Marwan Nafea Arbilei
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Marwan Nafea Arbilei has a total of 10 co-authors. Here are the top co-authors by number of shared publications:
- Abdul Fattah Nongman
Biomaterials Synthesis Laboratory (BSL), School of Dental Sciences, Health Campus, Universiti Sains Malaysia, Kubang Kerian, Malaysia
1 shared publication Ali Waleed Hadi
Ph.D. postgraduate student Conservative Dentistry Department, College Of Dentistry-Baghdad University, Iraq
1 shared publicationAnas Falah Mahde
Assistant professor, Conservative Dentistry Department, College Of Dentistry-Baghdad University, Iraq
1 shared publicationJenan Kashan
1 shared publication- Matheel Al-Rawas
Prosthodontic Unit, School of Dental Sciences, Universiti Sains Malaysia, Health Campus, Kubang Kerian, Kota Bharu 16150, Kelantan, Malaysia
1 shared publication - Mohd Firdaus Yhaya
Universiti Sains Malaysia
1 shared publication
Latest Publications
- Open Access
- 14 November 2025
- Published by MDPI AG in Dentistry Journal
- Vol. 13 (11) , 540
From Industry to Dentistry: A Comprehensive Review of Zeolite as a Next-Generation Multifunctional Filler for Enhanced Mechanical Reinforcement and Antimicrobial Efficacy
Zeolites are becoming potentially important multifunctional fillers in dentistry, providing a distinctive blend of mechanical reinforcement, remineralization, and antimicrobial properties. Their crystalline aluminosilicate frameworks offer ion-exchange capacity, the controlled release of therapeutic ions (Ag+, Zn2+, Ca2+, Sr2+, Cu2+), and compatibility with various dental composites. Sustainable and cost-effective zeolite production has become possible due to recent developments in synthetic strategies. These include the valorization of industrial and agricultural residues that are abundant in Si and Al. The incorporation of zeolites into dental adhesives, restorative composites, glass ionomer cements, root canal sealers, prosthetic materials, and implant coatings has been shown to improve mechanical stability and remineralization potential, and enhance antibacterial protection. The unique advantage of zeolites in integrating multifunctionality within a single system is emphasized when compared with other fillers, such as hydroxyapatite nanoparticles and bioactive glass. Nevertheless, obstacles persist with respect to clinical validation, regulatory pathways, and long-term biocompatibility. This review critically assesses the structure–function relationships, synthesis strategies, and dental applications of zeolites, while also delineating future perspectives for their translation into clinically approved, sustainable dental biomaterials.
- 14 November 2025
- Published by MDPI AG in Dentistry Journal
- Vol. 13 (11) , 540
Open AccessFrom Industry to Dentistry: A Comprehensive Review of Zeolite as a Next-Generation Multifunctional Filler for Enhanced Mechanical Reinforcement and Antimicrobial Efficacy
Zeolites are becoming potentially important multifunctional fillers in dentistry, providing a distinctive blend of mechanical reinforcement, remineralization, and antimicrobial properties. Their crystalline aluminosilicate frameworks offer ion-exchange capacity, the controlled release of therapeutic ions (Ag+, Zn2+, Ca2+, Sr2+, Cu2+), and compatibility with various dental composites. Sustainable and cost-effective zeolite production has become possible due to recent developments in synthetic strategies. These include the valorization of industrial and agricultural residues that are abundant in Si and Al. The incorporation of zeolites into dental adhesives, restorative composites, glass ionomer cements, root canal sealers, prosthetic materials, and implant coatings has been shown to improve mechanical stability and remineralization potential, and enhance antibacterial protection. The unique advantage of zeolites in integrating multifunctionality within a single system is emphasized when compared with other fillers, such as hydroxyapatite nanoparticles and bioactive glass. Nevertheless, obstacles persist with respect to clinical validation, regulatory pathways, and long-term biocompatibility. This review critically assesses the structure–function relationships, synthesis strategies, and dental applications of zeolites, while also delineating future perspectives for their translation into clinically approved, sustainable dental biomaterials.
- 28 October 2025
- Published by Trans Tech Publications, Ltd. in Nano Hybrids and Composites
- Vol. 47, 17-29
Effect of FDM 3D Printing Process Parameters on Polylactic Acid in Impact Testing for Medical Implants
Polylactic acid (PLA) has become a promising material for medical implants due to its biocompatibility, biodegradability, and favorable mechanical properties. With advancements in Fused Deposition Modeling (FDM) 3D printing technology, it is possible to further optimize the performance of PLA by adjusting printing parameters. This optimization is crucial for enhancing the energy absorption and durability of PLA, especially in applications like medical implants that require reliable mechanical strength. This study utilized Response Surface Methodology (RSM) with the Box-Behnken Design (BBD) to investigate the effects of key FDM 3D printing parameters—layer thickness, infill pattern, and infill density—on the energy absorption and durability of PLA. A total of 15 experiments were conducted, with each factor tested at three levels. The standard Charpy impact test (ISO 179) was used to measure energy absorption in samples of dimensions 80x10x4 mm. This research aims to identify the key FDM 3D printing parameters that maximize the energy absorption and durability of polylactic acid (PLA) for use in medical implants, leveraging PLA's biocompatibility and mechanical properties. The study found that infill density and infill pattern are the two most critical factors affecting the energy absorption and durability of PLA. An infill density of 80% was determined to be optimal, as higher densities significantly improved energy absorption. Additionally, the grid infill pattern, combined with the highest layer thickness of 0.3 mm, provided the best performance. In conclusion, these findings offer valuable insights for optimizing PLA in medical implant applications, with potential for further refinement based on specific use cases.
