Timothy L. Siu
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Timothy L. Siu has a total of 32 co-authors. Here are the top co-authors by number of shared publications:
- John W. Morley
University of New South Wales
6 shared publications Kainu Lin
Department of Clinical Medicine, Faculty of Medicine and Health Sciences, Macquarie University, NSW, Australia
5 shared publicationsElmira Najafi
Department of Clinical Medicine, Faculty of Medicine and Health Sciences, Macquarie University, NSW, Australia
3 shared publications- John William Fuller
Macquarie Neurosurgery, Macquarie University Hospital, Sydney, Australia
2 shared publications K. Nadana Chandran
2 shared publications- Kainu Lin
Department of Clinical Medicine, Faculty of Medicine and Health Sciences, Macquarie University, New South Wales, Australia
2 shared publications
Latest Publications
- 5 December 2025
- Published by Springer Nature in European Spine Journal
- p. 1-2
Answer to the letter to the editor of A. Abudayeh, et al. concerning “Lateral lumbar interbody fusion with lateral plating: techniques, feasibility and efficacy” by T. Siu, et al. (Eur Spine J [2025]; doi:10.1007/s00586-025-09411-w)
- 5 December 2025
- Published by Springer Nature in European Spine Journal
- p. 1-2
Answer to the letter to the editor of A. Abudayeh, et al. concerning “Lateral lumbar interbody fusion with lateral plating: techniques, feasibility and efficacy” by T. Siu, et al. (Eur Spine J [2025]; doi:10.1007/s00586-025-09411-w)
- Open Access
- 7 October 2025
- Published by Springer Nature in European Spine Journal
- p. 1-8
Lateral lumbar interbody fusion with lateral plating: techniques, feasibility and efficacy
Purpose: Standalone lateral lumbar interbody fusion (LLIF) enables single-position surgery and avoids the complications of posterior instrumentation though the lack of fixation may risk non-union and cage subsidence. Performing lateral plating following cage insertion may avert these untoward outcomes though the feasibility and efficacy of this approach, particularly with a four-hole plate, has been scarcely examined. The aim of this study is to review the techniques and appraise the performance of LLIF with lateral plating through analyzing a comprehensive set of clinical and radiographic case series data. Methods: A retrospective study was conducted on a series of 55 lateral plating LLIF patients with lumbar degenerative disease. Patients with significant deformity (Cobb angle > 20° and grade 2 spondylolisthesis) were excluded. Clinical outcomes were rated by patient reported outcome measures (PROMs). Non-union and cage subsidence were evaluated by computed tomography (CT) scans performed at 12 months post-surgery or beyond. Results: A four-hole plate was successfully implanted in 65 out of 77 operative levels. The remainder had a two-hole plate inserted. Postoperative psoas weakness occurred in eight patients (15%) and thigh or groin numbness in 10 (18%). All had complete or near complete resolution at the last follow-up. Of 68 operative levels with postoperative CT available, non-union was noted in eight (12%) and cage subsidence in 14 (21%), all low grade. Significant improvement in mean PROMs scores were demonstrated in patients with non-union or cage subsidence and none required reoperation. Multivariable logistic regression analyses revealed smoking (p = 0.002) and a lack of bicortical screw purchase (p = 0.038) were significant predictors for cage subsidence. Conclusion: A four-screw plating construct is a safe and feasible fixation technique for LLIF. The treatment paradigm is associated with significant improvement in PROMs and a favorable fusion rate. Low grade cage subsidence is a potential caveat though this may not translate into poorer clinical outcomes. Fixation with bicortical screws may help reduce the odds of cage subsidence.
