Félix Fanjul-Vélez
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Félix Fanjul-Vélez has a total of 109 co-authors. Here are the top co-authors by number of shared publications:
J. L. Arce-Diego
Applied Optical Techniques Group, TEISA Department, University of Cantabria, Av de los Castros s/n, 39005 Santander ( Spain)
46 shared publicationsN. Ortega-Quijano
Univ. de Cantabria (Spain)
27 shared publicationsJosé Luis Arce-Diego
University of Cantabria
25 shared publicationsI. Salas-García
24 shared publicationsIrene Salas-García
Applied Optical Techniques Group, Electronics Technology, Systems and Automation Engineering Department, University of Cantabria, Avenida de los Castros S/N, 39005 Santander, Spain
14 shared publications- Noé Ortega-Quijano
Institut de Physique de Rennes, CNRS, Université de Rennes 1, Campus de Beaulieu, 35 042 Rennes, France
12 shared publications
Latest Publications
- Open Access
A Specimen-Separated Machine Learning Benchmark Toward Real-Time Tissue-Type Identification in Guided Surgery Using Ex Vivo Bovine Laser-Induced Breakdown Spectroscopy
Real-time tissue identification during laser-guided surgery is a critical unmet need for collateral damage avoidance and margin delineation. Laser-Induced Breakdown Spectroscopy (LIBS) is compatible with pulsed laser surgical systems and offers rapid, label-free elemental analysis. This study presents a machine learning pipeline classifying five ex vivo bovine tissue classes, plus one synthetic null-signal control class, from LIBS spectra, designed to control specimen-level data leakage and class imbalance bias. Key contributions are (i) a ‘peak max over baseline’ aggregation strategy suppressing shot noise while preserving emission peaks; (ii) a repeated, group-based cross-validation protocol (GroupShuffleSplit, N = 10) enforcing specimen-level separation; and (iii) a comparison of 30 configurations (10 classifiers × 3 pipelines). Extra Trees with normalization reached the highest weighted F1-score (0.934 ± 0.118); excluding the synthetic control, five-class scores fall to 0.875–0.915 and the ranking changes, so these are the reference figures for biological tissue discrimination. Support Vector Machines were less accurate but more consistent (0.917 ± 0.069). Acquisition takes approximately 3 s per point; inference is sub-millisecond. With five source animals, the best configuration chosen on the same outer splits, and inner tuning that was not group-aware, these estimates are an exploratory step toward real-time guided surgery.
Open AccessA Specimen-Separated Machine Learning Benchmark Toward Real-Time Tissue-Type Identification in Guided Surgery Using Ex Vivo Bovine Laser-Induced Breakdown Spectroscopy
Real-time tissue identification during laser-guided surgery is a critical unmet need for collateral damage avoidance and margin delineation. Laser-Induced Breakdown Spectroscopy (LIBS) is compatible with pulsed laser surgical systems and offers rapid, label-free elemental analysis. This study presents a machine learning pipeline classifying five ex vivo bovine tissue classes, plus one synthetic null-signal control class, from LIBS spectra, designed to control specimen-level data leakage and class imbalance bias. Key contributions are (i) a ‘peak max over baseline’ aggregation strategy suppressing shot noise while preserving emission peaks; (ii) a repeated, group-based cross-validation protocol (GroupShuffleSplit, N = 10) enforcing specimen-level separation; and (iii) a comparison of 30 configurations (10 classifiers × 3 pipelines). Extra Trees with normalization reached the highest weighted F1-score (0.934 ± 0.118); excluding the synthetic control, five-class scores fall to 0.875–0.915 and the ranking changes, so these are the reference figures for biological tissue discrimination. Support Vector Machines were less accurate but more consistent (0.917 ± 0.069). Acquisition takes approximately 3 s per point; inference is sub-millisecond. With five source animals, the best configuration chosen on the same outer splits, and inner tuning that was not group-aware, these estimates are an exploratory step toward real-time guided surgery.
