Pallavi Deshpande
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Pallavi Deshpande has a total of 37 co-authors. Here are the top co-authors by number of shared publications:
Sheila MacNeil
Department of Materials Science and Engineering, University of Sheffield
8 shared publications- Frederik Claeyssens
University of Sheffield
5 shared publications - Anthony J. Ryan
Grantham Centre for Sustainable Futures, University of Sheffield, Sheffield, UK
4 shared publications - Ilida Ortega
The School of Clinical Dentistry, The University of Sheffield, 19 Claremont Crescent, Sheffield S10 2TA, UK
4 shared publications Charanya Ramachandran
L. V. Prasad Eye Institute
3 shared publications- Sheila MacNeil
University of Sheffield
3 shared publications
Latest Publications
- Open Access
- 5 February 2015
- Published by Association for Research in Vision and Ophthalmology (ARVO) in Investigative Ophthalmology & Visual Science
- Vol. 56 (3) , 1553-1561
Rocking Media Over Ex Vivo Corneas Improves This Model and Allows the Study of the Effect of Proinflammatory Cytokines on Wound Healing
The aim of this work was to develop an in vitro cornea model to study the effect of proinflammatory cytokines on wound healing. Initial studies investigated how to maintain the ex vivo models for up to 4 weeks without loss of epithelium. To study the effect of cytokines, corneas were cultured with the interleukins IL-17A, IL-22, or a combination of IL-17A and IL-22, or lipopolysaccharide (LPS). The effect of IL-17A on wound healing was then examined. With static culture conditions, organ cultures deteriorated within 2 weeks. With gentle rocking of media over the corneas and carbon dioxide perfusion, the ex vivo models survived for up to 4 weeks without loss of epithelium. The cytokine that caused the most damage to the cornea was IL-17A. Under static conditions, wound healing of the central corneal epithelium occurred within 9 days, but only a single-layered epithelium formed whether the cornea was exposed to IL-17A or not. With rocking of media gently over the corneas, a multilayered epithelium was achieved 9 days after wounding. In the presence of IL-17A, however, there was no wound healing evident. Characterization of the cells showed that wherever epithelium was present, both differentiated cells and highly proliferative cells were present. We propose that introducing rocking to extend the effective working life of this model and the introduction of IL-17A to this model to induce aspects of inflammation extend its usefulness to study the effects of agents that influence corneal regeneration under normal and inflamed conditions.
- 5 February 2015
- Published by Association for Research in Vision and Ophthalmology (ARVO) in Investigative Ophthalmology & Visual Science
- Vol. 56 (3) , 1553-1561
Open AccessRocking Media Over Ex Vivo Corneas Improves This Model and Allows the Study of the Effect of Proinflammatory Cytokines on Wound Healing
The aim of this work was to develop an in vitro cornea model to study the effect of proinflammatory cytokines on wound healing. Initial studies investigated how to maintain the ex vivo models for up to 4 weeks without loss of epithelium. To study the effect of cytokines, corneas were cultured with the interleukins IL-17A, IL-22, or a combination of IL-17A and IL-22, or lipopolysaccharide (LPS). The effect of IL-17A on wound healing was then examined. With static culture conditions, organ cultures deteriorated within 2 weeks. With gentle rocking of media over the corneas and carbon dioxide perfusion, the ex vivo models survived for up to 4 weeks without loss of epithelium. The cytokine that caused the most damage to the cornea was IL-17A. Under static conditions, wound healing of the central corneal epithelium occurred within 9 days, but only a single-layered epithelium formed whether the cornea was exposed to IL-17A or not. With rocking of media gently over the corneas, a multilayered epithelium was achieved 9 days after wounding. In the presence of IL-17A, however, there was no wound healing evident. Characterization of the cells showed that wherever epithelium was present, both differentiated cells and highly proliferative cells were present. We propose that introducing rocking to extend the effective working life of this model and the introduction of IL-17A to this model to induce aspects of inflammation extend its usefulness to study the effects of agents that influence corneal regeneration under normal and inflamed conditions.
- Open Access
- 12 September 2014
- Published by MyJove Corporation in Journal of Visualized Experiments
- No. 91,p. e51826-51826
Combination of Microstereolithography and Electrospinning to Produce Membranes Equipped with Niches for Corneal Regeneration
Corneal problems affect millions of people worldwide reducing their quality of life significantly. Corneal disease can be caused by illnesses such as Aniridia or Steven Johnson Syndrome as well as by external factors such as chemical burns or radiation. Current treatments are (i) the use of corneal grafts and (ii) the use of stem cell expanded in the laboratory and delivered on carriers (e.g., amniotic membrane); these treatments are relatively successful but unfortunately they can fail after 3-5 years. There is a need to design and manufacture new corneal biomaterial devices able to mimic in detail the physiological environment where stem cells reside in the cornea. Limbal stem cells are located in the limbus (circular area between cornea and sclera) in specific niches known as the Palisades of Vogt. In this work we have developed a new platform technology which combines two cutting-edge manufacturing techniques (microstereolithography and electrospinning) for the fabrication of corneal membranes that mimic to a certain extent the limbus. Our membranes contain artificial micropockets which aim to provide cells with protection as the Palisades of Vogt do in the eye.