- 7 October 2025
- Published by Springer Nature in European Spine Journal
- p. 1-8
Open AccessLateral lumbar interbody fusion with lateral plating: techniques, feasibility and efficacy
Purpose: Standalone lateral lumbar interbody fusion (LLIF) enables single-position surgery and avoids the complications of posterior instrumentation though the lack of fixation may risk non-union and cage subsidence. Performing lateral plating following cage insertion may avert these untoward outcomes though the feasibility and efficacy of this approach, particularly with a four-hole plate, has been scarcely examined. The aim of this study is to review the techniques and appraise the performance of LLIF with lateral plating through analyzing a comprehensive set of clinical and radiographic case series data. Methods: A retrospective study was conducted on a series of 55 lateral plating LLIF patients with lumbar degenerative disease. Patients with significant deformity (Cobb angle > 20° and grade 2 spondylolisthesis) were excluded. Clinical outcomes were rated by patient reported outcome measures (PROMs). Non-union and cage subsidence were evaluated by computed tomography (CT) scans performed at 12 months post-surgery or beyond. Results: A four-hole plate was successfully implanted in 65 out of 77 operative levels. The remainder had a two-hole plate inserted. Postoperative psoas weakness occurred in eight patients (15%) and thigh or groin numbness in 10 (18%). All had complete or near complete resolution at the last follow-up. Of 68 operative levels with postoperative CT available, non-union was noted in eight (12%) and cage subsidence in 14 (21%), all low grade. Significant improvement in mean PROMs scores were demonstrated in patients with non-union or cage subsidence and none required reoperation. Multivariable logistic regression analyses revealed smoking (p = 0.002) and a lack of bicortical screw purchase (p = 0.038) were significant predictors for cage subsidence. Conclusion: A four-screw plating construct is a safe and feasible fixation technique for LLIF. The treatment paradigm is associated with significant improvement in PROMs and a favorable fusion rate. Low grade cage subsidence is a potential caveat though this may not translate into poorer clinical outcomes. Fixation with bicortical screws may help reduce the odds of cage subsidence.
- 1 March 2021
- Published by Elsevier in World Neurosurgery
- Vol. 147, 234-235
In Reply to the Letter to the Editor Regarding “Lateral Lumbar Interbody Fusion at L4-5: A Morphometric Analysis of Psoas Anatomy and Cage Placement”
- 1 March 2021
- Published by Elsevier in World Neurosurgery
- Vol. 147, 234-235
In Reply to the Letter to the Editor Regarding “Lateral Lumbar Interbody Fusion at L4-5: A Morphometric Analysis of Psoas Anatomy and Cage Placement”
- 1 September 2020
- Published by Elsevier in World Neurosurgery
- Vol. 141, e691-e699
Lateral Lumbar Interbody Fusion at L4-5: A Morphometric Analysis of Psoas Anatomy and Cage Placement
- 1 September 2020
- Published by Elsevier in World Neurosurgery
- Vol. 141, e691-e699
Lateral Lumbar Interbody Fusion at L4-5: A Morphometric Analysis of Psoas Anatomy and Cage Placement
- 1 November 2018
- Published by Spandidos Publications in Oncology Letters
- Vol. 16 (5) , 6822-6830
Effects of FOXM1 inhibition and ionizing radiation on melanoma cells
Metastatic melanoma can be highly refractory to conventional radiotherapy and chemotherapy but combinatorial-targeted therapeutics are showing greater promise on improving treatment efficacy. Previous studies have shown that knockdown of Forkhead box M1 (FOXM1) can sensitize various tumor types to radiation-induced cell death. The effect of combining radiation with a small molecule FOXM1 inhibitor, Siomycin A, on growth, death and migration of a metastatic melanoma cell line (SK-MEL-28) that overexpresses this pleiotropic cell cycle regulator was investigated. Siomycin A (SIOA) was found to be a strong inducer of apoptosis, and inhibitor of proliferation and migration in a scratch wound assay in this cell line. Induction of apoptosis occurred at concentrations >1 mu M in association with reductions in the constitutive FOXM1 and anti-apoptotic B-cell lymphoma 2 protein levels found in these cells. Single doses of ionizing radiation (0-40 Gy) delivered by linear accelerator caused inhibition of growth and migration without significant induction of cell death. Pretreatment with SIOA did not increase the sensitivity of this melanoma cell line to radiation as observed in other tumor types. These data confirm that as a single agent, SIOA is an effective inducer of cell death and inhibitor of migration in metastatic melanoma cells expressing constitutive FOXM1. In combination with radiation, SIOA pre-treatment, however, may not be of added benefit.
