Łukasz Macioszek
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Łukasz Macioszek has a total of 15 co-authors. Here are the top co-authors by number of shared publications:
Ryszard Rybski
Univ Zielona Gora, Inst Metrol Elect & Comp Sci, Ul Prof Z Szafrana 2, PL-65246 Zielona Gora, Poland
3 shared publications- Ryszard Rybski
Institute of Metrology, Electronics and Computer Science, University of Zielona Góra, 65-417 Zielona Góra, Poland
3 shared publications - Dariusz Sobczyński
Dept. of Power Electronics and Power Engineering, Rzeszow University of Technology, Rzeszow, Poland
2 shared publications Sylwia Włodarczak
Poznan University of Technology
2 shared publications- Jakub Kostecki
Institute of Environmental Engineering, University of Zielona Góra, 65-417 Zielona Góra, Poland
1 shared publication Joanna Urbaniak
Uniwersytet Zielonogorski, Inst Nauk Biol, Ul Prof Z Szafrana 1, PL-65516 Zielona Gora, Poland
1 shared publication
Latest Publications
- Open Access
- 31 December 2025
- Published by Polish Academy of Sciences Chancellery in Metrology and Measurement Systems
- p. 1-14
Distributed measurement system for beer electrochemical properties monitoring
Monitoring the properties of beer at the production stage is one of the key factors affecting the quality of the final product. The chemical composition, the reactions that take place, and the microorganisms that enable its production change the electrochemical properties of beer. Therefore, monitoring them on an ongoing basis can contribute to increasing convenience and certainty as to the correctness of the entire process. One of the methods that allows measurements of the electrical properties of matter in situ is impedance spectroscopy. To support beer production, especially in craft breweries, an attempt was made to design, launch, and test a system that is highly scalable and universal, as it can be used both for measurements and process control. The Distributed Measurement System presented in the article fulfils all the aforementioned conditions. The laboratory measurement results were compared with those obtained by using a specialised system for electrochemical impedance spectroscopy.
- 31 December 2025
- Published by Polish Academy of Sciences Chancellery in Metrology and Measurement Systems
- p. 1-14
Open AccessDistributed measurement system for beer electrochemical properties monitoring
Monitoring the properties of beer at the production stage is one of the key factors affecting the quality of the final product. The chemical composition, the reactions that take place, and the microorganisms that enable its production change the electrochemical properties of beer. Therefore, monitoring them on an ongoing basis can contribute to increasing convenience and certainty as to the correctness of the entire process. One of the methods that allows measurements of the electrical properties of matter in situ is impedance spectroscopy. To support beer production, especially in craft breweries, an attempt was made to design, launch, and test a system that is highly scalable and universal, as it can be used both for measurements and process control. The Distributed Measurement System presented in the article fulfils all the aforementioned conditions. The laboratory measurement results were compared with those obtained by using a specialised system for electrochemical impedance spectroscopy.
- 6 December 2024
- Published by Wydawnictwo SIGMA-NOT, sp. z.o.o. in PRZEGLĄD ELEKTROTECHNICZNY
- Vol. 1 (12) , 139-142
Spektroskopia impedancyjna wybranych elektrochemicznych źródeł napięcia
Elektrochemiczne źródła napięcia stały się powszechnym elementem życia codziennego. Dla zachowania ich wysokiej sprawności i bezawaryjnej pracy, bardzo ważne jest monitorowanie bieżącego stanu źródeł. Metoda spektroskopii impedancyjnej umożliwia między innymi oszacowanie rezystancji wewnętrznej badanego źródła. W pracy podjęto próbę przeglądu możliwości oraz ograniczeń stosowania spektroskopii impedancyjnej w badaniach wybranych źródeł elektrochemicznych.
- 6 December 2024
- Published by Wydawnictwo SIGMA-NOT, sp. z.o.o. in PRZEGLĄD ELEKTROTECHNICZNY
- Vol. 1 (12) , 139-142
Spektroskopia impedancyjna wybranych elektrochemicznych źródeł napięcia
Elektrochemiczne źródła napięcia stały się powszechnym elementem życia codziennego. Dla zachowania ich wysokiej sprawności i bezawaryjnej pracy, bardzo ważne jest monitorowanie bieżącego stanu źródeł. Metoda spektroskopii impedancyjnej umożliwia między innymi oszacowanie rezystancji wewnętrznej badanego źródła. W pracy podjęto próbę przeglądu możliwości oraz ograniczeń stosowania spektroskopii impedancyjnej w badaniach wybranych źródeł elektrochemicznych.
