Emad ElSamahy
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Emad ElSamahy has a total of 27 co-authors. Here are the top co-authors by number of shared publications:
- Mahdi Mahfouf
School of Electrical and Electronic Engineering, University of Sheffield, Sheffield, U.K.
4 shared publications Ahmed Genedy
Medical Services Administration Cairo, Egypt
3 shared publicationsD.A. Linkens
3 shared publicationsM. Mahfouf
Automatic Control and Systems Engineering Department, The University of Sheffield, United Kingdom
3 shared publications- Mohamed A. Abbass
Department of Biomedical Engineering, University of Cincinnati, Cincinnati, OH, USA
3 shared publications - Adam Charles Roberts
Nanyang Technological University
2 shared publications
Latest Publications
- Open Access
Deep-GenMut: Automated genetic mutation classification in oncology: A deep learning comparative study
- 16 November 2023
- Published by Springer Nature
- p. 249-259
A Comparative Study of Features Selection in the Context of Forecasting PM2.5 Concentration
- 16 November 2023
- Published by Springer Nature
- p. 249-259
A Comparative Study of Features Selection in the Context of Forecasting PM2.5 Concentration
- 24 August 2021
- Published by Springer Nature
- p. 407-421
Real-Time Machine Learning-Based Framework for the Analysis of Banking Financial Data
- 24 August 2021
- Published by Springer Nature
- p. 407-421
Real-Time Machine Learning-Based Framework for the Analysis of Banking Financial Data
- 5 August 2016
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Fuzzy Systems
- Vol. 25 (1) , 43-57
Psychophysiologically Based Real-Time Adaptive General Type 2 Fuzzy Modeling and Self-Organizing Control of Operator's Performance Undertaking a Cognitive Task
This paper presents a new modeling and control fuzzy-based framework validated with real-time experiments on human participants experiencing stress via mental arithmetic cognitive tasks identified through psychophysiological markers. The ultimate aim of the modeling/control framework is to prevent performance breakdown in human-computer interactive systems with a special focus on human performance. Two designed modeling/control experiments which consist of carrying-out arithmetic operations of varying difficulty levels were performed by ten participants (operators) in the study. With this new technique, modeling is achieved through a new adaptive, self-organizing, and interpretable modeling framework based on general Type-2 fuzzy sets. This framework is able to learn in real time through the implementation of a restructured performance learning algorithm that identifies important features in the data without the need for prior training. The information learnt by the model is later exploited via an energy model based controller that infers adequate control actions by changing the difficulty level of the arithmetic operations in the human-computer interaction system; these actions being based on the most current psychophysiological state of the subject under study. The real-time implementation of the proposed modeling and control configurations for the human-machine interaction under study shows superior performance as compared to other forms of modeling and control, with minimal intervention in terms of model retraining or parameter retuning to deal with uncertainties, disturbances, and inter/intrasubject parameter variability.
- 5 August 2016
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Fuzzy Systems
- Vol. 25 (1) , 43-57
Psychophysiologically Based Real-Time Adaptive General Type 2 Fuzzy Modeling and Self-Organizing Control of Operator's Performance Undertaking a Cognitive Task
This paper presents a new modeling and control fuzzy-based framework validated with real-time experiments on human participants experiencing stress via mental arithmetic cognitive tasks identified through psychophysiological markers. The ultimate aim of the modeling/control framework is to prevent performance breakdown in human-computer interactive systems with a special focus on human performance. Two designed modeling/control experiments which consist of carrying-out arithmetic operations of varying difficulty levels were performed by ten participants (operators) in the study. With this new technique, modeling is achieved through a new adaptive, self-organizing, and interpretable modeling framework based on general Type-2 fuzzy sets. This framework is able to learn in real time through the implementation of a restructured performance learning algorithm that identifies important features in the data without the need for prior training. The information learnt by the model is later exploited via an energy model based controller that infers adequate control actions by changing the difficulty level of the arithmetic operations in the human-computer interaction system; these actions being based on the most current psychophysiological state of the subject under study. The real-time implementation of the proposed modeling and control configurations for the human-machine interaction under study shows superior performance as compared to other forms of modeling and control, with minimal intervention in terms of model retraining or parameter retuning to deal with uncertainties, disturbances, and inter/intrasubject parameter variability.
