Daniel B. Holland
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Daniel B. Holland has a total of 52 co-authors. Here are the top co-authors by number of shared publications:
Geoffrey A. Blake
Division of Chemistry and Chemical Engineering, California Institute of Technology, Pasadena, California 91125, USA
7 shared publicationsScott E. Fraser
4 shared publicationsThai V. Truong
4 shared publicationsChin-Lin Guo
Division of Engineering and Applied Science, California Institute of Technology, Pasadena, California 91125, USA
3 shared publications- Ian A. Finneran
Division of Chemistry and Chemical Engineering, California Institute of Technology, 1200 E California Blvd., Pasadena, CA 91125, USA
3 shared publications Jiun-Yann Yu
Division of Biology and Biological Engineering, California Institute of Technology, Pasadena, CA, 91125, USA
3 shared publications
Latest Publications
- Open Access
- 22 October 2018
- Published by Optica Publishing Group in Optics Letters
- Vol. 43 (21) , 5271-5274
Multiphoton structured thin-plane imaging with a single optical path
Optical sectioning has become an indispensable technique for high-speed volumetric imaging in the past decade. Here we present a novel optical-sectioning method that produces a thin plane of illumination by exploiting the spatial and temporal properties of multiphoton excitation. Critically, the illumination and detection share the same optical path, as in a conventional epi-fluorescence microscope configuration. Therefore, the imaged sample can be prepared as for standard fluorescence microscopy. Our method also leads to a laterally structured illumination pattern, and this feature can be utilized in structured illumination microscopy to further enhance the imaging performance. We show an example of such an approach, which achieves axial resolution finer than confocal microscopy. We also demonstrate the potential of the new method for biological applications by performing three-dimensional imaging of living Caenorhabditis elegans.
- 22 October 2018
- Published by Optica Publishing Group in Optics Letters
- Vol. 43 (21) , 5271-5274
Open AccessMultiphoton structured thin-plane imaging with a single optical path
Optical sectioning has become an indispensable technique for high-speed volumetric imaging in the past decade. Here we present a novel optical-sectioning method that produces a thin plane of illumination by exploiting the spatial and temporal properties of multiphoton excitation. Critically, the illumination and detection share the same optical path, as in a conventional epi-fluorescence microscope configuration. Therefore, the imaged sample can be prepared as for standard fluorescence microscopy. Our method also leads to a laterally structured illumination pattern, and this feature can be utilized in structured illumination microscopy to further enhance the imaging performance. We show an example of such an approach, which achieves axial resolution finer than confocal microscopy. We also demonstrate the potential of the new method for biological applications by performing three-dimensional imaging of living Caenorhabditis elegans.
- Open Access
- 5 October 2018
- Published by Springer Nature in Scientific Reports
- Vol. 8 (1) , 14863
Fiber-bundle illumination: realizing high-degree time-multiplexed multifocal multiphoton microscopy with simplicity
High-degree time-multiplexed multifocal multiphoton microscopy was expected to provide a facile path to scanningless optical-sectioning and the fast imaging of dynamic three-dimensional biological systems. However, physical constraints on typical time multiplexing devices, arising from diffraction in the free-space propagation of light waves, lead to significant manufacturing difficulties and have prevented the experimental realization of high-degree time multiplexing. To resolve this issue, we have developed a novel method using optical fiber bundles of various lengths to confine the diffraction of propagating light waves and to create a time multiplexing effect. Through this method, we experimentally demonstrate the highest degree of time multiplexing ever achieved in multifocal multiphoton microscopy (~50 times larger than conventional approaches), and hence the potential of using simply-manufactured devices for scanningless optical sectioning of biological systems.
