Norbert Dillier
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Norbert Dillier has a total of 129 co-authors. Here are the top co-authors by number of shared publications:
- Flurin Pfiffner
Department of Otorhinolaryngology, Head and Neck Surgery, University Hospital Zurich, University of Zurich 1 , 8091 Zurich
3 shared publications - Leanne Sijgers
Department of Otorhinolaryngology, Head and Neck Surgery, University Hospital Zurich, University of Zurich 1 , 8091 Zurich
3 shared publications - Manuel Manrique
Department of Otorhinolaryngology, Clinica Universidad de Navarra, 31008 Pamplona, Spain
3 shared publications Thomas Lenarz
Medizinische Hochschule Hannover (MHH), Experimentelle HNO, Hannover, Germany
3 shared publicationsW K Lai
3 shared publicationsAndrzej Zarowski
2 shared publications
Latest Publications
- Open Access
- 1 February 2026
- Published by Acoustical Society of America (ASA) in The Journal of the Acoustical Society of America
- Vol. 159 (2) , 1316-1328
Spectrotemporal modulation sensitivity in cochlear implant users: Impact of noise carrier and modulation bandwidth on reaction time
Spectrotemporal modulation tests probe spectral and temporal resolution in cochlear implant (CI) users. This study investigated how carrier type and bandpass modulations influenced modulation detection performance. Nineteen CI users performed a reaction-time task involving the detection of spectral (0.25–2 cycles/octave) and/or temporal (4–16 Hz) modulations embedded in a broadband carrier. Carriers were either (1) a complex tone composed of 87 random-phase sinusoids spaced linearly at 100 Hz and weighted by a pink spectrum or (2) pink noise. Surprisingly, stimuli with dense spectral modulations were more readily detected when paired with the complex tone carrier. In contrast, the pink noise carrier yielded the expected low-pass spectral modulation transfer function profile. Electrodogram simulations based on CI sound processing strategies suggest that using a complex tone carrier with more closely spaced, logarithmically arranged tones may reduce unintended cues, such as spectral aliasing. Additionally, 2-octave limited bandwidth stimuli with a fixed temporal modulation rate (4 Hz) and spectral densities ranging from 0–2 cycles/octave were tested within broadband pink noise, centered at frequencies from 500 to 4000 Hz. Detection sensitivity was lowest at 500 Hz—a result supported by electrodograms—suggesting potential device processing limitations for spectrotemporal modulations at apical electrode sites.
- 1 February 2026
- Published by Acoustical Society of America (ASA) in The Journal of the Acoustical Society of America
- Vol. 159 (2) , 1316-1328
Open AccessSpectrotemporal modulation sensitivity in cochlear implant users: Impact of noise carrier and modulation bandwidth on reaction time
Spectrotemporal modulation tests probe spectral and temporal resolution in cochlear implant (CI) users. This study investigated how carrier type and bandpass modulations influenced modulation detection performance. Nineteen CI users performed a reaction-time task involving the detection of spectral (0.25–2 cycles/octave) and/or temporal (4–16 Hz) modulations embedded in a broadband carrier. Carriers were either (1) a complex tone composed of 87 random-phase sinusoids spaced linearly at 100 Hz and weighted by a pink spectrum or (2) pink noise. Surprisingly, stimuli with dense spectral modulations were more readily detected when paired with the complex tone carrier. In contrast, the pink noise carrier yielded the expected low-pass spectral modulation transfer function profile. Electrodogram simulations based on CI sound processing strategies suggest that using a complex tone carrier with more closely spaced, logarithmically arranged tones may reduce unintended cues, such as spectral aliasing. Additionally, 2-octave limited bandwidth stimuli with a fixed temporal modulation rate (4 Hz) and spectral densities ranging from 0–2 cycles/octave were tested within broadband pink noise, centered at frequencies from 500 to 4000 Hz. Detection sensitivity was lowest at 500 Hz—a result supported by electrodograms—suggesting potential device processing limitations for spectrotemporal modulations at apical electrode sites.
