KDKrishnendu Dandapat

Krishnendu Dandapat

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Krishnendu Dandapat has a total of 20 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Quantitative assessment of collagen architecture from routine histopathological images shows concordance with Second Harmonic Generation microscopy

    by Vedant Ingawale, Krishnendu Dandapat, Jyothsna Konkada Manattayil, Shashank Gupta, L. S. Shashidhara, Chaitanyanand Koppiker, Nameeta Shah, Varun Raghunathan, Madhura Kulkarni

    Collagen organization within the tumour microenvironment plays a critical role in tumour progression and has emerged as an important structural biomarker in cancer. Second Harmonic Generation (SHG) microscopy enables label-free visualization and quantitative assessment of fibrillar collagen architecture; however, its high cost, specialized instrumentation, and limited field-of-view restrict routine clinical application. In this study, we evaluated whether collagen features quantified from digitally scanned Masson–Goldner’s Trichrome-stained histopathological sections can approximate measurements obtained from SHG microscopy. Formalin-fixed paraffin-embedded breast tumour tissues, including benign and invasive ductal carcinoma (IDC) samples with varying collagen content, were analysed using SHG microscopy and whole-slide brightfield imaging. Matched regions of interest were analysed using two independent digital image analysis approaches: a conventional ImageJ-based workflow (TWOMBLI) and a machine learning–based computational pipeline. Collagen structural parameters including collagen deposition area, fibre number, and alignment metrics were quantified and compared across imaging modalities using correlation analysis. SHG signals were consistently detected from Trichrome-stained sections, confirming compatibility of SHG imaging. Quantitative comparison demonstrated significant concordance between SHG-derived collagen metrics and those obtained from digital image analysis pipelines, particularly for collagen area and fibre alignment. These findings demonstrate a proof-of-concept, that computational analysis of routine histopathological images can capture key spatial features of collagen organization comparable to SHG microscopy. Digital pathology–based collagen quantification therefore represents a potentially scalable and clinically accessible approach for assessing extracellular matrix architecture in tumour tissues.

  • A Long-Period Waveguide Grating Sensor for Accurate Simultaneous Detection of Dual Analytes

    by Krishnendu Dandapat, Nabarun Saha, Ranjeet Dwivedi, Saurabh Mani Tripathi, Arun Kumar

    To the best of our knowledge, we are the first to report the existence of two dispersion turning points (DTP) in an optimized planar waveguide long-period grating (LPG) sensor for the lowest order cladding mode. Using numerical simulation, we investigate the potential of the sensor structure for bulk refractive index (RI) and surface sensing, with the goal of predicting its possible application as an integrated photonic biosensor. The proposed sensor exhibits an exceptionally high RI sensitivity ~7500 nm/refractive index unit (RIU) (~10000 nm/RIU) near lower (higher) DTP. The surface sensitivity, which is incredibly high in this form of structure, is found to be 6.5 nm/nm (7 nm/nm) near lower (higher) DTP for the RI relevant for biosensing. Utilizing the sensing characteristics of both the DTP, we propose a dual-slot biosensor by cascading two LPGs having different grating periods. The proposed biosensor shows two independent dual-resonance phenomena and is, therefore, capable of simultaneous detection of dual analytes. Utilizing the proposed dual-slot biosensor, we present simulation results for specific detection of Hepatitis B antigen and DNA hybridization simultaneously. The proposed biosensor will reduce the sensor cost as well as detection time since a single source and detector are required to sense two different analytes at once.


  • Highly sensitive long-period fiber-grating-based biosensor inherently immune to temperature and strain

    by Krishnendu Dandapat, Saurabh Mani Tripathi

    For two simultaneously varying external perturbation parameters, namely, temperature and strain, we propose and theoretically demonstrate a novel, to the best of our knowledge, scheme of developing inherently insensitive biosensors based on long-period fiber gratings (LPFGs). The insensitivities have been achieved by inherently nullifying (i) temperature-induced phases of the core and cladding modes by judiciously adjusting the core dopants and their concentrations and (ii) strain-induced phase changes generated inside one LPFG with that inside the other LPFG by optimizing the grating parameters (grating period, strength, and length). The resulting biosensor has ultrahigh overall bulk refractive index sensitivity of ∼ 3 µ m / R I U for biosamples (RI varying in the range of 1.33 to 1.34 RIU) and an affinity sensitivity of ∼ 1.4 n m / n m for biomolecules ( R I ∼ 1.45 R I U ). Our study should find application in developing ultrasensitive, high-precision bio/chemical sensors that are inherently immune to environmental temperature and strain variations.


  • Ultrahigh sensitive long-period fiber grating-based sensor for detection of adulterators in biofuel

    by Krishnendu Dandapat, Indrajeet Kumar, Saurabh Mani Tripathi

    An ultra-sensitive sensor based on dual resonance long-period fiber gratings has been fabricated for the detection of methanol and water content in ethanol. The developed sensor is compact in size and light weight and employs a highly accurate spectral interrogation technique for adulterant detection, increasing its applicability compared to conventional surface plasmon resonance based sensors, which are generally expensive, as they require metal film deposition. We demonstrate that the sensor is capable of achieving sensitivity of 802.66 pm/V% methanol and 749.06 pm/V% water in the ethanol solution. The estimated detection limit using the experimental data and spectral resolution of the interrogator is found to be ∼ 1.3 × 10 − 3 V % in the 1300–1700 nm wavelength range. We also present the sensor’s theoretical study, and good agreement is found between theoretical and experimental results.


  • Open Access

    Single-Multi-Single Fibre Optic Structure Based Water Depth Sensor

    by Garima Bawa, Krishnendu Dandapat, Gyanendra Kumar, Indrajeet Kumar, Saurabh Mani Tripathi

    We propose and demonstrate a technique easy to fabricate and measure water depth based on selective mode excitation using single-multi-single (SMS) mode structure. The high extinction ratio has been achieved by equally exciting preselected modes of the multi-mode fibre (MMF) by optimizing the core offset at both the input/output splices of the SMS structure, and a wavelength shifting has been achieved by varying the ratio of major to minor axis of the MMF loop. A theoretical analysis of the observed behaviour is also presented showing an excellent agreement between the theoretical and experimental results.

  • Compact and cost-effective temperature-insensitive bio-sensor based on long-period fiber gratings for accurate detection of E coli bacteria in water

    by Krishnendu Dandapat, Saurabh Mani Tripathi, Yasser Chinifooroshan, Wojtek J. Bock, Predrag Mikulic

    We propose and demonstrate a novel temperature-insensitive bio-sensor for accurate and quantitative detection of Escherichia coli (E. coli) bacteria in water. Surface sensitivity is maximized by operating the long-period fiber grating (LPFG) closest to its turnaround wavelength, and the temperature insensitivity is achieved by selectively exciting a pair of cladding modes with opposite dispersion characteristics. Our sensor shows a nominal temperature sensitivity of ∼1.25 pm/°C, which can be further reduced by properly adjusting the LPFG lengths, while maintaining a high refractive index sensitivity of 1929 nm/RIU. The overall length of the sensor is ∼3.6 cm, making it ideally suitable for bio-sensing applications. As an example, we also show the sensor’s capability for reliable, quantitative detection of E. coli bacteria in water over a temperature fluctuation of room temperature to 40°C.