- 12 September 2014
- Published by MyJove Corporation in Journal of Visualized Experiments
- No. 91,p. e51826-51826
Open AccessCombination of Microstereolithography and Electrospinning to Produce Membranes Equipped with Niches for Corneal Regeneration
Corneal problems affect millions of people worldwide reducing their quality of life significantly. Corneal disease can be caused by illnesses such as Aniridia or Steven Johnson Syndrome as well as by external factors such as chemical burns or radiation. Current treatments are (i) the use of corneal grafts and (ii) the use of stem cell expanded in the laboratory and delivered on carriers (e.g., amniotic membrane); these treatments are relatively successful but unfortunately they can fail after 3-5 years. There is a need to design and manufacture new corneal biomaterial devices able to mimic in detail the physiological environment where stem cells reside in the cornea. Limbal stem cells are located in the limbus (circular area between cornea and sclera) in specific niches known as the Palisades of Vogt. In this work we have developed a new platform technology which combines two cutting-edge manufacturing techniques (microstereolithography and electrospinning) for the fabrication of corneal membranes that mimic to a certain extent the limbus. Our membranes contain artificial micropockets which aim to provide cells with protection as the Palisades of Vogt do in the eye.
- 1 July 2014
- Published by Elsevier in Acta Biomaterialia
- Vol. 10 (7) , 3029-3037
Amine functional hydrogels as selective substrates for corneal epithelialization
- 1 July 2014
- Published by Elsevier in Acta Biomaterialia
- Vol. 10 (7) , 3029-3037
Amine functional hydrogels as selective substrates for corneal epithelialization
- 1 July 2013
- Published by Elsevier in Biomaterials
- Vol. 34 (21) , 5088-5106
Simplifying corneal surface regeneration using a biodegradable synthetic membrane and limbal tissue explants
- 1 July 2013
- Published by Elsevier in Biomaterials
- Vol. 34 (21) , 5088-5106
Simplifying corneal surface regeneration using a biodegradable synthetic membrane and limbal tissue explants
- 25 April 2013
- Published by Springer Nature
- Vol. 1014, 179-185
Cultivation of Limbal Epithelial Cells on Electrospun Poly (lactide-co-glycolide) Scaffolds for Delivery to the Cornea
In delivering tissues to the body, both natural and synthetic materials have been used. Currently, a natural membrane, the human amniotic membrane (AM), is used to deliver limbal epithelial cells (LEC) to the cornea. AM presents inherent problems with structural variation and requires extensive serological screening before use. Therefore alternatives are required to improve the predictability in clinical outcomes and economic costs associated with the use of this biological substrate. In this chapter, we describe the development of an alternative, structurally simple, synthetic biodegradable electrospun scaffold based on poly(lactide-co-glycolide) (PLGA: materials used in dissolvable sutures) to replace AM.
- 25 April 2013
- Published by Springer Nature
- Vol. 1014, 179-185
Cultivation of Limbal Epithelial Cells on Electrospun Poly (lactide-co-glycolide) Scaffolds for Delivery to the Cornea
In delivering tissues to the body, both natural and synthetic materials have been used. Currently, a natural membrane, the human amniotic membrane (AM), is used to deliver limbal epithelial cells (LEC) to the cornea. AM presents inherent problems with structural variation and requires extensive serological screening before use. Therefore alternatives are required to improve the predictability in clinical outcomes and economic costs associated with the use of this biological substrate. In this chapter, we describe the development of an alternative, structurally simple, synthetic biodegradable electrospun scaffold based on poly(lactide-co-glycolide) (PLGA: materials used in dissolvable sutures) to replace AM.
- 17 April 2013
- Published by IOP Publishing in Biofabrication
- Vol. 5 (2) , 025008
Development of a microfabricated artificial limbus with micropockets for cell delivery to the cornea
The aim of this study was to develop a synthetic alternative to the human corneal limbus for use initially as an ex vivo model in which to study corneal stem cell function within a niche environment and ultimately to develop an implantable limbus for future clinical use. Microstereolithography was used for the fabrication of polyethylene glycol diacrylate (PEGDA) based rings on a macroscopic (1.2 cm) scale containing unique microfeatures (pockets) which were then modified with fibronectin to promote cell adhesion. These rings were designed to mimic the limbal area of the eye containing structures of the approximate size and shape of the stem cell microenvironments found in the palisades of Vogt. The attachment of rabbit limbal fibroblasts and rabbit limbal epithelial cells to the PEGDA rings was increased by pretreating the microfabricated structures with biotinylated fibronectin. Cell outgrowth from fibronectin coated microfabricated structures was 50% greater than from rings without structures or fibronectin coating. The cell loaded rings were then placed on an ex vivo wounded cornea model and the outgrowth of cells to form a multilayered epithelium was observed. We suggest this is a new approach to investigating limbal stem cells niches and the first steps towards a new approach for corneal regeneration.