- Open Access
- 5 October 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Biomedical Engineering
- Vol. 71 (3) , 904-915
InterlACE Sound Coding for Unilateral and Bilateral Cochlear Implants
Objective: Cochlear implant signal processing strategies define the rules of how acoustic signals are converted into electrical stimulation patterns. Technological and anatomical limitations, however, impose constraints on the signal transmission and the accurate excitation of the auditory nerve. Acoustic signals are degraded throughout cochlear implant processing, and electrical signal interactions at the electrode-neuron interface constrain spectral and temporal precision. In this work, we propose a novel InterlACE signal processing strategy to counteract the occurring limitations. Methods: By replacing the maxima selection of the Advanced Combination Encoder strategy with a method that defines spatially and temporally alternating channels, InterlACE can compensate for discarded signal content of the conventional processing. The strategy can be extended bilaterally by introducing synchronized timing and channel selection. InterlACE was explored unilaterally and bilaterally by assessing speech intelligibility and spectral resolution. Five experienced bilaterally implanted cochlear implant recipients participated in the Oldenburg Sentence Recognition Test in background noise and the spectral ripple discrimination task. Results: The introduced alternating channel selection methodology shows promising outcomes for speech intelligibility but could not indicate better spectral ripple discrimination. Conclusion: InterlACE processing positively affects speech intelligibility, increases available unilateral and bilateral signal content, and may potentially counteract signal interactions at the electrode-neuron interface. Significance: This work shows how cochlear implant channel selection can be modified and extended bilaterally. The clinical impact of the modifications needs to be explored with a larger sample size.
- 5 October 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Biomedical Engineering
- Vol. 71 (3) , 904-915
Open AccessInterlACE Sound Coding for Unilateral and Bilateral Cochlear Implants
Objective: Cochlear implant signal processing strategies define the rules of how acoustic signals are converted into electrical stimulation patterns. Technological and anatomical limitations, however, impose constraints on the signal transmission and the accurate excitation of the auditory nerve. Acoustic signals are degraded throughout cochlear implant processing, and electrical signal interactions at the electrode-neuron interface constrain spectral and temporal precision. In this work, we propose a novel InterlACE signal processing strategy to counteract the occurring limitations. Methods: By replacing the maxima selection of the Advanced Combination Encoder strategy with a method that defines spatially and temporally alternating channels, InterlACE can compensate for discarded signal content of the conventional processing. The strategy can be extended bilaterally by introducing synchronized timing and channel selection. InterlACE was explored unilaterally and bilaterally by assessing speech intelligibility and spectral resolution. Five experienced bilaterally implanted cochlear implant recipients participated in the Oldenburg Sentence Recognition Test in background noise and the spectral ripple discrimination task. Results: The introduced alternating channel selection methodology shows promising outcomes for speech intelligibility but could not indicate better spectral ripple discrimination. Conclusion: InterlACE processing positively affects speech intelligibility, increases available unilateral and bilateral signal content, and may potentially counteract signal interactions at the electrode-neuron interface. Significance: This work shows how cochlear implant channel selection can be modified and extended bilaterally. The clinical impact of the modifications needs to be explored with a larger sample size.
- Open Access
- 10 February 2022
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Biomedical Engineering
- Vol. 69 (8) , 2533-2544
Predicting Cochlear Implant Electrode Placement Using Monopolar, Three-Point and Four-Point Impedance Measurements
Objective: This study aimed to investigate the relationship between cochlear implant (CI) electrode distances to the cochlea's inner wall (the modiolus) and electrical impedance measurements made at the CI's electrode contacts. We introduced a protocol for “three-point impedances” in which we recorded bipolar impedances in response to monopolar stimulation at a neighboring electrode. We aimed to assess the usability of three-point impedances and two existing CI impedance measurement methods (monopolar and four-point impedances) for predicting electrode positioning during CI insertion. Methods: Impedances were recorded during stepwise CI electrode array insertions in cadaveric human temporal bones. The positioning of the electrodes with respect to the modiolus was assessed at each step using cone beam computed tomography. Linear mixed regression analysis was performed to assess the relationship between the impedances and electrode-modiolar distances. The experimental results were compared to clinical impedance data and to an existing lumped-element model of an implanted CI. Results: Three-point and four-point impedances strongly correlated with electrode-modiolar distance. In contrast, monopolar impedances were only minimally affected by changes in electrode positioning with respect to the modiolus. An overall model specificity of 62% was achieved when incorporating all impedance parameters. This specificity could be increased beyond 73% when prior expectations of electrode positioning were incorporated in the model. Conclusion: Three-point and four-point impedances are promising measures to predict electrode-modiolar distance in real-time during CI insertion. Significance: This work shows how electrical impedance measurements can be used to predict the CI's electrode positioning in a biologically realistic model.
