MGMary Gregg

Mary Gregg

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Mary Gregg has a total of 43 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Terrestrial laser scanners and contrast targets: effect of algorithm, resolution, distance, and target rotational orientation on center coordinate

    by Bala Muralikrishnan, Aum Shah, Mary Gregg, Meghan Shilling, Vincent Lee, Braden Czapla

    Terrestrial laser scanners (TLSs) are portable dimensional measurement instruments that produce a 3D point cloud by measuring the distance and two angles to points in the scene. Contrast targets are sometimes used to evaluate the performance of these scanners by comparing inter-target distances to measurements made using higher accuracy instruments or to register scans from different positions of the TLS. The choice of algorithm, distance of the target from the TLS, scan resolution, and rotational orientation of the target contribute to errors in the target center coordinates. We explored this problem using an artifact consisting of spheres and a contrast target that allowed us to monitor the center of the contrast target in a coordinate system established using the spheres, where the assumption is that the sphere centers are unaffected by factors mentioned earlier and therefore provide a stable coordinate system. We considered three different TLSs and four algorithms to detect contrast target center (three custom developed and one from the manufacturer). For each TLS, we performed scans at two distances, two resolutions, and three rotational orientations of the target, for a total of 12 cases (with 10 repeated scans per case, total of 120 scans). We calculated two response variables for each case—inter-case variation d and intra-case variation s . For TLS A, low resolution scans produced the worst results (large d and s values) for the original equipment manufacturer (OEM) algorithm, with d and s as large as 2 and 0.3 mm, respectively, for one of the cases. For TLS B, target orientation of 90° produced the worst results for the OEM algorithm, with d and s as large as 2 and 1.3 mm, respectively, for certain cases. For TLS C, only the far distance, low resolution, and 90° target orientation case produced the worst result for the OEM algorithm, with d and s values as large as 0.3 and 0.6 mm, respectively. Our custom algorithms clearly outperformed the OEM algorithms for TLS A and B and while the OEM algorithm marginally outperformed the custom algorithms for TLS C.


  • Toward Improved Standards for Open RAN Interoperability: A Factor Screening Experiment

    by Aziz Kord, Mary Gregg, M. Keith Forsyth, Julia L. Sharp, Jason B. Coder, Vu Le

    As Open Radio Access Networks (Open RAN) move toward large-scale deployment, the industry requires a transition from binary “pass/fail” conformance testing to a rigorous performance metrology that characterizes system stability in multi-vendor environments. This study introduces a statistical factor screening methodology, utilizing a Resolution V fractional factorial design, to isolate the key configuration parameters that govern interoperability in a commercial-grade 7.2x functional split testbed. By executing a 1,024-run automated experimental campaign, we identify critical non-linear "performance boundaries" where specific combinations of modulation coding, power control, and UE scaling cause functional decoupling between disaggregated O-DU and O-RU components. Our results demonstrate that O-RU interoperability is not a static state but a dynamic boundary of functional invariance. This work provides a mathematically grounded framework for Mobile Network Operators (MNOs) to prioritize high-impact factors in certification and badging, accelerating the maturity of secure, high-capacity Open RAN ecosystems.

  • Open Access

    Factors influencing the recovery of Δ9-tetrahydrocannabinol, cannabidiol, and cannabinol from a breath sampling device

    by Jennifer Berry, Mary Gregg, Kavita M. Jeerage

    Cannabinoids can be captured from breath after cannabis use, but sample processing varies between studies, even when using the same sampling device. The Breath Explor impaction filter device has been used to capture THC in breath after cannabis use in multiple studies, but processing differed in solvent type, keeper addition, and concentration method. In this study we test the effect that container material, vacuum concentration, keeper, elution solvent, cannabinoid mass, agitation, and elution time have on the recovery of Δ9-tetrahydrocannabinol, cannabidiol, and cannabinol from spiked breath samples. Only container material and keeper had a significant impact on recovery, although limiting the use of plastic vials, one of the two container materials studied, did have some mitigating effects. Despite these two factors having a significant effect, the recovery of cannabinoids remained relatively low. Further investigation showed that our process for the preparation of spiked breath samples, specifically the complete evaporation of a small volume of spike solvent, leads to large cannabinoid losses. As recently published high-accuracy vapor pressure data indicates that these cannabinoids should be considered semi-volatile, a microelution process was additionally explored as it requires less solvent and therefore no concentration is necessary during sample processing. The microelution process resulted in similar or higher recoveries of cannabinoids as compared to the large volume elution process, suggesting that it is a superior processing method in terms of recovery and processing time.

