JSJulianna C. Simon

Julianna C. Simon

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Julianna C. Simon has a total of 140 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Evaluation of acoustic cavitation from focused ultrasound in commercial and native extracellular matrices

    by Ferdousi Sabera Rawnaque, Julianna C Simon

    Objective . Although commercial and native extracellular matrices (ECM) are studied as ultrasound-responsive materials, the influence of their viscoelastic properties on ultrasound responses remains unclear. This study examines how focused ultrasound (FUS) peak negative pressure ( p −) and pulse length affect acoustic cavitation probability and dynamics in commercial and native ECM (nECM). Approach . A 3.68 MHz single element FUS transducer (f# = 1) delivered 100–600 μ s pulses at 1 Hz with p −⩽ 6.2 MPa in commercial ECM scaffolds (PureCol EZ-Gel and Cultrex Ultimatrix) as well as nECM derived from decellularized porcine kidney and liver. A 3.68 MHz FUS transducer (f# = 1) delivered 100–600 μ s pulses at 1 Hz PRF with p −⩽ 6.2 MPa. Cavitation events were captured using brightfield microscopy and high-speed imaging at 20 000 fps. A viscoelasticity corrected Rayleigh–Plesset based bubble model was compared with the experimental results. Main Results . The nECM derived from decellularized porcine kidney and liver, having higher elastic moduli compared to PureCol and Cultrex, consistently exhibited higher cavitation thresholds. Increasing the pulse length from 200 to 600 μ s reduced cavitation thresholds in liver (5.6–4.2 MPa, p = 0.003) and kidney (5.5–4.1 MPa, p = 0.005) nECM, whereas in commercial scaffolds EZ-Gel and Cultrex, thresholds showed minimal change beyond 300 μ s. Experimentally, the largest bubble radii were observed in PureCol EZ-Gel (14.8 ± 3.6 µ m) and the smallest were observed in Cultrex (6.8 ± 1.3 µ m). The computational model qualitatively matched the experimental results for the smallest observed radius and indicated that viscosity was the primary factor in damping bubble expansion compared to elastic modulus. As Cultrex had the highest viscosity of all tested materials, it also showed the minimum radial expansion of r = 5.4 µ m. Significance . Results suggest that medium elasticity influences cavitation threshold and maximum bubble expansion is predominantly affected by both elasticity and viscosity of the medium, which may help interpret cavitation behavior across different ECM conditions.

  • Open Access

    Cavitation dynamics in commercial scaffolds and native extracellular matrix

    by Ferdousi Sabera Rawnaque, Julianna C. Simon

    Commercial scaffolds and native extracellular matrix (nECM) are commonly used for cell reseeding and in vitro tissue models; however, how their viscoelastic differences affect acoustic cavitation remains unclear. Using focused ultrasound (FUS), we examined how pulse length and peak negative pressure (p-) influence cavitation probability in PureCol EZ-Gel, Cultrex Ultimatrix, and nECM derived from decellularized porcine kidney (n = 8 each). A 3.68-MHz FUS transducer (f# = 1) delivered 100–800 µs pulses at 1 Hz PRF with p-≤6.2 MPa. Cavitation events were captured using brightfield microscopy and high-speed imaging at 20 000 fps. A viscoelastic Keller-Miksis-Kelvin-Voigt bubble model was compared to the experimental results. Among the tested materials, nECM consistently showed higher cavitation thresholds than PureCol and Cultrex, supporting the literature that higher elastic modulus suppresses cavitation. In nECM, bubble radius significantly increased from 13.5 ± 2.5 µm to 24.1 ± 4.8 µm as p- increased from 4.1 to 5.8 MPa (p = 0.023). Increasing pulse length from 200 to 600 µs consistently reduced cavitation thresholds in nECM, while thresholds in commercial scaffolds plateaued beyond 300 µs. The model matched relatively well with the experimental results and indicated viscosity damped bubble expansion with minimum radial expansion observed in Cultrex; R max = 5.44 µm. Future work will compare nECM derived from porcine liver with the tested scaffolds/nECM. [Work supported by NSF CAREER 1943937.]