- 10 February 2022
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Biomedical Engineering
- Vol. 69 (8) , 2533-2544
Open AccessPredicting Cochlear Implant Electrode Placement Using Monopolar, Three-Point and Four-Point Impedance Measurements
Objective: This study aimed to investigate the relationship between cochlear implant (CI) electrode distances to the cochlea's inner wall (the modiolus) and electrical impedance measurements made at the CI's electrode contacts. We introduced a protocol for “three-point impedances” in which we recorded bipolar impedances in response to monopolar stimulation at a neighboring electrode. We aimed to assess the usability of three-point impedances and two existing CI impedance measurement methods (monopolar and four-point impedances) for predicting electrode positioning during CI insertion. Methods: Impedances were recorded during stepwise CI electrode array insertions in cadaveric human temporal bones. The positioning of the electrodes with respect to the modiolus was assessed at each step using cone beam computed tomography. Linear mixed regression analysis was performed to assess the relationship between the impedances and electrode-modiolar distances. The experimental results were compared to clinical impedance data and to an existing lumped-element model of an implanted CI. Results: Three-point and four-point impedances strongly correlated with electrode-modiolar distance. In contrast, monopolar impedances were only minimally affected by changes in electrode positioning with respect to the modiolus. An overall model specificity of 62% was achieved when incorporating all impedance parameters. This specificity could be increased beyond 73% when prior expectations of electrode positioning were incorporated in the model. Conclusion: Three-point and four-point impedances are promising measures to predict electrode-modiolar distance in real-time during CI insertion. Significance: This work shows how electrical impedance measurements can be used to predict the CI's electrode positioning in a biologically realistic model.
- Open Access
- 1 January 2021
- Published by SAGE Publications in Trends in Hearing
- Vol. 25
Simultaneous Intra- and Extracochlear Electrocochleography During Cochlear Implantation to Enhance Response Interpretation
The use of electrocochleography (ECochG) for providing real-time feedback of cochlear function during cochlear implantation is receiving increased attention for preventing cochlear trauma and preserving residual hearing. Although various studies investigated the relationship between intra-operative ECochG measurements and surgical outcomes in recent years, the limited interpretability of ECochG response changes leads to conflicting study results and prevents the adoption of this method for clinical use. Specifically, the movement of the recording electrode with respect to the different signal generators in intracochlear recordings makes the interpretation of signal changes with respect to cochlear trauma difficult. Here, we demonstrate that comparison of ECochG signals recorded simultaneously from intracochlear locations and from a fixed extracochlear location can potentially allow a differentiation between traumatic and atraumatic signal changes in intracochlear recordings. We measured ECochG responses to 500 Hz tone bursts with alternating starting phases during cochlear implant insertions in six human cochlear implant recipients. Our results show that an amplitude decrease with associated near 180° phase shift and harmonic distortions in the intracochlear difference curve during the first half of insertion was not accompanied by a decrease in the extracochlear difference curve’s amplitude (n = 1), while late amplitude decreases in intracochlear difference curves (near full insertion, n = 2) did correspond to extracochlear amplitude decreases. These findings suggest a role for phase shifts, harmonic distortions, and recording location in interpreting intracochlear ECochG responses.
- 1 January 2021
- Published by SAGE Publications in Trends in Hearing
- Vol. 25
Open AccessSimultaneous Intra- and Extracochlear Electrocochleography During Cochlear Implantation to Enhance Response Interpretation
The use of electrocochleography (ECochG) for providing real-time feedback of cochlear function during cochlear implantation is receiving increased attention for preventing cochlear trauma and preserving residual hearing. Although various studies investigated the relationship between intra-operative ECochG measurements and surgical outcomes in recent years, the limited interpretability of ECochG response changes leads to conflicting study results and prevents the adoption of this method for clinical use. Specifically, the movement of the recording electrode with respect to the different signal generators in intracochlear recordings makes the interpretation of signal changes with respect to cochlear trauma difficult. Here, we demonstrate that comparison of ECochG signals recorded simultaneously from intracochlear locations and from a fixed extracochlear location can potentially allow a differentiation between traumatic and atraumatic signal changes in intracochlear recordings. We measured ECochG responses to 500 Hz tone bursts with alternating starting phases during cochlear implant insertions in six human cochlear implant recipients. Our results show that an amplitude decrease with associated near 180° phase shift and harmonic distortions in the intracochlear difference curve during the first half of insertion was not accompanied by a decrease in the extracochlear difference curve’s amplitude (n = 1), while late amplitude decreases in intracochlear difference curves (near full insertion, n = 2) did correspond to extracochlear amplitude decreases. These findings suggest a role for phase shifts, harmonic distortions, and recording location in interpreting intracochlear ECochG responses.
