voltammetry or differential pulse voltammetry. It is worth noting that the determined sensitivities and the current densities were about 1 order of magnitude higher than those registered by other electrodes.
- 6 April 2017
- Published by American Chemical Society (ACS) in ACS Applied Materials & Interfaces
- Vol. 9 (15) , 12982-12992
Boron-Enhanced Growth of Micron-Scale Carbon-Based Nanowalls: A Route toward High Rates of Electrochemical Biosensing
In this study, we have demonstrated the fabrication of novel materials called boron-doped carbon nanowalls (B:CNWs), which are characterized by remarkable electrochemical properties such as high standard rate constant (k°), low peak-to-peak separation value (ΔE) for the oxidation and reduction processes of the [Fe(CN)6]3–/4– redox system, and low surface resistivity. The B:CNW samples were deposited by the microwave plasma-assisted chemical vapor deposition (CVD) using a gas mixture of H2/CH4/B2H6 and N2. Growth results in sharp-edged, flat, and long CNWs rich in sp2 as well as sp3 hybridized phases. The achieved high values of k° (1.1 × 10–2 cm s–1) and ΔE (85 mV) are much lower compared to those of the glassy carbon or undoped CNWs. The enhanced electrochemical performance of the B:CNW electrode facilitates the simultaneous detection of DNA purine bases: adenine and guanine. Both separated oxidation peaks for the independent determination of guanine and adenine were observed by means of cyclic voltammetry or differential pulse voltammetry. It is worth noting that the determined sensitivities and the current densities were about 1 order of magnitude higher than those registered by other electrodes.
- Open Access
- 1 March 2017
- Published by Walter de Gruyter GmbH in Metrology and Measurement Systems
- Vol. 24 (1) , 153-160
Examination of Sol-Gel Derived Hydroxyapatite Enhanced with Silver Nanoparticles using OCT and Raman Spectroscopy
Hydroxyapatite (HAp) has been attracting widespread interest in medical applications. In a form of coating, it enables to create a durable bond between an implant and surrounding bone tissues. With addition of silver nanoparticles HAp should also provide antibacterial activity. The aim of this research was to evaluate the composition of hydroxyapatite with silver nanoparticles in a non-destructive and non-contact way. For control measurements of HAp molecular composition and solvent evaporation efficiency the Raman spectroscopy has been chosen. In order to evaluate dispersion and concentration of the silver nanoparticles inside the hydroxyapatite matrix, the optical coherence tomography (OCT) has been used. Five samples were developed and examined ‒ a reference sample of pure HAp sol and four samples of HAp colloids with different silver nanoparticle solution volume ratios. The Raman spectra for each solution have been obtained and analyzed. Furthermore, a transverse-sectional visualization of every sample has been created and examined by means of OCT.
- 1 March 2017
- Published by Walter de Gruyter GmbH in Metrology and Measurement Systems
- Vol. 24 (1) , 153-160
Open AccessExamination of Sol-Gel Derived Hydroxyapatite Enhanced with Silver Nanoparticles using OCT and Raman Spectroscopy
Hydroxyapatite (HAp) has been attracting widespread interest in medical applications. In a form of coating, it enables to create a durable bond between an implant and surrounding bone tissues. With addition of silver nanoparticles HAp should also provide antibacterial activity. The aim of this research was to evaluate the composition of hydroxyapatite with silver nanoparticles in a non-destructive and non-contact way. For control measurements of HAp molecular composition and solvent evaporation efficiency the Raman spectroscopy has been chosen. In order to evaluate dispersion and concentration of the silver nanoparticles inside the hydroxyapatite matrix, the optical coherence tomography (OCT) has been used. Five samples were developed and examined ‒ a reference sample of pure HAp sol and four samples of HAp colloids with different silver nanoparticle solution volume ratios. The Raman spectra for each solution have been obtained and analyzed. Furthermore, a transverse-sectional visualization of every sample has been created and examined by means of OCT.
- 1 November 2016
- Published by Elsevier in Applied Surface Science
- Vol. 387, 846-856
Optical and electrical properties of boron doped diamond thin conductive films deposited on fused silica glass substrates
- 1 November 2016
- Published by Elsevier in Applied Surface Science
- Vol. 387, 846-856
Optical and electrical properties of boron doped diamond thin conductive films deposited on fused silica glass substrates
- Open Access
- 1 March 2016
- Published by World Scientific Pub Co Pte Ltd in Journal of Innovative Optical Health Sciences
- Vol. 09 (02)
Blood equivalent phantom vs whole human blood, a comparative study
Preclinical research of biomedical optoelectronic devices is often performed with the use of blood phantoms — a simplified physical model of blood. The aim of this study is the comparison and distinction between blood phantoms as well as whole human blood measurements. We show how the use of such phantoms may influence the incorrect interpretation of measured signal. On the other hand, we highlight how the use of blood phantoms enables to investigate the phenomena that otherwise are almost impossible to be noticed.
