Yingbai Xie
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Yingbai Xie has a total of 57 co-authors. Here are the top co-authors by number of shared publications:
Zhun Yu
North China Electric Power University
6 shared publicationsBing Li
North China Electric Power University
4 shared publicationsJiancheng Tang
School of Energy & Power Engineering, North China Electric Power University, Baoding, China
4 shared publicationsChuntao Liu
North China Electric Power University
3 shared publicationsLiyong Lun
North China Electric Power University
3 shared publicationsYun Liu
North China Electric Power University
3 shared publications
Latest Publications
- Open Access
- 1 October 2020
- Published by IOP Publishing in Journal of Physics: Conference Series
- Vol. 1624 (5) , 052021
Prediction of Carbon Content in Fly Ash in Ultra Supercritical Generation Unit with Long Short-term Memory Neural Network
The accurate measurement of carbon content in fly ash is the basis of improving the thermal conversion efficiency of boiler and reducing the coal consumption of power generation. Based on the operation data of 1000MW Ultra-supercritical Unit in a thermal power plant, the input parameters of the model were selected by correlation analysis. The Long Short-Term Memory neural network (LSTM) was used to establish a prediction model with the boiler operation parameters as the input and the carbon content of the boiler fly ash as the output. According to the actual operation data of the unit, the prediction performance of the model was trained and tested. The simulation results show that the average prediction error of the LSTM model is 2.8136%, and 86% of the total samples are data with error less than 4.5%, which means it has high accuracy and strong generalization ability.
- 1 October 2020
- Published by IOP Publishing in Journal of Physics: Conference Series
- Vol. 1624 (5) , 052021
Open AccessPrediction of Carbon Content in Fly Ash in Ultra Supercritical Generation Unit with Long Short-term Memory Neural Network
The accurate measurement of carbon content in fly ash is the basis of improving the thermal conversion efficiency of boiler and reducing the coal consumption of power generation. Based on the operation data of 1000MW Ultra-supercritical Unit in a thermal power plant, the input parameters of the model were selected by correlation analysis. The Long Short-Term Memory neural network (LSTM) was used to establish a prediction model with the boiler operation parameters as the input and the carbon content of the boiler fly ash as the output. According to the actual operation data of the unit, the prediction performance of the model was trained and tested. The simulation results show that the average prediction error of the LSTM model is 2.8136%, and 86% of the total samples are data with error less than 4.5%, which means it has high accuracy and strong generalization ability.
- Open Access
Thermodynamic Analysis on an Integrated Liquefied Air Energy Storage and Electricity Generation System
For an integrated liquefied air energy storage and electricity generation system, mathematical models of the liquefied air energy storage and electricity generation process are established using a thermodynamic theory. The effects of the outlet pressure of the compressor unit, the outlet pressure of the cryogenic pump, the heat exchanger effectiveness, the initial air temperature and pressure before throttling on the performances of the integrated liquefied air energy storage, and the electricity generation system are investigated, using the cycle efficiency and liquid air yield ratio as the evaluation indexes. The results show that if the compressor outlet pressure is raised, both the compression work and the expansion work increase, but because the expansion work increases more slowly, the cycle efficiency of the system gradually decreases. Increasing the cryogenic pump outlet pressure and heat exchanger effectiveness can significantly increase the cycle efficiency of the system; the higher the air pressure and the lower the air temperature before throttling, the greater the liquid air yield after expansion, and the higher the cycle efficiency. The theoretical analysis models and research results can provide a reference for the development of an integrated system of liquefied air energy storage and electricity production, as well as for the development of medium-capacity energy storage technology.
Open AccessThermodynamic Analysis on an Integrated Liquefied Air Energy Storage and Electricity Generation System
For an integrated liquefied air energy storage and electricity generation system, mathematical models of the liquefied air energy storage and electricity generation process are established using a thermodynamic theory. The effects of the outlet pressure of the compressor unit, the outlet pressure of the cryogenic pump, the heat exchanger effectiveness, the initial air temperature and pressure before throttling on the performances of the integrated liquefied air energy storage, and the electricity generation system are investigated, using the cycle efficiency and liquid air yield ratio as the evaluation indexes. The results show that if the compressor outlet pressure is raised, both the compression work and the expansion work increase, but because the expansion work increases more slowly, the cycle efficiency of the system gradually decreases. Increasing the cryogenic pump outlet pressure and heat exchanger effectiveness can significantly increase the cycle efficiency of the system; the higher the air pressure and the lower the air temperature before throttling, the greater the liquid air yield after expansion, and the higher the cycle efficiency. The theoretical analysis models and research results can provide a reference for the development of an integrated system of liquefied air energy storage and electricity production, as well as for the development of medium-capacity energy storage technology.
