Christian Heiliger
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Christian Heiliger has a total of 122 co-authors. Here are the top co-authors by number of shared publications:
Jens Werner
Department of General, Visceral and Transplant Surgery, Ludwig-Maximilians-University Hospital Munich, Munich, Germany
8 shared publications- Alexander Frank
Klinikum der LMU München
5 shared publications - Dorian Andrade
Department of General, Visceral and Transplantation Surgery, Ludwig-Maximilians-University (LMU), 80539 Munich, Germany
5 shared publications - Konrad Karcz
Department of General, Visceral, and Transplantation Surgery, Hospital of the LMU Munich, Ludwig-Maximilians-Universität (LMU), Munich, Germany
5 shared publications - Alessandra Deodati
Department of General, Visceral, and Transplantation Surgery, Hospital of the LMU Munich, Ludwig-Maximilians-Universität (LMU), Munich, Germany
3 shared publications - Alexander Winkler
Department of General, Visceral, and Transplantation Surgery, Hospital of the LMU Munich, Ludwig-Maximilians-Universität (LMU), Munich, Germany
3 shared publications
Latest Publications
- Open Access
- 17 November 2026
- Published by Elsevier in European Journal of Surgical Oncology
- Vol. 53 (2)
Multicentre assessment of interactive 3D holograms for enhanced preoperative planning for colorectal liver metastasis resection
- 17 November 2026
- Published by Elsevier in European Journal of Surgical Oncology
- Vol. 53 (2)
Open AccessMulticentre assessment of interactive 3D holograms for enhanced preoperative planning for colorectal liver metastasis resection
- Open Access
- 25 June 2025
- Published by Elsevier in Medical Image Analysis
- Vol. 105, 103687
Beyond role-based surgical domain modeling: Generalizable re-identification in the operating room
- 25 June 2025
- Published by Elsevier in Medical Image Analysis
- Vol. 105, 103687
Open AccessBeyond role-based surgical domain modeling: Generalizable re-identification in the operating room
- Open Access
- 7 April 2025
- Published by Springer Nature in Scientific Reports
- Vol. 15 (1) , 1-10
Validation of body composition parameters extracted via deep learning-based segmentation from routine computed tomographies
Sarcopenia and body composition metrics are strongly associated with patient outcomes. In this study, we developed and validated a flexible, open-access pipeline integrating available deep learning-based segmentation models with pre- and postprocessing steps to extract body composition measures from routine computed tomography (CT) scans. In 337 surgical oncology patients, total skeletal muscle tissue (SMtotal), psoas muscle tissue (SMpsoas), visceral adipose tissue (VAT), and subcutaneous adipose tissue (SAT) were quantified both manually and using the pipeline. Automated and manual measurements showed strong correlations (SMpsoas: r = 0.776, VAT: r = 0.993, SAT: r = 0.984; all P < 0.001). Measurement discrepancies primarily resulted from segmentation errors, anatomical anomalies or image irregularities. SMpsoas measurements showed substantial variability depending on slice selection, whereas SMtotal, averaged across all L3 levels, provided greater measurement stability. Overall, SMtotal performed comparably to SMpsoas in predicting overall survival (OS). In summary, body composition measures derived from the pipeline strongly correlated with manual measurements and were prognostic for OS. The increased stability of SMtotal across vertebral levels suggests it may serve as a more reliable alternative to psoas-based assessments. Future studies should address the identified areas of improvement to enhance the accuracy of automated segmentation models.