- 1 March 2016
- Published by World Scientific Pub Co Pte Ltd in Journal of Innovative Optical Health Sciences
- Vol. 09 (02)
Open AccessBlood equivalent phantom vs whole human blood, a comparative study
Preclinical research of biomedical optoelectronic devices is often performed with the use of blood phantoms — a simplified physical model of blood. The aim of this study is the comparison and distinction between blood phantoms as well as whole human blood measurements. We show how the use of such phantoms may influence the incorrect interpretation of measured signal. On the other hand, we highlight how the use of blood phantoms enables to investigate the phenomena that otherwise are almost impossible to be noticed.
- 25 December 2015
- Published by Korean Journal of Optics and Photonics in Journal of the Optical Society of Korea
- Vol. 19 (6) , 705-710
Opto-Electrochemical Sensing Device Based on Long-Period Grating Coated with Boron-Doped Diamond Thin Film
- 25 December 2015
- Published by Korean Journal of Optics and Photonics in Journal of the Optical Society of Korea
- Vol. 19 (6) , 705-710
Opto-Electrochemical Sensing Device Based on Long-Period Grating Coated with Boron-Doped Diamond Thin Film
- 11 September 2015
- Published by SPIE-Intl Soc Optical Eng
- Vol. 9662, 96621H-96621H-7
Absorption spectroscopy setup for determination of whole human blood and blood–derived materials spectral characteristics
- 11 September 2015
- Published by SPIE-Intl Soc Optical Eng
- Vol. 9662, 96621H-96621H-7
Absorption spectroscopy setup for determination of whole human blood and blood–derived materials spectral characteristics
- 17 July 2015
- Published by SPIE-Intl Soc Optical Eng
- Vol. 9540, 95400Q
Optical properties of the chemotherapy drugs used in the central nervous system lymphoma therapy: monitoring drug delivery
Our aim is to optically monitor the delivery of the chemotherapy drugs for brain tumours, particularly used in the central nervous system (CNS) lymphoma therapy. In vivo monitoring would help to optimize the treatment and avoiding unnecessary medications. Moreover, it would be beneficial to be able to measure which of the multi-regimen drugs actually do penetrate and how well into the brain tissue. There exist several potential optical measurement techniques to be utilised for the purpose. The most desired method would allow the detection of the drugs without using optical biomarkers as a contrast agent. In this case, for non-invasive sensing of the drug in the brain cortex, the drug should have a reasonably strong optical absorption band somewhere in the range between 600 nm and 1700 nm, and not directly coincident with the strong bands of haemoglobin or water. Alternatively, mid-infrared (MIR) range has the potential for invasive drug monitoring techniques. In this paper, we report the optical properties of several chemotherapy drugs used in CNS lymphoma therapy, such as rituximabi, cyclophosphamide and etoposide. We measured their transmittance and reflectance spectra in near-infrared (NIR) range, particularly 900 nm − 2500 nm, to be considered when choosing the in vivo monitoring method to be developed. The absorption and scattering coefficients were retrieved from the measurements and applying Beer’s law. For the measurement of the sum of total transmission and reflection in NIR range we used integrating sphere with spektralo to enable calculation of the scattering coefficient.
- 17 July 2015
- Published by SPIE-Intl Soc Optical Eng
- Vol. 9540, 95400Q
Optical properties of the chemotherapy drugs used in the central nervous system lymphoma therapy: monitoring drug delivery
Our aim is to optically monitor the delivery of the chemotherapy drugs for brain tumours, particularly used in the central nervous system (CNS) lymphoma therapy. In vivo monitoring would help to optimize the treatment and avoiding unnecessary medications. Moreover, it would be beneficial to be able to measure which of the multi-regimen drugs actually do penetrate and how well into the brain tissue. There exist several potential optical measurement techniques to be utilised for the purpose. The most desired method would allow the detection of the drugs without using optical biomarkers as a contrast agent. In this case, for non-invasive sensing of the drug in the brain cortex, the drug should have a reasonably strong optical absorption band somewhere in the range between 600 nm and 1700 nm, and not directly coincident with the strong bands of haemoglobin or water. Alternatively, mid-infrared (MIR) range has the potential for invasive drug monitoring techniques. In this paper, we report the optical properties of several chemotherapy drugs used in CNS lymphoma therapy, such as rituximabi, cyclophosphamide and etoposide. We measured their transmittance and reflectance spectra in near-infrared (NIR) range, particularly 900 nm − 2500 nm, to be considered when choosing the in vivo monitoring method to be developed. The absorption and scattering coefficients were retrieved from the measurements and applying Beer’s law. For the measurement of the sum of total transmission and reflection in NIR range we used integrating sphere with spektralo to enable calculation of the scattering coefficient.