- Open Access
Investigation on the Performances of Vuilleumier Cycle Heat Pump Adopting Mixture Refrigerants
The performances of thermodynamics cycles are dependent on the properties of refrigerants. The performances of Vuilleumier (VM) cycle heat pump adopting mixture refrigerants are analyzed by MATLAB software using REFPROP programming. At given operating parameters and configuration, performances of the VM cycle adopting pure refrigerant, H2, He or N2 are compared. Thermodynamic properties of the four type mixtures, namely, He-H2, He-N2, H2-N2 and He-H2-N2, are obtained with total 16 mixing ratio, and the coefficient of performance and the exergy efficiency of these four mixture types in VM cycle heat pump are calculated. The results indicate that within the temperature of heat source 400–1000 K, helium is the best choice of pure refrigerant for VM cycle heat pump. The He-H2 mixture is the best among all binary refrigerant mixtures; the recommended proportion is 1:2. For trinary refrigerant mixture, suggested proportion of helium, hydrogen and nitrogen is 2:2:1. For these recommended mixtures, system COPs (coefficient of performances) are close to 3.3 and exergy efficiencies are about 0.2, which are close to pure refrigerant helium.
Open AccessInvestigation on the Performances of Vuilleumier Cycle Heat Pump Adopting Mixture Refrigerants
The performances of thermodynamics cycles are dependent on the properties of refrigerants. The performances of Vuilleumier (VM) cycle heat pump adopting mixture refrigerants are analyzed by MATLAB software using REFPROP programming. At given operating parameters and configuration, performances of the VM cycle adopting pure refrigerant, H2, He or N2 are compared. Thermodynamic properties of the four type mixtures, namely, He-H2, He-N2, H2-N2 and He-H2-N2, are obtained with total 16 mixing ratio, and the coefficient of performance and the exergy efficiency of these four mixture types in VM cycle heat pump are calculated. The results indicate that within the temperature of heat source 400–1000 K, helium is the best choice of pure refrigerant for VM cycle heat pump. The He-H2 mixture is the best among all binary refrigerant mixtures; the recommended proportion is 1:2. For trinary refrigerant mixture, suggested proportion of helium, hydrogen and nitrogen is 2:2:1. For these recommended mixtures, system COPs (coefficient of performances) are close to 3.3 and exergy efficiencies are about 0.2, which are close to pure refrigerant helium.
- Open Access
Thermodynamic Analysis of a Waste Heat Driven Vuilleumier Cycle Heat Pump
A Vuilleumier (VM) cycle heat pump is a closed gas cycle driven by heat energy. It has the highest performance among all known heat driven technologies. In this paper, two thermodynamic analyses, including energy and exergy analysis, are carried out to evaluate the application of a VM cycle heat pump for waste heat utilization. For a prototype VM cycle heat pump, equations for theoretical and actual cycles are established. Under the given conditions, the exergy efficiency for the theoretical cycle is 0.23 compared to 0.15 for the actual cycle. This is due to losses taking place in the actual cycle. Reheat losses and flow friction losses account for almost 83% of the total losses. Investigation of the effect of heat source temperature, cycle pressure and speed on the exergy efficiency indicate that the low temperature waste heat is a suitable heat source for a VM cycle heat pump. The selected cycle pressure should be higher than 100 MPa, and 200–300 rpm is the optimum speed.
Open AccessThermodynamic Analysis of a Waste Heat Driven Vuilleumier Cycle Heat Pump
A Vuilleumier (VM) cycle heat pump is a closed gas cycle driven by heat energy. It has the highest performance among all known heat driven technologies. In this paper, two thermodynamic analyses, including energy and exergy analysis, are carried out to evaluate the application of a VM cycle heat pump for waste heat utilization. For a prototype VM cycle heat pump, equations for theoretical and actual cycles are established. Under the given conditions, the exergy efficiency for the theoretical cycle is 0.23 compared to 0.15 for the actual cycle. This is due to losses taking place in the actual cycle. Reheat losses and flow friction losses account for almost 83% of the total losses. Investigation of the effect of heat source temperature, cycle pressure and speed on the exergy efficiency indicate that the low temperature waste heat is a suitable heat source for a VM cycle heat pump. The selected cycle pressure should be higher than 100 MPa, and 200–300 rpm is the optimum speed.
- 1 August 2014
- Published by Trans Tech Publications, Ltd. in Advanced Materials Research
- Vol. 1008-1009, 1080-1083
Fuzzy Comprehensive Evaluation of System Performance for Vuilleumier Cycle Heat Pump Driven by Solar, Geo-Thermal and Biomass Energy
Vuilleumier cycle heat pump (VM) has highest efficiency among all heat driven cycle. In this paper, solar, geo-thermal and biomass energy are investigated as input thermal energy to driven VM cycle heat pump. Fuzzy comprehensive evaluation method is applied to evaluate system performances. Initial investment of the system (IS), system reliability (RS), environmental protection of system (EP), VM exergy efficiency (EE) and VM coefficient of performance (COP) are selected as main evaluation indexes. For all the three renewable input energy, system are scored good, solar driven is better than the other two.
