Samir M. Abdel-Mageed
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Samir M. Abdel-Mageed has a total of 31 co-authors. Here are the top co-authors by number of shared publications:
- Ehab Tawfik Mohamed
Medical Biophysics Department, Medical Research Institute, Alexandria University, Alexandria, Egypt
8 shared publications - Metwally A. Kotb
Departments of Medical Biophysics Medical Research Institute, Alexandria University Egypt
2 shared publications - Mohamed I. Badawi
Pharos University, Faculty of Applied Health Sciences Technology ,Biomedical
2 shared publications Samy H. Darwish
Department of Electrical Engineering, Faculty of Engineering, Pharos University, Alexandria, Egypt
2 shared publicationsA. I. Baess
Chest diseases department, Faculty of medicine, Alexandria University, Alexandria, Egypt
1 shared publicationA. M. Moro
Biomedical Equipment and Systems Department, Faculty of Applied Medical Sciences, 6 October University, Cairo
1 shared publication
Latest Publications
- 12 November 2021
- Published by Wiley in Journal of Viral Hepatitis
- Vol. 29 (2) , 147-155
Electronic nose versus quadrupole mass spectrometry for identifying viral hepatitis C patients
Hepatitis C is a leading cause of liver disease and transplantation and is a significant burden on public health worldwide. This study aimed to apply the Electronic Nose (E‐Nose) and quadrupole Mass Spectrometry (MS/MS) technologies for screening blood samples from hepatitis C patients and healthy controls. We analysed volatile organic compounds (VOCs) in the headspace over blood samples to identify those VOCs characteristic for diagnosing hepatitis C patients. The study comprised 150 acute hepatitis C patients with age range: 24–59 years, and mean age ±SD: 41.5 ± 12.8 years and 150 age‐matched healthy controls (age range: 24–51 and mean age: 40.11 ± 4.89 years) from the Hospital of the Medical Research Institute, Alexandria University, Alexandria, Egypt. Collected blood samples were analysed qualitatively and quantitatively using the E‐Nose and MS/MS techniques, respectively. Principal component analysis of the E‐Nose 10‐sensor responses accurately classified blood samples from hepatitis C patients and healthy controls. The first two principal components explained over 98.35% of the variance in signals with no false‐positive (healthy controls) or false‐negative (hepatitis C patients) results. MS/MS showed two fragmentation ions at m/z of 104 and 151 Da with the positive electrospray ionization mode (ESI+) in blood samples for hepatitis C patients, but not for healthy controls or background water samples. We identified the two specific fragmentation ions at m/z 104 and m/z 151 Da as malonic acid (MF: C3H4O4; MW: 104.06 g/mol) and monosaccharide pentose (MF: C5H10O5; MW: 150.13 g/mol) in VOCs of the headspace over blood samples for hepatitis C patients. This provides a rationale for developing diagnostic tests for hepatitis C virus based on altered trace VOCs concentrations using the relatively inexpensive, easy‐to‐use, portable and non‐invasive E‐Nose technology.
- 12 November 2021
- Published by Wiley in Journal of Viral Hepatitis
- Vol. 29 (2) , 147-155
Electronic nose versus quadrupole mass spectrometry for identifying viral hepatitis C patients
Hepatitis C is a leading cause of liver disease and transplantation and is a significant burden on public health worldwide. This study aimed to apply the Electronic Nose (E‐Nose) and quadrupole Mass Spectrometry (MS/MS) technologies for screening blood samples from hepatitis C patients and healthy controls. We analysed volatile organic compounds (VOCs) in the headspace over blood samples to identify those VOCs characteristic for diagnosing hepatitis C patients. The study comprised 150 acute hepatitis C patients with age range: 24–59 years, and mean age ±SD: 41.5 ± 12.8 years and 150 age‐matched healthy controls (age range: 24–51 and mean age: 40.11 ± 4.89 years) from the Hospital of the Medical Research Institute, Alexandria University, Alexandria, Egypt. Collected blood samples were analysed qualitatively and quantitatively using the E‐Nose and MS/MS techniques, respectively. Principal component analysis of the E‐Nose 10‐sensor responses accurately classified blood samples from hepatitis C patients and healthy controls. The first two principal components explained over 98.35% of the variance in signals with no false‐positive (healthy controls) or false‐negative (hepatitis C patients) results. MS/MS showed two fragmentation ions at m/z of 104 and 151 Da with the positive electrospray ionization mode (ESI+) in blood samples for hepatitis C patients, but not for healthy controls or background water samples. We identified the two specific fragmentation ions at m/z 104 and m/z 151 Da as malonic acid (MF: C3H4O4; MW: 104.06 g/mol) and monosaccharide pentose (MF: C5H10O5; MW: 150.13 g/mol) in VOCs of the headspace over blood samples for hepatitis C patients. This provides a rationale for developing diagnostic tests for hepatitis C virus based on altered trace VOCs concentrations using the relatively inexpensive, easy‐to‐use, portable and non‐invasive E‐Nose technology.
