Elisa Fornasari
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Elisa Fornasari has a total of 16 co-authors. Here are the top co-authors by number of shared publications:
- Gian Maria Cavallini
Department of Surgery, Medicine, Dentistry and Morphological Sciences, with Interest in Transplants, Oncology and Regenerative Medicine, University of Modena and Reggio Emilia, 41121 Modena, Italy
5 shared publications - Michele De Maria
Ophthalmology Unit, Azienda USL-IRCCS di Reggio Emilia, Reggio Emilia, Italy
5 shared publications - Tommaso Verdina
Institute of Ophthalmology, University of Modena and Reggio Emilia, Modena, Italy
4 shared publications Giulio Torlai
Institute of Ophthalmology, University of Modena, Modena 41100, Italy
2 shared publicationsLuca Campi
Institute of Ophthalmology, University of Modena and Reggio Emilia, Via del Pozzo 71, 41100, Modena, Italy
2 shared publications- Luca Campi
Institute of Ophthalmology, University of Modena and Reggio Emilia, Modena, Italy
2 shared publications
Latest Publications
- 14 October 2018
- Published by SAGE Publications in European Journal of Ophthalmology
- Vol. 29 (6) , 629-635
Bimanual femtosecond laser-assisted cataract surgery compared to standard bimanual phacoemulsification: A case–control study
Purpose: To evaluate the efficacy and safety of bimanual, low-energy femtosecond laser-assisted cataract surgery with 1.4-mm microincisions compared to standard bimanual phacoemulsification (bimanual microincision cataract surgery). Design: Prospective, non-randomized comparative case series. Methods: Bimanual femtosecond laser-assisted cataract surgery with microincisions was performed on 80 eyes (Group A) with the low-energy Ziemer LDV Z8; a matched case–control series of 80 eyes performed with standard bimanual microincision cataract surgery technique was selected for comparison (Group B). All interventions were performed by the same experienced surgeon. Intraoperative parameters were recorded as well as intra- and postoperative complications. Best corrected visual acuity, surgically induced astigmatism, central corneal thickness and endothelial cell count were evaluated before surgery and at 1 and 3 months post intervention. Results: The mean effective phaco times were 3.79 ± 2.19 s (Group A) and 4.49 ± 1.84 s (Group B) (p = 0.041). No major intra- or postoperative complications occurred. An overall significant mean best corrected visual acuity improvement was noted at 3 months, but was not statistically different between the groups. No significant changes were observed for surgically induced astigmatism or corneal pachymetry. A significant loss of endothelial cell count in both groups was detected at 3 months, with Group A reporting a significantly lower endothelial cell count loss compared to Group B (p = 0.009). Conclusion: Bimanual, low-energy femtosecond laser-assisted cataract surgery with 1.4-mm microincisions by an expert surgeon was proven to be safe and effective in this study. This technique has advantages compared with standard bimanual microincision cataract surgery in terms of endothelial preservation.
- 14 October 2018
- Published by SAGE Publications in European Journal of Ophthalmology
- Vol. 29 (6) , 629-635
Bimanual femtosecond laser-assisted cataract surgery compared to standard bimanual phacoemulsification: A case–control study
Purpose: To evaluate the efficacy and safety of bimanual, low-energy femtosecond laser-assisted cataract surgery with 1.4-mm microincisions compared to standard bimanual phacoemulsification (bimanual microincision cataract surgery). Design: Prospective, non-randomized comparative case series. Methods: Bimanual femtosecond laser-assisted cataract surgery with microincisions was performed on 80 eyes (Group A) with the low-energy Ziemer LDV Z8; a matched case–control series of 80 eyes performed with standard bimanual microincision cataract surgery technique was selected for comparison (Group B). All interventions were performed by the same experienced surgeon. Intraoperative parameters were recorded as well as intra- and postoperative complications. Best corrected visual acuity, surgically induced astigmatism, central corneal thickness and endothelial cell count were evaluated before surgery and at 1 and 3 months post intervention. Results: The mean effective phaco times were 3.79 ± 2.19 s (Group A) and 4.49 ± 1.84 s (Group B) (p = 0.041). No major intra- or postoperative complications occurred. An overall significant mean best corrected visual acuity improvement was noted at 3 months, but was not statistically different between the groups. No significant changes were observed for surgically induced astigmatism or corneal pachymetry. A significant loss of endothelial cell count in both groups was detected at 3 months, with Group A reporting a significantly lower endothelial cell count loss compared to Group B (p = 0.009). Conclusion: Bimanual, low-energy femtosecond laser-assisted cataract surgery with 1.4-mm microincisions by an expert surgeon was proven to be safe and effective in this study. This technique has advantages compared with standard bimanual microincision cataract surgery in terms of endothelial preservation.