- Open Access
- 1 November 2024
- Published by SPIE-Intl Soc Optical Eng in Journal of Biomedical Optics
- Vol. 29 (11) , 116001-17
Polarization-insensitive optical coherence tomography using pseudo-depolarized reference light for mitigating birefringence-related image artifacts
SignificanceOptical coherence tomography (OCT) images are prone to image artifacts due to the birefringence of the sample or the optical system when a polarized light source is used for imaging. These artifacts can lead to degraded image quality and diagnostic information.AimWe aim to mitigate these birefringence-related artifacts in OCT images by adding a depolarizer module in the reference arm of the interferometer.ApproachWe investigated different configurations of liquid crystal patterned retarders as pseudo-depolarizers in the reference arm of OCT setups. We identified the most effective depolarization module layout for polarization artifact suppression for a spectral-domain OCT system based on a Michelson and a Mach–Zehnder interferometer.ResultsThe performance of our approach was demonstrated in an achromatic quarter-wave plate allowing the selection of a variety of sample polarization states. A substantial improvement of the OCT signal magnitude was observed after placing the optimal depolarizer configuration, reducing the cross-polarization artifact from 5.7 to 1.8 dB and from 8.0 to 1.0 dB below the co-polarized signal for the fiber-based Michelson and Mach–Zehnder setup, respectively. An imaging experiment in the birefringent scleral tissue of a post-mortem alpine marmot eye and a mouse tail specimen further showcased a significant improvement in the detected signal intensity and an enhanced OCT image quality followed by a drastic elimination of the birefringence-related artifacts.ConclusionsOur study presents a simple yet cost-effective technique to mitigate birefringence-related artifacts in OCT imaging. This method can be readily implemented in existing OCT technology and improve the effectiveness of various OCT imaging applications in biomedicine.
- 1 November 2024
- Published by SPIE-Intl Soc Optical Eng in Journal of Biomedical Optics
- Vol. 29 (11) , 116001-17
Open AccessPolarization-insensitive optical coherence tomography using pseudo-depolarized reference light for mitigating birefringence-related image artifacts
SignificanceOptical coherence tomography (OCT) images are prone to image artifacts due to the birefringence of the sample or the optical system when a polarized light source is used for imaging. These artifacts can lead to degraded image quality and diagnostic information.AimWe aim to mitigate these birefringence-related artifacts in OCT images by adding a depolarizer module in the reference arm of the interferometer.ApproachWe investigated different configurations of liquid crystal patterned retarders as pseudo-depolarizers in the reference arm of OCT setups. We identified the most effective depolarization module layout for polarization artifact suppression for a spectral-domain OCT system based on a Michelson and a Mach–Zehnder interferometer.ResultsThe performance of our approach was demonstrated in an achromatic quarter-wave plate allowing the selection of a variety of sample polarization states. A substantial improvement of the OCT signal magnitude was observed after placing the optimal depolarizer configuration, reducing the cross-polarization artifact from 5.7 to 1.8 dB and from 8.0 to 1.0 dB below the co-polarized signal for the fiber-based Michelson and Mach–Zehnder setup, respectively. An imaging experiment in the birefringent scleral tissue of a post-mortem alpine marmot eye and a mouse tail specimen further showcased a significant improvement in the detected signal intensity and an enhanced OCT image quality followed by a drastic elimination of the birefringence-related artifacts.ConclusionsOur study presents a simple yet cost-effective technique to mitigate birefringence-related artifacts in OCT imaging. This method can be readily implemented in existing OCT technology and improve the effectiveness of various OCT imaging applications in biomedicine.
- Open Access
Evaluation of Diffuse Reflectance Spectroscopy Vegetal Phantoms for Human Pigmented Skin Lesions
Pigmented skin lesions have increased considerably worldwide in the last years, with melanoma being responsible for 75% of deaths and low survival rates. The development and refining of more efficient non-invasive optical techniques such as diffuse reflectance spectroscopy (DRS) is crucial for the diagnosis of melanoma skin cancer. The development of novel diagnostic approaches requires a sufficient number of test samples. Hence, the similarities between banana brown spots (BBSs) and human skin pigmented lesions (HSPLs) could be exploited by employing the former as an optical phantom for validating these techniques. This work analyses the potential similarity of BBSs to HSPLs of volunteers with different skin phototypes by means of several characteristics, such as symmetry, color RGB tonality, and principal component analysis (PCA) of spectra. The findings demonstrate a notable resemblance between the attributes concerning spectrum, area, and color of HSPLs and BBSs at specific ripening stages. Furthermore, the spectral similarity is increased when a fiber-optic probe with a shorter distance (240 µm) between the source fiber and the detector fiber is utilized, in comparison to a probe with a greater distance (2500 µm) for this parameter. A Monte Carlo simulation of sampling volume was used to clarify spectral similarities.