- 7 April 2025
- Published by Springer Nature in Scientific Reports
- Vol. 15 (1) , 1-10
Open AccessValidation of body composition parameters extracted via deep learning-based segmentation from routine computed tomographies
Sarcopenia and body composition metrics are strongly associated with patient outcomes. In this study, we developed and validated a flexible, open-access pipeline integrating available deep learning-based segmentation models with pre- and postprocessing steps to extract body composition measures from routine computed tomography (CT) scans. In 337 surgical oncology patients, total skeletal muscle tissue (SMtotal), psoas muscle tissue (SMpsoas), visceral adipose tissue (VAT), and subcutaneous adipose tissue (SAT) were quantified both manually and using the pipeline. Automated and manual measurements showed strong correlations (SMpsoas: r = 0.776, VAT: r = 0.993, SAT: r = 0.984; all P < 0.001). Measurement discrepancies primarily resulted from segmentation errors, anatomical anomalies or image irregularities. SMpsoas measurements showed substantial variability depending on slice selection, whereas SMtotal, averaged across all L3 levels, provided greater measurement stability. Overall, SMtotal performed comparably to SMpsoas in predicting overall survival (OS). In summary, body composition measures derived from the pipeline strongly correlated with manual measurements and were prognostic for OS. The increased stability of SMtotal across vertebral levels suggests it may serve as a more reliable alternative to psoas-based assessments. Future studies should address the identified areas of improvement to enhance the accuracy of automated segmentation models.
- 9 June 2023
- Published by Taylor & Francis in Minimally Invasive Therapy & Allied Technologies
- Vol. 32 (4) , 190-198
AR visualizations in laparoscopy: surgeon preferences and depth assessment of vascular anatomy
Introduction: This study compares five augmented reality (AR) vasculature visualization techniques in a mixed-reality laparoscopy simulator with 50 medical professionals and analyzes their impact on the surgeon. Material and methods: The different visualization techniques' abilities to convey depth were measured using the participant's accuracy in an objective depth sorting task. Demographic data and subjective measures, such as the preference of each AR visualization technique and potential application areas, were collected with questionnaires. Results: Despite measuring differences in objective measurements across the visualization techniques, they were not statistically significant. In the subjective measures, however, 55% of the participants rated visualization technique II, 'Opaque with single-color Fresnel highlights', as their favorite. Participants felt that AR could be useful for various surgeries, especially complex surgeries (100%). Almost all participants agreed that AR could potentially improve surgical parameters, such as patient safety (88%), complication rate (84%), and identifying risk structures (96%). Conclusions: More studies are needed on the effect of different visualizations on task performance, as well as more sophisticated and effective visualization techniques for the operating room. With the findings of this study, we encourage the development of new study setups to advance surgical AR.
- 9 June 2023
- Published by Taylor & Francis in Minimally Invasive Therapy & Allied Technologies
- Vol. 32 (4) , 190-198
AR visualizations in laparoscopy: surgeon preferences and depth assessment of vascular anatomy
Introduction: This study compares five augmented reality (AR) vasculature visualization techniques in a mixed-reality laparoscopy simulator with 50 medical professionals and analyzes their impact on the surgeon. Material and methods: The different visualization techniques' abilities to convey depth were measured using the participant's accuracy in an objective depth sorting task. Demographic data and subjective measures, such as the preference of each AR visualization technique and potential application areas, were collected with questionnaires. Results: Despite measuring differences in objective measurements across the visualization techniques, they were not statistically significant. In the subjective measures, however, 55% of the participants rated visualization technique II, 'Opaque with single-color Fresnel highlights', as their favorite. Participants felt that AR could be useful for various surgeries, especially complex surgeries (100%). Almost all participants agreed that AR could potentially improve surgical parameters, such as patient safety (88%), complication rate (84%), and identifying risk structures (96%). Conclusions: More studies are needed on the effect of different visualizations on task performance, as well as more sophisticated and effective visualization techniques for the operating room. With the findings of this study, we encourage the development of new study setups to advance surgical AR.
