Daniel Cussol
Research Subjects
Research Interests
Daniel Cussol has a total of 515 co-authors. Here are the top co-authors by number of shared publications:
E. Rosato
Dipartimento di Scienze Fisiche e Sezione INFN, Università di Napoli “Federico II”, I-80126 Napoli, Italy
52 shared publicationsB. Tamain
LPC, CNRS/IN2P3, ENSICAEN, Université de Caen, F-14050 Caen cedex, France
50 shared publicationsF. Saint-Laurent
44 shared publicationsJ. Colin
LPC-Caen, ENSICAEN, Université de Caen Normandie, CNRS/IN2P3, Caen, France
44 shared publicationsE. Vient
LPC, CNRS/IN2P3, ENSICAEN, Université de Caen, F-14050 Caen cedex, France
43 shared publicationsR. Brou
43 shared publications
Latest Publications
- Open Access
- 13 September 2017
- Published by EDP Sciences in EPJ Web of Conferences
- Vol. 146, 08005
Differential cross-sections measurements for hadrontherapy: 50 MeV/A12C reactions on H, C, O, Al andnatTi targets
EPJ Web of Conferences, open-access proceedings in physics and astronomy
- 13 September 2017
- Published by EDP Sciences in EPJ Web of Conferences
- Vol. 146, 08005
Open AccessDifferential cross-sections measurements for hadrontherapy: 50 MeV/A12C reactions on H, C, O, Al andnatTi targets
EPJ Web of Conferences, open-access proceedings in physics and astronomy
- 1 June 2017
- Published by Elsevier in Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment
- Vol. 856, 1-6
Characterization and performances of DOSION, a dosimetry equipment dedicated to radiobiology experiments taking place at GANIL
- 1 June 2017
- Published by Elsevier in Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment
- Vol. 856, 1-6
Characterization and performances of DOSION, a dosimetry equipment dedicated to radiobiology experiments taking place at GANIL
- 11 April 2017
- Published by American Physical Society (APS) in Physical Review C
- Vol. 95 (4)
Cross section measurements for production of positron emitters for PET imaging in carbon therapy
- 11 April 2017
- Published by American Physical Society (APS) in Physical Review C
- Vol. 95 (4)
Cross section measurements for production of positron emitters for PET imaging in carbon therapy
- 4 April 2017
- Published by American Physical Society (APS) in Physical Review C
- Vol. 95 (4) , 044602
Differential cross section measurements for hadron therapy: 50 MeV/nucleon reactions on H, C, O, Al, and targetsDuring a carbon therapy treatment, the beam undergoes inelastic nuclear reactions leading to the production of secondary fragments. These nuclear interactions tend to delocate a part of the dose into healthy tissues and create a mixed radiation field. In order to accurately estimate the dose deposited into the tissues, the production rate of these fragments all along the beam path have to be taken into account. But the double differential carbon fragmentation cross sections are not well known in the energy range needed for a treatment (up to 400 MeV/nucleon). Therefore, a series of experiments aiming to measure the double differential fragmentation cross sections of carbon on thin targets of medical interest has been started by our collaboration. In March 2015 we performed an experiment to study the fragmentation of a 50 MeV/nucleon beam on thin targets at GANIL. During this experiment, energy and angular cross-section distributions on H, C, O, Al, and have been measured. The experimental set-up will be detailed as well as the systematic error study and all the experimental results will be presented.- 4 April 2017
- Published by American Physical Society (APS) in Physical Review C
- Vol. 95 (4) , 044602
Differential cross section measurements for hadron therapy: 50 MeV/nucleon reactions on H, C, O, Al, and targetsDuring a carbon therapy treatment, the beam undergoes inelastic nuclear reactions leading to the production of secondary fragments. These nuclear interactions tend to delocate a part of the dose into healthy tissues and create a mixed radiation field. In order to accurately estimate the dose deposited into the tissues, the production rate of these fragments all along the beam path have to be taken into account. But the double differential carbon fragmentation cross sections are not well known in the energy range needed for a treatment (up to 400 MeV/nucleon). Therefore, a series of experiments aiming to measure the double differential fragmentation cross sections of carbon on thin targets of medical interest has been started by our collaboration. In March 2015 we performed an experiment to study the fragmentation of a 50 MeV/nucleon beam on thin targets at GANIL. During this experiment, energy and angular cross-section distributions on H, C, O, Al, and have been measured. The experimental set-up will be detailed as well as the systematic error study and all the experimental results will be presented.- 1 October 2016
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-2
Timing performances of a time-of-flight detection system for fragmentation cross section measurements in carbon therapy
Carbon ions therapy is being considered to replace proton therapy in the treatment of certain cancerous diseases due to a better ballistic and a higher relative biological effectiveness (RBE). However, nuclear interactions between beam particles and nuclei in the tissues reduce the primary beam intensity at the Bragg peak and create a mixed radiation field through lighter and faster fragments.
