Hidajat Sugihardjo
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Hidajat Sugihardjo has a total of 19 co-authors. Here are the top co-authors by number of shared publications:
- Yudha Lesmana
Department of Civil Engineering Institut Teknologi Sepuluh Nopember (ITS) Surabaya Indonesia
4 shared publications Ahmad Basshofi Habieb
Department of Civil Engineering , Institut Teknologi Sepuluh Nopember , Surabaya , Indonesia
2 shared publications- Tavio Tavio
Institut Teknologi Sepuluh Nopember
2 shared publications - Agung Purniawan
Institut Teknologi Sepuluh Nopember
1 shared publication - Ahmad Bassofi Habieb1 shared publication
- Budi Suswanto
Institut Teknologi Sepuluh Nopember
1 shared publication
Latest Publications
- 6 July 2024
- Published by Springer Nature
- p. 953-965
An Analytical Study on Aerodynamic Stability of the Diagonal Arch Bridge
- 6 July 2024
- Published by Springer Nature
- p. 953-965
An Analytical Study on Aerodynamic Stability of the Diagonal Arch Bridge
- Open Access
- 1 December 2022
- Published by Walter de Gruyter GmbH in Civil and Environmental Engineering
- Vol. 18 (2) , 631-640
Seismic Performance of Special Truss Moment Frames With X-Bracing Type: Influence of Building Height
This study investigated the implementation of Special Truss Moment Frames (STMF) X-braced type in accordance with the recommendations of the National Earthquake Hazards Reduction Program (NEHRP), 1997:2000 and Indonesian National Standards (SNI) 1726 where it is stated that the STMF may only be used up to a maximum building height of 48 m (160 feet) for Seismic Design Category of D. The analyses compared the seismic response of apartment buildings using STMF system with different height: 44 m (11 stories), 48 m (12 stories), and 52 m (13 stories). The nonlinear behaviors were investigated through a series of nonlinear time history and pushover analyses, including the inelastic response of the structural components, top-roof displacement, drift ratio, and ductility. The structural modeling and the selection of steel sections were performed in SAP 2000 based on SNI 1726 code, considering that the structure was built on medium soil in Aceh region. Seismic performance was examined through a series of pushover and nonlinear time history analysis (NLTHA) using three scaled accelerogram: Elcentro 1940, Northridge 1994 and Kobe 1995 records. The results of the study show that in case of STMF structure with the height of 52 m (higher than the maximum height of STMF structure stated in the codes), the seismic performance of the structure was excellent and met the requirements. Axial plasticization occurred only in X-braces, not followed by the formation of plastic hinges at the ends of the ductile segments. Meanwhile, the other structural components remained elastic. This indicates that the structure can still be used after the earthquake, by replacing only the X-braced components. The drift ratio met the requirements and the roof displacements behavior was asymptotic, indicating that there is no residual horizontal displacement of the building after the seismic loads occurred.
- 1 December 2022
- Published by Walter de Gruyter GmbH in Civil and Environmental Engineering
- Vol. 18 (2) , 631-640
Open AccessSeismic Performance of Special Truss Moment Frames With X-Bracing Type: Influence of Building Height
This study investigated the implementation of Special Truss Moment Frames (STMF) X-braced type in accordance with the recommendations of the National Earthquake Hazards Reduction Program (NEHRP), 1997:2000 and Indonesian National Standards (SNI) 1726 where it is stated that the STMF may only be used up to a maximum building height of 48 m (160 feet) for Seismic Design Category of D. The analyses compared the seismic response of apartment buildings using STMF system with different height: 44 m (11 stories), 48 m (12 stories), and 52 m (13 stories). The nonlinear behaviors were investigated through a series of nonlinear time history and pushover analyses, including the inelastic response of the structural components, top-roof displacement, drift ratio, and ductility. The structural modeling and the selection of steel sections were performed in SAP 2000 based on SNI 1726 code, considering that the structure was built on medium soil in Aceh region. Seismic performance was examined through a series of pushover and nonlinear time history analysis (NLTHA) using three scaled accelerogram: Elcentro 1940, Northridge 1994 and Kobe 1995 records. The results of the study show that in case of STMF structure with the height of 52 m (higher than the maximum height of STMF structure stated in the codes), the seismic performance of the structure was excellent and met the requirements. Axial plasticization occurred only in X-braces, not followed by the formation of plastic hinges at the ends of the ductile segments. Meanwhile, the other structural components remained elastic. This indicates that the structure can still be used after the earthquake, by replacing only the X-braced components. The drift ratio met the requirements and the roof displacements behavior was asymptotic, indicating that there is no residual horizontal displacement of the building after the seismic loads occurred.