- 5 October 2018
- Published by Springer Nature in Scientific Reports
- Vol. 8 (1) , 14863
Open AccessFiber-bundle illumination: realizing high-degree time-multiplexed multifocal multiphoton microscopy with simplicity
High-degree time-multiplexed multifocal multiphoton microscopy was expected to provide a facile path to scanningless optical-sectioning and the fast imaging of dynamic three-dimensional biological systems. However, physical constraints on typical time multiplexing devices, arising from diffraction in the free-space propagation of light waves, lead to significant manufacturing difficulties and have prevented the experimental realization of high-degree time multiplexing. To resolve this issue, we have developed a novel method using optical fiber bundles of various lengths to confine the diffraction of propagating light waves and to create a time multiplexing effect. Through this method, we experimentally demonstrate the highest degree of time multiplexing ever achieved in multifocal multiphoton microscopy (~50 times larger than conventional approaches), and hence the potential of using simply-manufactured devices for scanningless optical sectioning of biological systems.
- 1 February 2016
- Published by Elsevier in Biophysical Journal
- Vol. 110 (3) , 164a-165a
Optimized Volumetric Live Imaging with Light Field Microscopy and Selective Volume Illumination
- 1 February 2016
- Published by Elsevier in Biophysical Journal
- Vol. 110 (3) , 164a-165a
Optimized Volumetric Live Imaging with Light Field Microscopy and Selective Volume Illumination
- Open Access
- 1 February 2016
- Published by Elsevier in Biophysical Journal
- Vol. 110 (3) , 148a
Immunoimaging with Light Sheet Microscopy: Microglial Dynamics in the Developing Zebrafish Brain
- 1 February 2016
- Published by Elsevier in Biophysical Journal
- Vol. 110 (3) , 148a
Open AccessImmunoimaging with Light Sheet Microscopy: Microglial Dynamics in the Developing Zebrafish Brain
- 1 October 2015
- Published by AIP Publishing in Review of Scientific Instruments
- Vol. 86 (10) , 103107
A decade-spanning high-resolution asynchronous optical sampling terahertz time-domain and frequency comb spectrometer
We present the design and capabilities of a high-resolution, decade-spanning ASynchronous OPtical Sampling (ASOPS)-based TeraHertz Time-Domain Spectroscopy (THz-TDS) instrument. Our system employs dual mode-locked femtosecond Ti:Sapphire oscillators with repetition rates offset locked at 100 Hz via a Phase-Locked Loop (PLL) operating at the 60th harmonic of the ∼80 MHz oscillator repetition rates. The respective time delays of the individual laser pulses are scanned across a 12.5 ns window in a laboratory scan time of 10 ms, supporting a time delay resolution as fine as 15.6 fs. The repetition rate of the pump oscillator is synchronized to a Rb frequency standard via a PLL operating at the 12th harmonic of the oscillator repetition rate, achieving milliHertz (mHz) stability. We characterize the timing jitter of the system using an air-spaced etalon, an optical cross correlator, and the phase noise spectrum of the PLL. Spectroscopic applications of ASOPS-THz-TDS are demonstrated by measuring water vapor absorption lines from 0.55 to 3.35 THz and acetonitrile absorption lines from 0.13 to 1.39 THz in a short pathlength gas cell. With 70 min of data acquisition, a 50 dB signal-to-noise ratio is achieved. The achieved root-mean-square deviation is 14.6 MHz, with a mean deviation of 11.6 MHz, for the measured water line center frequencies as compared to the JPL molecular spectroscopy database. Further, with the same instrument and data acquisition hardware, we use the ability to control the repetition rate of the pump oscillator to enable THz frequency comb spectroscopy (THz-FCS). Here, a frequency comb with a tooth width of 5 MHz is generated and used to fully resolve the pure rotational spectrum of acetonitrile with Doppler-limited precision. The oscillator repetition rate stability achieved by our PLL lock circuits enables sub-MHz tooth width generation, if desired. This instrument provides unprecedented decade-spanning, tunable resolution, from 80 MHz down to sub-MHz, and heralds a new generation of gas-phase spectroscopic tools in the THz region.