- Open Access
Moisture Content Assessment of Commercially Available Diesel Fuel Using Impedance Spectroscopy
Diesel is consistently a very popular fuel for internal combustion engines. Its consumption in the European Union has been rising over recent years, as has the number of engines increasingly sensitive to fuel contamination. One of the most important parameters affecting diesel quality is water content. Its exceedance of the standard’s permissible amount carries the risk of serious damage to expensive, modern fuel injection systems. Current methods of measuring water content require both specialised personnel and equipment, as well as transporting the sample to a suitable laboratory. Analysing the properties of diesel is challenging, mainly because many types of the fuel are sold, the chemical composition of which is always a well-guarded manufacturer’s secret. The research presented in this paper is aimed at verifying whether it is possible to test the moisture content of diesel using impedance spectroscopy. To date, it is the first such attempt with commercially available diesel using this method, which, once refined, could be used in situ. The authors propose and apply a novel technique that is able to be used when the electrical properties of tested oils are unknown. The experimental results obtained show that it is possible to use impedance spectroscopy to estimate the water content of different types of diesel fuel. The measurement accuracy achieved makes it possible to detect approaching or exceeding the permissible water content.
Open AccessMoisture Content Assessment of Commercially Available Diesel Fuel Using Impedance Spectroscopy
Diesel is consistently a very popular fuel for internal combustion engines. Its consumption in the European Union has been rising over recent years, as has the number of engines increasingly sensitive to fuel contamination. One of the most important parameters affecting diesel quality is water content. Its exceedance of the standard’s permissible amount carries the risk of serious damage to expensive, modern fuel injection systems. Current methods of measuring water content require both specialised personnel and equipment, as well as transporting the sample to a suitable laboratory. Analysing the properties of diesel is challenging, mainly because many types of the fuel are sold, the chemical composition of which is always a well-guarded manufacturer’s secret. The research presented in this paper is aimed at verifying whether it is possible to test the moisture content of diesel using impedance spectroscopy. To date, it is the first such attempt with commercially available diesel using this method, which, once refined, could be used in situ. The authors propose and apply a novel technique that is able to be used when the electrical properties of tested oils are unknown. The experimental results obtained show that it is possible to use impedance spectroscopy to estimate the water content of different types of diesel fuel. The measurement accuracy achieved makes it possible to detect approaching or exceeding the permissible water content.
- Open Access
- 27 March 2024
- Published by MDPI AG in Preprints.org
Moisture Content Assessment of Commercially Available Diesel Fuel Using Impedance Spectroscopy
Diesel is consistently a very popular fuel for internal combustion engines. Its consumption in the European Union has been rising over recent years, as has the number of engines increasingly sensitive to fuel contamination. One of the most important parameters affecting diesel quality is water content. Although its exceedances of the standard’s permissible amount are not common, they carry the risk of serious damage to expensive, modern fuel injection systems. Current methods of measuring water content require both specialised personnel and equipment, as well as transporting the sample to a suitable laboratory. The research presented in this paper was aimed at verifying whether it would be possible to test the moisture content of diesel using impedance spectroscopy. Once refined, such measurement method could be used in situ. Analysing the properties of diesel is challenging, mainly because many types of the fuel are sold, the chemical composition of which is always a well-guarded manufacturer’s secret. The experimental results obtained on many types of commercially available diesel show that it is possible to use impedance spectroscopy to estimate the water content of different types of diesel fuel. The measurement accuracy achieved makes it possible to detect approaching or exceeding the permissible water content.