- Open Access
- 28 March 2023
- Published by Springer Nature in Surgical Endoscopy
- Vol. 37 (7) , 5274-5284
Tracking and evaluating motion skills in laparoscopy with inertial sensors
Background: Analysis of surgical instrument motion is applicable in surgical skill assessment and monitoring of the learning progress in laparoscopy. Current commercial instrument tracking technology (optical or electromagnetic) has specific limitations and is expensive. Therefore, in this study, we apply inexpensive, off-the-shelf inertial sensors to track laparoscopic instruments in a training scenario. Methods: We calibrated two laparoscopic instruments to the inertial sensor and investigated its accuracy on a 3D-printed phantom. In a user study during a one-week laparoscopy training course with medical students and physicians, we then documented and compared the training effect in laparoscopic tasks on a commercially available laparoscopy trainer (Laparo Analytic, Laparo Medical Simulators, Wilcza, Poland) and the newly developed tracking setup. Results: Eighteen participants (twelve medical students and six physicians) participated in the study. The student subgroup showed significantly poorer results for the count of swings (CS) and count of rotations (CR) at the beginning of the training compared to the physician subgroup (p = 0.012 and p = 0.042). After training, the student subgroup showed significant improvements in the rotatory angle sum, CS, and CR (p = 0.025, p = 0.004 and p = 0.024). After training, there were no significant differences between medical students and physicians. There was a strong correlation between the measured learning success (LS) from the data of our inertial measurement unit system (LSIMU) and the Laparo Analytic (LSLap) (Pearson’s r = 0.79). Conclusion: In the current study, we observed a good and valid performance of inertial measurement units as a possible tool for instrument tracking and surgical skill assessment. Moreover, we conclude that the sensor can meaningfully examine the learning progress of medical students in an ex-vivo setting.
- 28 March 2023
- Published by Springer Nature in Surgical Endoscopy
- Vol. 37 (7) , 5274-5284
Open AccessTracking and evaluating motion skills in laparoscopy with inertial sensors
Background: Analysis of surgical instrument motion is applicable in surgical skill assessment and monitoring of the learning progress in laparoscopy. Current commercial instrument tracking technology (optical or electromagnetic) has specific limitations and is expensive. Therefore, in this study, we apply inexpensive, off-the-shelf inertial sensors to track laparoscopic instruments in a training scenario. Methods: We calibrated two laparoscopic instruments to the inertial sensor and investigated its accuracy on a 3D-printed phantom. In a user study during a one-week laparoscopy training course with medical students and physicians, we then documented and compared the training effect in laparoscopic tasks on a commercially available laparoscopy trainer (Laparo Analytic, Laparo Medical Simulators, Wilcza, Poland) and the newly developed tracking setup. Results: Eighteen participants (twelve medical students and six physicians) participated in the study. The student subgroup showed significantly poorer results for the count of swings (CS) and count of rotations (CR) at the beginning of the training compared to the physician subgroup (p = 0.012 and p = 0.042). After training, the student subgroup showed significant improvements in the rotatory angle sum, CS, and CR (p = 0.025, p = 0.004 and p = 0.024). After training, there were no significant differences between medical students and physicians. There was a strong correlation between the measured learning success (LS) from the data of our inertial measurement unit system (LSIMU) and the Laparo Analytic (LSLap) (Pearson’s r = 0.79). Conclusion: In the current study, we observed a good and valid performance of inertial measurement units as a possible tool for instrument tracking and surgical skill assessment. Moreover, we conclude that the sensor can meaningfully examine the learning progress of medical students in an ex-vivo setting.
