Maria Reyes Elizalde
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Maria Reyes Elizalde has a total of 192 co-authors. Here are the top co-authors by number of shared publications:
- José Manuel Martinez-Esnaola
Ceit-Basque Research and Technology Alliance (BRTA), Manuel Lardizabal 15, 20018 Donostia-San Sebastián, Spain
23 shared publications - José Manuel Sánchez
Universidad de Cádiz
12 shared publications - Patrick J. McNally
School of Electronic Engineering, Dublin City University, Glasnevin, Dublin 9, Ireland
12 shared publications - Brian K. Tanner
Durham University (Durham, United Kingdom)
11 shared publications D. Allen
School of Electronic Engineering, Dublin City University, Dublin 9, Ireland
10 shared publicationsD. Pantuso
Intel Corp, Design Technol Solut, Hillsboro, OR 97124 USA
10 shared publications
Latest Publications
- 18 February 2023
- Published by Springer Nature
- p. 157-189
Mechanical Robustness of Patterned Structures and Failure Mechanisms
- 18 February 2023
- Published by Springer Nature
- p. 157-189
Mechanical Robustness of Patterned Structures and Failure Mechanisms
- Open Access
- 7 January 2022
- Published by Elsevier in Acta Biomaterialia
- Vol. 141, 264-279
Changes in mechanical properties of adipose tissue after bariatric surgery driven by extracellular matrix remodelling and neovascularization are associated with metabolic improvements
- 7 January 2022
- Published by Elsevier in Acta Biomaterialia
- Vol. 141, 264-279
Open AccessChanges in mechanical properties of adipose tissue after bariatric surgery driven by extracellular matrix remodelling and neovascularization are associated with metabolic improvements
- Open Access
Anisotropic Cryostructured Collagen Scaffolds for Efficient Delivery of RhBMP–2 and Enhanced Bone Regeneration
In the treatment of bone non-unions, an alternative to bone autografts is the use of bone morphogenetic proteins (BMPs), e.g., BMP–2, BMP–7, with powerful osteoinductive and osteogenic properties. In clinical settings, these osteogenic factors are applied using absorbable collagen sponges for local controlled delivery. Major side effects of this strategy are derived from the supraphysiological doses of BMPs needed, which may induce ectopic bone formation, chronic inflammation, and excessive bone resorption. In order to increase the efficiency of the delivered BMPs, we designed cryostructured collagen scaffolds functionalized with hydroxyapatite, mimicking the structure of cortical bone (aligned porosity, anisotropic) or trabecular bone (random distributed porosity, isotropic). We hypothesize that an anisotropic structure would enhance the osteoconductive properties of the scaffolds by increasing the regenerative performance of the provided rhBMP–2. In vitro, both scaffolds presented similar mechanical properties, rhBMP–2 retention and delivery capacity, as well as scaffold degradation time. In vivo, anisotropic scaffolds demonstrated better bone regeneration capabilities in a rat femoral critical-size defect model by increasing the defect bridging. In conclusion, anisotropic cryostructured collagen scaffolds improve bone regeneration by increasing the efficiency of rhBMP–2 mediated bone healing.
Open AccessAnisotropic Cryostructured Collagen Scaffolds for Efficient Delivery of RhBMP–2 and Enhanced Bone Regeneration
In the treatment of bone non-unions, an alternative to bone autografts is the use of bone morphogenetic proteins (BMPs), e.g., BMP–2, BMP–7, with powerful osteoinductive and osteogenic properties. In clinical settings, these osteogenic factors are applied using absorbable collagen sponges for local controlled delivery. Major side effects of this strategy are derived from the supraphysiological doses of BMPs needed, which may induce ectopic bone formation, chronic inflammation, and excessive bone resorption. In order to increase the efficiency of the delivered BMPs, we designed cryostructured collagen scaffolds functionalized with hydroxyapatite, mimicking the structure of cortical bone (aligned porosity, anisotropic) or trabecular bone (random distributed porosity, isotropic). We hypothesize that an anisotropic structure would enhance the osteoconductive properties of the scaffolds by increasing the regenerative performance of the provided rhBMP–2. In vitro, both scaffolds presented similar mechanical properties, rhBMP–2 retention and delivery capacity, as well as scaffold degradation time. In vivo, anisotropic scaffolds demonstrated better bone regeneration capabilities in a rat femoral critical-size defect model by increasing the defect bridging. In conclusion, anisotropic cryostructured collagen scaffolds improve bone regeneration by increasing the efficiency of rhBMP–2 mediated bone healing.