- 1 July 2019
- Published by Elsevier in Journal of Clinical Densitometry
- Vol. 22 (3) , 382-390
A Novel Morphological Analysis of DXA-DICOM Images by Artificial Neural Networks for Estimating Bone Mineral Density in Health and Disease
- 1 July 2019
- Published by Elsevier in Journal of Clinical Densitometry
- Vol. 22 (3) , 382-390
A Novel Morphological Analysis of DXA-DICOM Images by Artificial Neural Networks for Estimating Bone Mineral Density in Health and Disease
- Open Access
- 19 March 2019
- Published by University of South Bohemia in Ceske Budejovice in Journal of Applied Biomedicine
- Vol. 17 (1) , 67
Volatile organic compounds of biofluids for detecting lung cancer by an electronic nose based on artificial neural network
Lung cancer (LC) incidence represents 11.5% of all new cancers, resulting in 1.72 million deaths worldwide in 2015. With the aim to investigate the capability of the electronic nose (e-nose) technology for detecting and differentiating complex...
- 19 March 2019
- Published by University of South Bohemia in Ceske Budejovice in Journal of Applied Biomedicine
- Vol. 17 (1) , 67
Open AccessVolatile organic compounds of biofluids for detecting lung cancer by an electronic nose based on artificial neural network
Lung cancer (LC) incidence represents 11.5% of all new cancers, resulting in 1.72 million deaths worldwide in 2015. With the aim to investigate the capability of the electronic nose (e-nose) technology for detecting and differentiating complex...
- 1 July 2017
- Published by International Union Against Tuberculosis and Lung Disease in The International Journal of Tuberculosis and Lung Disease
- Vol. 21 (7) , 810-817
Qualitative analysis of biological tuberculosis samples by an electronic nose-based artificial neural network
To apply an e-nose system for monitoring headspace volatiles in biological samples from Egyptian patients with active pulmonary tuberculosis (TB) and healthy controls (HCs) and compare them with standard sputum analysis. The study population comprised 260 (140 males, 120 females) newly diagnosed TB patients and 240 (120 males, 120 females) HCs matched by age and socio-economic level admitted to hospitals specialising in chest diseases in Alexandria, Behera, Giza and Damietta Governorates, Egypt. Participants provided a history of TB and underwent clinical examinations, chest X-ray, and microbiological and e-nose analyses. Biological samples (blood, breath, sputum and urine) were collected. Being a confirmed TB patient was directly proportional to e-nose 10-sensor responses. Principal component analysis clusters showed a clear distinction between TB and HC groups, with variances of 93%, 85%, 75% and 95% for blood, breath, sputum and urine samples, respectively. Overall accuracy, sensitivity and specificity of the artificial neural network (ANN) analysis for classifying samples were >99%. The e-nose successfully distinguished TB patients from HC participants for all measured biological samples with great precision. With urine samples gaining broader acceptance for clinical diagnosis, an e-nose-based ANN can be a very useful tool for low-cost mass screening and early detection of TB patients in developing countries.
- 1 July 2017
- Published by International Union Against Tuberculosis and Lung Disease in The International Journal of Tuberculosis and Lung Disease
- Vol. 21 (7) , 810-817
Qualitative analysis of biological tuberculosis samples by an electronic nose-based artificial neural network
To apply an e-nose system for monitoring headspace volatiles in biological samples from Egyptian patients with active pulmonary tuberculosis (TB) and healthy controls (HCs) and compare them with standard sputum analysis. The study population comprised 260 (140 males, 120 females) newly diagnosed TB patients and 240 (120 males, 120 females) HCs matched by age and socio-economic level admitted to hospitals specialising in chest diseases in Alexandria, Behera, Giza and Damietta Governorates, Egypt. Participants provided a history of TB and underwent clinical examinations, chest X-ray, and microbiological and e-nose analyses. Biological samples (blood, breath, sputum and urine) were collected. Being a confirmed TB patient was directly proportional to e-nose 10-sensor responses. Principal component analysis clusters showed a clear distinction between TB and HC groups, with variances of 93%, 85%, 75% and 95% for blood, breath, sputum and urine samples, respectively. Overall accuracy, sensitivity and specificity of the artificial neural network (ANN) analysis for classifying samples were >99%. The e-nose successfully distinguished TB patients from HC participants for all measured biological samples with great precision. With urine samples gaining broader acceptance for clinical diagnosis, an e-nose-based ANN can be a very useful tool for low-cost mass screening and early detection of TB patients in developing countries.