- Open Access
- 22 December 2022
- Published by Springer Nature in International Journal of Computer Assisted Radiology and Surgery
- Vol. 18 (8) , 1345-1354
Phantom study on surgical performance in augmented reality laparoscopy
Purpose: Only a few studies have evaluated Augmented Reality (AR) in in vivo simulations compared to traditional laparoscopy; further research is especially needed regarding the most effective AR visualization technique. This pilot study aims to determine, under controlled conditions on a 3D-printed phantom, whether an AR laparoscope improves surgical outcomes over conventional laparoscopy without augmentation.Methods: We selected six surgical residents at a similar level of training and had them perform a laparoscopic task. The participants repeated the experiment three times, using different 3D phantoms and visualizations:Floating AR,Occlusion AR, and without any AR visualization (Control). Surgical performance was determined using objective measurements. Subjective measures, such as task load and potential application areas, were collected with questionnaires.Results: Differences in operative time, total touching time, and SurgTLX scores showed no statistical significance ( $$p>0.05$$ ). However, when assessing the invasiveness of the simulated intervention, the comparison revealed a statistically significant difference ( $$p=0.009$$ ). Participants felt AR could be useful for various surgeries, especially for liver, sigmoid, and pancreatic resections (100%). Almost all participants agreed that AR could potentially lead to improved surgical parameters, such as operative time (83%), complication rate (83%), and identifying risk structures (83%).Conclusion: According to our results, AR may have great potential in visceral surgery and based on the objective measures of the study, may improve surgeons' performance in terms of an atraumatic approach. In this pilot study, participants consistently took more time to complete the task, had more contact with the vascular tree, were significantly more invasive, and scored higher on the SurgTLX survey than with AR.- 22 December 2022
- Published by Springer Nature in International Journal of Computer Assisted Radiology and Surgery
- Vol. 18 (8) , 1345-1354
Open AccessPhantom study on surgical performance in augmented reality laparoscopy
Purpose: Only a few studies have evaluated Augmented Reality (AR) in in vivo simulations compared to traditional laparoscopy; further research is especially needed regarding the most effective AR visualization technique. This pilot study aims to determine, under controlled conditions on a 3D-printed phantom, whether an AR laparoscope improves surgical outcomes over conventional laparoscopy without augmentation.Methods: We selected six surgical residents at a similar level of training and had them perform a laparoscopic task. The participants repeated the experiment three times, using different 3D phantoms and visualizations:Floating AR,Occlusion AR, and without any AR visualization (Control). Surgical performance was determined using objective measurements. Subjective measures, such as task load and potential application areas, were collected with questionnaires.Results: Differences in operative time, total touching time, and SurgTLX scores showed no statistical significance ( $$p>0.05$$ ). However, when assessing the invasiveness of the simulated intervention, the comparison revealed a statistically significant difference ( $$p=0.009$$ ). Participants felt AR could be useful for various surgeries, especially for liver, sigmoid, and pancreatic resections (100%). Almost all participants agreed that AR could potentially lead to improved surgical parameters, such as operative time (83%), complication rate (83%), and identifying risk structures (83%).Conclusion: According to our results, AR may have great potential in visceral surgery and based on the objective measures of the study, may improve surgeons' performance in terms of an atraumatic approach. In this pilot study, participants consistently took more time to complete the task, had more contact with the vascular tree, were significantly more invasive, and scored higher on the SurgTLX survey than with AR. - 15 June 2022
- Published by Georg Thieme Verlag KG in Zentralblatt fur Chirurgie
- Vol. 147 (03) , 215-219
Bedeutung der künstlichen Intelligenz für die computergestützte Chirurgie