- Open Access
- 1 March 2022
- Published by Lembaga Penelitian dan Pengabdian kepada Masyarakat ITS in Jurnal Aplikasi Teknik Sipil
- Vol. 20 (1) , 95
Perbandingan Analisis Numerik Dan Analitikal Kekakuan Elastik Lateral Pada Jembatan Rangka Terbuka Dengan Menggunakan Program Abaqus
Bresing tranversal merupakan elemen yang berpengaruh terhadap stabilitas lateral batang tekan. Seperti pada jembatan rangka terbuka, tidak adanya pengikat transversal mengurangi stabilitas lateral dan batang tekan rentan terhadap tekuk. Tekuk akan menyebabkan kerusakan pada seluruh jembatan. Oleh karena itu, kekangan elastis yang diberikan oleh elemen vertikal dan balok lantai sangat penting untuk stabilitas lateral jembatan rangka terbuka. Penelitian ini membahas tentang analisis numerik model 2D wire dan modifikasi numerik model 3D solid dengan menggunakan program bantu Abaqus. Kemudian hasil analisis dibandingkan dengan Analitikal menggunakan Formula Engesser dan studi terdahulu yang dilakukan oleh Matthies (2012). Kekakuan elastik lateral yang dihasilkan oleh model 2D wire adalah 6.4675 kip/in dengan selisih masing-masing sebesar 2.179% antara numerik dengan analitikal dan sebesar 1.677% dengan studi terdahulu. Kekakuan elastik lateral yang dihasilkan oleh model 3D solid adalah 6.614 kip/in dengan selisih masing-masing sebesar 0.030% antara numerik dengan analitikal dan sebesar 0.575% dengan studi terdahulu. Model modifikasi numerik dengan 3D Solid selanjutnya akan digunakan sebagai acuan pemodelan pada penelitian lanjutan yaitu modifikasi penampang jembatan terbuka yang memudahkan aksesibilitas pengguna.
- 1 March 2022
- Published by Lembaga Penelitian dan Pengabdian kepada Masyarakat ITS in Jurnal Aplikasi Teknik Sipil
- Vol. 20 (1) , 95
Open AccessPerbandingan Analisis Numerik Dan Analitikal Kekakuan Elastik Lateral Pada Jembatan Rangka Terbuka Dengan Menggunakan Program Abaqus
Bresing tranversal merupakan elemen yang berpengaruh terhadap stabilitas lateral batang tekan. Seperti pada jembatan rangka terbuka, tidak adanya pengikat transversal mengurangi stabilitas lateral dan batang tekan rentan terhadap tekuk. Tekuk akan menyebabkan kerusakan pada seluruh jembatan. Oleh karena itu, kekangan elastis yang diberikan oleh elemen vertikal dan balok lantai sangat penting untuk stabilitas lateral jembatan rangka terbuka. Penelitian ini membahas tentang analisis numerik model 2D wire dan modifikasi numerik model 3D solid dengan menggunakan program bantu Abaqus. Kemudian hasil analisis dibandingkan dengan Analitikal menggunakan Formula Engesser dan studi terdahulu yang dilakukan oleh Matthies (2012). Kekakuan elastik lateral yang dihasilkan oleh model 2D wire adalah 6.4675 kip/in dengan selisih masing-masing sebesar 2.179% antara numerik dengan analitikal dan sebesar 1.677% dengan studi terdahulu. Kekakuan elastik lateral yang dihasilkan oleh model 3D solid adalah 6.614 kip/in dengan selisih masing-masing sebesar 0.030% antara numerik dengan analitikal dan sebesar 0.575% dengan studi terdahulu. Model modifikasi numerik dengan 3D Solid selanjutnya akan digunakan sebagai acuan pemodelan pada penelitian lanjutan yaitu modifikasi penampang jembatan terbuka yang memudahkan aksesibilitas pengguna.
