Laura Patricia Kaplan
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Laura Patricia Kaplan has a total of 98 co-authors. Here are the top co-authors by number of shared publications:
- Lone Hoffmann
Department of Oncology, Aarhus University Hospital, Aarhus, Denmark; Department of Clinical Medicine, Faculty of Health Sciences, Aarhus University, Aarhus, Denmark
5 shared publications - Ane Lindegaard Appelt
Department of Oncology, Centre for Cancer and Organ Diseases, Copenhagen University Hospital - Rigshospitalet, Copenhagen, Denmark; Department of Health Technology, Technical University of Denmark, Copenhagen, Denmark
4 shared publications - Mikkel Drøgemüller Lund
Department of Oncology, Vejle Hospital, University Hospital of Southern Denmark, Vejle, Denmark
4 shared publications - Kenneth Jensen
Danish Centre for Particle Therapy, Aarhus University Hospital, Denmark
3 shared publications - Laura Ann Rechner
Department of Oncology, Radiotherapy Research Unit, Copenhagen University Hospital - Herlev and Gentofte, Herlev, Denmark
3 shared publications - Martin Skovmos Nielsen
Department of Oncology, Clinical Cancer Research Center, Aalborg University Hospital, Aalborg, Denmark
3 shared publications
Latest Publications
- Open Access
- 17 July 2026
- Published by Elsevier in Radiotherapy and Oncology
- Vol. 222, 111702
Multi-centre generalisability of deep learning-based dose prediction for head and neck radiotherapy using DAHANCA real-world data
- 17 July 2026
- Published by Elsevier in Radiotherapy and Oncology
- Vol. 222, 111702
Open AccessMulti-centre generalisability of deep learning-based dose prediction for head and neck radiotherapy using DAHANCA real-world data
- Open Access
- 19 May 2026
- Published by Elsevier in Clinical Oncology
- Vol. 55, 104190
Multicenter Study of Dose Accumulation for Reirradiation: Intercenter Variation in Radiobiological Dose Scaling Introduces Clinically Relevant Differences
- 19 May 2026
- Published by Elsevier in Clinical Oncology
- Vol. 55, 104190
Open AccessMulticenter Study of Dose Accumulation for Reirradiation: Intercenter Variation in Radiobiological Dose Scaling Introduces Clinically Relevant Differences
- Open Access
- 20 November 2025
- Published by Elsevier in Radiotherapy and Oncology
- Vol. 214, 111293
Development of a treatment planning protocol for the multi-centre reirradiation CURE Lung trial
- 20 November 2025
- Published by Elsevier in Radiotherapy and Oncology
- Vol. 214, 111293
Open AccessDevelopment of a treatment planning protocol for the multi-centre reirradiation CURE Lung trial
- Open Access
- 24 July 2025
- Published by Medical Journals Sweden AB in Acta Oncologica
- Vol. 64, 946-956
Clinical workflow for reirradiation: national consensus recommendations on imaging, treatment planning, dose accumulation, and treatment delivery
Background and purpose: Reirradiation is becoming more frequent in clinical practice. However, workflows and practices vary widely between clinics, as general guidelines are scarce or lacking in practical detail. This paper presents comprehensive national Danish consensus recommendations covering all steps of the reirradiation workflow. The aim is to standardise and improve reirradiation treatment quality and provide guidance for much-needed large-scale clinical trials. Methods: An expert panel was formed comprising physicians, clinical physicists, and clinical researchers from all Danish radiotherapy centres. An in-person 2-day workshop was followed by multiple online meetings. Recommendations were based on expert consensus, supported by review of existing literature, and were reviewed by all Danish Multidisciplinary Cancer Groups before publication. Results: Reirradiation cases should be designated clearly as such at each workflow step. Review of patient cases at multidisciplinary reirradiation conferences is encouraged. Immobilisation, positioning, and motion management should resemble that of previous treatment(s) as closely as possible. Information on previous dose should be used in planning and evaluation. The degree of complexity (e.g. summation of dose maxima, rigid/deformable image registration, 3D dose accumulation) should reflect the clinical situation as well as the extent/quality of available information. Dose should always be converted to an equieffective dose before summation. Daily image-guidance and regular evaluation of delivered dose are recommended. We provide guidance on quality assurance of dose mapping and guidelines for clinical reirradiation trials. Interpretation: We present national consensus guidelines for site-independent reirradiation treatment workflows. The guidelines have been approved by the site-specific Danish Multidisciplinary Cancer Groups.
