Edisson Escobar Rosero
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Edisson Escobar Rosero has a total of 13 co-authors. Here are the top co-authors by number of shared publications:
- Francisco Eraso-Checa
Universidad CESMAG, Pasto 520002, Colombia
5 shared publications - Camilo Lagos
Institución Universitaria CESMAG, San Juan de Pasto, Colombia
1 shared publication David Gamez Patino
Departamento de Electrónica, Facultad de Ingeniería, Universidad de Nariño, Pasto, Colombia
1 shared publicationDavid Gamez Patiño
Departamento de Electrónica, Facultad de Ingeniería, Universidad de Nariño, San Juan Pasto, 520001, Colombia
1 shared publicationEdison Geovanny Guamá Erira
Departamento de Electrónica, Facultad de Ingeniería, Universidad de Nariño, San Juan Pasto, 520001, Colombia
1 shared publicationEdison Guaina Erira
Departamento de Electrónica, Facultad de Ingeniería, Universidad de Nariño, Pasto, Colombia
1 shared publication
Latest Publications
- Open Access
- 1 April 2019
- Published by Universidad de Tarapacá in Ingeniare. Revista chilena de ingeniería
- Vol. 27 (2) , 188-196
Modelo para la estimación de potencia eléctrica en módulos fotovoltaicos de tecnología basada en silicio
Los módulos fotovoltaicos presentan una capacidad de generación de potencia dependiente de las condiciones climatológicas de su sitio de ubicación. Este trabajo desarrolla y evalúa un modelo que permite determinar la potencia que generaran los módulos solares basados en tecnologías de silicio, monocristalino, policristalino y amorfo de película delgada, si se conocen las condiciones de temperatura e irradiancia de la zona en la cual planean ser ubicados. El modelo se realizó analizando la respuesta en potencia de diferentes módulos solares ante el comportamiento climatológico de una zona durante un año (datos recolectados por un sistema meteorológico). Los parámetros del modelo se calcularon utilizando el algoritmo cuasi Newton con actualización BFGS. La respuesta en potencia presentada por el modelo se comparó con la respuesta generada por un sistema fotovoltaico real que incluye los tres tipos de tecnología alimentando una carga D.C. evidenciando que la respuesta real corresponde a la estimación entregada por el modelo.
- 1 April 2019
- Published by Universidad de Tarapacá in Ingeniare. Revista chilena de ingeniería
- Vol. 27 (2) , 188-196
Open AccessModelo para la estimación de potencia eléctrica en módulos fotovoltaicos de tecnología basada en silicio
Los módulos fotovoltaicos presentan una capacidad de generación de potencia dependiente de las condiciones climatológicas de su sitio de ubicación. Este trabajo desarrolla y evalúa un modelo que permite determinar la potencia que generaran los módulos solares basados en tecnologías de silicio, monocristalino, policristalino y amorfo de película delgada, si se conocen las condiciones de temperatura e irradiancia de la zona en la cual planean ser ubicados. El modelo se realizó analizando la respuesta en potencia de diferentes módulos solares ante el comportamiento climatológico de una zona durante un año (datos recolectados por un sistema meteorológico). Los parámetros del modelo se calcularon utilizando el algoritmo cuasi Newton con actualización BFGS. La respuesta en potencia presentada por el modelo se comparó con la respuesta generada por un sistema fotovoltaico real que incluye los tres tipos de tecnología alimentando una carga D.C. evidenciando que la respuesta real corresponde a la estimación entregada por el modelo.
- Open Access
- 1 January 2018
- Published by Universidad Distrital Francisco Jose de Caldas in Revista Científica
- Vol. 1 (31) , 19-31
Methodology for the determination of wind characteristics and assessment of wind energy potential in Tuquerres - Narino
The world is living a steady increase in the electric power demand, an alternative power generation different to conventional is the renewable energy. With the appearance of the Law 1715, Colombia has an incentives policy for the integration of new projects in renewable energies. Because of that, is important to develop studies with real data in the field of the potential of renewable energy resources which can be implemented. This article presents the analysis of the wind generation potential of Tuquerres Savanna, located in the department of Narino. The potential was obtained from the measurement of the wind speed, during the period between the months of June and December of the year 2015. The data were analyzed statistically according to a measure of central tendency, frequency distribution and Weibull distribution for the normalization of scattered data; finally, the power density was calculated according to a horizontal axis wind turbine and the electrical generation potential of the area was simulated. The average wind speeds are 4,4 m/s and the power density founded is 3,47 W/m2.
- 1 January 2018
- Published by Universidad Distrital Francisco Jose de Caldas in Revista Científica
- Vol. 1 (31) , 19-31
Open AccessMethodology for the determination of wind characteristics and assessment of wind energy potential in Tuquerres - Narino
The world is living a steady increase in the electric power demand, an alternative power generation different to conventional is the renewable energy. With the appearance of the Law 1715, Colombia has an incentives policy for the integration of new projects in renewable energies. Because of that, is important to develop studies with real data in the field of the potential of renewable energy resources which can be implemented. This article presents the analysis of the wind generation potential of Tuquerres Savanna, located in the department of Narino. The potential was obtained from the measurement of the wind speed, during the period between the months of June and December of the year 2015. The data were analyzed statistically according to a measure of central tendency, frequency distribution and Weibull distribution for the normalization of scattered data; finally, the power density was calculated according to a horizontal axis wind turbine and the electrical generation potential of the area was simulated. The average wind speeds are 4,4 m/s and the power density founded is 3,47 W/m2.