- 1 April 2016
- Published by Elsevier in Journal of Theoretical Biology
- Vol. 394, 109-116
Comparative modeling of combined transport of water and graded-size molecules across the glomerular capillary wall
- 1 April 2016
- Published by Elsevier in Journal of Theoretical Biology
- Vol. 394, 109-116
Comparative modeling of combined transport of water and graded-size molecules across the glomerular capillary wall
- Open Access
- 15 March 2016
- Published by International Association of Biomedical Sciences in International Journal of Biomedical Science
- Vol. 12 (1) , 42-47
Total Body Capacitance for Estimating Human Basal Metabolic Rate in an Egyptian Population
Determining basal metabolic rate (BMR) is important for estimating total energy needs in the human being yet, concerns have been raised regarding the suitability of sex-specific equations based on age and weight for its calculation on an individual or population basis. It has been shown that body cell mass (BCM) is the body compartment responsible for BMR. The objectives of this study were to investigate the relationship between total body capacitance (TBC), which is considered as an expression for BCM, and BMR and to develop a formula for calculating BMR in comparison with widely used equations. Fifty healthy nonsmoking male volunteers [mean age (± SD): 24.93 ± 4.15 year and body mass index (BMI): 25.63 ± 3.59 kg/m2] and an equal number of healthy nonsmoking females matched for age and BMI were recruited for the study. TBC and BMR were measured for all participants using octopolar bioelectric impedance analysis and indirect calorimetry techniques, respectively. A significant regressing equation based on the covariates: sex, weight, and TBC for estimating BMR was derived (R=0.96, SEE=48.59 kcal, and P<0.0001), which will be useful for nutritional and health status assessment for both individuals and populations
- 15 March 2016
- Published by International Association of Biomedical Sciences in International Journal of Biomedical Science
- Vol. 12 (1) , 42-47
Open AccessTotal Body Capacitance for Estimating Human Basal Metabolic Rate in an Egyptian Population
Determining basal metabolic rate (BMR) is important for estimating total energy needs in the human being yet, concerns have been raised regarding the suitability of sex-specific equations based on age and weight for its calculation on an individual or population basis. It has been shown that body cell mass (BCM) is the body compartment responsible for BMR. The objectives of this study were to investigate the relationship between total body capacitance (TBC), which is considered as an expression for BCM, and BMR and to develop a formula for calculating BMR in comparison with widely used equations. Fifty healthy nonsmoking male volunteers [mean age (± SD): 24.93 ± 4.15 year and body mass index (BMI): 25.63 ± 3.59 kg/m2] and an equal number of healthy nonsmoking females matched for age and BMI were recruited for the study. TBC and BMR were measured for all participants using octopolar bioelectric impedance analysis and indirect calorimetry techniques, respectively. A significant regressing equation based on the covariates: sex, weight, and TBC for estimating BMR was derived (R=0.96, SEE=48.59 kcal, and P<0.0001), which will be useful for nutritional and health status assessment for both individuals and populations
- 1 January 2015
- Published by ScopeMed in International Journal of Therapies and Rehabilitation Research
- Vol. 4 (2) , 15-17
Efficacy of Pulsed Direct Current in Tap Water Iontophoresis in Treating Primary Palmar Hyperhidrosis in pediatrics
- 1 January 2015
- Published by ScopeMed in International Journal of Therapies and Rehabilitation Research
- Vol. 4 (2) , 15-17
Efficacy of Pulsed Direct Current in Tap Water Iontophoresis in Treating Primary Palmar Hyperhidrosis in pediatrics
- Open Access
- 1 January 2014
- Published by Herbert Publications PVT LTD in Breast Cancer Reports
- Vol. 1 (1) , 1
Effect of adjuvant chemotherapy on carboxytelopeptide of cross-linked type I collagen of egyptian women with non-metastatic breast cancer
Background: Women with breast cancer are at increased risk for the development of osteoporosis and skeletal fractures, as consequences of aromatase inhibition or chemotherapy-induced ovarian failure. We
- 1 January 2014
- Published by Herbert Publications PVT LTD in Breast Cancer Reports
- Vol. 1 (1) , 1
Open AccessEffect of adjuvant chemotherapy on carboxytelopeptide of cross-linked type I collagen of egyptian women with non-metastatic breast cancer