- Open Access
- 11 January 2018
- Published by Wiley in BioMed Research International
- Vol. 2018, 1-8
Anterior Capsule of the Lens: Comparison of Morphological Properties and Apoptosis Induction following FLACS and Standard Phacoemulsification Surgery
Purpose. Comparative evaluation of morphological features of anterior capsules and apoptosis induction in epithelial cells after femtosecond laser-assisted cataract surgery (FLACS) and standard phacoemulsification surgery.Methods. Group 1: 30 FLACS anterior capsulotomies and Group 2: 30 manual anterior continuous curvilinear capsulorhexes. All patients were operated on by the same experienced surgeon. Morphological features of the anterior capsules and apoptosis induction in epithelial cells were evaluated.Results. All patients revealed a significant mean best-corrected visual acuity (BCVA) improvement 3 months after surgery, and no major intraoperative nor postoperative complications occurred. The capsular epithelium appeared to be preserved in both groups. Scanning electron microscopy analysis revealed irregular saw-tooth shaped edges in capsules from Group 1 whereas capsules from Group 2 showed regular and smooth edges. A statistically significant higher expression of the downstream apoptotic effector cleaved caspase 3 was observed in Group 1.Conclusions. The saw-tooth appearance was likely due to the progressive sequence of laser pulses on the capsule. The low energy/high frequency properties of the laser pulse, combined with an overlapped pulse pattern, resulted in highly continuous morphology of capsule edges. The higher apoptosis induction in FLACS group might be due to photodisruption-dependent plasma generation and formation of cavitation bubbles.
- 11 January 2018
- Published by Wiley in BioMed Research International
- Vol. 2018, 1-8
Open AccessAnterior Capsule of the Lens: Comparison of Morphological Properties and Apoptosis Induction following FLACS and Standard Phacoemulsification Surgery
Purpose. Comparative evaluation of morphological features of anterior capsules and apoptosis induction in epithelial cells after femtosecond laser-assisted cataract surgery (FLACS) and standard phacoemulsification surgery.Methods. Group 1: 30 FLACS anterior capsulotomies and Group 2: 30 manual anterior continuous curvilinear capsulorhexes. All patients were operated on by the same experienced surgeon. Morphological features of the anterior capsules and apoptosis induction in epithelial cells were evaluated.Results. All patients revealed a significant mean best-corrected visual acuity (BCVA) improvement 3 months after surgery, and no major intraoperative nor postoperative complications occurred. The capsular epithelium appeared to be preserved in both groups. Scanning electron microscopy analysis revealed irregular saw-tooth shaped edges in capsules from Group 1 whereas capsules from Group 2 showed regular and smooth edges. A statistically significant higher expression of the downstream apoptotic effector cleaved caspase 3 was observed in Group 1.Conclusions. The saw-tooth appearance was likely due to the progressive sequence of laser pulses on the capsule. The low energy/high frequency properties of the laser pulse, combined with an overlapped pulse pattern, resulted in highly continuous morphology of capsule edges. The higher apoptosis induction in FLACS group might be due to photodisruption-dependent plasma generation and formation of cavitation bubbles.
- 29 November 2017
- Published by Springer Nature in International Ophthalmology
- Vol. 39 (1) , 1-9
Femtosecond laser-assisted cataract surgery with bimanual technique: learning curve for an experienced cataract surgeon
To describe the intraoperative complications and the learning curve of microincision cataract surgery assisted by femtosecond laser (FLACS) with bimanual technique performed by an experienced surgeon.
