Peter Jenkins
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Research Interests
Peter Jenkins has a total of 15 co-authors. Here are the top co-authors by number of shared publications:
- Jan Tunér
Swedish Laser Medical Society
2 shared publications Lars Hode
Swedish Laser-Medical Society (Sweden)
2 shared publicationsTomas Hode
Immunophotonics, Inc. (USA)
2 shared publications- Anu Koivula
VTT Technical Research Centre of Finland Ltd, Espoo, Finland
1 shared publication Anu Vaari
VTT Technical Research Centre of Finland
1 shared publicationDonald Duncan
Oregon Health & Science Univ. (USA)
1 shared publication
Latest Publications
- Open Access
- 1 March 2016
- Published by SAGE Publications in Photomedicine and Laser Surgery
- Vol. 34 (3) , 91-92
Parameter Reproducibility in Photobiomodulation
Photobiomodulation, Photomedicine, and Laser Surgery
- 1 March 2016
- Published by SAGE Publications in Photomedicine and Laser Surgery
- Vol. 34 (3) , 91-92
Open AccessParameter Reproducibility in Photobiomodulation
Photobiomodulation, Photomedicine, and Laser Surgery
- Top Cited Papers
- 1 December 2011
- Published by SAGE Publications in Photomedicine and Laser Surgery
- Vol. 29 (12) , 785-787
How to Report Low-Level Laser Therapy (LLLT)/Photomedicine Dose and Beam Parameters in Clinical and Laboratory Studies
Background: Dose and beam parameters are critical for successful laser, LED, and other light therapy treatments; however, in our experience, researchers frequently make critical errors and omissions when submitting papers for publication. Journals frequently publish studies with missing data, mathematical errors, and no reported verification of beam parameters. This makes reproducibility impossible, and further confounds an already complex subject. Objective: This article is intended to be a reference document for non-physicist researchers conducting low-level laser therapy (LLLT) laboratory studies and clinical trials to help them design and report the beam and dose aspects of their trials. Recommendations: It provides a checklist to help LLLT researchers understand and report all the necessary parameters for a repeatable scientific study. It includes the eight most important beam parameters to report, which are: wavelength, power, irradiation time, beam area at the skin or culture surface (this is not necessarily the same as the aperture size), pulse parameters, anatomical location, number of treatments, and interval between treatments. The three commonly used dose parameters are time, energy, and energy density. In addition, more thorough reporting would include coherence, application technique (contact, projection, scanning, pressure), beam profile, and spectral width, as these may also be considered important. Beam power often decreases as the device warms up and as the device ages; therefore, this should be checked routinely during an experiment/trial. Measurements of beam area and beam power require special instruments and trained technicians to operate them. Power measurements should be taken before, after, and at frequent intervals during research trials. Conclusion: Reviewers should insist that the minimum eight most important beam parameters are included, and authors should take care to measure and record these accurately before, during, and after an experiment or clinical trial.
- 1 December 2011
- Published by SAGE Publications in Photomedicine and Laser Surgery
- Vol. 29 (12) , 785-787
Top Cited PapersHow to Report Low-Level Laser Therapy (LLLT)/Photomedicine Dose and Beam Parameters in Clinical and Laboratory Studies
Background: Dose and beam parameters are critical for successful laser, LED, and other light therapy treatments; however, in our experience, researchers frequently make critical errors and omissions when submitting papers for publication. Journals frequently publish studies with missing data, mathematical errors, and no reported verification of beam parameters. This makes reproducibility impossible, and further confounds an already complex subject. Objective: This article is intended to be a reference document for non-physicist researchers conducting low-level laser therapy (LLLT) laboratory studies and clinical trials to help them design and report the beam and dose aspects of their trials. Recommendations: It provides a checklist to help LLLT researchers understand and report all the necessary parameters for a repeatable scientific study. It includes the eight most important beam parameters to report, which are: wavelength, power, irradiation time, beam area at the skin or culture surface (this is not necessarily the same as the aperture size), pulse parameters, anatomical location, number of treatments, and interval between treatments. The three commonly used dose parameters are time, energy, and energy density. In addition, more thorough reporting would include coherence, application technique (contact, projection, scanning, pressure), beam profile, and spectral width, as these may also be considered important. Beam power often decreases as the device warms up and as the device ages; therefore, this should be checked routinely during an experiment/trial. Measurements of beam area and beam power require special instruments and trained technicians to operate them. Power measurements should be taken before, after, and at frequent intervals during research trials. Conclusion: Reviewers should insist that the minimum eight most important beam parameters are included, and authors should take care to measure and record these accurately before, during, and after an experiment or clinical trial.
- 14 October 2011
- Published by Springer Nature in Lasers in Medical Science
- Vol. 27 (6) , 1257-1258
Complications in comparing lasers and LED. Comment on Esper MA, Nicolau RA, Arisawa EA (2011) The effect of two phototherapy protocols on pain control in orthodontic procedure - a preliminary clinical study. Lasers Med Sci 26:657–663
- 14 October 2011
- Published by Springer Nature in Lasers in Medical Science
- Vol. 27 (6) , 1257-1258
Complications in comparing lasers and LED. Comment on Esper MA, Nicolau RA, Arisawa EA (2011) The effect of two phototherapy protocols on pain control in orthodontic procedure - a preliminary clinical study. Lasers Med Sci 26:657–663
- 10 February 2011
- Published by SPIE-Intl Soc Optical Eng
- Vol. 7887, 788703-788703-10
To what extent is coherence lost in tissue?