Computer sind aus dem privaten wie auch aus dem medizinischen Alltag nicht mehr wegzudenken. Gerade die in den letzten Jahrzehnten aufgekommenen immer größeren Rechenkapazitäten ermöglichen ein Forschungsfeld, was in der Mitte des letzten Jahrhunderts nur Theorie war: künstliche Intelligenz. Diese mal mehr und mal weniger offensichtliche Technologie ist im Alltag bereits weit verbreitet und hält auch immer mehr Einzug in die Medizin. Dabei sind die Einsatzmöglichkeiten mannigfaltig: von Risikostratifizierung über Kommunikation bis zu autonomen Robotern. Bisher konnte in vielen Studien gezeigt werden, dass künstliche Intelligenz Vorteile hat, vor allem in der Analyse und Interpretation großer Datenmengen. Diese Daten sind die Grundlage dieser Wissenschaft. Allerdings sollte man auch nicht außer Acht lassen, dass mit der Betrachtung computer- und algorithmusgestützter Aussagen ethische und medikolegale Fragen einhergehen, welche abschließend noch nicht beantwortet sind. Alles in allem hat die künstliche Intelligenz innerhalb der computergestützten Chirurgie und Medizin im Allgemeinen das Potenzial, diese sicherer und zielgerichteter zu machen. Article published online: 15 June 2022 © 2022. Thieme. All rights reserved. Georg Thieme Verlag KG Rüdigerstraße 14, 70469 Stuttgart, Germany
- 15 June 2022
- Published by Georg Thieme Verlag KG in Zentralblatt fur Chirurgie
- Vol. 147 (03) , 215-219
Bedeutung der künstlichen Intelligenz für die computergestützte Chirurgie
Computer sind aus dem privaten wie auch aus dem medizinischen Alltag nicht mehr wegzudenken. Gerade die in den letzten Jahrzehnten aufgekommenen immer größeren Rechenkapazitäten ermöglichen ein Forschungsfeld, was in der Mitte des letzten Jahrhunderts nur Theorie war: künstliche Intelligenz. Diese mal mehr und mal weniger offensichtliche Technologie ist im Alltag bereits weit verbreitet und hält auch immer mehr Einzug in die Medizin. Dabei sind die Einsatzmöglichkeiten mannigfaltig: von Risikostratifizierung über Kommunikation bis zu autonomen Robotern. Bisher konnte in vielen Studien gezeigt werden, dass künstliche Intelligenz Vorteile hat, vor allem in der Analyse und Interpretation großer Datenmengen. Diese Daten sind die Grundlage dieser Wissenschaft. Allerdings sollte man auch nicht außer Acht lassen, dass mit der Betrachtung computer- und algorithmusgestützter Aussagen ethische und medikolegale Fragen einhergehen, welche abschließend noch nicht beantwortet sind. Alles in allem hat die künstliche Intelligenz innerhalb der computergestützten Chirurgie und Medizin im Allgemeinen das Potenzial, diese sicherer und zielgerichteter zu machen. Article published online: 15 June 2022 © 2022. Thieme. All rights reserved. Georg Thieme Verlag KG Rüdigerstraße 14, 70469 Stuttgart, Germany
- Open Access
- 1 December 2020
- Published by Springer Nature in Surgical Endoscopy
- Vol. 35 (12) , 6687-6695
Endoscopic vacuum therapy for in- and outpatient treatment of colorectal defects
Background: Evidence for endoscopic vacuum therapy (EVT) for colorectal defects is still based on small patient series from various institutions, employing different treatment algorithms and methods. As EVT was invented at our institution 20 years ago, the aim was to report the efficacy and safety of EVT for colorectal defects as well as to analyze factors associated with efficacy, therapy duration, and outpatient treatment. Methods: Cohort study with analysis of prospectively collected data of patients receiving EVT for colorectal defects at a tertiary referral center in Germany (n = 281). Results: The majority of patients had malignant disease (83%) and an American Society of Anesthesiologists classification of III/IV (81%). Most frequent indications for EVT were anastomotic leakage after sigmoid or rectal resection (67%) followed by rectal stump leakage (20%). EVT was successful in 256 out of 281 patients (91%). EVT following multi-visceral resection (P = 0.037) and recent surgical revision after primary surgery (P = 0.009) were risk factors for EVT failure. EVT-associated adverse events occurred in 27 patients (10%). Median treatment duration was 25 days. Previous chemo-radiation (P = 0.006) was associated with a significant longer duration of EVT. Outpatient treatment was conducted in 49% of patients with a median hospital stay reduction of 15 days and 98% treatment success. Younger patient age (P = 0.044) was associated with the possibility of outpatient treatment. Restoration of intestinal continuity was achieved in 60% of patients where technically possible with a 12-month rate of 52%. Conclusions: In patients with colorectal defects, EVT appears to be a safe and effective, minimally invasive option for in- and outpatient treatment.