- 1 August 2014
- Published by Trans Tech Publications, Ltd. in Advanced Materials Research
- Vol. 1008-1009, 1080-1083
Fuzzy Comprehensive Evaluation of System Performance for Vuilleumier Cycle Heat Pump Driven by Solar, Geo-Thermal and Biomass Energy
Vuilleumier cycle heat pump (VM) has highest efficiency among all heat driven cycle. In this paper, solar, geo-thermal and biomass energy are investigated as input thermal energy to driven VM cycle heat pump. Fuzzy comprehensive evaluation method is applied to evaluate system performances. Initial investment of the system (IS), system reliability (RS), environmental protection of system (EP), VM exergy efficiency (EE) and VM coefficient of performance (COP) are selected as main evaluation indexes. For all the three renewable input energy, system are scored good, solar driven is better than the other two.
- 1 August 2014
- Published by Trans Tech Publications, Ltd. in Advanced Materials Research
- Vol. 1008-1009, 1084-1087
Research on the Region Division for Supercritical CO2 Cooling Heat Transfer in Gas Cooler
In gas cooler, a key component of transcritical heat pump system, CO2 is always in supercritical status. A well design gas cooler should get the full informations of supercritcal CO2 in-tube cooling heat transfer characteristic. An EES program is developed to calculate the supercritical CO2 cooling heat transfer performances based on 4 selected correlation equations. According to the results and the thermopgysical parameters of supercritical CO2, such as specific heat, density, thermal conductivity and dynamic viscosity, two region, the starting area of supercritical region and the main supercritical region, is suggested for supercritical CO2 cooling heat transfer by temperature at 80°C. In the staring area, the variations of heat transfer and other parameters are intensive, while in the main supercritical region, the variations are clined to be stable.
- 1 August 2014
- Published by Trans Tech Publications, Ltd. in Advanced Materials Research
- Vol. 1008-1009, 1084-1087
Research on the Region Division for Supercritical CO2 Cooling Heat Transfer in Gas Cooler
In gas cooler, a key component of transcritical heat pump system, CO2 is always in supercritical status. A well design gas cooler should get the full informations of supercritcal CO2 in-tube cooling heat transfer characteristic. An EES program is developed to calculate the supercritical CO2 cooling heat transfer performances based on 4 selected correlation equations. According to the results and the thermopgysical parameters of supercritical CO2, such as specific heat, density, thermal conductivity and dynamic viscosity, two region, the starting area of supercritical region and the main supercritical region, is suggested for supercritical CO2 cooling heat transfer by temperature at 80°C. In the staring area, the variations of heat transfer and other parameters are intensive, while in the main supercritical region, the variations are clined to be stable.
- 1 January 2012
- Published by Trans Tech Publications, Ltd. in Advanced Materials Research
- Vol. 455-456, 252-257
Thermodynamic Analysis of Solar Driven Vuilleumier Cycle Heat Pump
Because the refrigerant can cause serious damage to the ozone layer and form the greenhouse effect, developing green environmental protection refrigeration technology has become a consensus. Based on the view, this paper puts forward a new device called the solar energy driven VM cycle heat pump which used the natural working materials—nitrogen as the refrigerant and the clean energy—solar as the driven energy. According to build the thermodynamic model, the influence of heat source temperature on the ideal cycle has been analysed. And COP of the solar driven the VM cycle heat pump will be received. With the city of Beijing, for example, the device refrigeration COP can reach at least 1.4.
- 1 January 2012
- Published by Trans Tech Publications, Ltd. in Advanced Materials Research
- Vol. 455-456, 252-257
Thermodynamic Analysis of Solar Driven Vuilleumier Cycle Heat Pump
Because the refrigerant can cause serious damage to the ozone layer and form the greenhouse effect, developing green environmental protection refrigeration technology has become a consensus. Based on the view, this paper puts forward a new device called the solar energy driven VM cycle heat pump which used the natural working materials—nitrogen as the refrigerant and the clean energy—solar as the driven energy. According to build the thermodynamic model, the influence of heat source temperature on the ideal cycle has been analysed. And COP of the solar driven the VM cycle heat pump will be received. With the city of Beijing, for example, the device refrigeration COP can reach at least 1.4.
