Mustafa Inalli
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Mustafa Inalli has a total of 17 co-authors. Here are the top co-authors by number of shared publications:
- Hikmet Esen
Firat Universitesi
17 shared publications - Mehmet Esen
Firat University
10 shared publications - Abdulkadir Sengur
Department of Electrical-Electronic Engineering, Faculty of Technology, Firat University, 23000 Elazig, Turkey
6 shared publications A. Ucar
3 shared publications- Berkay Aydoğdu
FIRAT ÜNİVERSİTESİ, FEN BİLİMLERİ ENSTİTÜSÜ
2 shared publications - Hakan Tutumlu
Gaziantep Üniversitesi, Naci Topçuoğlu Meslek Yüksekokulu
2 shared publications
Latest Publications
- 30 September 2026
- Published by Firat Universitesi in Fırat Üniversitesi Mühendislik Bilimleri Dergisi
- Vol. 38 (2) , 715-741
Parametrik Yaklaşım ile Farklı Betonarme Yapıların Enerji Performans Analizi
Bu çalışmada, Elazığ ili iklim şartları dikkate alınarak “Salt Perdeli” ve “Perde-Çerçeveli” olmak üzere iki farklı betonarme taşıyıcı sisteme sahip binanın ısıl enerji performansları ve çevresel etkileri karşılaştırmalı olarak analiz edilmiştir. Analizler Bin yöntemi ve DesignBuilder simülasyonu kullanılarak yapılmıştır. Her iki bina için verimlilik alternatifleri ve enerji analiz yöntemleri de bulgular üzerinden karşılaştırılarak değerlendirilmiştir. Bulgular, yalıtımsız ve mevcut durumda “Salt Perdeli” binanın daha fazla enerji tükettiğini; ancak TS 825’e uygun verimlilik senaryolarında “Perde-Çerçeveli” binanın daha yüksek saydamlık oranı nedeniyle daha fazla enerji harcadığını göstermektedir. Ayrıca Bin yöntemine göre mevcut binaya kıyasla “Salt Perdeli” binada %22.53’e kadar, “Perde-Çerçeveli” binada ise %7.45’e kadar enerji tasarrufu sağlanmıştır. DesignBuilder yöntemine göre ise bu oranlar sırasıyla %12.29 ve %8.75 olarak bulunmuştur.
- 30 September 2026
- Published by Firat Universitesi in Fırat Üniversitesi Mühendislik Bilimleri Dergisi
- Vol. 38 (2) , 715-741
Parametrik Yaklaşım ile Farklı Betonarme Yapıların Enerji Performans Analizi
Bu çalışmada, Elazığ ili iklim şartları dikkate alınarak “Salt Perdeli” ve “Perde-Çerçeveli” olmak üzere iki farklı betonarme taşıyıcı sisteme sahip binanın ısıl enerji performansları ve çevresel etkileri karşılaştırmalı olarak analiz edilmiştir. Analizler Bin yöntemi ve DesignBuilder simülasyonu kullanılarak yapılmıştır. Her iki bina için verimlilik alternatifleri ve enerji analiz yöntemleri de bulgular üzerinden karşılaştırılarak değerlendirilmiştir. Bulgular, yalıtımsız ve mevcut durumda “Salt Perdeli” binanın daha fazla enerji tükettiğini; ancak TS 825’e uygun verimlilik senaryolarında “Perde-Çerçeveli” binanın daha yüksek saydamlık oranı nedeniyle daha fazla enerji harcadığını göstermektedir. Ayrıca Bin yöntemine göre mevcut binaya kıyasla “Salt Perdeli” binada %22.53’e kadar, “Perde-Çerçeveli” binada ise %7.45’e kadar enerji tasarrufu sağlanmıştır. DesignBuilder yöntemine göre ise bu oranlar sırasıyla %12.29 ve %8.75 olarak bulunmuştur.
- Open Access
- 7 June 2022
- Published by Orclever Science and Research Group in The European Journal of Research and Development
- Vol. 2 (2) , 241-268
Energy Performance Analysis of Buildings in Terms of Alternative Reinforced Concrete Structural Systems
In this study, the thermal energy performances and environmental effects of two different reinforced concrete structures, Pure Shear Wall (PSW) Building and Shear Wall-Frame (SWF) Building, were investigated in the climatic conditions of Elazig province. Thermal performance analysis for both buildings; was carried out with the TS 825 program. First of all, through this program, monthly and annual heating loads were determined for 11 different alternative building component scenarios of two different buildings. Subsequently, efficiency alternatives were created in accordance with the climatic conditions of the region and TS 825. Efficiency alternatives designed for both buildings have been analyzed together with their completely uninsulated and current states. Finally, buildings with reinforced concrete carrier systems, energy analysis methods and efficiency alternatives were compared and evaluated based on the results of the analysis. As a result, it has been observed that the building with the PSW system consumes more energy than the building with the SWF system when it is uninsulated and in its current condition.