- 24 July 2025
- Published by Medical Journals Sweden AB in Acta Oncologica
- Vol. 64, 946-956
Open AccessClinical workflow for reirradiation: national consensus recommendations on imaging, treatment planning, dose accumulation, and treatment delivery
Background and purpose: Reirradiation is becoming more frequent in clinical practice. However, workflows and practices vary widely between clinics, as general guidelines are scarce or lacking in practical detail. This paper presents comprehensive national Danish consensus recommendations covering all steps of the reirradiation workflow. The aim is to standardise and improve reirradiation treatment quality and provide guidance for much-needed large-scale clinical trials. Methods: An expert panel was formed comprising physicians, clinical physicists, and clinical researchers from all Danish radiotherapy centres. An in-person 2-day workshop was followed by multiple online meetings. Recommendations were based on expert consensus, supported by review of existing literature, and were reviewed by all Danish Multidisciplinary Cancer Groups before publication. Results: Reirradiation cases should be designated clearly as such at each workflow step. Review of patient cases at multidisciplinary reirradiation conferences is encouraged. Immobilisation, positioning, and motion management should resemble that of previous treatment(s) as closely as possible. Information on previous dose should be used in planning and evaluation. The degree of complexity (e.g. summation of dose maxima, rigid/deformable image registration, 3D dose accumulation) should reflect the clinical situation as well as the extent/quality of available information. Dose should always be converted to an equieffective dose before summation. Daily image-guidance and regular evaluation of delivered dose are recommended. We provide guidance on quality assurance of dose mapping and guidelines for clinical reirradiation trials. Interpretation: We present national consensus guidelines for site-independent reirradiation treatment workflows. The guidelines have been approved by the site-specific Danish Multidisciplinary Cancer Groups.
- Open Access
- 9 July 2025
- Published by Medical Journals Sweden AB in Acta Oncologica
- Vol. 64, 872-878
A comprehensive national audit of radiotherapy retreatment numbers, sites and indications
Background and purpose: Reirradiation has seen increased interest and clinical use; however, robust data on patient numbers and treatment indications are missing. As a precursor to a prospective national reirradiation registry, a comprehensive national audit of reirradiation was performed. Patients/materials and methods: Radiotherapy retreatment courses in 2023 were audited by all (eight) radiotherapy centres in Denmark. Six centres extended the evaluation to include 2021–22, and three of these also evaluated preceding years. Reirradiation was defined according to the ESTRO/EORTC consensus (i.e. treatment volume overlap or cumulative dose toxicity risk) using 3 months threshold between the primary and reirradiation courses. Reirradiation courses were further stratified into curative/ablative and palliative treatments by prescription dose. Results: The total number of radiotherapy patients at Danish centres in 2023 was 17,424. Of these, 3,163 received retreatment, including 1,471 reirradiation courses (1,035 palliative; 436 curative/ablative). From 2014 to 2023, absolute numbers for both retreatment and reirradiation increased. We found large variation in prescription doses and fractionation schedules used for reirradiation. Widely used palliative prescriptions were 8Gy/1 fraction (F), 20Gy/4F and 30Gy/10F; stereotactic prescriptions of 20Gy/1F or 27Gy/3F in brain and 45Gy/3F in lung; and a variety of curative treatments schedules. Palliative reirradiations were primarily thoracic (29%), spine (25%), and abdominal/pelvic (22%) and curative/ablative reirradiations were primarily breast (29%) and lung stereotactic (23%). Interpretation: This is the first comprehensive national audit of reirradiation, demonstrating an increasing number of patients being treated, using a wide variety of dose prescriptions and fractionation schedules.
- 9 July 2025
- Published by Medical Journals Sweden AB in Acta Oncologica
- Vol. 64, 872-878
Open AccessA comprehensive national audit of radiotherapy retreatment numbers, sites and indications
Background and purpose: Reirradiation has seen increased interest and clinical use; however, robust data on patient numbers and treatment indications are missing. As a precursor to a prospective national reirradiation registry, a comprehensive national audit of reirradiation was performed. Patients/materials and methods: Radiotherapy retreatment courses in 2023 were audited by all (eight) radiotherapy centres in Denmark. Six centres extended the evaluation to include 2021–22, and three of these also evaluated preceding years. Reirradiation was defined according to the ESTRO/EORTC consensus (i.e. treatment volume overlap or cumulative dose toxicity risk) using 3 months threshold between the primary and reirradiation courses. Reirradiation courses were further stratified into curative/ablative and palliative treatments by prescription dose. Results: The total number of radiotherapy patients at Danish centres in 2023 was 17,424. Of these, 3,163 received retreatment, including 1,471 reirradiation courses (1,035 palliative; 436 curative/ablative). From 2014 to 2023, absolute numbers for both retreatment and reirradiation increased. We found large variation in prescription doses and fractionation schedules used for reirradiation. Widely used palliative prescriptions were 8Gy/1 fraction (F), 20Gy/4F and 30Gy/10F; stereotactic prescriptions of 20Gy/1F or 27Gy/3F in brain and 45Gy/3F in lung; and a variety of curative treatments schedules. Palliative reirradiations were primarily thoracic (29%), spine (25%), and abdominal/pelvic (22%) and curative/ablative reirradiations were primarily breast (29%) and lung stereotactic (23%). Interpretation: This is the first comprehensive national audit of reirradiation, demonstrating an increasing number of patients being treated, using a wide variety of dose prescriptions and fractionation schedules.
