Alina Aulet
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Alina Aulet has a total of 25 co-authors. Here are the top co-authors by number of shared publications:
E. Moreno
Instituto de Cibernética Departamento de Ultrasónica Matemática y Física, Calle 15 No. 551, e/ C y D. Vedado, CP 10400, Cuba
3 shared publications- Ismael Núñez
Universidad de la República Laboratorio de Acústica Ultrasonora, Instituto de Física, Facultad de Ciencias Iguá 4225, esq. Mataojo CC 10773, Montevideo 11400, Uruguay
3 shared publications C. Negreira
Laboratorio de Acústica Ultrasonora , Instituto de Física, Facultad de Ciencias-Igua 4225 , Montevideo , 11400 , Uruguay
2 shared publicationsC.A. Negreira
2 shared publicationsH. Calas
Instituto de Cibernética, Matemática y Física , Cuba
2 shared publicationsJ. A. Eiras
UFSCar Departamento de Física, Grupo de Cerámicas Ferroeléctricas Rod. Washington Luis km 235, 13.565-905 San Carlos, São Paulo, Brazil
2 shared publications
Latest Publications
- 1 May 2010
- Published by Acoustical Society of America (ASA) in The Journal of the Acoustical Society of America
- Vol. 127 (5) , 2737-2740
Design and acoustic characterization of limited diffraction ultrasonic devices
Limited diffraction ultrasonic transducers are devices that have a large depth of acoustic field without important effects of diffraction, which make them optimal in applications of medical images, among others. This report details how this special type of piezoelectric device was designed by means of a simple technology using three electrodes in the form of concentric rings in both faces of a ferroelectric ceramic disk, which were used to apply a profile of non-homogeneous polarization. Once designed, the radiation fields emitted by these resonators were characterized experimentally by electro-acoustic and acousto-optic techniques and were compared with those emitted by conventional devices. As shown in the experimental characterizations, ultrasonic transducers with optimal properties for use in medical applications such as good collimation of the ultrasound beam, high lateral resolution, as well as little effects of diffraction were obtained. (C) 2010 Acoustical Society of America. [DOI: 10.1121/1.3337231]
- 1 May 2010
- Published by Acoustical Society of America (ASA) in The Journal of the Acoustical Society of America
- Vol. 127 (5) , 2737-2740
Design and acoustic characterization of limited diffraction ultrasonic devices
Limited diffraction ultrasonic transducers are devices that have a large depth of acoustic field without important effects of diffraction, which make them optimal in applications of medical images, among others. This report details how this special type of piezoelectric device was designed by means of a simple technology using three electrodes in the form of concentric rings in both faces of a ferroelectric ceramic disk, which were used to apply a profile of non-homogeneous polarization. Once designed, the radiation fields emitted by these resonators were characterized experimentally by electro-acoustic and acousto-optic techniques and were compared with those emitted by conventional devices. As shown in the experimental characterizations, ultrasonic transducers with optimal properties for use in medical applications such as good collimation of the ultrasound beam, high lateral resolution, as well as little effects of diffraction were obtained. (C) 2010 Acoustical Society of America. [DOI: 10.1121/1.3337231]
- Open Access
- 1 January 2010
- Published by Elsevier in Physics Procedia
- Vol. 3 (1) , 577-583
Modeling, design and characterization of limited diffraction ultrasonic transducers
- 1 January 2010
- Published by Elsevier in Physics Procedia
- Vol. 3 (1) , 577-583
Open AccessModeling, design and characterization of limited diffraction ultrasonic transducers
- 12 August 2009
- Published by Taylor & Francis in Ferroelectrics
- Vol. 386 (1) , 1-13
Design, Manufacture and Characterization of Ultrasonic Transducers
Piezoelectric transducers are key elements in ultrasound systems used in applications such imaging and flaw detection in non-destructive testing (NDT). NDT intend the analysis of materials and components without affecting their properties, leaving them suitable for their later use, which constitutes actually a valuable tool of engineering. In the present work it was successfully manufactured and characterized a piezoelectric transducer for NDT. The active element of the transducer was a PZT ceramic prepared by the conventional method of solid state reaction. Dielectric, piezoelectric, mechanical and acoustic properties were determined. The transducer was characterized by both electroacoustic and optoacoustic methods.
- 12 August 2009
- Published by Taylor & Francis in Ferroelectrics
- Vol. 386 (1) , 1-13
Design, Manufacture and Characterization of Ultrasonic Transducers
Piezoelectric transducers are key elements in ultrasound systems used in applications such imaging and flaw detection in non-destructive testing (NDT). NDT intend the analysis of materials and components without affecting their properties, leaving them suitable for their later use, which constitutes actually a valuable tool of engineering. In the present work it was successfully manufactured and characterized a piezoelectric transducer for NDT. The active element of the transducer was a PZT ceramic prepared by the conventional method of solid state reaction. Dielectric, piezoelectric, mechanical and acoustic properties were determined. The transducer was characterized by both electroacoustic and optoacoustic methods.