Open AccessEvaluation of Diffuse Reflectance Spectroscopy Vegetal Phantoms for Human Pigmented Skin Lesions
Pigmented skin lesions have increased considerably worldwide in the last years, with melanoma being responsible for 75% of deaths and low survival rates. The development and refining of more efficient non-invasive optical techniques such as diffuse reflectance spectroscopy (DRS) is crucial for the diagnosis of melanoma skin cancer. The development of novel diagnostic approaches requires a sufficient number of test samples. Hence, the similarities between banana brown spots (BBSs) and human skin pigmented lesions (HSPLs) could be exploited by employing the former as an optical phantom for validating these techniques. This work analyses the potential similarity of BBSs to HSPLs of volunteers with different skin phototypes by means of several characteristics, such as symmetry, color RGB tonality, and principal component analysis (PCA) of spectra. The findings demonstrate a notable resemblance between the attributes concerning spectrum, area, and color of HSPLs and BBSs at specific ripening stages. Furthermore, the spectral similarity is increased when a fiber-optic probe with a shorter distance (240 µm) between the source fiber and the detector fiber is utilized, in comparison to a probe with a greater distance (2500 µm) for this parameter. A Monte Carlo simulation of sampling volume was used to clarify spectral similarities.
- 4 January 2024
- Published by Springer Nature
- p. 647-653
Digital Histopathological Discrimination of Label-Free Healthy Tissues by Decision Tree Classifier
- 4 January 2024
- Published by Springer Nature
- p. 647-653
Digital Histopathological Discrimination of Label-Free Healthy Tissues by Decision Tree Classifier
- 4 January 2024
- Published by Springer Nature
- p. 447-452
Influence of Tilt Angle and Probe-Sample Distance on Tissue Diagnosis by Diffuse Reflection Spectra
- 4 January 2024
- Published by Springer Nature
- p. 447-452
Influence of Tilt Angle and Probe-Sample Distance on Tissue Diagnosis by Diffuse Reflection Spectra
- Open Access
Digital Histopathological Discrimination of Label-Free Tumoral Tissues by Artificial Intelligence Phase-Imaging Microscopy
Histopathology is the gold standard for disease diagnosis. The use of digital histology on fresh samples can reduce processing time and potential image artifacts, as label-free samples do not need to be fixed nor stained. This fact allows for a faster diagnosis, increasing the speed of the process and the impact on patient prognosis. This work proposes, implements, and validates a novel digital diagnosis procedure of fresh label-free histological samples. The procedure is based on advanced phase-imaging microscopy parameters and artificial intelligence. Fresh human histological samples of healthy and tumoral liver, kidney, ganglion, testicle and brain were collected and imaged with phase-imaging microscopy. Advanced phase parameters were calculated from the images. The statistical significance of each parameter for each tissue type was evaluated at different magnifications of 10×, 20× and 40×. Several classification algorithms based on artificial intelligence were applied and evaluated. Artificial Neural Network and Decision Tree approaches provided the best general sensibility and specificity results, with values over 90% for the majority of biological tissues at some magnifications. These results show the potential to provide a label-free automatic significant diagnosis of fresh histological samples with advanced parameters of phase-imaging microscopy. This approach can complement the present clinical procedures.
Open AccessDigital Histopathological Discrimination of Label-Free Tumoral Tissues by Artificial Intelligence Phase-Imaging Microscopy
Histopathology is the gold standard for disease diagnosis. The use of digital histology on fresh samples can reduce processing time and potential image artifacts, as label-free samples do not need to be fixed nor stained. This fact allows for a faster diagnosis, increasing the speed of the process and the impact on patient prognosis. This work proposes, implements, and validates a novel digital diagnosis procedure of fresh label-free histological samples. The procedure is based on advanced phase-imaging microscopy parameters and artificial intelligence. Fresh human histological samples of healthy and tumoral liver, kidney, ganglion, testicle and brain were collected and imaged with phase-imaging microscopy. Advanced phase parameters were calculated from the images. The statistical significance of each parameter for each tissue type was evaluated at different magnifications of 10×, 20× and 40×. Several classification algorithms based on artificial intelligence were applied and evaluated. Artificial Neural Network and Decision Tree approaches provided the best general sensibility and specificity results, with values over 90% for the majority of biological tissues at some magnifications. These results show the potential to provide a label-free automatic significant diagnosis of fresh histological samples with advanced parameters of phase-imaging microscopy. This approach can complement the present clinical procedures.