- Open Access
- 28 February 2019
- Published by Bentham Science Publishers Ltd. in The Open Civil Engineering Journal
- Vol. 13 (1) , 10-19
Development of Ductile Truss System Using Double Small Buckling-Restrained Braces: Analytical Study
Development of Ductile Truss System Using Double Small Buckling-Restrained Braces: Analytical Study
- 28 February 2019
- Published by Bentham Science Publishers Ltd. in The Open Civil Engineering Journal
- Vol. 13 (1) , 10-19
Open AccessDevelopment of Ductile Truss System Using Double Small Buckling-Restrained Braces: Analytical Study
Development of Ductile Truss System Using Double Small Buckling-Restrained Braces: Analytical Study
- Open Access
- 28 April 2018
- Published by Insight Society in International Journal on Advanced Science, Engineering and Information Technology
- Vol. 8 (2) , 540-546
Seismic Study of Application of Lead Rubber Bearings in Kutai Kartanegara Steel Arch Bridge
- 28 April 2018
- Published by Insight Society in International Journal on Advanced Science, Engineering and Information Technology
- Vol. 8 (2) , 540-546
Open AccessSeismic Study of Application of Lead Rubber Bearings in Kutai Kartanegara Steel Arch Bridge
- Open Access
- 1 January 2018
- Published by Ital Publication in Civil Engineering Journal
- Vol. 4 (1) , 24-45
FE Model of Low Grade Rubber for Modeling Housing's Low-Cost Rubber Base Isolators
An accurate selection of strain energy function (SEF) plays a very important role for predicting the actual behavior of rubber material in the finite element analysis (FEA). The common method for selecting the SEF is by using the curve fitting procedure. However, the behavior of some typical rubbers, such as low grade rubbers (average hardness value of 47.2), cannot be predicted well by only using the curve fitting procedure. To accurately predict the actual behavior of such specifically nearly incompressible material, a series of FEA were carried out to simulate the actual behavior of four physical testing materials, namely the uniaxial, the planar shear, the equibiaxial, and the volumetric tests. This FEA is intended to examine the most suitable constitutive model in representing the rubber characteristics and behavior. From the comparisons, it can be concluded that the Ogden model provides a reasonably accurate prediction compared to the remaining investigated constitutive material models. Finally, the appropriate SEF, i.e. the Ogden model, was adopted for modeling a low-cost rubber base isolator (LCRBI) in the finite element analysis (FEA). The simple uniaxial compression test of the LCRBI is required for validating that the selected SEF works for predicting the actual behavior of LCRBI.
- 1 January 2018
- Published by Ital Publication in Civil Engineering Journal
- Vol. 4 (1) , 24-45
Open AccessFE Model of Low Grade Rubber for Modeling Housing's Low-Cost Rubber Base Isolators
An accurate selection of strain energy function (SEF) plays a very important role for predicting the actual behavior of rubber material in the finite element analysis (FEA). The common method for selecting the SEF is by using the curve fitting procedure. However, the behavior of some typical rubbers, such as low grade rubbers (average hardness value of 47.2), cannot be predicted well by only using the curve fitting procedure. To accurately predict the actual behavior of such specifically nearly incompressible material, a series of FEA were carried out to simulate the actual behavior of four physical testing materials, namely the uniaxial, the planar shear, the equibiaxial, and the volumetric tests. This FEA is intended to examine the most suitable constitutive model in representing the rubber characteristics and behavior. From the comparisons, it can be concluded that the Ogden model provides a reasonably accurate prediction compared to the remaining investigated constitutive material models. Finally, the appropriate SEF, i.e. the Ogden model, was adopted for modeling a low-cost rubber base isolator (LCRBI) in the finite element analysis (FEA). The simple uniaxial compression test of the LCRBI is required for validating that the selected SEF works for predicting the actual behavior of LCRBI.