- 29 June 2010
- Published by Taylor & Francis in International Journal of Audiology
- Vol. 49 (9) , 657-666
Speech perception performance as a function of stimulus pulse rate and processing strategy preference for the Cochlear™ Nucleus®CI24RE device: Relation to perceptual threshold and loudness comfort profiles
Current cochlear implants can operate at high pulse rates. The effect of increasing pulse rate on speech performance is not yet clear. Habituation to low rates may affect the outcome. This paper presents the results of three subsequent studies using different experimental paradigms, applying the Nucleus CI24RE device, and conducted by ten European implant teams. Pulse rate per channel varied from 500 to 3500 pulses per second with ACE and from 1200 to 3500 pps with CIS strategy. The results showed that the first rate presented had little effect on the finally preferred rate. Lower rates were preferred. The effect of pulse rate on word scores of post-linguistic implantees was small; high rates tended to give lower scores. However, there were no significant differences between the word scores across subjects if collected at the individually preferred pulse rate. High pulse rates were preferred when the post-implantation threshold was low.
- 29 June 2010
- Published by Taylor & Francis in International Journal of Audiology
- Vol. 49 (9) , 657-666
Speech perception performance as a function of stimulus pulse rate and processing strategy preference for the Cochlear™ Nucleus®CI24RE device: Relation to perceptual threshold and loudness comfort profiles
Current cochlear implants can operate at high pulse rates. The effect of increasing pulse rate on speech performance is not yet clear. Habituation to low rates may affect the outcome. This paper presents the results of three subsequent studies using different experimental paradigms, applying the Nucleus CI24RE device, and conducted by ten European implant teams. Pulse rate per channel varied from 500 to 3500 pulses per second with ACE and from 1200 to 3500 pps with CIS strategy. The results showed that the first rate presented had little effect on the finally preferred rate. Lower rates were preferred. The effect of pulse rate on word scores of post-linguistic implantees was small; high rates tended to give lower scores. However, there were no significant differences between the word scores across subjects if collected at the individually preferred pulse rate. High pulse rates were preferred when the post-implantation threshold was low.
- Open Access
- 17 March 2009
- Published by Oxford University Press (OUP) in Brain
- Vol. 132 (7) , 1967-1979
Evaluation of evoked potentials to dyadic tones after cochlear implantation
Auditory evoked potentials are tools widely used to assess auditory cortex functions in clinical context. However, in cochlear implant users, electrophysiological measures are challenging due to implant-created artefacts in the EEG. Here, we used independent component analysis to reduce cochlear implant-related artefacts in event-related EEGs of cochlear implant users (n = 12), which allowed detailed spatio-temporal evaluation of auditory evoked potentials by means of dipole source analysis. The present study examined hemispheric asymmetries of auditory evoked potentials to musical sounds in cochlear implant users to evaluate the effect of this type of implantation on neuronal activity. In particular, implant users were presented with two dyadic tonal intervals in an active oddball design and in a passive listening condition. Principally, the results show that independent component analysis is an efficient approach that enables the study of neurophysiological mechanisms of restored auditory function in cochlear implant users. Moreover, our data indicate altered hemispheric asymmetries for dyadic tone processing in implant users compared with listeners with normal hearing (n = 12). We conclude that the evaluation of auditory evoked potentials are of major relevance to understanding auditory cortex function after cochlear implantation and could be of substantial clinical value by indicating the maturation/reorganization of the auditory system after implantation.
- 17 March 2009
- Published by Oxford University Press (OUP) in Brain
- Vol. 132 (7) , 1967-1979
Open AccessEvaluation of evoked potentials to dyadic tones after cochlear implantation
Auditory evoked potentials are tools widely used to assess auditory cortex functions in clinical context. However, in cochlear implant users, electrophysiological measures are challenging due to implant-created artefacts in the EEG. Here, we used independent component analysis to reduce cochlear implant-related artefacts in event-related EEGs of cochlear implant users (n = 12), which allowed detailed spatio-temporal evaluation of auditory evoked potentials by means of dipole source analysis. The present study examined hemispheric asymmetries of auditory evoked potentials to musical sounds in cochlear implant users to evaluate the effect of this type of implantation on neuronal activity. In particular, implant users were presented with two dyadic tonal intervals in an active oddball design and in a passive listening condition. Principally, the results show that independent component analysis is an efficient approach that enables the study of neurophysiological mechanisms of restored auditory function in cochlear implant users. Moreover, our data indicate altered hemispheric asymmetries for dyadic tone processing in implant users compared with listeners with normal hearing (n = 12). We conclude that the evaluation of auditory evoked potentials are of major relevance to understanding auditory cortex function after cochlear implantation and could be of substantial clinical value by indicating the maturation/reorganization of the auditory system after implantation.