- 17 April 2013
- Published by IOP Publishing in Biofabrication
- Vol. 5 (2) , 025008
Development of a microfabricated artificial limbus with micropockets for cell delivery to the cornea
The aim of this study was to develop a synthetic alternative to the human corneal limbus for use initially as an ex vivo model in which to study corneal stem cell function within a niche environment and ultimately to develop an implantable limbus for future clinical use. Microstereolithography was used for the fabrication of polyethylene glycol diacrylate (PEGDA) based rings on a macroscopic (1.2 cm) scale containing unique microfeatures (pockets) which were then modified with fibronectin to promote cell adhesion. These rings were designed to mimic the limbal area of the eye containing structures of the approximate size and shape of the stem cell microenvironments found in the palisades of Vogt. The attachment of rabbit limbal fibroblasts and rabbit limbal epithelial cells to the PEGDA rings was increased by pretreating the microfabricated structures with biotinylated fibronectin. Cell outgrowth from fibronectin coated microfabricated structures was 50% greater than from rings without structures or fibronectin coating. The cell loaded rings were then placed on an ex vivo wounded cornea model and the outgrowth of cells to form a multilayered epithelium was observed. We suggest this is a new approach to investigating limbal stem cells niches and the first steps towards a new approach for corneal regeneration.
- 1 March 2013
- Published by Elsevier in Acta Biomaterialia
- Vol. 9 (3) , 5511-5520
Combined microfabrication and electrospinning to produce 3-D architectures for corneal repair
- 1 March 2013
- Published by Elsevier in Acta Biomaterialia
- Vol. 9 (3) , 5511-5520
Combined microfabrication and electrospinning to produce 3-D architectures for corneal repair
- 1 July 2011
- Published by Elsevier in International Journal of Pharmaceutics
- Vol. 414 (1-2) , 104-111
Biocompatible hydrogels based on hyaluronic acid cross-linked with a polyaspartamide derivative as delivery systems for epithelial limbal cells
- 1 July 2011
- Published by Elsevier in International Journal of Pharmaceutics
- Vol. 414 (1-2) , 104-111
Biocompatible hydrogels based on hyaluronic acid cross-linked with a polyaspartamide derivative as delivery systems for epithelial limbal cells
- 10 May 2010
- Published by Taylor & Francis in Regenerative Medicine
- Vol. 5 (3) , 395-401
Using Poly(Lactide-Co-Glycolide) Electrospun Scaffolds to Deliver Cultured Epithelial Cells to the Cornea
To assess the potential of electrospun poly(lactide-co-glycolide) membranes to provide a biodegradable cell carrier system for limbal epithelial cells. 50:50 poly(lactide-co-glycolide) scaffolds were spun, sterilized and seeded with primary rabbit limbal epithelial cells. Cells were cultured on the scaffolds for 2 weeks and then examined by confocal microscopy, cryosectioning and scanning-electron microscopy. The tensile strength of scaffolds before and after annealing and sterilization was also studied. The limbal cells had formed a continuous multilayer of cells on either side of the scaffold. Scaffolds with cells showed signs of the onset of degradation within 2 weeks in culture media at 37 degrees C. Scaffolds that were annealed resulted in a more brittle and stiff mat. We suggest this carrier membrane could be used as a replacement for the human amniotic membrane in the treatment of limbal stem cell deficiency, lowering the risk of disease transmission to the patient.
- 10 May 2010
- Published by Taylor & Francis in Regenerative Medicine
- Vol. 5 (3) , 395-401
Using Poly(Lactide-Co-Glycolide) Electrospun Scaffolds to Deliver Cultured Epithelial Cells to the Cornea
To assess the potential of electrospun poly(lactide-co-glycolide) membranes to provide a biodegradable cell carrier system for limbal epithelial cells. 50:50 poly(lactide-co-glycolide) scaffolds were spun, sterilized and seeded with primary rabbit limbal epithelial cells. Cells were cultured on the scaffolds for 2 weeks and then examined by confocal microscopy, cryosectioning and scanning-electron microscopy. The tensile strength of scaffolds before and after annealing and sterilization was also studied. The limbal cells had formed a continuous multilayer of cells on either side of the scaffold. Scaffolds with cells showed signs of the onset of degradation within 2 weeks in culture media at 37 degrees C. Scaffolds that were annealed resulted in a more brittle and stiff mat. We suggest this carrier membrane could be used as a replacement for the human amniotic membrane in the treatment of limbal stem cell deficiency, lowering the risk of disease transmission to the patient.