- 29 November 2017
- Published by Springer Nature in International Ophthalmology
- Vol. 39 (1) , 1-9
Femtosecond laser-assisted cataract surgery with bimanual technique: learning curve for an experienced cataract surgeon
To describe the intraoperative complications and the learning curve of microincision cataract surgery assisted by femtosecond laser (FLACS) with bimanual technique performed by an experienced surgeon.
- Open Access
- 18 November 2017
- Published by Press of International Journal of Ophthalmology (IJO Press) in International Journal of Ophthalmology
- Vol. 10 (11) , 1710-1715
Bimanual microincision cataract surgery with implantation of the new Incise® MJ14 intraocular lens through a 1.4 mm incision
To analyze the visual outcomes and the posterior capsule opacification (PCO) with the new Incise® MJ14 intraocular lens (IOL) implanted through a 1.4 mm clear corneal incision (CCI) in patients who underwent bimanual microincision cataract surgery (B-MICS). Eighty eyes which underwent cataract surgery using B-MICS technique performed by the same experienced surgeon were included in the study: 40 eyes were implanted with an Incise® MJ14 IOL through a 1.4 mm CCI (group A) without enlargement of the main CCI, while 40 eyes were implanted with an Akreos® MI60 IOL with enlargement of the main CCI to 1.8 mm (group B). Best corrected visual acuity (BCVA), astigmatism and endothelial cell loss were evaluated before and after surgery at 7, 30d and 6mo. Anterior segment-optical coherence tomography (AS-OCT) of CCI was performed at 1, 3, 7, 30d, 6 and 18mo. PCO incidence was evaluated at 18mo using EPCO 2000 Software. Mean BCVA improvement and endothelial cell loss were statistically significant at 18mo in both groups with no difference between the two groups; no statistically significant difference in surgically induced astigmatism (SIA) was noticed in the two groups. At AS-OCT the only significant alterations in the CCI were endothelial gaping and local detachment of Descemet's membrane at 1 and 7d after surgery; no statistically significant alterations were found at 1, 6 and 18mo. PCO score at 18mo was 0.03±0.07 for group A and 0.08±0.18 for group B (P=0.11) with no sign of central optic plate invasion in both groups. The implant of the new Incise® MJ14 IOL through a 1.4 mm CCI and B-MICS technique appeared to be a safe and effective procedure with rapid visual recovery. PCO rate resulted very low and the CCI presented few morphological alterations which were only detectable in the first days postoperatively and achieved fast corneal healing during the long-term follow-up.
- 18 November 2017
- Published by Press of International Journal of Ophthalmology (IJO Press) in International Journal of Ophthalmology
- Vol. 10 (11) , 1710-1715
Open AccessBimanual microincision cataract surgery with implantation of the new Incise® MJ14 intraocular lens through a 1.4 mm incision
To analyze the visual outcomes and the posterior capsule opacification (PCO) with the new Incise® MJ14 intraocular lens (IOL) implanted through a 1.4 mm clear corneal incision (CCI) in patients who underwent bimanual microincision cataract surgery (B-MICS). Eighty eyes which underwent cataract surgery using B-MICS technique performed by the same experienced surgeon were included in the study: 40 eyes were implanted with an Incise® MJ14 IOL through a 1.4 mm CCI (group A) without enlargement of the main CCI, while 40 eyes were implanted with an Akreos® MI60 IOL with enlargement of the main CCI to 1.8 mm (group B). Best corrected visual acuity (BCVA), astigmatism and endothelial cell loss were evaluated before and after surgery at 7, 30d and 6mo. Anterior segment-optical coherence tomography (AS-OCT) of CCI was performed at 1, 3, 7, 30d, 6 and 18mo. PCO incidence was evaluated at 18mo using EPCO 2000 Software. Mean BCVA improvement and endothelial cell loss were statistically significant at 18mo in both groups with no difference between the two groups; no statistically significant difference in surgically induced astigmatism (SIA) was noticed in the two groups. At AS-OCT the only significant alterations in the CCI were endothelial gaping and local detachment of Descemet's membrane at 1 and 7d after surgery; no statistically significant alterations were found at 1, 6 and 18mo. PCO score at 18mo was 0.03±0.07 for group A and 0.08±0.18 for group B (P=0.11) with no sign of central optic plate invasion in both groups. The implant of the new Incise® MJ14 IOL through a 1.4 mm CCI and B-MICS technique appeared to be a safe and effective procedure with rapid visual recovery. PCO rate resulted very low and the CCI presented few morphological alterations which were only detectable in the first days postoperatively and achieved fast corneal healing during the long-term follow-up.