- 31 May 2006
- Published by IOP Publishing in Smart Materials and Structures
- Vol. 15 (4) , 904-908
Non-uniformly polarized piezoelectric modal transducer: fabrication method and experimental results
- 31 May 2006
- Published by IOP Publishing in Smart Materials and Structures
- Vol. 15 (4) , 904-908
Non-uniformly polarized piezoelectric modal transducer: fabrication method and experimental results
- 1 May 2006
- Published by Taylor & Francis in Ferroelectrics
- Vol. 333 (1) , 131-137
Electrical and Acoustical Characterization of the Bessel Transducers
Ultrasonic Bessel transducers produce limited diffraction beams which make them optimal for medical images applications. They satisfy the condition of improved lateral resolution and large depth penetration of the generated ultrasonic field. In this work Bessel transducers using conventional ceramic disks were constructed following a direct poling method, with a center frequency of 2 MHz. The piezoelectric elements contain three concentric electrode rings, which were poled following a Bessel function. Transducers were backed with low impedance and matched to water with a front matching layer for characterizations. The mechanical vibration characteristics of these transducers were investigated through the analysis of electric impedance measurements of their radial and thickness vibration modes. The experimental results were compared with the simulations made by the finite element method (FEM). The experimental resonance frequencies of the Bessel transducer are in agreement with the FEM simulated results in the low and high frequency range. For Bessel transducers, results show that some mechanical resonant modes (i.e. radial fundamental and several harmonics modes) are suppressed when an in phased excitation of the rings is applied. That is not the case for uniformly poled disk.
- 1 May 2006
- Published by Taylor & Francis in Ferroelectrics
- Vol. 333 (1) , 131-137
Electrical and Acoustical Characterization of the Bessel Transducers
Ultrasonic Bessel transducers produce limited diffraction beams which make them optimal for medical images applications. They satisfy the condition of improved lateral resolution and large depth penetration of the generated ultrasonic field. In this work Bessel transducers using conventional ceramic disks were constructed following a direct poling method, with a center frequency of 2 MHz. The piezoelectric elements contain three concentric electrode rings, which were poled following a Bessel function. Transducers were backed with low impedance and matched to water with a front matching layer for characterizations. The mechanical vibration characteristics of these transducers were investigated through the analysis of electric impedance measurements of their radial and thickness vibration modes. The experimental results were compared with the simulations made by the finite element method (FEM). The experimental resonance frequencies of the Bessel transducer are in agreement with the FEM simulated results in the low and high frequency range. For Bessel transducers, results show that some mechanical resonant modes (i.e. radial fundamental and several harmonics modes) are suppressed when an in phased excitation of the rings is applied. That is not the case for uniformly poled disk.
- 1 May 2006
- Published by Taylor & Francis in Ferroelectrics
- Vol. 333 (1) , 107-113
Fast Reconstruction of the Ultrasonic Bessel Transducer Field by Using Schlieren Techniques
Ultrasonic transducers uniformly poled have been used for clinical diagnostic applications, and usually medical imaging use focused beams that present a short depth of ultrasonic field. With ultrasonic transducers that produce limited diffraction beams (Bessel transducers), high-resolution images can be achieved over a large depth of field compared with the focused beams. In this paper we use the Schlieren method in order to obtain a 2-dimensional image of the acoustic field. By assuming axi-symmetrical proprieties of the field, we develop a fast algorithm that allows as reconstructing the 3-dimensional field of acoustical power. We compare its diffraction field with one emitted by a piston-like transducer with the same diameter and excited with the same frequency. We see that the diffraction effect in the last transducer produces a power spread greater than the Bessel one.
- 1 May 2006
- Published by Taylor & Francis in Ferroelectrics
- Vol. 333 (1) , 107-113
Fast Reconstruction of the Ultrasonic Bessel Transducer Field by Using Schlieren Techniques
Ultrasonic transducers uniformly poled have been used for clinical diagnostic applications, and usually medical imaging use focused beams that present a short depth of ultrasonic field. With ultrasonic transducers that produce limited diffraction beams (Bessel transducers), high-resolution images can be achieved over a large depth of field compared with the focused beams. In this paper we use the Schlieren method in order to obtain a 2-dimensional image of the acoustic field. By assuming axi-symmetrical proprieties of the field, we develop a fast algorithm that allows as reconstructing the 3-dimensional field of acoustical power. We compare its diffraction field with one emitted by a piston-like transducer with the same diameter and excited with the same frequency. We see that the diffraction effect in the last transducer produces a power spread greater than the Bessel one.
- 9 July 2004
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- Vol. 2, 1314-1317
Vibration modes in ultrasonic bessel transducer
Diagnosis ultrasonic transducers with uniformly poled can not satisfy the condition of improved lateral resolution and a large depth of the generated ultrasonic field. Bessel transducers appear as a good alternative to improve simultaneously both requirements. In this work a 2 MHz circular Bessel transducer was constructed with three concentric electrode rings, which were poled following a Bessel function. The results show a well focused beam and a depth of field as large as /spl sim/20 times the beam width (6 dB). Moreover, it is verified that the fundamental and some harmonic of the radial mode are suppressed, under an in phase excitation of the rings.
- 9 July 2004
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- Vol. 2, 1314-1317
Vibration modes in ultrasonic bessel transducer
Diagnosis ultrasonic transducers with uniformly poled can not satisfy the condition of improved lateral resolution and a large depth of the generated ultrasonic field. Bessel transducers appear as a good alternative to improve simultaneously both requirements. In this work a 2 MHz circular Bessel transducer was constructed with three concentric electrode rings, which were poled following a Bessel function. The results show a well focused beam and a depth of field as large as /spl sim/20 times the beam width (6 dB). Moreover, it is verified that the fundamental and some harmonic of the radial mode are suppressed, under an in phase excitation of the rings.
- 19 November 2002
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- Vol. 2, 1023-1027
Analysis of cross-coupling characteristics of piezocomposites 1-3
- 19 November 2002
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- Vol. 2, 1023-1027
Analysis of cross-coupling characteristics of piezocomposites 1-3