- Open Access
- 15 September 2023
- Published by Medical Journals Sweden AB in Acta Oncologica
- Vol. 62 (11) , 1451-1454
A systematic planning method to spare the rectal wall in radiotherapy of prostate cancer
- 15 September 2023
- Published by Medical Journals Sweden AB in Acta Oncologica
- Vol. 62 (11) , 1451-1454
Open AccessA systematic planning method to spare the rectal wall in radiotherapy of prostate cancer
- Open Access
- 14 June 2022
- Published by Elsevier in Radiotherapy and Oncology
- Vol. 173, 254-261
Plan quality assessment in clinical practice: Results of the 2020 ESTRO survey on plan complexity and robustness
- 14 June 2022
- Published by Elsevier in Radiotherapy and Oncology
- Vol. 173, 254-261
Open AccessPlan quality assessment in clinical practice: Results of the 2020 ESTRO survey on plan complexity and robustness
- Open Access
- 1 July 2018
- Published by Elsevier in Physics and Imaging in Radiation Oncology
- Vol. 7, 45-50
Cone beam CT based dose calculation in the thorax region
- 1 July 2018
- Published by Elsevier in Physics and Imaging in Radiation Oncology
- Vol. 7, 45-50
Open AccessCone beam CT based dose calculation in the thorax region
- 14 June 2017
- Published by IOP Publishing in Physics in Medicine & Biology
- Vol. 62 (14) , 5612-5622
Determining the mechanical properties of a radiochromic silicone-based 3D dosimeter
New treatment modalities in radiotherapy (RT) enable delivery of highly conformal dose distributions in patients. This creates a need for precise dose verification in three dimensions (3D). A radiochromic silicone-based 3D dosimetry system has recently been developed. Such a dosimeter can be used for dose verification in deformed geometries, which requires knowledge of the dosimeter’s mechanical properties. In this study we have characterized the dosimeter’s elastic behaviour under tensile and compressive stress. In addition, the dose response under strain was determined. It was found that the dosimeter behaved as an incompressible hyperelastic material with a non-linear stress/strain curve and with no observable hysteresis or plastic deformation even at high strains. The volume was found to be constant within a 2% margin at deformations up to 60%. Furthermore, it was observed that the dosimeter returned to its original geometry within a 2% margin when irradiated under stress, and that the change in optical density per centimeter was constant regardless of the strain during irradiation. In conclusion, we have shown that this radiochromic silicone-based dosimeter’s mechanical properties make it a viable candidate for dose verification in deformable 3D geometries.
- 14 June 2017
- Published by IOP Publishing in Physics in Medicine & Biology
- Vol. 62 (14) , 5612-5622
Determining the mechanical properties of a radiochromic silicone-based 3D dosimeter
New treatment modalities in radiotherapy (RT) enable delivery of highly conformal dose distributions in patients. This creates a need for precise dose verification in three dimensions (3D). A radiochromic silicone-based 3D dosimetry system has recently been developed. Such a dosimeter can be used for dose verification in deformed geometries, which requires knowledge of the dosimeter’s mechanical properties. In this study we have characterized the dosimeter’s elastic behaviour under tensile and compressive stress. In addition, the dose response under strain was determined. It was found that the dosimeter behaved as an incompressible hyperelastic material with a non-linear stress/strain curve and with no observable hysteresis or plastic deformation even at high strains. The volume was found to be constant within a 2% margin at deformations up to 60%. Furthermore, it was observed that the dosimeter returned to its original geometry within a 2% margin when irradiated under stress, and that the change in optical density per centimeter was constant regardless of the strain during irradiation. In conclusion, we have shown that this radiochromic silicone-based dosimeter’s mechanical properties make it a viable candidate for dose verification in deformable 3D geometries.