- 1 October 2015
- Published by AIP Publishing in Review of Scientific Instruments
- Vol. 86 (10) , 103107
A decade-spanning high-resolution asynchronous optical sampling terahertz time-domain and frequency comb spectrometer
We present the design and capabilities of a high-resolution, decade-spanning ASynchronous OPtical Sampling (ASOPS)-based TeraHertz Time-Domain Spectroscopy (THz-TDS) instrument. Our system employs dual mode-locked femtosecond Ti:Sapphire oscillators with repetition rates offset locked at 100 Hz via a Phase-Locked Loop (PLL) operating at the 60th harmonic of the ∼80 MHz oscillator repetition rates. The respective time delays of the individual laser pulses are scanned across a 12.5 ns window in a laboratory scan time of 10 ms, supporting a time delay resolution as fine as 15.6 fs. The repetition rate of the pump oscillator is synchronized to a Rb frequency standard via a PLL operating at the 12th harmonic of the oscillator repetition rate, achieving milliHertz (mHz) stability. We characterize the timing jitter of the system using an air-spaced etalon, an optical cross correlator, and the phase noise spectrum of the PLL. Spectroscopic applications of ASOPS-THz-TDS are demonstrated by measuring water vapor absorption lines from 0.55 to 3.35 THz and acetonitrile absorption lines from 0.13 to 1.39 THz in a short pathlength gas cell. With 70 min of data acquisition, a 50 dB signal-to-noise ratio is achieved. The achieved root-mean-square deviation is 14.6 MHz, with a mean deviation of 11.6 MHz, for the measured water line center frequencies as compared to the JPL molecular spectroscopy database. Further, with the same instrument and data acquisition hardware, we use the ability to control the repetition rate of the pump oscillator to enable THz frequency comb spectroscopy (THz-FCS). Here, a frequency comb with a tooth width of 5 MHz is generated and used to fully resolve the pure rotational spectrum of acetonitrile with Doppler-limited precision. The oscillator repetition rate stability achieved by our PLL lock circuits enables sub-MHz tooth width generation, if desired. This instrument provides unprecedented decade-spanning, tunable resolution, from 80 MHz down to sub-MHz, and heralds a new generation of gas-phase spectroscopic tools in the THz region.
- Open Access
- 11 May 2015
- Published by Optica Publishing Group in Biomedical Optics Express
- Vol. 6 (6) , 2056-2066
Dynamic structure and protein expression of the live embryonic heart captured by 2-photon light sheet microscopy and retrospective registration
We present an imaging and image reconstruction pipeline that captures the dynamic three-dimensional beating motion of the live embryonic zebrafish heart at subcellular resolution. Live, intact zebrafish embryos were imaged using 2-photon light sheet microscopy, which offers deep and fast imaging at 70 frames per second, and the individual optical sections were assembled into a full 4D reconstruction of the beating heart using an optimized retrospective image registration algorithm. This imaging and reconstruction platform permitted us to visualize protein expression patterns at endogenous concentrations in zebrafish gene trap lines.
- 11 May 2015
- Published by Optica Publishing Group in Biomedical Optics Express
- Vol. 6 (6) , 2056-2066
Open AccessDynamic structure and protein expression of the live embryonic heart captured by 2-photon light sheet microscopy and retrospective registration
We present an imaging and image reconstruction pipeline that captures the dynamic three-dimensional beating motion of the live embryonic zebrafish heart at subcellular resolution. Live, intact zebrafish embryos were imaged using 2-photon light sheet microscopy, which offers deep and fast imaging at 70 frames per second, and the individual optical sections were assembled into a full 4D reconstruction of the beating heart using an optimized retrospective image registration algorithm. This imaging and reconstruction platform permitted us to visualize protein expression patterns at endogenous concentrations in zebrafish gene trap lines.