  • Open Access

    Focused Ultrasound-Mediated Release of Bone Morphogenetic Protein 2 from Hydrogels for Bone Regeneration

    by Tyus J. Yeingst, Angelica M. Helton, Ferdousi S. Rawnaque, Julien H. Arrizabalaga, Dino J. Ravnic, Julianna C. Simon, Daniel J. Hayes

    An ultrasound-responsive hydrogel system was developed that provides on-demand release when stimulated by focused ultrasound (fUS). Diels–Alder cycloadducts crosslinked polyethylene glycol (PEG) hydrogels and underwent a retrograde Diels–Alder reaction when exposed to fUS. Four-arm and eight-arm furan-based Diels–Alder hydrogel compositions were used to evaluate the link between the crosslinking density and the fUS-induced release and retention rates. PEG crosslinked with glutaraldehyde was also used as a non-Diels–Alder control hydrogel. By increasing the exposure time and the amplitude of fUS, the Diels–Alder-based hydrogels exhibited a correlative increase in the release of the entrapped BMP-2. Real-time B-mode imaging was used during fUS to visualize the on-demand degradation of the crosslinking matrix for the release of BMP-2. When monitored with a thermocouple, the increase in temperature observed was minimal in the area surrounding the sample during fUS stimulation, indicating fUS to be an external stimulus which could be used safely for spatiotemporally controlled release. PEG hydrogels were characterized using nuclear magnetic resonance, Fourier transform infrared spectroscopy, differential scanning calorimetry, thermogravimetric analysis, and compression testing. PEG degradation byproducts were evaluated for cytocompatibility in vitro. Overall, this study demonstrated that Diels–Alder-based PEG hydrogels can encapsulate BMP-2, undergo a retrograde reaction when externally stimulated with fUS, and release active BMP-2 to induce differentiation in human mesenchymal stem cells.


  • Open Access

    Graduate-level research communication course: Reflections on the first offering

    by Julianna C. Simon

    In Fall 2022, I offered a new course on research communication within the Graduate Program in Acoustics at Penn State. With 8 students from Acoustics and Biomedical Engineering, the course was split into three modules of grant writing, paper writing, and outreach. I found the students were reasonably adept at critically reading single papers. They also generally understood the mechanics of writing sentences, although combining sentences into paragraphs, connecting ideas, reducing fluff, and adding emphasis to key points were areas that significantly improved throughout the semester. In the middle of the course, two mock grant review panels were held, which highlighted a need to help students develop strategies to cope with critical feedback. Thus, for the final project, students had the option to either write a journal paper draft or revise their proposal; they also presented orally on their final project. Additionally, communicating with the public and developing outreach activities were included in the course, which culminated in an Acoustics Day at a science center. Overall, I found identifying gaps in the literature using multiple sources and developing a cogent argument on how their proposed work would fill the gap needed the most improvement. [Partially supported by the NSF CAREER:1943937].


  • Effect of ambient gas and crystal features on Doppler ultrasound twinkling of pathological mineralizations

    by Eric Rokni, Julianna C. Simon

    Color Doppler twinkling on kidney stones and other pathological mineralizations is theorized to arise from stable microbubbles, which suggests twinkling will be sensitive to ambient gas. Here, lab-grown cholesterol, calcium phosphate, and uric acid crystals were imaged with ultrasound in water while varying oxygen, carbon dioxide, and nitrogen levels. Twinkling was found to increase on cholesterol in elevated oxygen, cholesterol and calcium phosphate in elevated carbon dioxide, and no crystals in elevated nitrogen. These results support the crevice microbubble theory of twinkling and suggest gases may be varied to enhance twinkling on some mineralizations.


  • Open Access

    The histotripsy spectrum: differences and similarities in techniques and instrumentation

    by Randall P. Williams, Julianna C. Simon, Vera A. Khokhlova, Oleg A. Sapozhnikov, Tatiana D. Khokhlova

    Since its inception about two decades ago, histotripsy - a non-thermal mechanical tissue ablation technique - has evolved into a spectrum of methods, each with distinct potentiating physical mechanisms: intrinsic threshold histotripsy, shock-scattering histotripsy, hybrid histotripsy, and boiling histotripsy. All methods utilize short, high-amplitude pulses of focused ultrasound delivered at a low duty cycle, and all involve excitation of violent bubble activity and acoustic streaming at the focus to fractionate tissue down to the subcellular level. The main differences are in pulse duration, which spans microseconds to milliseconds, and ultrasound waveform shape and corresponding peak acoustic pressures required to achieve the desired type of bubble activity. In addition, most types of histotripsy rely on the presence of high-amplitude shocks that develop in the pressure profile at the focus due to nonlinear propagation effects. Those requirements, in turn, dictate aspects of the instrument design, both in terms of driving electronics, transducer dimensions and intensity limitations at surface, shape (primarily, the F-number) and frequency. The combination of the optimized instrumentation and the bio-effects from bubble activity and streaming on different tissues, lead to target clinical applications for each histotripsy method. Here, the differences and similarities in the physical mechanisms and resulting bioeffects of each method are reviewed and tied to optimal instrumentation and clinical applications.