Background: Women with breast cancer are at increased risk for the development of osteoporosis and skeletal fractures, as consequences of aromatase inhibition or chemotherapy-induced ovarian failure. We
- 12 September 2013
- Published by Wiley in Hematological Oncology
- Vol. 32 (3) , 165-167
Electronic nose for tracking different types of leukaemia: future prospects in diagnosis
- 12 September 2013
- Published by Wiley in Hematological Oncology
- Vol. 32 (3) , 165-167
Electronic nose for tracking different types of leukaemia: future prospects in diagnosis
- Open Access
- 1 January 2013
- Published by Nofer Institute of Occupational Medicine in International Journal of Occupational Medicine and Environmental Health
- Vol. 26 (1) , 165-172
Electronic noses for monitoring benzene occupational exposure in biological samples of Egyptian workers
Benzene is commonly emitted in several industries, leading to widespread environmental and occupational exposure hazards. While less toxic solvents have been substituted for benzene, it is still a component of petroleum products and is a trace impurity in industrial products resulting in continued higher occupational exposures in industrial settings in developing countries. We investigated the potential use of an electronic nose (e-nose) to monitor the headspace volatiles in biological samples from benzene-exposed Egyptian workers and non-exposed controls. The study population comprised 150 non-smoking male workers exposed to benzene and an equal number of matching non-exposed controls. We determined biomarkers of benzene used to estimate exposure and risk including: benzene in exhaled air and blood; and its urinary metabolites such as phenol and muconic acid using gas chromatography technique and a portable e-nose. The average benzene concentration measured in the ambient air of the workplace of all studied industrial settings in Alexandria, Egypt; was 97.56±88.12 μg/m3 (range: 4.69–260.86 μg/m3). Levels of phenol and muconic acid were significantly (p < 0.001) higher in both blood and urine of benzene-exposed workers as compared to non-exposed controls. The e-nose technology has successfully classified and distinguished benzene-exposed workers from non-exposed controls for all measured samples of blood, urine and the exhaled air with a very high degree of precision. Thus, it will be a very useful tool for the low-cost mass screening and early detection of health hazards associated with the exposure to benzene in the industry.
- 1 January 2013
- Published by Nofer Institute of Occupational Medicine in International Journal of Occupational Medicine and Environmental Health
- Vol. 26 (1) , 165-172
Open AccessElectronic noses for monitoring benzene occupational exposure in biological samples of Egyptian workers
Benzene is commonly emitted in several industries, leading to widespread environmental and occupational exposure hazards. While less toxic solvents have been substituted for benzene, it is still a component of petroleum products and is a trace impurity in industrial products resulting in continued higher occupational exposures in industrial settings in developing countries. We investigated the potential use of an electronic nose (e-nose) to monitor the headspace volatiles in biological samples from benzene-exposed Egyptian workers and non-exposed controls. The study population comprised 150 non-smoking male workers exposed to benzene and an equal number of matching non-exposed controls. We determined biomarkers of benzene used to estimate exposure and risk including: benzene in exhaled air and blood; and its urinary metabolites such as phenol and muconic acid using gas chromatography technique and a portable e-nose. The average benzene concentration measured in the ambient air of the workplace of all studied industrial settings in Alexandria, Egypt; was 97.56±88.12 μg/m3 (range: 4.69–260.86 μg/m3). Levels of phenol and muconic acid were significantly (p < 0.001) higher in both blood and urine of benzene-exposed workers as compared to non-exposed controls. The e-nose technology has successfully classified and distinguished benzene-exposed workers from non-exposed controls for all measured samples of blood, urine and the exhaled air with a very high degree of precision. Thus, it will be a very useful tool for the low-cost mass screening and early detection of health hazards associated with the exposure to benzene in the industry.