Sebastien Dubos
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Research Interests
Sebastien Dubos has a total of 187 co-authors. Here are the top co-authors by number of shared publications:
- Gianluca Cavoto
Sapienza Università di Roma
12 shared publications A. Stocchi
11 shared publicationsD. Breton
11 shared publicationsF. Addesa
11 shared publicationsF. Iacoangeli
11 shared publicationsR. Rossi
11 shared publications
Latest Publications
- 1 January 2019
- Published by Elsevier in Nuclear Instruments and Methods in Physics Research Section B: Beam Interactions with Materials and Atoms
- Vol. 438, 38-41
Dechanneling of high energy particles in a long bent crystal
- 1 January 2019
- Published by Elsevier in Nuclear Instruments and Methods in Physics Research Section B: Beam Interactions with Materials and Atoms
- Vol. 438, 38-41
Dechanneling of high energy particles in a long bent crystal
- Open Access
- 1 December 2018
- Published by Elsevier in Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment
- Vol. 910, 15-21
Characterisation of the fused silica surface quality with a -source- 1 December 2018
- Published by Elsevier in Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment
- Vol. 910, 15-21
Open AccessCharacterisation of the fused silica surface quality with a -source - Open Access
- 18 June 2018
- Published by Springer Nature in The European Physical Journal C
- Vol. 78 (6) , 1-8
Study of inelastic nuclear interactions of 400 GeV/c protons in bent silicon crystals for beam steering purposes
Inelastic nuclear interaction probability of 400 GeV/c protons interacting with bent silicon crystals was investigated, in particular for both types of cry
- 18 June 2018
- Published by Springer Nature in The European Physical Journal C
- Vol. 78 (6) , 1-8
Open AccessStudy of inelastic nuclear interactions of 400 GeV/c protons in bent silicon crystals for beam steering purposes
Inelastic nuclear interaction probability of 400 GeV/c protons interacting with bent silicon crystals was investigated, in particular for both types of cry
- 8 June 2018
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Nuclear Science
- Vol. 65 (7) , 1408-1415
D2R1: A 2-D X-Ray Detector for CdTe-Based Fine Pitch and High-Energy Resolution Imaging Spectroscopy
This work describes a 16 × 16 pixels CdTe based X-ray detector named D2R1 (Dimension 2 Revision 1) with a pixel size of 300 μm × 300 μm. An Application Specific Integrated Circuit (ASIC) is interconnected to a CdTe detector by means of an Indium Gold Stud Bonding process. This ASIC has a mean Equivalent Noise Charge (ENC) of 29 el.rms (at 0 pF). The combination of a low capacitance interconnection and low dark current detector (0.5 pA) with an optimized ASIC results in a spectral resolution of 584 eV FWHM at 60 keV, an energy threshold of 2 keV with a dynamic range of 250 keV. A filtering stage made of a Multi Correlated Double Sampling (MCDS) allows the system to measure X-ray photons at a frequency of 10 kcounts/s typically suited for low photon flux less than 3000 photons.cm-2.s-1. The energy range, resolution and timing capability of D2R1 can suite a variety of different applications such as X-ray astrophysics, nuclear safety, or medical applications.
- 8 June 2018
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Nuclear Science
- Vol. 65 (7) , 1408-1415
D2R1: A 2-D X-Ray Detector for CdTe-Based Fine Pitch and High-Energy Resolution Imaging Spectroscopy
This work describes a 16 × 16 pixels CdTe based X-ray detector named D2R1 (Dimension 2 Revision 1) with a pixel size of 300 μm × 300 μm. An Application Specific Integrated Circuit (ASIC) is interconnected to a CdTe detector by means of an Indium Gold Stud Bonding process. This ASIC has a mean Equivalent Noise Charge (ENC) of 29 el.rms (at 0 pF). The combination of a low capacitance interconnection and low dark current detector (0.5 pA) with an optimized ASIC results in a spectral resolution of 584 eV FWHM at 60 keV, an energy threshold of 2 keV with a dynamic range of 250 keV. A filtering stage made of a Multi Correlated Double Sampling (MCDS) allows the system to measure X-ray photons at a frequency of 10 kcounts/s typically suited for low photon flux less than 3000 photons.cm-2.s-1. The energy range, resolution and timing capability of D2R1 can suite a variety of different applications such as X-ray astrophysics, nuclear safety, or medical applications.