- 7 December 2021
- Published by Optica Publishing Group in Biomedical Optics Express
- Vol. 13 (1) , 197-208
Cytotoxicity analysis of oxazine 4-perchlorate fluorescence nerve potential clinical biomarker for guided surgery
Biological tissue discrimination is relevant in guided surgery. Nerve identification is critical to avoid potentially severe collateral damage. Fluorescence imaging by oxazine 4-perchlorate (O4P) has been recently proposed. In this work, the cytotoxicity of O4P on U87 human-derived glioma cells has been investigated as a function of concentration and operating room irradiation modes. A custom-built optical irradiation device was employed for controlled optical dosimetry. DNA damage and O4P intracellular localization was also investigated by immunofluorescence and confocal microscopy. The results show that concentration below 100 mu M can be considered safe. These results contribute to the assessment of the feasibility of O4P as a nerve biomarker. (c) 2021 Optica Publishing Group under the terms of the Optica Open Access Publishing Agreement
- 7 December 2021
- Published by Optica Publishing Group in Biomedical Optics Express
- Vol. 13 (1) , 197-208
Cytotoxicity analysis of oxazine 4-perchlorate fluorescence nerve potential clinical biomarker for guided surgery
Biological tissue discrimination is relevant in guided surgery. Nerve identification is critical to avoid potentially severe collateral damage. Fluorescence imaging by oxazine 4-perchlorate (O4P) has been recently proposed. In this work, the cytotoxicity of O4P on U87 human-derived glioma cells has been investigated as a function of concentration and operating room irradiation modes. A custom-built optical irradiation device was employed for controlled optical dosimetry. DNA damage and O4P intracellular localization was also investigated by immunofluorescence and confocal microscopy. The results show that concentration below 100 mu M can be considered safe. These results contribute to the assessment of the feasibility of O4P as a nerve biomarker. (c) 2021 Optica Publishing Group under the terms of the Optica Open Access Publishing Agreement
- Open Access
- 1 July 2021
- Published by MDPI AG in Applied Sciences
- Vol. 11 (13) , 6142
Digital Histology by Phase Imaging Specific Biomarkers for Human Tumoral Tissues Discrimination
Histology is the diagnosis gold standard. Conventional biopsy presents artifacts, delays, or human bias. Digital histology includes automation and improved diagnosis. It digitalizes microscopic images of histological samples and analyzes similar parameters. The present approach proposes the novel use of phase contrast in clinical digital histology to improve diagnosis. The use of label-free fresh tissue slices prevents processing artifacts and reduces processing time. Phase contrast parameters are implemented and calculated: the external scale, the fractal dimension, the anisotropy factor, the scattering coefficient, and the refractive index variance. Images of healthy and tumoral samples of liver, colon, and kidney are employed. A total of 252 images with 10×, 20×, and 40× magnifications are measured. Discrimination significance between healthy and tumoral tissues is assessed statistically with ANOVA (p-value < 0.005). The analysis is made for each tissue type and for different magnifications. It shows a dependence on tissue type and image magnification. The p-value of the most significant parameters is below 10−5. Liver and colon tissues present a great overlap in significant phase contrast parameters. The 10× fractal dimension is significant for all tissue types under analysis. These results are promising for the use of phase contrast in digital histology clinical praxis.
- 1 July 2021
- Published by MDPI AG in Applied Sciences
- Vol. 11 (13) , 6142
Open AccessDigital Histology by Phase Imaging Specific Biomarkers for Human Tumoral Tissues Discrimination
Histology is the diagnosis gold standard. Conventional biopsy presents artifacts, delays, or human bias. Digital histology includes automation and improved diagnosis. It digitalizes microscopic images of histological samples and analyzes similar parameters. The present approach proposes the novel use of phase contrast in clinical digital histology to improve diagnosis. The use of label-free fresh tissue slices prevents processing artifacts and reduces processing time. Phase contrast parameters are implemented and calculated: the external scale, the fractal dimension, the anisotropy factor, the scattering coefficient, and the refractive index variance. Images of healthy and tumoral samples of liver, colon, and kidney are employed. A total of 252 images with 10×, 20×, and 40× magnifications are measured. Discrimination significance between healthy and tumoral tissues is assessed statistically with ANOVA (p-value < 0.005). The analysis is made for each tissue type and for different magnifications. It shows a dependence on tissue type and image magnification. The p-value of the most significant parameters is below 10−5. Liver and colon tissues present a great overlap in significant phase contrast parameters. The 10× fractal dimension is significant for all tissue types under analysis. These results are promising for the use of phase contrast in digital histology clinical praxis.