In a series of experiments we investigated the extent to which coherence is preserved in tissue. We investigated whether the decrease in coherence length is dependent upon the coherence length of the illuminating light and possibly also if the light is polarized. We compared highly coherent light from a HeNe laser, and less coherent light from a semiconductor laser, in scattering media such as raw ground beef. We studied the laser speckle contrast after passing through 1 - 2 cm of meat. The conclusion is that the laser light is still coherent enough to form laser speckles after passing through a 2 cm thickness of meat.
- 10 February 2011
- Published by SPIE-Intl Soc Optical Eng
- Vol. 7887, 788703-788703-10
To what extent is coherence lost in tissue?
In a series of experiments we investigated the extent to which coherence is preserved in tissue. We investigated whether the decrease in coherence length is dependent upon the coherence length of the illuminating light and possibly also if the light is polarized. We compared highly coherent light from a HeNe laser, and less coherent light from a semiconductor laser, in scattering media such as raw ground beef. We studied the laser speckle contrast after passing through 1 - 2 cm of meat. The conclusion is that the laser light is still coherent enough to form laser speckles after passing through a 2 cm thickness of meat.
- 22 February 2010
- Published by The Electrochemical Society in ECS Transactions
- Vol. 25 (33) , 1-10
Performance of a Printable Enzymatic Fuel Cell: Study on Mediated ThL Laccase Cathode
In this work the performance of a printed ThL laccase biocathode is studied utilizing different electrode substrates, compositions and enzyme activities. The results indicate that the performance of the manufactured biocathode can be optimized by selecting a suitable substrate material and increasing the enzyme and mediator loading. By varying the substrate material app. 40 % increase in the cell performance was achieved. In addition by adding ten times higher amount of enzyme and mediator increased the cell performance app. 20 %.
- 22 February 2010
- Published by The Electrochemical Society in ECS Transactions
- Vol. 25 (33) , 1-10
Performance of a Printable Enzymatic Fuel Cell: Study on Mediated ThL Laccase Cathode
In this work the performance of a printed ThL laccase biocathode is studied utilizing different electrode substrates, compositions and enzyme activities. The results indicate that the performance of the manufactured biocathode can be optimized by selecting a suitable substrate material and increasing the enzyme and mediator loading. By varying the substrate material app. 40 % increase in the cell performance was achieved. In addition by adding ten times higher amount of enzyme and mediator increased the cell performance app. 20 %.
- 12 February 2009
- Published by SPIE-Intl Soc Optical Eng
- Vol. 7165, 716507-716507-10
The importance of coherence in phototherapy
The importance of coherence in phototherapy has been questioned over the last two decades, with the arguments largely being based on; 1) Lasers are just convenient machines that produce radiation, 2) It is the radiation that produces the photobiological and/or photophysical effects and therapeutic gains, not the machines, and 3) Radiation must be absorbed to produce a chemical or physical change, which results in a biological response. Whilst these conclusions are, in essence, true, they neglect to account for the effects of laser speckle in vivo. In a proportion of individual laser speckles the intensity is higher than the surrounding environment, and the light is partially linearly polarized. This is important because the probability for a photon absorption event to occur largely depends on intensity and the photon absorption cross section of the molecule (which in turn is influenced by polarization and several other factors). In superficial tissue, where the photon flux is high (less absorption has taken place), it is easy to reach necessary power density thresholds without the benefits of laser speckle. However, in deep tissue where the photon flux is extremely low, the increased probability of photon absorption from individual laser speckles increases the probability of reaching the necessary power density thresholds. Because of the non-coherent nature of radiation from light/IR emitting diodes speckle does not occur in the tissue with LED therapy, which may explain why head-to-head comparisons between lasers and LEDs in deep tissue seem to be in favor of lasers, and super-pulsed lasers in particular.
- 12 February 2009
- Published by SPIE-Intl Soc Optical Eng
- Vol. 7165, 716507-716507-10
The importance of coherence in phototherapy
The importance of coherence in phototherapy has been questioned over the last two decades, with the arguments largely being based on; 1) Lasers are just convenient machines that produce radiation, 2) It is the radiation that produces the photobiological and/or photophysical effects and therapeutic gains, not the machines, and 3) Radiation must be absorbed to produce a chemical or physical change, which results in a biological response. Whilst these conclusions are, in essence, true, they neglect to account for the effects of laser speckle in vivo. In a proportion of individual laser speckles the intensity is higher than the surrounding environment, and the light is partially linearly polarized. This is important because the probability for a photon absorption event to occur largely depends on intensity and the photon absorption cross section of the molecule (which in turn is influenced by polarization and several other factors). In superficial tissue, where the photon flux is high (less absorption has taken place), it is easy to reach necessary power density thresholds without the benefits of laser speckle. However, in deep tissue where the photon flux is extremely low, the increased probability of photon absorption from individual laser speckles increases the probability of reaching the necessary power density thresholds. Because of the non-coherent nature of radiation from light/IR emitting diodes speckle does not occur in the tissue with LED therapy, which may explain why head-to-head comparisons between lasers and LEDs in deep tissue seem to be in favor of lasers, and super-pulsed lasers in particular.