Vita N. Nikitina
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Vita N. Nikitina has a total of 67 co-authors. Here are the top co-authors by number of shared publications:
- Arkady A. Karyakin
Chemistry Faculty of M.V. Lomonosov Moscow State University, 119991, Moscow, Russia
13 shared publications Elena E. Karyakina
Chemistry Faculty of M. V. Lomonosov Moscow State University , 119991 , Moscow , Russia
6 shared publications- Anatoly K. Yatsimirsky
Universidad Nacional Autónoma de México
4 shared publications - Egor Andreev
M.V. Lomonosov Moscow State University Leninskie Gory, 1/3
4 shared publications - Ivan V. Mikheev
Department of Chemistry, Lomonosov Moscow State University, Moscow 119234, Russia
4 shared publications Arkady A. Karyakin
Chemistry Faculty of M.V. Lomonosov Moscow State University, 119991, Moscow, Russia
3 shared publications
Latest Publications
- 5 October 2026
- Published by Elsevier in Analytica Chimica Acta
- Vol. 1426
Conductometric process analytical technology for real-time endpoint control of graphene oxide dialysis purification
- 5 October 2026
- Published by Elsevier in Analytica Chimica Acta
- Vol. 1426
Conductometric process analytical technology for real-time endpoint control of graphene oxide dialysis purification
- 16 May 2026
- Published by Elsevier in Analytica Chimica Acta
- Vol. 1413, 345663
Tunable peroxyl radical scavenging by graphene oxide dispersions: a multiparametric chemiluminescence metric framework for comparison
- 16 May 2026
- Published by Elsevier in Analytica Chimica Acta
- Vol. 1413, 345663
Tunable peroxyl radical scavenging by graphene oxide dispersions: a multiparametric chemiluminescence metric framework for comparison
- Open Access
- 30 October 2025
- Published by MDPI AG in Preprints.org
Self-Recalibration of Prussian Blue Based (Bio)Sensors Enabling Their Prolonged Operation Time Upon Continuous Monitoring
We report on self-recalibration of Prussian Blue based (bio)sensors, which enables their prolonged operation time upon continuous chronoamperometric monitoring. Prussian Blue being the most advantageous electrocatalyst for H2O2, suffers from solubilization by the product of its reduction, hydroxyl ion (OH¯). Continuous monitoring is thus limited by operational stability under the hardest conditions possible. Self-recalibration is proposed to be carried out by periodic run of square-wave voltammograms directly in the analyzed medium providing prediction of (bio)sensor sensitivity with the root mean square error of prediction (RMSEP) of 5–7%. Since even 75-90% loss of the response does not hamper applicability of the Prussian Blue based (bio)sensors, the reported self-recalibration allows to prolong their operation 2.5–5 times avoiding interruption of continuous monitoring.
- 30 October 2025
- Published by MDPI AG in Preprints.org
Open AccessSelf-Recalibration of Prussian Blue Based (Bio)Sensors Enabling Their Prolonged Operation Time Upon Continuous Monitoring
We report on self-recalibration of Prussian Blue based (bio)sensors, which enables their prolonged operation time upon continuous chronoamperometric monitoring. Prussian Blue being the most advantageous electrocatalyst for H2O2, suffers from solubilization by the product of its reduction, hydroxyl ion (OH¯). Continuous monitoring is thus limited by operational stability under the hardest conditions possible. Self-recalibration is proposed to be carried out by periodic run of square-wave voltammograms directly in the analyzed medium providing prediction of (bio)sensor sensitivity with the root mean square error of prediction (RMSEP) of 5–7%. Since even 75-90% loss of the response does not hamper applicability of the Prussian Blue based (bio)sensors, the reported self-recalibration allows to prolong their operation 2.5–5 times avoiding interruption of continuous monitoring.
- 1 August 2025
- Published by Springer Nature in Russian Chemical Bulletin
- Vol. 74 (8) , 2392-2402
Three-component mediator biosensors based on lactate oxidase for the analysis of biological fluids
- 1 August 2025
- Published by Springer Nature in Russian Chemical Bulletin
- Vol. 74 (8) , 2392-2402
Three-component mediator biosensors based on lactate oxidase for the analysis of biological fluids
- Open Access
- 10 December 2024
- Published by American Chemical Society (ACS) in ChemRxiv
Green light activated dual-action Pt(IV) prodrug with enhanced PDT activity
Light induced release of cisplatin from Pt(IV) prodrugs is a promising tool for precise spatiotemporal control over the antiproliferative activity of Pt-based chemotherapeutic drugs. A combination of light-controlled chemotherapy (PACT) and photodynamic therapy (PDT) in one molecule has the potential to overcome crucial drawbacks of both Pt-based chemotherapy and PDT via synergetic effect. Herein we report green-light activated Pt(IV) prodrugs GreenPt with BODIPY-based photosentitizer in axial position with incredible high light response and singlet oxygen generation ability. GreenPt demonstrated the ability to release cisplatin under low-dose green light irradiation up to 1 J/cm2. The investigation of the photoreduction mechanism of GreenPt prodrug using DFT modeling and ΔG0 PET estimation revealed that the anion-radical formation and substituent photoinduced electron transfer from the triplet excited state of the BODIPY axial ligand to the Pt(IV) center is the key step in the light-induced release of cisplatin. Green-light activated BODIPY-based photosentitizers 5 and 8 demonstrated outstanding photosensitizing properties with extraordinary phototoxicity index (PI) >1300. GreenPt prodrug demonstrated gradual intracellular accumulation and light-induced phototoxicity with PI > 100, thus demonstrating dual action through light-controlled release of both cisplatin and a potent BODIPY-based photosensitizer.