- 1 January 2009
- Published by Taylor & Francis in International Journal of Audiology
- Vol. 48 (9) , 645-654
TNRT profiles with the Nucleus Research Platform 8 system
This study investigates the effect of the Nucleus CI24RE implant's neural response telemetry (NRT) system, which has less internal noise compared to its predecessor, the CI24M/R implant, on the NRT threshold (TNRT) profile across the array. CI24M/R measurements were simulated by ignoring CI24RE measurements with response amplitudes below 50 uV. Comparisons of the estimated TNRTs from the CI24RE measurements and the CI24M/R simulations suggest that, apart from a constant level difference, the TNRT profiles from the newer implant generally would not have differed very much from those of its predecessor. This view was also reflected by principal component analysis (PCA) results which revealed a ‘shift’ component similar to that reported by Smoorenburg et al (2002). On the whole, there is no indication that current practices of using the TNRT profiles for assisting with speech processor programming need to be revised for the CI24RE implant.
- 1 January 2009
- Published by Taylor & Francis in International Journal of Audiology
- Vol. 48 (9) , 645-654
TNRT profiles with the Nucleus Research Platform 8 system
This study investigates the effect of the Nucleus CI24RE implant's neural response telemetry (NRT) system, which has less internal noise compared to its predecessor, the CI24M/R implant, on the NRT threshold (TNRT) profile across the array. CI24M/R measurements were simulated by ignoring CI24RE measurements with response amplitudes below 50 uV. Comparisons of the estimated TNRTs from the CI24RE measurements and the CI24M/R simulations suggest that, apart from a constant level difference, the TNRT profiles from the newer implant generally would not have differed very much from those of its predecessor. This view was also reflected by principal component analysis (PCA) results which revealed a ‘shift’ component similar to that reported by Smoorenburg et al (2002). On the whole, there is no indication that current practices of using the TNRT profiles for assisting with speech processor programming need to be revised for the CI24RE implant.
- 1 January 2009
- Published by Maney Publishing in Cochlear Implants International
Neural adaptation and the ECAP response threshold: A pilot study
The electrically evoked compound action potential (ECAP) amplitude resulting from a train of pulses of finite duration (100 ms or 200 ms) was found to vary inversely to the stimulation rate (pulse rate), corroborating well with neural adaptation results from a previous study (Dillier et al., 2005). Amplitude growth functions based on these adapted responses yield thresholds (TNRT) that increase with increasing pulse rate, contrary to behavioural thresholds, which are known to vary inversely with the stimulation rate. Adaptation effects are therefore a confounding factor that must be accounted for when attempting to compare behavioural and objective measures
- 1 January 2009
- Published by Maney Publishing in Cochlear Implants International
Neural adaptation and the ECAP response threshold: A pilot study
The electrically evoked compound action potential (ECAP) amplitude resulting from a train of pulses of finite duration (100 ms or 200 ms) was found to vary inversely to the stimulation rate (pulse rate), corroborating well with neural adaptation results from a previous study (Dillier et al., 2005). Amplitude growth functions based on these adapted responses yield thresholds (TNRT) that increase with increasing pulse rate, contrary to behavioural thresholds, which are known to vary inversely with the stimulation rate. Adaptation effects are therefore a confounding factor that must be accounted for when attempting to compare behavioural and objective measures
- 1 August 2007
- Published by Wolters Kluwer Health in Ear & Hearing
- Vol. 28 (4) , 558-570
Clinical Results of AutoNRT,™ a Completely Automatic ECAP Recording System for Cochlear Implants
Objective: AutoNRT™ is the completely automatic electrically evoked compound action potential (ECAP) measuring algorithm in the recently released Nucleus Freedom cochlear implant system. AutoNRT allows clinicians to automatically record T-NRT profiles that in turn can be used as a guide for initial fitting. The algorithm consists of a pattern recognition part that judges if the traces contain an ECAP and an intelligent flow that optimizes the measurement parameters and finds the ECAP threshold (T-NRT). The objective of this study was to determine how accurate, reliable, and fast the automatic measurements are. Design: Data on more than 400 electrodes were collected as part of the multicenter clinical trial of the Nucleus Freedom cochlear implant system. T-NRT values determined by the algorithm were compared with T-NRT determinations on the same data by different human observers. Also, the time the measurements took was analyzed. Results: In 90% of the cases, the absolute difference between the AutoNRT and the human observer determined T-NRT was less than 9 CL; the median absolute difference was 3 CL. A second experiment, in which a group of human observers were asked to analyze NRT data, showed high variability in T-NRT; in some cases, two experienced clinicians disagreed by more than 30 current levels. Compared with the group, AutoNRT performed as well as the “average” clinician, with the advantage that the AutoNRT threshold determinations are objective. Analysis of the timing data showed an average intraoperative measurement time of less than 20 sec per electrode with a standard deviation of 5 sec, suggesting that the total array of 22 electrodes can be measured intraoperatively in about 7 minutes on average. Conclusions: AutoNRT provides comparable accuracy to an average clinician but with the added benefit of significant time savings over manual recordings. This makes it a valuable tool for clinical measurement of ECAP threshold in cochlear implant recipients.