  • Dual-frequency boiling histotripsy in an ex vivo bovine tendinopathy model

    by Molly Smallcomb, Julianna C. Simon

    Histotripsy fractionates most soft tissues; however, healthy tendons have shown resistance to histotripsy fractionation. Prior work has shown that pre-heating tendons increases susceptibility to histotripsy fractionation; combining multiple driving frequencies may also allow successful fractionation of tendons. Here, we evaluate single- and dual-frequency histotripsy in four healthy and eight tendinopathic ex vivo bovine tendons. First, we evaluated single-frequency (1.07, 1.5, and 3.68 MHz) and dual-frequency (1.07 and 1.5 MHz or 1.5 and 3.68 MHz) bubble dynamics with high-speed photography in a tissue-mimicking phantom. Then, tendons were treated with histotripsy. Cavitation activity was monitored with a passive cavitation detector (PCD) and targeted areas were evaluated grossly and histologically. Results in tendinopathic tendons showed 1.5 MHz or 3.68 MHz single-frequency exposure caused focal disruption, whereas 1.5 and 3.68 MHz dual-frequency exposures caused fractionated holes; all treatments caused some thermal denaturation. Exposure to 1.07 MHz alone or combined with 1.5 MHz did not show fractionation in tendinopathic tendons. In healthy tendons, only thermal necrosis was observed for all tested exposures. PCD showed some differences in cavitation activity in tendinopathic tendons but did not predict successful fractionation. These results suggest that full histotripsy fractionation is possible using dual-frequency exposures in tendinopathic tendons.


  • Open Access

    Penn State acoustic wave kits (PAWKits)

    by Julianna C. Simon, Daniel A. Russell

    The increasing prevalence of blended resident and distance education courses makes it difficult to implement in-class demonstrations or hands-on activities to enhance learning. Our objective here is to develop and evaluate the use of at-home activity kits in fundamental acoustics and vibration courses for graduate students. First-generation PAWkits includedfive1-ft PVC pipes, four PVC couplers, a PVC end cap, a PVC T-branch, two dental dams, a tuning fork, a bluetooth speaker with passive radiator, a lapel microphone, a thick string, a thin string, ten magnets, four magnetic hooks, four springs (two spring constants), and an alligator clip. The total cost of the kit per student was estimated at $66 plus shipping. The first-generation PAWkit was designed for five main activities includingmeasuring directivity of the speaker and tuning fork, waves in pipes including T-branch and low-pass filters, waves in membranes, waves in strings, and mass-spring vibration systems. Activities were tested across two required Penn State first-year required courses for graduate students. PAWkits are currently being evaluated through student surveys and, in the future, by tracking the performance of Ph.D. students on the qualifying exam. [Work supported by Penn State Leonhard Center Seed Grant.]

  • Open Access

    Histotripsy of healthy and tendinopathic ex vivo bovine tendons

    by Molly Smallcomb, Julianna C. Simon

    Histotripsy has successfully fractionated most soft tissues; however, highly collagenous tissues like tendon have been resistant to histotripsy fractionation. Previously, we showed that some histotripsy parameters could create mild mechanical microdamage in healthy ex vivo rat tendons. Our objective here is to evaluate whether complete histotripsy fractionation is possible in tendons. Eight bovine tendons were injected with collagenase to induce tendinopathy; an additional four tendons were unaltered. Tendons were exposed to single- or dual-frequency histotripsy at 1.07-, 1.5-, and/or 3.68-MHz with 10-ms pulses delivered at 1 Hz for 60 s. Treatments were monitored with passive cavitation detection (PCD) and samples were evaluated for damage. Results show that exposure of tendinopathic tendons to 1.5- and 3.68-MHz dual-frequency histotripsy produces a distinct, fractionated hole; 1.5- and 3.68-MHz single-frequency histotripsy produces partial fractionation without a distinct hole. No fractionation was observed in healthy tendons, or in tendinopathic tendons exposed to 1.07 MHz single- or dual-frequency histotripsy. Histologically, all tendons showed evidence of thermal necrosis independent of whether a hole was observed. PCD showsincreases in amplitude and sustainment of cavitation in exposures that successfully fractionated tendon. These results suggest histotripsy fractionation is possible in tendinopathic tendons. [Work supported by NIH R21EB027886 and R01EB032860.]