- 27 March 2024
- Published by MDPI AG in Preprints.org
Open AccessMoisture Content Assessment of Commercially Available Diesel Fuel Using Impedance Spectroscopy
Diesel is consistently a very popular fuel for internal combustion engines. Its consumption in the European Union has been rising over recent years, as has the number of engines increasingly sensitive to fuel contamination. One of the most important parameters affecting diesel quality is water content. Although its exceedances of the standard’s permissible amount are not common, they carry the risk of serious damage to expensive, modern fuel injection systems. Current methods of measuring water content require both specialised personnel and equipment, as well as transporting the sample to a suitable laboratory. The research presented in this paper was aimed at verifying whether it would be possible to test the moisture content of diesel using impedance spectroscopy. Once refined, such measurement method could be used in situ. Analysing the properties of diesel is challenging, mainly because many types of the fuel are sold, the chemical composition of which is always a well-guarded manufacturer’s secret. The experimental results obtained on many types of commercially available diesel show that it is possible to use impedance spectroscopy to estimate the water content of different types of diesel fuel. The measurement accuracy achieved makes it possible to detect approaching or exceeding the permissible water content.
- 6 November 2023
- Published by Polish Academy of Sciences Chancellery in Chemical and Process Engineering: New Frontiers
- Vol. 43 (4) , 461-469
Impedance spectroscopy method used for the unpasteurized beer microbiological contamination degree assessment
- 6 November 2023
- Published by Polish Academy of Sciences Chancellery in Chemical and Process Engineering: New Frontiers
- Vol. 43 (4) , 461-469
Impedance spectroscopy method used for the unpasteurized beer microbiological contamination degree assessment
- 11 November 2022
- Published by Wydawnictwo SIGMA-NOT, sp. z.o.o. in PRZEGLĄD ELEKTROTECHNICZNY
- Vol. 1 (11) , 149-152
Zmodyfikowana metoda impedymetryczna w ocenie zanieczyszczeń mikrobiologicznych piwa niepasteryzowanego
Zanieczyszczenie mikrobiologiczne piwa skutkuje pojawieniem się szeregu wad produktu. Celem niniejszej pracy było zastosowanie spektroskopii impedancyjnej w ocenie stopnia zanieczyszczenia mikrobiologicznego w produkcji piwa niepasteryzowanego. Uzyskane wyniki wskazują, że pomiary impedancji mogą być szybką metodą oceny stopnia zanieczyszczenia.
- 11 November 2022
- Published by Wydawnictwo SIGMA-NOT, sp. z.o.o. in PRZEGLĄD ELEKTROTECHNICZNY
- Vol. 1 (11) , 149-152
Zmodyfikowana metoda impedymetryczna w ocenie zanieczyszczeń mikrobiologicznych piwa niepasteryzowanego
Zanieczyszczenie mikrobiologiczne piwa skutkuje pojawieniem się szeregu wad produktu. Celem niniejszej pracy było zastosowanie spektroskopii impedancyjnej w ocenie stopnia zanieczyszczenia mikrobiologicznego w produkcji piwa niepasteryzowanego. Uzyskane wyniki wskazują, że pomiary impedancji mogą być szybką metodą oceny stopnia zanieczyszczenia.
- 1 January 2022
- Published by Wydawnictwo SIGMA-NOT, sp. z.o.o. in PRZEGLĄD ELEKTROTECHNICZNY
- Vol. 98 (11) , 169-172
Concept and implementation of the measurement system for the Odra river flood embankment remote state monitoring
The article presents the architecture of proposed and implemented measurement system for collecting and presenting current information on the flood embankment condition. The system periodically collects data from sensors connected to the data logger, which are finally sent to the server. Based on the analysis of collected measurements, the condition of the flood embankment can be assessed, and in the case of any irregularities, the system can generate appropriate alarms.
- 1 January 2022
- Published by Wydawnictwo SIGMA-NOT, sp. z.o.o. in PRZEGLĄD ELEKTROTECHNICZNY
- Vol. 98 (11) , 169-172
Concept and implementation of the measurement system for the Odra river flood embankment remote state monitoring
The article presents the architecture of proposed and implemented measurement system for collecting and presenting current information on the flood embankment condition. The system periodically collects data from sensors connected to the data logger, which are finally sent to the server. Based on the analysis of collected measurements, the condition of the flood embankment can be assessed, and in the case of any irregularities, the system can generate appropriate alarms.