- 10 December 2024
- Published by American Chemical Society (ACS) in ChemRxiv
Open AccessGreen light activated dual-action Pt(IV) prodrug with enhanced PDT activity
Light induced release of cisplatin from Pt(IV) prodrugs is a promising tool for precise spatiotemporal control over the antiproliferative activity of Pt-based chemotherapeutic drugs. A combination of light-controlled chemotherapy (PACT) and photodynamic therapy (PDT) in one molecule has the potential to overcome crucial drawbacks of both Pt-based chemotherapy and PDT via synergetic effect. Herein we report green-light activated Pt(IV) prodrugs GreenPt with BODIPY-based photosentitizer in axial position with incredible high light response and singlet oxygen generation ability. GreenPt demonstrated the ability to release cisplatin under low-dose green light irradiation up to 1 J/cm2. The investigation of the photoreduction mechanism of GreenPt prodrug using DFT modeling and ΔG0 PET estimation revealed that the anion-radical formation and substituent photoinduced electron transfer from the triplet excited state of the BODIPY axial ligand to the Pt(IV) center is the key step in the light-induced release of cisplatin. Green-light activated BODIPY-based photosentitizers 5 and 8 demonstrated outstanding photosensitizing properties with extraordinary phototoxicity index (PI) >1300. GreenPt prodrug demonstrated gradual intracellular accumulation and light-induced phototoxicity with PI > 100, thus demonstrating dual action through light-controlled release of both cisplatin and a potent BODIPY-based photosensitizer.
- Open Access
- 8 October 2024
- Published by MDPI AG in Biosensors
- Vol. 14 (10) , 486
Noninvasive Monitoring of Glycemia Level in Diabetic Patients by Wearable Advanced Biosensors
We report on the possibility of noninvasive diabetes monitoring through continuous analysis of sweat. The prediction of the blood glucose level in diabetic patients is possible on the basis of their sweat glucose content due to the positive correlation discovered. The ratio between the blood glucose and sweat glucose concentrations for a certain diabetic subject is stable within weeks, excluding requirements for frequent blood probing. The glucose variations in sweat display allometric (non-linear) dependence on those in blood, allowing more precise blood glucose estimation. Selective (avoiding false-positive responses) and sensitive (sweat glucose is on average 30–50 times lower) detection is possible with biosensors based on the glucose oxidase enzyme coupled with a Prussian Blue transducer. Reliable glucose detection in just secreted sweat would allow noninvasive monitoring of the glycemia level in diabetic patients.
- 8 October 2024
- Published by MDPI AG in Biosensors
- Vol. 14 (10) , 486
Open AccessNoninvasive Monitoring of Glycemia Level in Diabetic Patients by Wearable Advanced Biosensors
We report on the possibility of noninvasive diabetes monitoring through continuous analysis of sweat. The prediction of the blood glucose level in diabetic patients is possible on the basis of their sweat glucose content due to the positive correlation discovered. The ratio between the blood glucose and sweat glucose concentrations for a certain diabetic subject is stable within weeks, excluding requirements for frequent blood probing. The glucose variations in sweat display allometric (non-linear) dependence on those in blood, allowing more precise blood glucose estimation. Selective (avoiding false-positive responses) and sensitive (sweat glucose is on average 30–50 times lower) detection is possible with biosensors based on the glucose oxidase enzyme coupled with a Prussian Blue transducer. Reliable glucose detection in just secreted sweat would allow noninvasive monitoring of the glycemia level in diabetic patients.
- Open Access
Analytical Methods for Assessing Thiol Antioxidants in Biological Fluids: A Review
Redox metabolism is an integral part of the glutathione system, encompassing reduced and oxidized glutathione, hydrogen peroxide, and associated enzymes. This core process orchestrates a network of thiol antioxidants like thioredoxins and peroxiredoxins, alongside critical thiol-containing proteins such as mercaptoalbumin. Modifications to thiol-containing proteins, including oxidation and glutathionylation, regulate cellular signaling influencing gene activities in inflammation and carcinogenesis. Analyzing thiol antioxidants, especially glutathione, in biological fluids offers insights into pathological conditions. This review discusses the analytical methods for biothiol determination, mainly in blood plasma. The study includes all key methodological aspects of spectroscopy, chromatography, electrochemistry, and mass spectrometry, highlighting their principles, benefits, limitations, and recent advancements that were not included in previously published reviews. Sample preparation and factors affecting thiol antioxidant measurements are discussed. The review reveals that the choice of analytical procedures should be based on the specific requirements of the research. Spectrophotometric methods are simple and cost-effective but may need more specificity. Chromatographic techniques have excellent separation capabilities but require longer analysis times. Electrochemical methods enable real-time monitoring but have disadvantages such as interference. Mass spectrometry-based approaches have high sensitivity and selectivity but require sophisticated instrumentation. Combining multiple techniques can provide comprehensive information on thiol antioxidant levels in biological fluids, enabling clearer insights into their roles in health and disease. This review covers the time span from 2010 to mid-2024, and the data were obtained from the SciFinder® (ACS), Google Scholar (Google), PubMed®, and ScienceDirect (Scopus) databases through a combination search approach using keywords.