- Open Access
Application of Classification Algorithms to Diffuse Reflectance Spectroscopy Measurements for Ex Vivo Characterization of Biological Tissues
Biological tissue identification in real clinical scenarios is a relevant and unsolved medical problem, particularly in the operating room. Although it could be thought that healthy tissue identification is an immediate task, in practice there are several clinical situations that greatly impede this process. For instance, it could be challenging in open surgery in complex areas, such as the neck, where different structures are quite close together, with bleeding and other artifacts affecting visual inspection. Solving this issue requires, on one hand, a high contrast noninvasive technique and, on the other hand, powerful classification algorithms. Regarding the technique, optical diffuse reflectance spectroscopy has demonstrated such capabilities in the discrimination of tumoral and healthy biological tissues. The complex signals obtained, in the form of spectra, need to be adequately computed in order to extract relevant information for discrimination. As usual, accurate discrimination relies on massive measurements, some of which serve as training sets for the classification algorithms. In this work, diffuse reflectance spectroscopy is proposed, implemented, and tested as a potential technique for healthy tissue discrimination. A specific setup is built and spectral measurements on several ex vivo porcine tissues are obtained. The massive data obtained are then analyzed for classification purposes. First of all, considerations about normalization, detrending and noise are taken into account. Dimensionality reduction and tendencies extraction are also considered. Featured spectral characteristics, principal component or linear discrimination analysis are applied, as long as classification approaches based on k-nearest neighbors (k-NN), quadratic discrimination analysis (QDA) or Naïve Bayes (NB). Relevant parameters about classification accuracy are obtained and compared, including ANOVA tests. The results show promising values of specificity and sensitivity of the technique for some classification algorithms, even over 95%, which could be relevant for clinical applications in the operating room.
Open AccessApplication of Classification Algorithms to Diffuse Reflectance Spectroscopy Measurements for Ex Vivo Characterization of Biological Tissues
Biological tissue identification in real clinical scenarios is a relevant and unsolved medical problem, particularly in the operating room. Although it could be thought that healthy tissue identification is an immediate task, in practice there are several clinical situations that greatly impede this process. For instance, it could be challenging in open surgery in complex areas, such as the neck, where different structures are quite close together, with bleeding and other artifacts affecting visual inspection. Solving this issue requires, on one hand, a high contrast noninvasive technique and, on the other hand, powerful classification algorithms. Regarding the technique, optical diffuse reflectance spectroscopy has demonstrated such capabilities in the discrimination of tumoral and healthy biological tissues. The complex signals obtained, in the form of spectra, need to be adequately computed in order to extract relevant information for discrimination. As usual, accurate discrimination relies on massive measurements, some of which serve as training sets for the classification algorithms. In this work, diffuse reflectance spectroscopy is proposed, implemented, and tested as a potential technique for healthy tissue discrimination. A specific setup is built and spectral measurements on several ex vivo porcine tissues are obtained. The massive data obtained are then analyzed for classification purposes. First of all, considerations about normalization, detrending and noise are taken into account. Dimensionality reduction and tendencies extraction are also considered. Featured spectral characteristics, principal component or linear discrimination analysis are applied, as long as classification approaches based on k-nearest neighbors (k-NN), quadratic discrimination analysis (QDA) or Naïve Bayes (NB). Relevant parameters about classification accuracy are obtained and compared, including ANOVA tests. The results show promising values of specificity and sensitivity of the technique for some classification algorithms, even over 95%, which could be relevant for clinical applications in the operating room.
- 1 January 2019
- Published by Optica Publishing Group
- p. FTu1F.2
In vivo animal image-guided surgery by fluorescence imaging applied to nerve
Biological tissues identification is of utmost relevance in guided surgery. Nerve contrast is particularly critical, as undesired damage could cause severe collateral effects on patients. Fluorescence imaging could contribute to this aim.
- 1 January 2019
- Published by Optica Publishing Group
- p. FTu1F.2
In vivo animal image-guided surgery by fluorescence imaging applied to nerve
Biological tissues identification is of utmost relevance in guided surgery. Nerve contrast is particularly critical, as undesired damage could cause severe collateral effects on patients. Fluorescence imaging could contribute to this aim.