- 28 October 2025
- Published by Trans Tech Publications, Ltd. in Nano Hybrids and Composites
- Vol. 47, 17-29
Effect of FDM 3D Printing Process Parameters on Polylactic Acid in Impact Testing for Medical Implants
Polylactic acid (PLA) has become a promising material for medical implants due to its biocompatibility, biodegradability, and favorable mechanical properties. With advancements in Fused Deposition Modeling (FDM) 3D printing technology, it is possible to further optimize the performance of PLA by adjusting printing parameters. This optimization is crucial for enhancing the energy absorption and durability of PLA, especially in applications like medical implants that require reliable mechanical strength. This study utilized Response Surface Methodology (RSM) with the Box-Behnken Design (BBD) to investigate the effects of key FDM 3D printing parameters—layer thickness, infill pattern, and infill density—on the energy absorption and durability of PLA. A total of 15 experiments were conducted, with each factor tested at three levels. The standard Charpy impact test (ISO 179) was used to measure energy absorption in samples of dimensions 80x10x4 mm. This research aims to identify the key FDM 3D printing parameters that maximize the energy absorption and durability of polylactic acid (PLA) for use in medical implants, leveraging PLA's biocompatibility and mechanical properties. The study found that infill density and infill pattern are the two most critical factors affecting the energy absorption and durability of PLA. An infill density of 80% was determined to be optimal, as higher densities significantly improved energy absorption. Additionally, the grid infill pattern, combined with the highest layer thickness of 0.3 mm, provided the best performance. In conclusion, these findings offer valuable insights for optimizing PLA in medical implant applications, with potential for further refinement based on specific use cases.
- Open Access
- 6 July 2022
- Published by Universidad Tecnica de Manabi in International journal of health sciences
- p. 6316-6320
Introducing cobalt nickel aluminum ferromagnetic shape memory alloy for endodontic file manufacturing
Since the introduction of nickel titanium (NiTi) to the field of endodontics, it paved the way for fast and reliable root canal instrumentation. Rotary instruments are solely manufactured from NiTi alloy, due to its favorable mechanical and physical properties such as flexibility and cutting efficiency. The main problem with rotary NiTi instruments is their high fatigue susceptibility, and the unexpected incident of instrument separation inside the root canal, complicating the case even further and might even doom the tooth for extraction it the fractured fragment was unretrievable with the presence of peri-apical pathology. Many attempts were made to enhance the physical and mechanical properties of NiTi alloy through modification to the manufacturing process or with different heat treatment or even adding alloying elements to it. However, there has never been an attempt to replace the whole alloy. Cobalt Nickel Aluminum (Co-Ni-Al) alloy is a ferromagnetic shape memory (FMSM) alloy, possessing favorable mechanical and physical properties making it a good candidate to replace NiTi in the manufacturing of rotary instruments. With its main advantage being the ability to be retrieved with magnetic pulses after being separated.
- 6 July 2022
- Published by Universidad Tecnica de Manabi in International journal of health sciences
- p. 6316-6320
Open AccessIntroducing cobalt nickel aluminum ferromagnetic shape memory alloy for endodontic file manufacturing
Since the introduction of nickel titanium (NiTi) to the field of endodontics, it paved the way for fast and reliable root canal instrumentation. Rotary instruments are solely manufactured from NiTi alloy, due to its favorable mechanical and physical properties such as flexibility and cutting efficiency. The main problem with rotary NiTi instruments is their high fatigue susceptibility, and the unexpected incident of instrument separation inside the root canal, complicating the case even further and might even doom the tooth for extraction it the fractured fragment was unretrievable with the presence of peri-apical pathology. Many attempts were made to enhance the physical and mechanical properties of NiTi alloy through modification to the manufacturing process or with different heat treatment or even adding alloying elements to it. However, there has never been an attempt to replace the whole alloy. Cobalt Nickel Aluminum (Co-Ni-Al) alloy is a ferromagnetic shape memory (FMSM) alloy, possessing favorable mechanical and physical properties making it a good candidate to replace NiTi in the manufacturing of rotary instruments. With its main advantage being the ability to be retrieved with magnetic pulses after being separated.
- 1 December 2018
- Published by University of Technology in Engineering and Technology Journal
- Vol. 36 (12A) , 1226-1235
Mechanical Properties Modeling and Optimization for Polymeric Matrix Hybrid Bio Composite for Scaffolds Application
- 1 December 2018
- Published by University of Technology in Engineering and Technology Journal
- Vol. 36 (12A) , 1226-1235
Mechanical Properties Modeling and Optimization for Polymeric Matrix Hybrid Bio Composite for Scaffolds Application
- 1 January 2018
- Published by AIP Publishing in AIP Conference Proceedings
- Vol. 1968, 030035
Prediction of mechanical and wear properties of 6026 aluminum alloy waste to be used in prosthetics limbs
- 1 January 2018
- Published by AIP Publishing in AIP Conference Proceedings
- Vol. 1968, 030035
Prediction of mechanical and wear properties of 6026 aluminum alloy waste to be used in prosthetics limbs