- Open Access
- 23 November 2017
- Published by IOP Publishing in IOP Conference Series: Materials Science and Engineering
- Vol. 267 (1) , 012018
Defining Appropriate Temperature for Perfect Erection Time of Steel Arch Bridge Closure to Minimize the Effect of the Thermal Stress. Case Study: The New Kutai Kartenagara Bridge, Indonesia
The impact of temperature change could govern the final stress of structural elements in the long-span steel bridges. The study was conducted to investigate the effect of temperature change during the construction of a new steel arch bridge, namely the Kutai Kartanegara Bridge. The main bridge has a total spanning length of 470 meters. The erection method of the bridge was the cantilever method with temporary towers, mast cranes, and stay cables. The deflections and internal forces of the steel elements were analyzed using the Midas Civil software. The study focuses on the effort to find the perfect erection time for the closure with regards to the temperature. By measuring the temperatures of the steel elements during the construction, it was found that they varied between 19 and 64 degrees Celsius. From the results of the analyses with various temperatures, it can be concluded that the recommended temperature for the closure erection was 44.6 degrees Celsius. This temperature is similar with the air temperature between either 6 AM and 12 noon or 12 noon and 6 PM. During this periods of time, the effect of thermal stress on the final internal forces in the bridge elements was found much lesser than those obtained during any other period of time.
- 23 November 2017
- Published by IOP Publishing in IOP Conference Series: Materials Science and Engineering
- Vol. 267 (1) , 012018
Open AccessDefining Appropriate Temperature for Perfect Erection Time of Steel Arch Bridge Closure to Minimize the Effect of the Thermal Stress. Case Study: The New Kutai Kartenagara Bridge, Indonesia
The impact of temperature change could govern the final stress of structural elements in the long-span steel bridges. The study was conducted to investigate the effect of temperature change during the construction of a new steel arch bridge, namely the Kutai Kartanegara Bridge. The main bridge has a total spanning length of 470 meters. The erection method of the bridge was the cantilever method with temporary towers, mast cranes, and stay cables. The deflections and internal forces of the steel elements were analyzed using the Midas Civil software. The study focuses on the effort to find the perfect erection time for the closure with regards to the temperature. By measuring the temperatures of the steel elements during the construction, it was found that they varied between 19 and 64 degrees Celsius. From the results of the analyses with various temperatures, it can be concluded that the recommended temperature for the closure erection was 44.6 degrees Celsius. This temperature is similar with the air temperature between either 6 AM and 12 noon or 12 noon and 6 PM. During this periods of time, the effect of thermal stress on the final internal forces in the bridge elements was found much lesser than those obtained during any other period of time.
- Open Access
- 16 July 2017
- Published by Wiley in Advances in Civil Engineering
- Vol. 2017, 1-11
Cumulative Ductility and Hysteretic Behavior of Small Buckling-Restrained Braces
Cumulative ductility is defined as a ratio of total energy to elastic energy which is dissipated by an element of the structural system during cyclic loading. An element of the structural system is categorized hysteretic if the cumulative ductility factor fulfills certain criteria. This study investigated both analytically and experimentally Small Buckling-Restrained Braces (SBRBs). The core of bracings was modeled using Menegotto-Pinto and bilinear functions. The restrained bracing members were in the shape of square hollow steel section. They were made of the assembly of two L-shaped steel sections. From the experimental study on four SBRB specimens, it was proven that the proposed SBRBs have performed relatively stable hysteretic curves up to two percent of strain and the cumulative ductility factor of 199–450. This value is sufficient for the Buckling-Restrained Brace (BRB) elements as elastoplastic structural components. The comparisons of the hysteretic behaviors resulted by SBRB specimens using the Menegotto-Pinto functions and experiments exhibited good agreements, while the amount of energy dissipated by the SBRB specimens using the bilinear model agreed well with the experimental results. Based on the behavior of the experimental hysteretic, implementing the proposed SBRBs as components in ductile truss system is recommended.