- 1 December 2015
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-7
A new computer control system for mental stress management using fuzzy logic
Mental stress is an important aspect that can, more often than not, affect the humans' performance when they attempt tasks of varying levels of complexity. Indeed, exposing the human to high levels of mental stress which he/she cannot tolerate, may affect the successful completion of the task to be accomplished. Therefore, the need for a system which can monitor the levels of the applied mental stress on human according to his/her current state is of prime importance. Hence, this work introduces a new system that can be used to automatically modify the applied mental stress according to the output of a linguistic model that employs fuzzy sets in the form of Mamdani-type fuzzy rules. This model accepts two markers which were derived based on heart rate and pupil dilation signals and predicts a performance index which is the test accuracy. Consequently, a “crisp” decision is made according to such predicted performance to alter the applied mental stress level. This system is implemented on two personal computers connected through a network; one for applying mental stress (in the form of arithmetic test), while the other is for monitoring the human mental state through the two markers and managing the mental stress levels. The results show a close match between the system's closed loop operation and the actual measurements acquired from human volunteers.
- 1 December 2015
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-7
A new computer control system for mental stress management using fuzzy logic
Mental stress is an important aspect that can, more often than not, affect the humans' performance when they attempt tasks of varying levels of complexity. Indeed, exposing the human to high levels of mental stress which he/she cannot tolerate, may affect the successful completion of the task to be accomplished. Therefore, the need for a system which can monitor the levels of the applied mental stress on human according to his/her current state is of prime importance. Hence, this work introduces a new system that can be used to automatically modify the applied mental stress according to the output of a linguistic model that employs fuzzy sets in the form of Mamdani-type fuzzy rules. This model accepts two markers which were derived based on heart rate and pupil dilation signals and predicts a performance index which is the test accuracy. Consequently, a “crisp” decision is made according to such predicted performance to alter the applied mental stress level. This system is implemented on two personal computers connected through a network; one for applying mental stress (in the form of arithmetic test), while the other is for monitoring the human mental state through the two markers and managing the mental stress levels. The results show a close match between the system's closed loop operation and the actual measurements acquired from human volunteers.
- 1 October 2015
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 286-291
Pupil diameter size marker for incremental mental stress detection
This paper describes a new statistical based study of the pupil diameter marker for the detection of incremental levels of mental stress in operators who are subjected to mental stress. In order to achieve an acceptable and an incremental level of mental stress, the operators were subjected from two to four sessions each of an arithmetic operations based test of varying difficulty. The experiment was performed on 4 healthy subjects of ages varying from 27 to 45 and for a total of 13 experiment sessions. In order to account for the effect of fatigue in the experiment, the order of the difficulty levels was varied for different sessions. The results obtained demonstrate the effectiveness of the pupil diameter marker as a viable incremental predictor of mental stress as inferred from the obtained two-sample statistical t-test.
- 1 October 2015
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 286-291
Pupil diameter size marker for incremental mental stress detection
This paper describes a new statistical based study of the pupil diameter marker for the detection of incremental levels of mental stress in operators who are subjected to mental stress. In order to achieve an acceptable and an incremental level of mental stress, the operators were subjected from two to four sessions each of an arithmetic operations based test of varying difficulty. The experiment was performed on 4 healthy subjects of ages varying from 27 to 45 and for a total of 13 experiment sessions. In order to account for the effect of fatigue in the experiment, the order of the difficulty levels was varied for different sessions. The results obtained demonstrate the effectiveness of the pupil diameter marker as a viable incremental predictor of mental stress as inferred from the obtained two-sample statistical t-test.
- 1 December 2012
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- No. 21566097,p. 179-182
Modeling and simulation of the cardiovascular system for healthy subjects under physical stress
A cardiovascular (CV) model for healthy subjects under physical stress, based on luczak's first and second models, is presented in this paper. An actual (measured) heart rate (HR) and blood pressure (BP) signals for 12 healthy subjects were utilized for model identification. The pattern search method was employed to optimize the model output signals and to estimate the missing parameters. The output of the model was validated in frequency and time domains. Finally, the proposed cardiovascular model was found to be able to simulate the HR and BP signals for subjects under physical stress with a good accuracy and it could be used in medical or sport applications.
- 1 December 2012
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- No. 21566097,p. 179-182
Modeling and simulation of the cardiovascular system for healthy subjects under physical stress
A cardiovascular (CV) model for healthy subjects under physical stress, based on luczak's first and second models, is presented in this paper. An actual (measured) heart rate (HR) and blood pressure (BP) signals for 12 healthy subjects were utilized for model identification. The pattern search method was employed to optimize the model output signals and to estimate the missing parameters. The output of the model was validated in frequency and time domains. Finally, the proposed cardiovascular model was found to be able to simulate the HR and BP signals for subjects under physical stress with a good accuracy and it could be used in medical or sport applications.