- 1 October 2015
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 757-761
Comparison between the energy generated from three types of c-Si photovoltaic modules and the temperature and irradiance of the city of Pasto, Colombia
Under standard test conditions (STC) the photovoltaic cells delivers a certain quantity of energy related with the efficiency of the manufacturing technologies, however the operating conditions from a specific place are quite different from STC. This work analyses the amount of energy generated from monocrystalline, polycrystalline and amorphous silicon solar panels under temperature and irradiance conditions of the city of Pasto. This data was collected in the year 2014 using a power acquisition system, DAVIS-vantage Pro2 and Esmera meteorological station, MySQL database and MATLAB. As result this paper presents the statistical analyses and a model that predicts the possible behaviour of the energy generated by each one of the technologies concerning the temperature and irradiance conditions of the city.
- 1 October 2015
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 757-761
Comparison between the energy generated from three types of c-Si photovoltaic modules and the temperature and irradiance of the city of Pasto, Colombia
Under standard test conditions (STC) the photovoltaic cells delivers a certain quantity of energy related with the efficiency of the manufacturing technologies, however the operating conditions from a specific place are quite different from STC. This work analyses the amount of energy generated from monocrystalline, polycrystalline and amorphous silicon solar panels under temperature and irradiance conditions of the city of Pasto. This data was collected in the year 2014 using a power acquisition system, DAVIS-vantage Pro2 and Esmera meteorological station, MySQL database and MATLAB. As result this paper presents the statistical analyses and a model that predicts the possible behaviour of the energy generated by each one of the technologies concerning the temperature and irradiance conditions of the city.
- 1 October 2015
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 833-838
SOGI-FLL for synchronization and fault detection in an inverter connected to the grid
This paper presents a theoretical analysis and simulation for the design and implementation of a Second Order Generalized Integrator - Frequency Locked Loop (SOGI-FLL) aimed at synchronization and fault detection when connecting an inverter to the utility grid. Such an inverter is implemented in a Highly-Efficient-and-Reliable- Inverter-Concept (HERIC) topology. The two main aims of this work are: First, the frequency and phase synchronization of the HERIC power inverter with the grid through the SOGI-FLL. Second, the detection of abnormal conditions that may occur in the coupling point system by analyzing changes in frequency, phase shifts and amplitude variations. This is done by complying with the IEEE 1547 standard for disconnecting generation systems to the grid in case of failure. Finally, from the experimental results, it can be concluded that the SOGI-FLL system is an appropriate alternative for controlling the injection of energy process into the grid, as well as for detecting possible grid faults.
- 1 October 2015
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 833-838
SOGI-FLL for synchronization and fault detection in an inverter connected to the grid
This paper presents a theoretical analysis and simulation for the design and implementation of a Second Order Generalized Integrator - Frequency Locked Loop (SOGI-FLL) aimed at synchronization and fault detection when connecting an inverter to the utility grid. Such an inverter is implemented in a Highly-Efficient-and-Reliable- Inverter-Concept (HERIC) topology. The two main aims of this work are: First, the frequency and phase synchronization of the HERIC power inverter with the grid through the SOGI-FLL. Second, the detection of abnormal conditions that may occur in the coupling point system by analyzing changes in frequency, phase shifts and amplitude variations. This is done by complying with the IEEE 1547 standard for disconnecting generation systems to the grid in case of failure. Finally, from the experimental results, it can be concluded that the SOGI-FLL system is an appropriate alternative for controlling the injection of energy process into the grid, as well as for detecting possible grid faults.
- 1 June 2015
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-6
Implementation a HERIC inverter prototype connected to the grid controlled by SOGI-FLL
This paper presents a feasible implementation of a single phase inverter prototype via a Highly Efficient and Reliable Inverter Concept (HERIC) topology, which is connected to the grid through a phase and frequency synchronization system by means of a Second Order Generalized Integrator - Frequency Locked Loop (SOGI-FLL). The chosen topology for the inverter design-unlike a full H-bridge (FB) inverter-incorporates two transistors in the output aimed at preventing reactive power transfer between the output filter and input capacitor when zero-crossing. Furthermore, proposed inverter implementation presents low leakage currents, and increases HERIC system efficiency. Moreover, the SOGI-FLL chosen for connecting the HERIC inverter to the grid provides - even under harmonic distortion - a fast and accurate frequency tracking. The prototype implementation can be divided into two parts: First, the power inverter HERIC is implemented, which holds four transistors MOSFET IRF730 (400V-10A) in a FB topology, as well as two IGBT transistors GP10NC60KD (600V-10A). In addition, in order to protect all the devices and ensure a well transistor conmmuation, four diodes type SF54 (200V-5A) are located between emisor and collector from all transistors. Second, the synchronization system is implemented on an Arduino Due digital platform.