- 9 May 2020
- Published by Springer Nature
- p. 223-230
Verification of the Impedance Spectroscopy Method Used in Extra Virgin Olive Oil Water Content Assessment
- 9 May 2020
- Published by Springer Nature
- p. 223-230
Verification of the Impedance Spectroscopy Method Used in Extra Virgin Olive Oil Water Content Assessment
- Open Access
- 1 October 2019
- Published by Institution of Engineering and Technology (IET) in IET Science, Measurement & Technology
- Vol. 13 (8) , 1158-1162
Mineral oil moisture measurement with the use of impedance spectroscopy
In this study, an attempt was made to evaluate very small water content (below 0.05% in volume) in the ‘20–30’ mineral oil using both electrochemical impedance spectroscopy (EIS) and dielectric constant calculation based on the measured impedance values. Measurements were performed with the use of laboratory EIS system and were designed to verify experimentally that it is possible to develop an IS‐based measuring system that would be able to work in situ, be relatively cheap and fast alternative compared with systems widely used nowadays. Known amounts of water were added to the oil samples, which were not treated by any other factors, e.g. solvents, contrary to other researchers’ findings. Impedance of the samples was measured in the frequency range of 0.01–100 Hz. Equivalent circuit was proposed and used to reveal how electric properties of the oil change due to water addition. Both calibration curves based on the value of an equivalent circuit element and dielectric constant showed linear correlation of their values with the water amount. Thus, experimental results confirm that with some discussed limitations, EIS and dielectric constant calculation can be used to estimate even such small quantities of water in mineral oil.
- 1 October 2019
- Published by Institution of Engineering and Technology (IET) in IET Science, Measurement & Technology
- Vol. 13 (8) , 1158-1162
Open AccessMineral oil moisture measurement with the use of impedance spectroscopy
In this study, an attempt was made to evaluate very small water content (below 0.05% in volume) in the ‘20–30’ mineral oil using both electrochemical impedance spectroscopy (EIS) and dielectric constant calculation based on the measured impedance values. Measurements were performed with the use of laboratory EIS system and were designed to verify experimentally that it is possible to develop an IS‐based measuring system that would be able to work in situ, be relatively cheap and fast alternative compared with systems widely used nowadays. Known amounts of water were added to the oil samples, which were not treated by any other factors, e.g. solvents, contrary to other researchers’ findings. Impedance of the samples was measured in the frequency range of 0.01–100 Hz. Equivalent circuit was proposed and used to reveal how electric properties of the oil change due to water addition. Both calibration curves based on the value of an equivalent circuit element and dielectric constant showed linear correlation of their values with the water amount. Thus, experimental results confirm that with some discussed limitations, EIS and dielectric constant calculation can be used to estimate even such small quantities of water in mineral oil.
- 5 December 2018
- Published by Wydawnictwo SIGMA-NOT, sp. z.o.o. in PRZEGLĄD ELEKTROTECHNICZNY
- Vol. 1 (12) , 62-65
Zastosowanie metody spektroskopii impedancyjnej do szacowania bardzo małych zawartości wody w oleju mineralnym typu 20-70
Wydawnictwo SIGMA-NOT wydaje czasopisma fachowe informuj?ce swoich czytelnik?w o najnowszych osi?gni?ciach naukowych i nowoczesnych rozwi?zaniach technicznych w Polsce i na ?wiecie, popularyzuje problemy techniczne oraz poszerza wiedz? i kultur? techniczn?.
- 5 December 2018
- Published by Wydawnictwo SIGMA-NOT, sp. z.o.o. in PRZEGLĄD ELEKTROTECHNICZNY
- Vol. 1 (12) , 62-65
Zastosowanie metody spektroskopii impedancyjnej do szacowania bardzo małych zawartości wody w oleju mineralnym typu 20-70
Wydawnictwo SIGMA-NOT wydaje czasopisma fachowe informuj?ce swoich czytelnik?w o najnowszych osi?gni?ciach naukowych i nowoczesnych rozwi?zaniach technicznych w Polsce i na ?wiecie, popularyzuje problemy techniczne oraz poszerza wiedz? i kultur? techniczn?.