- 20 February 2019
- Published by Wiley in Journal of Tissue Engineering and Regenerative Medicine
- Vol. 13 (5) , 742-752
Periosteum‐derived mesenchymal progenitor cells in engineered implants promote fracture healing in a critical‐size defect rat model
An attractive alternative to bone autografts is the use of autologous mesenchymal progenitor cells (MSCs) in combination with biomaterials. We compared the therapeutic potential of different sources of mesenchymal stem cells in combination with biomaterials in a bone nonunion model. A critical‐size defect was created in Sprague‐Dawley rats. Animals were divided into six groups, depending on the treatment to be applied: bone defect was left empty (CTL); treated with live bone allograft (LBA); hrBMP‐2 in collagen scaffold (CSBMP2); acellular polycaprolactone scaffold (PCL group); PCL scaffold containing periosteum‐derived MSCs (PCLPMSCs) and PCL containing bone marrow‐derived MSCs (PCLBMSCs). To facilitate cell tracking, both MSCs and bone graft were isolated from GFP‐transgenic rats. CTL group did not show any signs of healing during the radiological follow‐up (n=6). In the LBA group, all the animals showed bone bridging (n=6) while in the CSBMP2 group, 4 out of 6 animals demonstrated healing. In PCL and PCLPMSCs groups, a reduced number of animals showed radiological healing, while no healing was detected in the PCLBMSCs group. Using micro‐computed tomography, the bone volume filling the defect was quantified, showing significant new bone formation in the LBA, CSBMP2 and PCLPMSCs groups when compared with the CTL group. At 10 weeks, GFP positive cells were detected only in the LBA group and restricted to the outer cortical bone in close contact with the periosteum. Tracking of cellular implants demonstrated significant survival of the PMSCs when compared with BMSCs. In conclusion, PMSCs improve bone regeneration being suitable for mimetic autograft design.
- 20 February 2019
- Published by Wiley in Journal of Tissue Engineering and Regenerative Medicine
- Vol. 13 (5) , 742-752
Periosteum‐derived mesenchymal progenitor cells in engineered implants promote fracture healing in a critical‐size defect rat model
An attractive alternative to bone autografts is the use of autologous mesenchymal progenitor cells (MSCs) in combination with biomaterials. We compared the therapeutic potential of different sources of mesenchymal stem cells in combination with biomaterials in a bone nonunion model. A critical‐size defect was created in Sprague‐Dawley rats. Animals were divided into six groups, depending on the treatment to be applied: bone defect was left empty (CTL); treated with live bone allograft (LBA); hrBMP‐2 in collagen scaffold (CSBMP2); acellular polycaprolactone scaffold (PCL group); PCL scaffold containing periosteum‐derived MSCs (PCLPMSCs) and PCL containing bone marrow‐derived MSCs (PCLBMSCs). To facilitate cell tracking, both MSCs and bone graft were isolated from GFP‐transgenic rats. CTL group did not show any signs of healing during the radiological follow‐up (n=6). In the LBA group, all the animals showed bone bridging (n=6) while in the CSBMP2 group, 4 out of 6 animals demonstrated healing. In PCL and PCLPMSCs groups, a reduced number of animals showed radiological healing, while no healing was detected in the PCLBMSCs group. Using micro‐computed tomography, the bone volume filling the defect was quantified, showing significant new bone formation in the LBA, CSBMP2 and PCLPMSCs groups when compared with the CTL group. At 10 weeks, GFP positive cells were detected only in the LBA group and restricted to the outer cortical bone in close contact with the periosteum. Tracking of cellular implants demonstrated significant survival of the PMSCs when compared with BMSCs. In conclusion, PMSCs improve bone regeneration being suitable for mimetic autograft design.
- 29 November 2018
- Published by Springer Nature in Journal of Materials Science
- Vol. 54 (6) , 5044-5060
Austempering in low-C steels: microstructure development and nanohardness characterization
- 29 November 2018
- Published by Springer Nature in Journal of Materials Science
- Vol. 54 (6) , 5044-5060
Austempering in low-C steels: microstructure development and nanohardness characterization
- Open Access
Quantitative Imaging of the Stress/Strain Fields and Generation of Macroscopic Cracks from Indents in Silicon
The crack geometry and associated strain field around Berkovich and Vickers indents on silicon have been studied by X-ray diffraction imaging and micro-Raman spectroscopy scanning. The techniques are complementary; the Raman data come from within a few micrometres of the indentation, whereas the X-ray image probes the strain field at a distance of typically tens of micrometres. For example, Raman data provide an explanation for the central contrast feature in the X-ray images of an indent. Strain relaxation from breakout and high temperature annealing are examined and it is demonstrated that millimetre length cracks, similar to those produced by mechanical damage from misaligned handling tools, can be generated in a controlled fashion by indentation within 75 micrometres of the bevel edge of 200 mm diameter wafers.