Open AccessAnalytical Methods for Assessing Thiol Antioxidants in Biological Fluids: A Review
Redox metabolism is an integral part of the glutathione system, encompassing reduced and oxidized glutathione, hydrogen peroxide, and associated enzymes. This core process orchestrates a network of thiol antioxidants like thioredoxins and peroxiredoxins, alongside critical thiol-containing proteins such as mercaptoalbumin. Modifications to thiol-containing proteins, including oxidation and glutathionylation, regulate cellular signaling influencing gene activities in inflammation and carcinogenesis. Analyzing thiol antioxidants, especially glutathione, in biological fluids offers insights into pathological conditions. This review discusses the analytical methods for biothiol determination, mainly in blood plasma. The study includes all key methodological aspects of spectroscopy, chromatography, electrochemistry, and mass spectrometry, highlighting their principles, benefits, limitations, and recent advancements that were not included in previously published reviews. Sample preparation and factors affecting thiol antioxidant measurements are discussed. The review reveals that the choice of analytical procedures should be based on the specific requirements of the research. Spectrophotometric methods are simple and cost-effective but may need more specificity. Chromatographic techniques have excellent separation capabilities but require longer analysis times. Electrochemical methods enable real-time monitoring but have disadvantages such as interference. Mass spectrometry-based approaches have high sensitivity and selectivity but require sophisticated instrumentation. Combining multiple techniques can provide comprehensive information on thiol antioxidant levels in biological fluids, enabling clearer insights into their roles in health and disease. This review covers the time span from 2010 to mid-2024, and the data were obtained from the SciFinder® (ACS), Google Scholar (Google), PubMed®, and ScienceDirect (Scopus) databases through a combination search approach using keywords.
- 29 July 2024
- Published by Elsevier in Journal of Electroanalytical Chemistry
- Vol. 970
Self-powered electromodulated liquid chromatography with preliminary charging of porous graphitic carbon
- 29 July 2024
- Published by Elsevier in Journal of Electroanalytical Chemistry
- Vol. 970
Self-powered electromodulated liquid chromatography with preliminary charging of porous graphitic carbon
- Open Access
- 25 September 2023
- Published by MDPI AG in Engineering Proceedings
- Vol. 48 (1) , 4
Amperometric Ion-Selective Electrodes Based on Prussian Blue Nanoparticles
We report amperometric solid-contact potassium-selective electrodes based on catalytically synthesized Prussian Blue nanoparticles. Both the films and nanoparticles were able to generate an amperometric response in the flow-injection mode under a constant potential. However, the nanoparticles provided a higher sensitivity than the films. Moreover, the intrinsic permeability of Prussian Blue for potassium ions allowed for selective detection of potassium in comparison to sodium even without an ion-selective membrane. The results of electrochemical impedance spectroscopy were used to manage the sensitivity by controlling the charge transfer resistance for ion-selective membranes of different density. By performing measurements in Bis-Tris as a carrier buffer containing no interfering cations, an additional increase in selectivity was enabled. A record selectivity coefficient logK Na+/K+ of −2.7 for the amperometric flow-injection mode was achieved. The obtained results indicate the prospects for analysis of biological fluids as the Na+/K+ ratio is approximately 20–40.
- 25 September 2023
- Published by MDPI AG in Engineering Proceedings
- Vol. 48 (1) , 4
Open AccessAmperometric Ion-Selective Electrodes Based on Prussian Blue Nanoparticles
We report amperometric solid-contact potassium-selective electrodes based on catalytically synthesized Prussian Blue nanoparticles. Both the films and nanoparticles were able to generate an amperometric response in the flow-injection mode under a constant potential. However, the nanoparticles provided a higher sensitivity than the films. Moreover, the intrinsic permeability of Prussian Blue for potassium ions allowed for selective detection of potassium in comparison to sodium even without an ion-selective membrane. The results of electrochemical impedance spectroscopy were used to manage the sensitivity by controlling the charge transfer resistance for ion-selective membranes of different density. By performing measurements in Bis-Tris as a carrier buffer containing no interfering cations, an additional increase in selectivity was enabled. A record selectivity coefficient logK Na+/K+ of −2.7 for the amperometric flow-injection mode was achieved. The obtained results indicate the prospects for analysis of biological fluids as the Na+/K+ ratio is approximately 20–40.