- 1 May 2012
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 45-48
An Optimized Cardiovascular Model: A Pattern Search Approach
An optimized model of the cardiovascular system (CVS) based on Luczak's first model, which was developed in 1975, is presented in this paper. This model is characterized by its ability to illustrate most of the interactions within the cardiovascular system. The proposed model consists of three main interacting modules: heart rate (HR), blood pressure (BP), and respiration (RS). The values of the proposed model's parameters, which are 22 parameters, were estimated using different identification techniques to select the best technique. The pattern search approach was selected as the best technique according to the calculated results and all the parameters values were re-calculated using this technique. Furthermore, the selected parameters were identified based on standard clinical data for subjects at rest using the parameter estimation toolbox (Pattern search method) within the environment of Matlab ® . Moreover, a sensitivity analysis was carried out to find the most essential parameters to be used in any further development of the model. The optimized parameters were found to improve the model estimated results for simulating subjects at rest, and can be exploited for simulating subjects experiencing physical stress.
- 1 May 2012
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 45-48
An Optimized Cardiovascular Model: A Pattern Search Approach
An optimized model of the cardiovascular system (CVS) based on Luczak's first model, which was developed in 1975, is presented in this paper. This model is characterized by its ability to illustrate most of the interactions within the cardiovascular system. The proposed model consists of three main interacting modules: heart rate (HR), blood pressure (BP), and respiration (RS). The values of the proposed model's parameters, which are 22 parameters, were estimated using different identification techniques to select the best technique. The pattern search approach was selected as the best technique according to the calculated results and all the parameters values were re-calculated using this technique. Furthermore, the selected parameters were identified based on standard clinical data for subjects at rest using the parameter estimation toolbox (Pattern search method) within the environment of Matlab ® . Moreover, a sensitivity analysis was carried out to find the most essential parameters to be used in any further development of the model. The optimized parameters were found to improve the model estimated results for simulating subjects at rest, and can be exploited for simulating subjects experiencing physical stress.
- 1 October 2011
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- Vol. 3 (19482914) , 1443-1447
A computer-based system for safe physical fitness evaluation
Exercise evaluation is a noninvasive technique to evaluate the condition of any subject's cardiovascular system under physical stress. A System for safe physical fitness evaluation for subjects undergoing aerobic physical stress is presented. This system has been implemented in the form of a graphical user interface in the environment of Matlab ® . Furthermore, the proposed system is designed for young subjects of age below 35 years who undergo physical stress on a Kettler ergoracer bicycle. The subject's body mass index, target heart rate, and maximum heart rate will be calculated before starting the evaluation. A Proportional-Integral (PI) fuzzy controller is applied to control the applied physical stress to ensure not exceeding the predefined target heart rate to satisfy safety. The time of the evaluation procedure is about 4-5 minutes which is divided into: 1) 3-3½ minutes for applying an appropriate physical stress to the subject under test, 2) 1½ minute for recovery and evaluation. Based on the change in the subject's recovery heart rate and taking into account the body mass index, an evaluation for the subject's fitness state is carried out.
- 1 October 2011
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- Vol. 3 (19482914) , 1443-1447
A computer-based system for safe physical fitness evaluation
Exercise evaluation is a noninvasive technique to evaluate the condition of any subject's cardiovascular system under physical stress. A System for safe physical fitness evaluation for subjects undergoing aerobic physical stress is presented. This system has been implemented in the form of a graphical user interface in the environment of Matlab ® . Furthermore, the proposed system is designed for young subjects of age below 35 years who undergo physical stress on a Kettler ergoracer bicycle. The subject's body mass index, target heart rate, and maximum heart rate will be calculated before starting the evaluation. A Proportional-Integral (PI) fuzzy controller is applied to control the applied physical stress to ensure not exceeding the predefined target heart rate to satisfy safety. The time of the evaluation procedure is about 4-5 minutes which is divided into: 1) 3-3½ minutes for applying an appropriate physical stress to the subject under test, 2) 1½ minute for recovery and evaluation. Based on the change in the subject's recovery heart rate and taking into account the body mass index, an evaluation for the subject's fitness state is carried out.
- 1 January 2009
- Published by Springer Nature
- p. 146-149
The Assessment of Heart Rate Variability (HRV) and Task Load Index (TLI) as Physiological Markers for Physical Stress
- 1 January 2009
- Published by Springer Nature
- p. 146-149
The Assessment of Heart Rate Variability (HRV) and Task Load Index (TLI) as Physiological Markers for Physical Stress