Anis Saggaff
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Anis Saggaff has a total of 7 co-authors. Here are the top co-authors by number of shared publications:
- Kiagus Muhammad Aminuddin
Sriwijaya University, Civil Engineering Department, Faculty of Engineering, Indonesia
2 shared publications - Mahmood Md. Tahir
Institute for Smart Infrastructure and Innovative Construction (ISIIC), School of Civil Engineering, Faculty of Engineering, Universiti Teknologi Malaysia, Skudai 81310, Johor, Malaysia
2 shared publications - Arizu Sulaiman
Researcher, Geotechnical Engineering Research Group, Civil and Environmental Engineering Faculty, Institut Teknologi Bandung, Bandung - Indonesia
1 shared publication Muhammad Firdaus
Universitas PGRI Palembang, Faculty of Engineering, Civil Engineering Department, Indonesia
1 shared publication- Muhammad Firdaus
IKIP PGRI Pontianak
1 shared publication - Poi Ngian Shek
Universiti Teknologi Malaysia
1 shared publication
Latest Publications
- Open Access
- 30 September 2025
- Published by Warsaw University of Life Sciences - SGGW Press in Scientific Review Engineering and Environmental Sciences (SREES)
- Vol. 34 (3) , 305-323
Investigation of failure modes and load-deflection of cold-formed steel connections using sub-assemblage frame tests
Cold-formed steel (CFS) is a type of steel manufactured at ambient temperature using bending and rolling methods, enabling enhanced precision in shape and sizing. Its adaptability, resilience, and environmental sustainability render it very beneficial for building. Furthermore, its manufacturing method is more energy-efficient than conventional steel production and decreases emissions. Nonetheless, CFS has several limitations, including vulnerability to buckling owing to its slender profile. This research especially examines beam-column constructions with cold-formed steel connections. The paper discusses an experiment utilizing the sub-assemblage frame test method to improve the connection’s resistance by emphasizing haunched gusset plates, rectangular gusset plates, and a combination of rectangular gusset plates with the top-seat angle. The results demonstrated that the lateral-torsional buckling occurred on the beam. The connection’s bolt hole exhibited a bearing failure, and the flange cleat also experienced buckling. Graphs were employed to examine the load and deflection data, with maximum load and deflection values documented for each specimen. The result shows that the type of gusset plate, the height of the beam, and the utilization of flange cleats have an impact on the performance of the connection.
- 30 September 2025
- Published by Warsaw University of Life Sciences - SGGW Press in Scientific Review Engineering and Environmental Sciences (SREES)
- Vol. 34 (3) , 305-323
Open AccessInvestigation of failure modes and load-deflection of cold-formed steel connections using sub-assemblage frame tests
Cold-formed steel (CFS) is a type of steel manufactured at ambient temperature using bending and rolling methods, enabling enhanced precision in shape and sizing. Its adaptability, resilience, and environmental sustainability render it very beneficial for building. Furthermore, its manufacturing method is more energy-efficient than conventional steel production and decreases emissions. Nonetheless, CFS has several limitations, including vulnerability to buckling owing to its slender profile. This research especially examines beam-column constructions with cold-formed steel connections. The paper discusses an experiment utilizing the sub-assemblage frame test method to improve the connection’s resistance by emphasizing haunched gusset plates, rectangular gusset plates, and a combination of rectangular gusset plates with the top-seat angle. The results demonstrated that the lateral-torsional buckling occurred on the beam. The connection’s bolt hole exhibited a bearing failure, and the flange cleat also experienced buckling. Graphs were employed to examine the load and deflection data, with maximum load and deflection values documented for each specimen. The result shows that the type of gusset plate, the height of the beam, and the utilization of flange cleats have an impact on the performance of the connection.
- Open Access
- 31 December 2019
- Published by Bentham Science Publishers Ltd. in The Open Civil Engineering Journal
- Vol. 13 (1) , 210-217
Analytical and Experimental Investigation on Slip-in Gusset Plate Connection for Double C-channel Sections of Cold-formed Steel
Analytical and Experimental Investigation on Slip-in Gusset Plate Connection for Double C-channel Sections of Cold-formed Steel
- 31 December 2019
- Published by Bentham Science Publishers Ltd. in The Open Civil Engineering Journal
- Vol. 13 (1) , 210-217
Open AccessAnalytical and Experimental Investigation on Slip-in Gusset Plate Connection for Double C-channel Sections of Cold-formed Steel
Analytical and Experimental Investigation on Slip-in Gusset Plate Connection for Double C-channel Sections of Cold-formed Steel