- 1 November 2018
- Published by Spandidos Publications in Oncology Letters
- Vol. 16 (5) , 6822-6830
Effects of FOXM1 inhibition and ionizing radiation on melanoma cells
Metastatic melanoma can be highly refractory to conventional radiotherapy and chemotherapy but combinatorial-targeted therapeutics are showing greater promise on improving treatment efficacy. Previous studies have shown that knockdown of Forkhead box M1 (FOXM1) can sensitize various tumor types to radiation-induced cell death. The effect of combining radiation with a small molecule FOXM1 inhibitor, Siomycin A, on growth, death and migration of a metastatic melanoma cell line (SK-MEL-28) that overexpresses this pleiotropic cell cycle regulator was investigated. Siomycin A (SIOA) was found to be a strong inducer of apoptosis, and inhibitor of proliferation and migration in a scratch wound assay in this cell line. Induction of apoptosis occurred at concentrations >1 mu M in association with reductions in the constitutive FOXM1 and anti-apoptotic B-cell lymphoma 2 protein levels found in these cells. Single doses of ionizing radiation (0-40 Gy) delivered by linear accelerator caused inhibition of growth and migration without significant induction of cell death. Pretreatment with SIOA did not increase the sensitivity of this melanoma cell line to radiation as observed in other tumor types. These data confirm that as a single agent, SIOA is an effective inducer of cell death and inhibitor of migration in metastatic melanoma cells expressing constitutive FOXM1. In combination with radiation, SIOA pre-treatment, however, may not be of added benefit.
- 1 March 2018
- Published by Elsevier in World Neurosurgery
- Vol. 111, 1-5
Custom-Made Titanium 3-Dimensional Printed Interbody Cages for Treatment of Osteoporotic Fracture–Related Spinal Deformity
- 1 March 2018
- Published by Elsevier in World Neurosurgery
- Vol. 111, 1-5
Custom-Made Titanium 3-Dimensional Printed Interbody Cages for Treatment of Osteoporotic Fracture–Related Spinal Deformity
- 1 September 2017
- Published by Elsevier in Journal of Clinical Neuroscience
- Vol. 43, 178-184
Lateral lumbar interbody fusion at the lumbosacral junction
- 1 September 2017
- Published by Elsevier in Journal of Clinical Neuroscience
- Vol. 43, 178-184
Lateral lumbar interbody fusion at the lumbosacral junction
- 1 March 2017
- Published by Elsevier in Journal of Orthopaedics
- Vol. 14 (1) , 142-146
A radiographic analysis of cage positioning in lateral transpsoas lumbar interbody fusion
- 1 March 2017
- Published by Elsevier in Journal of Orthopaedics
- Vol. 14 (1) , 142-146
A radiographic analysis of cage positioning in lateral transpsoas lumbar interbody fusion
- 1 November 2016
- Published by Elsevier in Journal of Clinical Neuroscience
- Vol. 33, 129-133
Microscopic tubular discectomy for far lateral lumbar disc herniation
- 1 November 2016
- Published by Elsevier in Journal of Clinical Neuroscience
- Vol. 33, 129-133
Microscopic tubular discectomy for far lateral lumbar disc herniation
- Open Access
- 1 August 2016
- Published by Wiley in Orthopaedic Surgery
- Vol. 8 (3) , 301-308
Direct Tubular Lumbar Microdiscectomy for Far Lateral Disc Herniation: A Modified Approach
Objective: The concept of minimally invasive tubular discectomy is based on precise placement of the retractor over the surgical target to minimize collateral tissue trauma. For far lateral disc herniation, the junction between the pars and the transverse process has generally been adopted as the target for facilitating early nerve root exposure; however, this may limit access to the disc space and increase the risks of iatrogenic neuralgia. An alternative approach to help address these issues involving docking the retractor caudally directly over the disc space with the aid of a microscope is here proposed. The purpose of this study was to evaluate the safety and efficacy of such an approach.Methods: Nineteen patients in whom the modified approach was performed over a 35‐month period were identified. Direct access to the disc