- 1 August 2007
- Published by Wolters Kluwer Health in Ear & Hearing
- Vol. 28 (4) , 558-570
Clinical Results of AutoNRT,™ a Completely Automatic ECAP Recording System for Cochlear Implants
Objective: AutoNRT™ is the completely automatic electrically evoked compound action potential (ECAP) measuring algorithm in the recently released Nucleus Freedom cochlear implant system. AutoNRT allows clinicians to automatically record T-NRT profiles that in turn can be used as a guide for initial fitting. The algorithm consists of a pattern recognition part that judges if the traces contain an ECAP and an intelligent flow that optimizes the measurement parameters and finds the ECAP threshold (T-NRT). The objective of this study was to determine how accurate, reliable, and fast the automatic measurements are. Design: Data on more than 400 electrodes were collected as part of the multicenter clinical trial of the Nucleus Freedom cochlear implant system. T-NRT values determined by the algorithm were compared with T-NRT determinations on the same data by different human observers. Also, the time the measurements took was analyzed. Results: In 90% of the cases, the absolute difference between the AutoNRT and the human observer determined T-NRT was less than 9 CL; the median absolute difference was 3 CL. A second experiment, in which a group of human observers were asked to analyze NRT data, showed high variability in T-NRT; in some cases, two experienced clinicians disagreed by more than 30 current levels. Compared with the group, AutoNRT performed as well as the “average” clinician, with the advantage that the AutoNRT threshold determinations are objective. Analysis of the timing data showed an average intraoperative measurement time of less than 20 sec per electrode with a standard deviation of 5 sec, suggesting that the total array of 22 electrodes can be measured intraoperatively in about 7 minutes on average. Conclusions: AutoNRT provides comparable accuracy to an average clinician but with the added benefit of significant time savings over manual recordings. This makes it a valuable tool for clinical measurement of ECAP threshold in cochlear implant recipients.
- Open Access
- 1 April 2007
- Published by Wolters Kluwer Health in Ear & Hearing
- Vol. 28 (2) , 46S-48S
Performance and Preference for ACE Stimulation Rates Obtained with Nucleus RP 8 and Freedom System
Cochlear recently released the Nucleus Freedom System which has been based on the Nucleus Research Platform 8. Both systems make use of the same implant, the CI24RE, which includes expanded total stimulation rates up to 32 kHz. In this study the performance of the ACE strategy at 500, 1200 and 3500 pps/channel was investigated using an ABC-CBA design. At the end of each period speech tests were performed. In the CBA phase the patients completed a comparative questionnaire to determine the subjective rate preference. Preliminary results in 13 recipients indicate no differences in for the ACE strategy at rates ranging from 500 pps to 3500 pps/channel.
- 1 April 2007
- Published by Wolters Kluwer Health in Ear & Hearing
- Vol. 28 (2) , 46S-48S
Open AccessPerformance and Preference for ACE Stimulation Rates Obtained with Nucleus RP 8 and Freedom System
Cochlear recently released the Nucleus Freedom System which has been based on the Nucleus Research Platform 8. Both systems make use of the same implant, the CI24RE, which includes expanded total stimulation rates up to 32 kHz. In this study the performance of the ACE strategy at 500, 1200 and 3500 pps/channel was investigated using an ABC-CBA design. At the end of each period speech tests were performed. In the CBA phase the patients completed a comparative questionnaire to determine the subjective rate preference. Preliminary results in 13 recipients indicate no differences in for the ACE strategy at rates ranging from 500 pps to 3500 pps/channel.