- 1 June 2015
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-6
Implementation a HERIC inverter prototype connected to the grid controlled by SOGI-FLL
This paper presents a feasible implementation of a single phase inverter prototype via a Highly Efficient and Reliable Inverter Concept (HERIC) topology, which is connected to the grid through a phase and frequency synchronization system by means of a Second Order Generalized Integrator - Frequency Locked Loop (SOGI-FLL). The chosen topology for the inverter design-unlike a full H-bridge (FB) inverter-incorporates two transistors in the output aimed at preventing reactive power transfer between the output filter and input capacitor when zero-crossing. Furthermore, proposed inverter implementation presents low leakage currents, and increases HERIC system efficiency. Moreover, the SOGI-FLL chosen for connecting the HERIC inverter to the grid provides - even under harmonic distortion - a fast and accurate frequency tracking. The prototype implementation can be divided into two parts: First, the power inverter HERIC is implemented, which holds four transistors MOSFET IRF730 (400V-10A) in a FB topology, as well as two IGBT transistors GP10NC60KD (600V-10A). In addition, in order to protect all the devices and ensure a well transistor conmmuation, four diodes type SF54 (200V-5A) are located between emisor and collector from all transistors. Second, the synchronization system is implemented on an Arduino Due digital platform.
- 1 June 2015
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-6
Study of the relationship between irradiance and power generated by PV panels based on different silicon technologies in the city of Pasto
This work presents the relationship between the irradiance, in the city of Pasto, and the power generated by three types of PV panels: monocrystalline, polycrystalline and amorphous silicon thin film. The irradiance data was collected in the year 2014, using the weather station DAVIS Advantage PRO 2.0. The power generated by the PV panels was monitored and recorded using an acquisition system, in real time, developed by the authors. This information was stored into a MySQL database (manager free database), the information decoding process and graphical representation was automatic and daily registered with analysis software variables, developed by the authors with Visual Studio 2010. As a result of this work, a model that predicts the possible behaviour of the power generated by each one of the technologies concerning the irradiance was obtained; this methodology can be replicated and adjusted to the conditions of a place where a PV system based on one of three technologies could be placed, evaluating which one has a better efficiency. Specifically for the city of Pasto, the best result was got by monocrystalline silicon panels.
- 1 June 2015
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-6
Study of the relationship between irradiance and power generated by PV panels based on different silicon technologies in the city of Pasto
This work presents the relationship between the irradiance, in the city of Pasto, and the power generated by three types of PV panels: monocrystalline, polycrystalline and amorphous silicon thin film. The irradiance data was collected in the year 2014, using the weather station DAVIS Advantage PRO 2.0. The power generated by the PV panels was monitored and recorded using an acquisition system, in real time, developed by the authors. This information was stored into a MySQL database (manager free database), the information decoding process and graphical representation was automatic and daily registered with analysis software variables, developed by the authors with Visual Studio 2010. As a result of this work, a model that predicts the possible behaviour of the power generated by each one of the technologies concerning the irradiance was obtained; this methodology can be replicated and adjusted to the conditions of a place where a PV system based on one of three technologies could be placed, evaluating which one has a better efficiency. Specifically for the city of Pasto, the best result was got by monocrystalline silicon panels.
- Open Access
- 1 May 2014
- Published by Universidad Distrital Francisco Jose de Caldas in Revista Científica
- Vol. 2 (19) , 158-167
Aprendizaje significativo por investigación: propuesta alternativa-Significant learning research: alternative proposal
Este trabajo forma parte de los desarrollos del grupo de investigación RAMPA de la Institución Universitaria Centro de Estudios Superiores María Goretti, que trabaja la línea de investigación energías renovables con la temática de variables meteorológicas. El estudio se centra en aplicar un modelo de enseñanza-aprendizaje denominado aprendizaje significativo por investigación, cuyo objetivo principal es que los estudiante aprendan a través del diseño la gestión y la evaluación de proyectos pedagógicos trasversales desarrollados a partir del esquema semilleros de investigación con una aplicación de aprendizaje basado en proyectos y enfocados dentro de un proceso investigativo de este grupo de investigación.
- 1 May 2014
- Published by Universidad Distrital Francisco Jose de Caldas in Revista Científica
- Vol. 2 (19) , 158-167
Open AccessAprendizaje significativo por investigación: propuesta alternativa-Significant learning research: alternative proposal
Este trabajo forma parte de los desarrollos del grupo de investigación RAMPA de la Institución Universitaria Centro de Estudios Superiores María Goretti, que trabaja la línea de investigación energías renovables con la temática de variables meteorológicas. El estudio se centra en aplicar un modelo de enseñanza-aprendizaje denominado aprendizaje significativo por investigación, cuyo objetivo principal es que los estudiante aprendan a través del diseño la gestión y la evaluación de proyectos pedagógicos trasversales desarrollados a partir del esquema semilleros de investigación con una aplicación de aprendizaje basado en proyectos y enfocados dentro de un proceso investigativo de este grupo de investigación.