space was attained by directing the retractor against the lateral margin of the facet joint and following the inferior transverse process medially towards the foramen with minimal exposure of the nerve root. Clinical outcomes were assessed by the Oswestry Disability Index, visual analogue scale scores for leg and back pain, Short Form 36 physical functioning (SF36‐PF) and bodily pain (SF36‐BP) scores and sciatica bothersomeness and frequency indexes (SBI & SFI) and obtained from a prospective patient database. Follow‐up data in the first 6 months were compared with preoperative baseline data.Results: All procedures were successfully completed with the modified approach. Contained disc herniation without sequestrated fragments was found in all but four cases. No perioperative complications or reoperation were recorded and no postoperative dysesthesia was noted. Clinically significant reductions in mean Oswestry Disability Index (32; 95% CI, 21–43) and visual analogue scale scores for leg pain (38 mm; 95% CI, 23–54 mm) and back pain (35 mm; 95% CI, 21–48 mm) scores were noted in the first 6 months. Significant improvements in SF36‐PF (40; 95% CI, 30–51) and SF36‐BP (35; 95% CI, 26–43), SBI (9; 95% CI, 6–11) and SFI (11; 95% CI, 8–13) were also recorded.Conclusions: A modified direct tubular approach is safe and effective for treating far lateral lumbar disc herniation. Our early results suggest that this approach helps safeguard adequate decompression and reduce the risk of postoperative dysesthesia.
- 1 August 2016
- Published by Wiley in Orthopaedic Surgery
- Vol. 8 (3) , 301-308
Open AccessDirect Tubular Lumbar Microdiscectomy for Far Lateral Disc Herniation: A Modified Approach
Objective: The concept of minimally invasive tubular discectomy is based on precise placement of the retractor over the surgical target to minimize collateral tissue trauma. For far lateral disc herniation, the junction between the pars and the transverse process has generally been adopted as the target for facilitating early nerve root exposure; however, this may limit access to the disc space and increase the risks of iatrogenic neuralgia. An alternative approach to help address these issues involving docking the retractor caudally directly over the disc space with the aid of a microscope is here proposed. The purpose of this study was to evaluate the safety and efficacy of such an approach.Methods: Nineteen patients in whom the modified approach was performed over a 35‐month period were identified. Direct access to the disc space was attained by directing the retractor against the lateral margin of the facet joint and following the inferior transverse process medially towards the foramen with minimal exposure of the nerve root. Clinical outcomes were assessed by the Oswestry Disability Index, visual analogue scale scores for leg and back pain, Short Form 36 physical functioning (SF36‐PF) and bodily pain (SF36‐BP) scores and sciatica bothersomeness and frequency indexes (SBI & SFI) and obtained from a prospective patient database. Follow‐up data in the first 6 months were compared with preoperative baseline data.Results: All procedures were successfully completed with the modified approach. Contained disc herniation without sequestrated fragments was found in all but four cases. No perioperative complications or reoperation were recorded and no postoperative dysesthesia was noted. Clinically significant reductions in mean Oswestry Disability Index (32; 95% CI, 21–43) and visual analogue scale scores for leg pain (38 mm; 95% CI, 23–54 mm) and back pain (35 mm; 95% CI, 21–48 mm) scores were noted in the first 6 months. Significant improvements in SF36‐PF (40; 95% CI, 30–51) and SF36‐BP (35; 95% CI, 26–43), SBI (9; 95% CI, 6–11) and SFI (11; 95% CI, 8–13) were also recorded.Conclusions: A modified direct tubular approach is safe and effective for treating far lateral lumbar disc herniation. Our early results suggest that this approach helps safeguard adequate decompression and reduce the risk of postoperative dysesthesia.