- Open Access
- 18 January 2018
- Published by American Physical Society (APS) in Physical Review Accelerators and Beams
- Vol. 21 (1) , 014702
Comprehensive study of beam focusing by crystal devices
This paper is devoted to an experimental study of focusing and defocusing positively charged particle beams with the help of specially bent single crystals. Four crystals have been fabricated for this purpose. The studies have been performed at the CERN SPS in proton and pion beams. The results of measurements of beam envelopes are presented. The rms size of the horizontal profile at the focus was 5–8 times smaller than at the exit of the crystals. The measured focal lengths were 4–21 m. The results of measurements are in good agreement with calculations. Possible applications of focusing crystals in present and future high energy accelerators are discussed.- 18 January 2018
- Published by American Physical Society (APS) in Physical Review Accelerators and Beams
- Vol. 21 (1) , 014702
Open AccessComprehensive study of beam focusing by crystal devices
This paper is devoted to an experimental study of focusing and defocusing positively charged particle beams with the help of specially bent single crystals. Four crystals have been fabricated for this purpose. The studies have been performed at the CERN SPS in proton and pion beams. The results of measurements of beam envelopes are presented. The rms size of the horizontal profile at the focus was 5–8 times smaller than at the exit of the crystals. The measured focal lengths were 4–21 m. The results of measurements are in good agreement with calculations. Possible applications of focusing crystals in present and future high energy accelerators are discussed. - 1 January 2018
- Published by Elsevier in Nuclear Instruments and Methods in Physics Research Section B: Beam Interactions with Materials and Atoms
- Vol. 414, 104-106
Focusing of a particle beam by a crystal device with a short focal length
- 1 January 2018
- Published by Elsevier in Nuclear Instruments and Methods in Physics Research Section B: Beam Interactions with Materials and Atoms
- Vol. 414, 104-106
Focusing of a particle beam by a crystal device with a short focal length
- 1 October 2017
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-3
Characterization of the quartz surface quality with β-source
We present a method for characterizing the quality of the Cherenkov quartz radiator. It is based on the scanning with 90 Sr radioactive source (standard deviation is 1.17 mm) of the radiator surface and measurements of the Cherenkov light rate and amplitude, detected by the PMT attached to the quartz bars. This experimental data have been compared with a Monte-Carlo simulation which repeats the same experimental configuration. This method gives an upper estimate of the radiator parameters which are related to two different quantities: (1) probability of the total internal reflection; (2) ineffective area in the corner of the quartz bar.
- 1 October 2017
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-3
Characterization of the quartz surface quality with β-source
We present a method for characterizing the quality of the Cherenkov quartz radiator. It is based on the scanning with 90 Sr radioactive source (standard deviation is 1.17 mm) of the radiator surface and measurements of the Cherenkov light rate and amplitude, detected by the PMT attached to the quartz bars. This experimental data have been compared with a Monte-Carlo simulation which repeats the same experimental configuration. This method gives an upper estimate of the radiator parameters which are related to two different quantities: (1) probability of the total internal reflection; (2) ineffective area in the corner of the quartz bar.
- Open Access
- 1 April 2017
- Published by IOP Publishing in Journal of Instrumentation
- Vol. 12 (04) , P04029
The CpFM, an in-vacuum Cherenkov beam monitor for UA9 at SPS
The use of bent crystals for beam manipulation in particle accelerators is a well-assessed concept rapidly evolving into practical application. The experiments of the UA9 collaboration at the CERN-SPS have played a key role for a quantitative understanding of channeling and volume reflection mechanisms. Investigation of the channeling process close to a circulating beam ideally requires in vacuum detectors resolving the single particle, which should be located inside the vacuum pipe itself. Cherenkov radiators are potential candidates for such functionality due the reduced electro-magnetic interaction of the radiator material with the circulating charges and their compatibility with vacuum requirements in the beam pipe. For this purpose, we developed a device called Cherenkov detector for proton Flux Measurement (CpFM) that aims at counting the number of deflected protons of the beam halo surrounding the circulating beam with an accuracy of 15%. After a detailed description of the detection chain and its simulation, we present results of beam tests of different configurations, the calibration of the final device and the results of its first operation in the SPS.
- 1 April 2017
- Published by IOP Publishing in Journal of Instrumentation
- Vol. 12 (04) , P04029
Open AccessThe CpFM, an in-vacuum Cherenkov beam monitor for UA9 at SPS
The use of bent crystals for beam manipulation in particle accelerators is a well-assessed concept rapidly evolving into practical application. The experiments of the UA9 collaboration at the CERN-SPS have played a key role for a quantitative understanding of channeling and volume reflection mechanisms. Investigation of the channeling process close to a circulating beam ideally requires in vacuum detectors resolving the single particle, which should be located inside the vacuum pipe itself. Cherenkov radiators are potential candidates for such functionality due the reduced electro-magnetic interaction of the radiator material with the circulating charges and their compatibility with vacuum requirements in the beam pipe. For this purpose, we developed a device called Cherenkov detector for proton Flux Measurement (CpFM) that aims at counting the number of deflected protons of the beam halo surrounding the circulating beam with an accuracy of 15%. After a detailed description of the detection chain and its simulation, we present results of beam tests of different configurations, the calibration of the final device and the results of its first operation in the SPS.