- Open Access
- 21 April 2015
- Published by American Physical Society (APS) in Physical Review Letters
- Vol. 114 (16) , 163902
Decade-Spanning High-Precision Terahertz Frequency Comb
The generation and detection of a decade-spanning terahertz (THz) frequency comb is reported using two Ti:sapphire femtosecond laser oscillators and asynchronous optical sampling THz time-domain spectroscopy. The comb extends from 0.15 to 2.4 THz, with a tooth spacing of 80 MHz, a linewidth of 3.7 kHz, and a fractional precision of . With time-domain detection of the comb, we measure three transitions of water vapor at 10 mTorr between 1–2 THz with an average Doppler-limited fractional accuracy of . Significant improvements in bandwidth, resolution, and sensitivity are possible with existing technologies.- 21 April 2015
- Published by American Physical Society (APS) in Physical Review Letters
- Vol. 114 (16) , 163902
Open AccessDecade-Spanning High-Precision Terahertz Frequency Comb
The generation and detection of a decade-spanning terahertz (THz) frequency comb is reported using two Ti:sapphire femtosecond laser oscillators and asynchronous optical sampling THz time-domain spectroscopy. The comb extends from 0.15 to 2.4 THz, with a tooth spacing of 80 MHz, a linewidth of 3.7 kHz, and a fractional precision of . With time-domain detection of the comb, we measure three transitions of water vapor at 10 mTorr between 1–2 THz with an average Doppler-limited fractional accuracy of . Significant improvements in bandwidth, resolution, and sensitivity are possible with existing technologies. - 1 January 2014
- Published by Elsevier in Biophysical Journal
- Vol. 106 (2) , 435a-436a
Live 4D Imaging of the Embryonic Vertebrate Heart with Two-Photon Light Sheet Microscopy and Simultaneous Optical Phase Stamping
- 1 January 2014
- Published by Elsevier in Biophysical Journal
- Vol. 106 (2) , 435a-436a
Live 4D Imaging of the Embryonic Vertebrate Heart with Two-Photon Light Sheet Microscopy and Simultaneous Optical Phase Stamping
- 1 August 2013
- Published by AIP Publishing in Review of Scientific Instruments
- Vol. 84 (8) , 083104
A direct digital synthesis chirped pulse Fourier transform microwave spectrometer
Chirped pulse Fourier transform microwave (CP-FTMW) spectrometers have become the instrument of choice for acquiring rotational spectra, due to their high sensitivity, fast acquisition rate, and large bandwidth. Here we present the design and capabilities of a recently constructed CP-FTMW spectrometer using direct digital synthesis (DDS) as a new method for chirped pulse generation, through both a suite of extensive microwave characterizations and deep averaging of the 10-14 GHz spectrum of jet-cooled acetone. The use of DDS is more suited for in situ applications of CP-FTMW spectroscopy, as it reduces the size, weight, and power consumption of the chirp generation segment of the spectrometer all by more than an order of magnitude, while matching the performance of traditional designs. The performance of the instrument was further improved by the use of a high speed digitizer with dedicated signal averaging electronics, which facilitates a data acquisition rate of 2.1 kHz.
- 1 August 2013
- Published by AIP Publishing in Review of Scientific Instruments
- Vol. 84 (8) , 083104
A direct digital synthesis chirped pulse Fourier transform microwave spectrometer
Chirped pulse Fourier transform microwave (CP-FTMW) spectrometers have become the instrument of choice for acquiring rotational spectra, due to their high sensitivity, fast acquisition rate, and large bandwidth. Here we present the design and capabilities of a recently constructed CP-FTMW spectrometer using direct digital synthesis (DDS) as a new method for chirped pulse generation, through both a suite of extensive microwave characterizations and deep averaging of the 10-14 GHz spectrum of jet-cooled acetone. The use of DDS is more suited for in situ applications of CP-FTMW spectroscopy, as it reduces the size, weight, and power consumption of the chirp generation segment of the spectrometer all by more than an order of magnitude, while matching the performance of traditional designs. The performance of the instrument was further improved by the use of a high speed digitizer with dedicated signal averaging electronics, which facilitates a data acquisition rate of 2.1 kHz.
- 18 January 2013
- Published by Optica Publishing Group in Optics Express
- Vol. 21 (2) , 2097-2109
The wide-field optical sectioning of microlens array and structured illumination-based plane-projection multiphoton microscopy
Optics InfoBase is the Optical Society's online library for flagship journals, partnered and copublished journals, and recent proceedings from OSA conferences.
- 18 January 2013
- Published by Optica Publishing Group in Optics Express
- Vol. 21 (2) , 2097-2109
The wide-field optical sectioning of microlens array and structured illumination-based plane-projection multiphoton microscopy
Optics InfoBase is the Optical Society's online library for flagship journals, partnered and copublished journals, and recent proceedings from OSA conferences.