Open AccessQuantitative Imaging of the Stress/Strain Fields and Generation of Macroscopic Cracks from Indents in Silicon
The crack geometry and associated strain field around Berkovich and Vickers indents on silicon have been studied by X-ray diffraction imaging and micro-Raman spectroscopy scanning. The techniques are complementary; the Raman data come from within a few micrometres of the indentation, whereas the X-ray image probes the strain field at a distance of typically tens of micrometres. For example, Raman data provide an explanation for the central contrast feature in the X-ray images of an indent. Strain relaxation from breakout and high temperature annealing are examined and it is demonstrated that millimetre length cracks, similar to those produced by mechanical damage from misaligned handling tools, can be generated in a controlled fashion by indentation within 75 micrometres of the bevel edge of 200 mm diameter wafers.
- 1 October 2017
- Published by Elsevier in Revista Española de Cardiología (English Edition)
- Vol. 70 (10) , 832-840
Papel del colágeno miocárdico en la estenosis aórtica grave con fracción de eyección conservada y síntomas de insuficiencia cardiaca
- 1 October 2017
- Published by Elsevier in Revista Española de Cardiología (English Edition)
- Vol. 70 (10) , 832-840
Papel del colágeno miocárdico en la estenosis aórtica grave con fracción de eyección conservada y síntomas de insuficiencia cardiaca
- 1 February 2016
- Published by International Union of Crystallography (IUCr) in Journal of Applied Crystallography
- Vol. 49 (1) , 250-259
X-ray asterism and the structure of cracks from indentations in silicon
The asterism observed in white radiation X-ray diffraction images (topographs) of extended cracks in silicon is investigated and found to be associated with material that is close to breakout and surrounded by extensive cracking. It is a measure of the mechanical damage occurring when the fracture planes do not follow the low-index cleavage planes associated with the crystal structure. It is not related to a propensity for some cracked wafers to shatter during subsequent high-temperature processing. There is no correlation between crack morphology and alignment of an indenter with respect to the orientation of a silicon wafer, the cracks being generated from the apices of the indenter and having threefold symmetry for Berkovich indents and fourfold symmetry for Vickers indents. X-ray diffraction imaging (XRDI) of indents does not reveal this underlying symmetry and the images exhibit a very substantial degree of variation in their extent. This arises because the XRDI contrast is sensitive to the long-range strain field around the indent and breakout reduces the extent of this long-range strain field. Breakout is also detected in the loss of symmetry in the short-range strain field imaged by scanning micro-Raman spectroscopy. Weak fourfold symmetric features at the extremes of the images, and lying along 〈110〉 directions, are discussed in the context of slip generated below the room-temperature indents. Scanning electron microscopy imaging of the region around an indent during focused ion beam milling has permitted the three-dimensional reconstruction of the crack morphology. The surface-breaking Palmqvist cracks are found to be directly connected to the median subsurface cracks, and the presence of extensive lateral cracks is a prerequisite for material breakout at indenter loads above 200 mN. The overall crack shape agrees with that predicted from simulation.
- 1 February 2016
- Published by International Union of Crystallography (IUCr) in Journal of Applied Crystallography
- Vol. 49 (1) , 250-259
X-ray asterism and the structure of cracks from indentations in silicon
The asterism observed in white radiation X-ray diffraction images (topographs) of extended cracks in silicon is investigated and found to be associated with material that is close to breakout and surrounded by extensive cracking. It is a measure of the mechanical damage occurring when the fracture planes do not follow the low-index cleavage planes associated with the crystal structure. It is not related to a propensity for some cracked wafers to shatter during subsequent high-temperature processing. There is no correlation between crack morphology and alignment of an indenter with respect to the orientation of a silicon wafer, the cracks being generated from the apices of the indenter and having threefold symmetry for Berkovich indents and fourfold symmetry for Vickers indents. X-ray diffraction imaging (XRDI) of indents does not reveal this underlying symmetry and the images exhibit a very substantial degree of variation in their extent. This arises because the XRDI contrast is sensitive to the long-range strain field around the indent and breakout reduces the extent of this long-range strain field. Breakout is also detected in the loss of symmetry in the short-range strain field imaged by scanning micro-Raman spectroscopy. Weak fourfold symmetric features at the extremes of the images, and lying along 〈110〉 directions, are discussed in the context of slip generated below the room-temperature indents. Scanning electron microscopy imaging of the region around an indent during focused ion beam milling has permitted the three-dimensional reconstruction of the crack morphology. The surface-breaking Palmqvist cracks are found to be directly connected to the median subsurface cracks, and the presence of extensive lateral cracks is a prerequisite for material breakout at indenter loads above 200 mN. The overall crack shape agrees with that predicted from simulation.
- Open Access
- 1 September 2015
- Published by Springer Nature in International Journal of Fracture
- Vol. 195 (1-2) , 79-85
The geometry of catastrophic fracture during high temperature processing of silicon
- 1 September 2015
- Published by Springer Nature in International Journal of Fracture
- Vol. 195 (1-2) , 79-85
Open AccessThe geometry of catastrophic fracture during high temperature processing of silicon