- 16 July 2017
- Published by Wiley in Advances in Civil Engineering
- Vol. 2017, 1-11
Open AccessCumulative Ductility and Hysteretic Behavior of Small Buckling-Restrained Braces
Cumulative ductility is defined as a ratio of total energy to elastic energy which is dissipated by an element of the structural system during cyclic loading. An element of the structural system is categorized hysteretic if the cumulative ductility factor fulfills certain criteria. This study investigated both analytically and experimentally Small Buckling-Restrained Braces (SBRBs). The core of bracings was modeled using Menegotto-Pinto and bilinear functions. The restrained bracing members were in the shape of square hollow steel section. They were made of the assembly of two L-shaped steel sections. From the experimental study on four SBRB specimens, it was proven that the proposed SBRBs have performed relatively stable hysteretic curves up to two percent of strain and the cumulative ductility factor of 199–450. This value is sufficient for the Buckling-Restrained Brace (BRB) elements as elastoplastic structural components. The comparisons of the hysteretic behaviors resulted by SBRB specimens using the Menegotto-Pinto functions and experiments exhibited good agreements, while the amount of energy dissipated by the SBRB specimens using the bilinear model agreed well with the experimental results. Based on the behavior of the experimental hysteretic, implementing the proposed SBRBs as components in ductile truss system is recommended.
- 1 January 2017
- Published by AIP Publishing in AIP Conference Proceedings
- Vol. 1903, 020021
Behavior of rubber base isolator with various shape factors
The base isolator is the most effective technique in decreasing earthquake force that transmits to the building. This system is developed for earthquake protection by increasing the frequency of the structure away from the fundamental frequency of seismic excitation and fixed base structure. The layer number of rubber and reinforcement has an important influence to the vertical and horizontal behaviors of base isolation system. The parameters of shape factor denoted S are used to present the number of layers. A series finite element analysis (FEA) was carried out to study the influence of shape factor (S) of base isolation to the vertical and horizontal behaviors. Three dimensional models of base isolations with different shape factor values were created and analyzed by ANSYS. The models were subjected to axial and combination of vertical and horizontal loads to observe their vertical and horizontal behaviors, respectively. The results of the study indicate that the values of shape factor have no significant influence to the horizontal behavior due to constant thickness of overall rubber layers. On the contrary, the opposite conditions were found on their vertical behaviors. From the study, it can be concluded that the increase of shape factor value gave a considerable impact to the vertical strength of base isolation. In other words, it can be said that the increase of shape factor value also increases the vertical stiffness of base isolators.
- 1 January 2017
- Published by AIP Publishing in AIP Conference Proceedings
- Vol. 1903, 020021
Behavior of rubber base isolator with various shape factors
The base isolator is the most effective technique in decreasing earthquake force that transmits to the building. This system is developed for earthquake protection by increasing the frequency of the structure away from the fundamental frequency of seismic excitation and fixed base structure. The layer number of rubber and reinforcement has an important influence to the vertical and horizontal behaviors of base isolation system. The parameters of shape factor denoted S are used to present the number of layers. A series finite element analysis (FEA) was carried out to study the influence of shape factor (S) of base isolation to the vertical and horizontal behaviors. Three dimensional models of base isolations with different shape factor values were created and analyzed by ANSYS. The models were subjected to axial and combination of vertical and horizontal loads to observe their vertical and horizontal behaviors, respectively. The results of the study indicate that the values of shape factor have no significant influence to the horizontal behavior due to constant thickness of overall rubber layers. On the contrary, the opposite conditions were found on their vertical behaviors. From the study, it can be concluded that the increase of shape factor value gave a considerable impact to the vertical strength of base isolation. In other words, it can be said that the increase of shape factor value also increases the vertical stiffness of base isolators.