- 1 January 2012
- Published by Trans Tech Publications, Ltd. in Advanced Materials Research
- Vol. 455-456, 240-245
The Experimental Investigation and Theoretical Analysis on Transcritical Carbon Dioxide Heat Pump Cycle
The (H)CFC-phase out and the fear for future problems for other synthetic working fluids, because of their known and unknown impact on the environment, have introduced a rising interest in environmentally safe natural working fluids. CO2 is one of the few non-toxic and non-flammable working fluids that do not contribute to ozone depletion or global warming, if leaked to the atmosphere. Because the critical temperature of CO2 is only 31.1°C, the transcritical cycle can be used to improve the coefficient of performance of the system. The experimental investigation and theoretical analysis on transcritical carbon dioxide heat pump system are carried out in this paper. It points out that there is an optimum operational pressure on transcritical carbon dioxide heat pump cycle, when the outlet temperature of gas cooler is constant, the coefficient of performance increases with increasing evaporating temperature at the same conditions, and the operational efficiency increased with decrease of gas cooler exit temperature. So in order to obtain the optimum performance, the influence of evaporating temperature, gas cooler exit temperature, and the operational pressure should be considered during the designing and operating transcritical carbon dioxide heat pump system.
- 1 January 2012
- Published by Trans Tech Publications, Ltd. in Advanced Materials Research
- Vol. 455-456, 240-245
The Experimental Investigation and Theoretical Analysis on Transcritical Carbon Dioxide Heat Pump Cycle
The (H)CFC-phase out and the fear for future problems for other synthetic working fluids, because of their known and unknown impact on the environment, have introduced a rising interest in environmentally safe natural working fluids. CO2 is one of the few non-toxic and non-flammable working fluids that do not contribute to ozone depletion or global warming, if leaked to the atmosphere. Because the critical temperature of CO2 is only 31.1°C, the transcritical cycle can be used to improve the coefficient of performance of the system. The experimental investigation and theoretical analysis on transcritical carbon dioxide heat pump system are carried out in this paper. It points out that there is an optimum operational pressure on transcritical carbon dioxide heat pump cycle, when the outlet temperature of gas cooler is constant, the coefficient of performance increases with increasing evaporating temperature at the same conditions, and the operational efficiency increased with decrease of gas cooler exit temperature. So in order to obtain the optimum performance, the influence of evaporating temperature, gas cooler exit temperature, and the operational pressure should be considered during the designing and operating transcritical carbon dioxide heat pump system.
- 1 January 2012
- Published by Trans Tech Publications, Ltd. in Advanced Materials Research
- Vol. 455-456, 1102-1108
Fuzzy Comprehensive Evaluation of Performance of the Natural Gas Driven Vuilleumier Cycle Heat Pump
. In order to research the overall performance of the natural gas driven Vuilleumier (VM) cycle heat pump deeply, we adopt the fuzzy mathematical theory, the fuzzy comprehensive evaluation of performance of the natural gas driven VM cycle heat pump has been discussed in this paper from five aspects: technology, economy, safety, maintainability and environmental protection. Combine fuzzy comprehensive evaluation with performance study of the natural gas driven VM cycle heat pump; it is a effective way to improve scientific of the comprehensive evaluation and the reliability of the results.
- 1 January 2012
- Published by Trans Tech Publications, Ltd. in Advanced Materials Research
- Vol. 455-456, 1102-1108
Fuzzy Comprehensive Evaluation of Performance of the Natural Gas Driven Vuilleumier Cycle Heat Pump
. In order to research the overall performance of the natural gas driven Vuilleumier (VM) cycle heat pump deeply, we adopt the fuzzy mathematical theory, the fuzzy comprehensive evaluation of performance of the natural gas driven VM cycle heat pump has been discussed in this paper from five aspects: technology, economy, safety, maintainability and environmental protection. Combine fuzzy comprehensive evaluation with performance study of the natural gas driven VM cycle heat pump; it is a effective way to improve scientific of the comprehensive evaluation and the reliability of the results.
- 1 July 2011
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1173-1175
Design of an experimental system for cryogenic compact exchanger
Heat exchanger is one of the most important devices in thermal system. An experimental system is developed for testing the heat-exchange performance of cryogenic compact exchangers. This system mainly consists of a regenerator, a cold box, a liquid nitrogen dewar, two cryogenic transfer lines and other devices. The features of the main components are described in this paper. A measurement system based on PC is developed for this system. All of these make this system more reliable, convenient, and energy-saving.
- 1 July 2011
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1173-1175
Design of an experimental system for cryogenic compact exchanger
Heat exchanger is one of the most important devices in thermal system. An experimental system is developed for testing the heat-exchange performance of cryogenic compact exchangers. This system mainly consists of a regenerator, a cold box, a liquid nitrogen dewar, two cryogenic transfer lines and other devices. The features of the main components are described in this paper. A measurement system based on PC is developed for this system. All of these make this system more reliable, convenient, and energy-saving.