- 7 June 2022
- Published by Orclever Science and Research Group in The European Journal of Research and Development
- Vol. 2 (2) , 241-268
Open AccessEnergy Performance Analysis of Buildings in Terms of Alternative Reinforced Concrete Structural Systems
In this study, the thermal energy performances and environmental effects of two different reinforced concrete structures, Pure Shear Wall (PSW) Building and Shear Wall-Frame (SWF) Building, were investigated in the climatic conditions of Elazig province. Thermal performance analysis for both buildings; was carried out with the TS 825 program. First of all, through this program, monthly and annual heating loads were determined for 11 different alternative building component scenarios of two different buildings. Subsequently, efficiency alternatives were created in accordance with the climatic conditions of the region and TS 825. Efficiency alternatives designed for both buildings have been analyzed together with their completely uninsulated and current states. Finally, buildings with reinforced concrete carrier systems, energy analysis methods and efficiency alternatives were compared and evaluated based on the results of the analysis. As a result, it has been observed that the building with the PSW system consumes more energy than the building with the SWF system when it is uninsulated and in its current condition.
- 19 April 2019
- Published by Springer Nature in Arabian Journal for Science and Engineering
- Vol. 44 (9) , 7581-7597
ANN and ANFIS Approaches to Calculate the Heating and Cooling Degree Day Values: The Case of Provinces in Turkey
- 19 April 2019
- Published by Springer Nature in Arabian Journal for Science and Engineering
- Vol. 44 (9) , 7581-7597
ANN and ANFIS Approaches to Calculate the Heating and Cooling Degree Day Values: The Case of Provinces in Turkey
- 28 January 2011
- Published by Wiley in Environmental Progress & Sustainable Energy
- Vol. 30 (4) , 709-719
Application of three different methods for determination of optimum insulation thickness in external walls
- 28 January 2011
- Published by Wiley in Environmental Progress & Sustainable Energy
- Vol. 30 (4) , 709-719
Application of three different methods for determination of optimum insulation thickness in external walls
- 1 December 2010
- Published by Elsevier in Expert Systems with Applications
- Vol. 37 (12) , 8134-8147
ANN and ANFIS models for performance evaluation of a vertical ground source heat pump system
- 1 December 2010
- Published by Elsevier in Expert Systems with Applications
- Vol. 37 (12) , 8134-8147
ANN and ANFIS models for performance evaluation of a vertical ground source heat pump system
- 1 December 2009
- Published by Elsevier in Renewable Energy
- Vol. 34 (12) , 2672-2679
Temperature distributions in boreholes of a vertical ground-coupled heat pump system
- 1 December 2009
- Published by Elsevier in Renewable Energy
- Vol. 34 (12) , 2672-2679
Temperature distributions in boreholes of a vertical ground-coupled heat pump system
- 1 September 2009
- Published by Elsevier in Expert Systems with Applications
- Vol. 36 (7) , 10229-10238
Modelling of a vertical ground coupled heat pump system by using artificial neural networks
- 1 September 2009
- Published by Elsevier in Expert Systems with Applications
- Vol. 36 (7) , 10229-10238
Modelling of a vertical ground coupled heat pump system by using artificial neural networks
- 1 June 2009
- Published by Taylor & Francis in Journal of the Energy Institute
- Vol. 82 (2) , 95-101
Thermal response of ground for different depths on vertical ground source heat pump system in Elaziğ, Turkey
- 1 June 2009
- Published by Taylor & Francis in Journal of the Energy Institute
- Vol. 82 (2) , 95-101
Thermal response of ground for different depths on vertical ground source heat pump system in Elaziğ, Turkey
- 1 April 2009
- Published by Elsevier in Energy and Buildings
- Vol. 41 (4) , 395-401
In-situ thermal response test for ground source heat pump system in Elazığ, Turkey
- 1 April 2009
- Published by Elsevier in Energy and Buildings
- Vol. 41 (4) , 395-401
In-situ thermal response test for ground source heat pump system in Elazığ, Turkey