- 14 June 2017
- Published by Springer Nature in International Ophthalmology
- Vol. 38 (4) , 1733-1739
Postoperative diffuse opacification of a hydrophilic acrylic intraocular lens: analysis of an explant
We describe the clinicopathological and ultrastructural features of an opaque single-piece hydrophilic acrylic intraocular lens (IOL) explanted from a patient.
- 14 June 2017
- Published by Springer Nature in International Ophthalmology
- Vol. 38 (4) , 1733-1739
Postoperative diffuse opacification of a hydrophilic acrylic intraocular lens: analysis of an explant
We describe the clinicopathological and ultrastructural features of an opaque single-piece hydrophilic acrylic intraocular lens (IOL) explanted from a patient.
- 1 October 2012
- Published by Wolters Kluwer Health in Journal of Cataract & Refractive Surgery
- Vol. 38 (10) , 1743-1748
Clear corneal incisions in bimanual microincision cataract surgery: Long-term wound-healing architecture
Ena, Italy. METHODS: Patients who had uneventful bimanual MICS in the previous 2 to 16 months were examined using AS-OCT. Images were used to measure corneal thickness, incision length, incision angle, incidence of epithelial or endothelial gaping, misalignment, Descemet membrane detachment, and posterior wound retraction. RESULTS: Fifty-two eyes (33 patients) were enrolled. Mean incision length and incision angle were, respectively, 1427.91 μm and 31.19 degrees for the right hand, 1440.63 μm and 31.54 degrees for the left hand, 1474.13 μm and 31.27 degrees for temporal incisions, and 1394.41 μm and 31.46 degrees for nasal CCIs. Posterior wound retraction was the only architectural feature found. Its prevalence was 7.10% at 2 to 3 months, 31.8% at 4 to 11 months, and 33.3% at 12 months. Fifty-three percent of posterior wound retractions were in 1.8 mm CCIs and 47% in 1.4 mm CCIs. CONCLUSIONS: Bimanual MICS was not related to particular morphologic features of CCIs. The enlargement of 1 incision or construction of the incision with the dominant or the nondominant hand did not affect long-term wound architecture. Posterior wound retraction was the only architectural feature; however, its prevalence seems substantially lower than with other surgical techniques. Financial Disclosure: No author has a financial or proprietary interest in any material or method mentioned....
- 1 October 2012
- Published by Wolters Kluwer Health in Journal of Cataract & Refractive Surgery
- Vol. 38 (10) , 1743-1748
Clear corneal incisions in bimanual microincision cataract surgery: Long-term wound-healing architecture
Ena, Italy. METHODS: Patients who had uneventful bimanual MICS in the previous 2 to 16 months were examined using AS-OCT. Images were used to measure corneal thickness, incision length, incision angle, incidence of epithelial or endothelial gaping, misalignment, Descemet membrane detachment, and posterior wound retraction. RESULTS: Fifty-two eyes (33 patients) were enrolled. Mean incision length and incision angle were, respectively, 1427.91 μm and 31.19 degrees for the right hand, 1440.63 μm and 31.54 degrees for the left hand, 1474.13 μm and 31.27 degrees for temporal incisions, and 1394.41 μm and 31.46 degrees for nasal CCIs. Posterior wound retraction was the only architectural feature found. Its prevalence was 7.10% at 2 to 3 months, 31.8% at 4 to 11 months, and 33.3% at 12 months. Fifty-three percent of posterior wound retractions were in 1.8 mm CCIs and 47% in 1.4 mm CCIs. CONCLUSIONS: Bimanual MICS was not related to particular morphologic features of CCIs. The enlargement of 1 incision or construction of the incision with the dominant or the nondominant hand did not affect long-term wound architecture. Posterior wound retraction was the only architectural feature; however, its prevalence seems substantially lower than with other surgical techniques. Financial Disclosure: No author has a financial or proprietary interest in any material or method mentioned....