  • Calibrating inter-target distances in a network with high accuracy using a terrestrial laser scanner

    by Bala Muralikrishnan, Meghan Shilling, Vincent Lee, Mary Gregg, Dennis Everett


  • Open Access

    Toward a documentary standard for performance testing of terrestrial laser scanners used in forensic practice: A statistical procedure to assess change in instrument precision

    by Mary Gregg, Bala Muralikrishnan, Meghan Shilling

    This paper documents efforts by members of the Crime Scene Investigation and Reconstruction (CSIR) subcommittee within the Organization of Scientific Area Committees (OSAC) for Forensic Science, in collaboration with researchers at the National Institute of Standards and Technology, to develop a documentary standard for performance assessment testing of terrestrial laser scanners (TLSs). Intended to be performed by forensic practitioners, this “Interim Performance Assessment” is specifically designed to be inexpensive, concise, and flexible, and is comprised of two parts that separately evaluate instrument accuracy and precision. This paper motivates and details the second of these test procedures, which uses a statistical methodology to assess whether an instrument's point coordinate precision has significantly changed over time. In this paper, the statistical details are reviewed, and the proposed test procedure is illustrated through two examples of longitudinal TLS data. The utility, scope, and limitations of the proposed test procedure are discussed in the context of instrument quality assurance.


  • Report on the May 2025 NIST Measurement Week :

    by Bala Muralikrishnan, Meghan Shilling, Mary Gregg, Vincent Lee, Jason Keller, Erin Casey, Eugene Liscio, Bryon O'NEil, Michael Russ, Toby Terpstra

    This report describes a terrestrial laser scanner (TLS) testing event, the NIST Measurement Week, held at the National Institute of Standards and Technology (NIST) during the week of May 12-16, 2025. The Crime Scene Investigation and Reconstruction (CSIR) subcommittee of the Organization of Scientific Area Committees (OSAC) for Forensic Science is currently involved in the development of an Interim Performance Assessment (IPA) procedure that can be performed in-house by law enforcement agencies and forensic consulting firms. The Dimensional Metrology Group (DMG) at NIST set up the test at their facility and invited law enforcement agencies and TLS manufactures to run the IPA and provide feedback. This report describes the event, the lessons learned and key takeaways.


  • Open Access

    Robust discrimination between closely related species of salmon based on DNA fragments

    by Debra Ellisor, Mary Gregg, Angela Folz, Antonio Possolo

    Closely related species of Salmonidae, including Pacific and Atlantic salmon, can be distinguished from one another based on nucleotide sequences from the cytochrome c oxidase sub-unit 1 mitochondrial gene (COI), using ensembles of fragments aligned to genetic barcodes that serve as digital proxies for the relevant species. This is accomplished by exploiting both the nucleotide sequences and their quality scores recorded in a FASTQ file obtained via Next Generation (NextGen) Sequencing of mitochondrial DNA extracted from Coho salmon caught with hook and line in the Gulf of Alaska. The alignment is done using MUSCLE (Muscle 5.2) [1], applied to multiple versions of each fragment perturbed according to the nucleobase identification error probabilities underlying the quality scores. The Damerau-Levenshtein distance was used to determine the genetic barcode of the candidate species that is closest to each aligned, perturbed fragment. The “votes” that the sampled fragments cast for the different candidate species are then pooled and converted into identification probabilities, using weights determined by the entropy of the fragment-specific identification probability distributions. This novel approach to quantify the uncertainty associated with measurements made using NextGen Sequencing can be applied to discriminate closely related species, hence to value-assignment for reference materials supporting determinations of the authenticity of seafood, for example, NIST Reference Materials 8256 and 8257 (Coho salmon) [2].


  • Open Access

    A Method to Evaluate Orientation-Dependent Errors in the Center of Contrast Targets Used with Terrestrial Laser Scanners

    by Bala Muralikrishnan, Xinsu Lu, Mary Gregg, Meghan Shilling, Braden Czapla

    Terrestrial laser scanners (TLS) are portable dimensional measurement instruments used to obtain 3D point clouds of objects in a scene. While TLSs do not require the use of cooperative targets, they are sometimes placed in a scene to fuse or compare data from different instruments or data from the same instrument but from different positions. A contrast target is an example of such a target; it consists of alternating black/white squares that can be printed using a laser printer. Because contrast targets are planar as opposed to three-dimensional (like a sphere), the center of the target might suffer from errors that depend on the orientation of the target with respect to the TLS. In this paper, we discuss a low-cost method to characterize such errors and present results obtained from a short-range TLS and a long-range TLS. Our method involves comparing the center of a contrast target against the center of spheres and, therefore, does not require the use of a reference instrument or calibrated objects. For the short-range TLS, systematic errors of up to 0.5 mm were observed in the target center as a function of the angle for the two distances (5 m and 10 m) and resolutions (30 points-per-degree (ppd) and 90 ppd) considered for this TLS. For the long-range TLS, systematic errors of about 0.3 mm to 0.8 mm were observed in the target center as a function of the angle for the two distances (5 m and 10 m) at low resolution (28 ppd). Errors of under 0.3 mm were observed in the target center as a function of the angle for the two distances at high resolution (109 ppd).


  • Anomalous state detection in radio access networks: A proof-of-concept

    by Michael Frey, Thomas Evans, Angela Folz, Mary Gregg, Jeanne Quimby, Jacob D. Rezac