- 1 December 2020
- Published by Springer Nature in Surgical Endoscopy
- Vol. 35 (12) , 6687-6695
Open AccessEndoscopic vacuum therapy for in- and outpatient treatment of colorectal defects
Background: Evidence for endoscopic vacuum therapy (EVT) for colorectal defects is still based on small patient series from various institutions, employing different treatment algorithms and methods. As EVT was invented at our institution 20 years ago, the aim was to report the efficacy and safety of EVT for colorectal defects as well as to analyze factors associated with efficacy, therapy duration, and outpatient treatment. Methods: Cohort study with analysis of prospectively collected data of patients receiving EVT for colorectal defects at a tertiary referral center in Germany (n = 281). Results: The majority of patients had malignant disease (83%) and an American Society of Anesthesiologists classification of III/IV (81%). Most frequent indications for EVT were anastomotic leakage after sigmoid or rectal resection (67%) followed by rectal stump leakage (20%). EVT was successful in 256 out of 281 patients (91%). EVT following multi-visceral resection (P = 0.037) and recent surgical revision after primary surgery (P = 0.009) were risk factors for EVT failure. EVT-associated adverse events occurred in 27 patients (10%). Median treatment duration was 25 days. Previous chemo-radiation (P = 0.006) was associated with a significant longer duration of EVT. Outpatient treatment was conducted in 49% of patients with a median hospital stay reduction of 15 days and 98% treatment success. Younger patient age (P = 0.044) was associated with the possibility of outpatient treatment. Restoration of intestinal continuity was achieved in 60% of patients where technically possible with a 12-month rate of 52%. Conclusions: In patients with colorectal defects, EVT appears to be a safe and effective, minimally invasive option for in- and outpatient treatment.
- 2 November 2018
- Published by Taylor & Francis in Minimally Invasive Therapy & Allied Technologies
- Vol. 28 (6) , 321-325
Intraarterial indocyanine green (ICG) fluorescence augmentation by marking embryonal resection areas in colorectal surgery: a feasibility study in a porcine model
Aim: In this pilot animal study we examined whether it is possible to visualize the embryonal resection layers by using intraarterial indocyanine green (ICG) staining when performing total mesorectal excision (TME) for carcinoma of the rectum. Material and methods: We injected ICG into the inferior mesenteric artery (AMI) of four swines to see whether the watershed area of the arterial supply zone can be sufficiently visualized by fluorescence imaging in order to mark the right dissection area along the fascia parietalis before and during resection. Results: We observed a fluorescence signal in all the supplied areas of AMI but not in other parts of the abdominal cavity or other organs. Additionally, the mesorectum also showed a sharp border between colored and non-colored tissue. Conclusion: In this study we present that resection borders may be determined before resection based on ICG-perfusion and we showed that intraoperative exclusive coloring of the rectum including the mesorectum is possible. Visualizing resection borders based on ICG-perfusion before settling the first cut may be a new approach in oncological surgery.
- 2 November 2018
- Published by Taylor & Francis in Minimally Invasive Therapy & Allied Technologies
- Vol. 28 (6) , 321-325
Intraarterial indocyanine green (ICG) fluorescence augmentation by marking embryonal resection areas in colorectal surgery: a feasibility study in a porcine model
Aim: In this pilot animal study we examined whether it is possible to visualize the embryonal resection layers by using intraarterial indocyanine green (ICG) staining when performing total mesorectal excision (TME) for carcinoma of the rectum. Material and methods: We injected ICG into the inferior mesenteric artery (AMI) of four swines to see whether the watershed area of the arterial supply zone can be sufficiently visualized by fluorescence imaging in order to mark the right dissection area along the fascia parietalis before and during resection. Results: We observed a fluorescence signal in all the supplied areas of AMI but not in other parts of the abdominal cavity or other organs. Additionally, the mesorectum also showed a sharp border between colored and non-colored tissue. Conclusion: In this study we present that resection borders may be determined before resection based on ICG-perfusion and we showed that intraoperative exclusive coloring of the rectum including the mesorectum is possible. Visualizing resection borders based on ICG-perfusion before settling the first cut may be a new approach in oncological surgery.