- 1 October 2016
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-2
Timing performances of a time-of-flight detection system for fragmentation cross section measurements in carbon therapy
Carbon ions therapy is being considered to replace proton therapy in the treatment of certain cancerous diseases due to a better ballistic and a higher relative biological effectiveness (RBE). However, nuclear interactions between beam particles and nuclei in the tissues reduce the primary beam intensity at the Bragg peak and create a mixed radiation field through lighter and faster fragments.
- Open Access
- 19 June 2015
- Published by IOP Publishing in Physics Education
- Vol. 50 (4) , 453-461
The Billotron: a way to experimentally apprehend the subatomic world
The Billotron is a device designed and built by the LPC Caen to illustrate the methods with which physicists are able to study the basic structure of matter, in particular the nucleus of the atom.
- 19 June 2015
- Published by IOP Publishing in Physics Education
- Vol. 50 (4) , 453-461
Open AccessThe Billotron: a way to experimentally apprehend the subatomic world
The Billotron is a device designed and built by the LPC Caen to illustrate the methods with which physicists are able to study the basic structure of matter, in particular the nucleus of the atom.
- 30 June 2014
- Published by American Physical Society (APS) in Physical Review C
- Vol. 89 (6)
Erratum: Double-differential fragmentation cross-section measurements of 95 MeV/nucleonbeams on thin targets for hadron therapy [Phys. Rev. C88, 024606 (2013)]DOI: http://dx.doi.org/10.1103/PhysRevC.89.069904 ©2014 American Physical Society
- 30 June 2014
- Published by American Physical Society (APS) in Physical Review C
- Vol. 89 (6)
Erratum: Double-differential fragmentation cross-section measurements of 95 MeV/nucleonbeams on thin targets for hadron therapy [Phys. Rev. C88, 024606 (2013)]DOI: http://dx.doi.org/10.1103/PhysRevC.89.069904 ©2014 American Physical Society
- 30 June 2014
- Published by American Physical Society (APS) in Physical Review C
- Vol. 89 (6)
Zero-degree measurements offragmentation at 95 MeV/nucleon on thin targetsDuring therapeutic treatments using ions such as carbon, nuclear interactions between the incident ions and nuclei present in organic tissues may occur, leading to the attenuation of the incident beam intensity and to the production of secondary light charged particles. As the biological dose deposited in the tumor and the surrounding healthy tissues depends on the beam composition, an accurate knowledge of the fragmentation processes is thus essential. In particular, the nuclear interaction models have to be validated using experimental double differential cross sections which are still very scarce. An experiment was realized in 2011 at GANIL to obtain these cross sections for a 95-MeV/nucleon carbon beam on different thin targets for angles raging from 4${}^{$\circ${}}$ to 43${}^{$\circ${}}$. To complete these data, a new experiment was performed in September 2013 at GANIL to measure the fragmentation cross section at zero degree for a 95-MeV/nucleon carbon beam on thin targets. In this work, the experimental setup will be described, the analysis method detailed, and the results presented.
- 30 June 2014
- Published by American Physical Society (APS) in Physical Review C
- Vol. 89 (6)
Zero-degree measurements offragmentation at 95 MeV/nucleon on thin targetsDuring therapeutic treatments using ions such as carbon, nuclear interactions between the incident ions and nuclei present in organic tissues may occur, leading to the attenuation of the incident beam intensity and to the production of secondary light charged particles. As the biological dose deposited in the tumor and the surrounding healthy tissues depends on the beam composition, an accurate knowledge of the fragmentation processes is thus essential. In particular, the nuclear interaction models have to be validated using experimental double differential cross sections which are still very scarce. An experiment was realized in 2011 at GANIL to obtain these cross sections for a 95-MeV/nucleon carbon beam on different thin targets for angles raging from 4${}^{$\circ${}}$ to 43${}^{$\circ${}}$. To complete these data, a new experiment was performed in September 2013 at GANIL to measure the fragmentation cross section at zero degree for a 95-MeV/nucleon carbon beam on thin targets. In this work, the experimental setup will be described, the analysis method detailed, and the results presented.
- Open Access
- 29 May 2014
- Published by American Physical Society (APS) in Physical Review C
- Vol. 89 (5)
Benchmarking geant4 nuclear models for hadron therapy with 95 MeV/nucleon carbon ions
In carbon therapy, the interaction of the incoming beam with human tissue may lead to the production of a large amount of nuclear fragments and secondary light particles. An accurate estimation of the biological dose on the tumor and the surrounding healthy tissue thus requires sophisticated simulation tools based on nuclear reaction models. The validity of such models requires intensive comparisons with as many sets of experimental data as possible. Up to now, a rather limited set of double differential carbon fragmentation cross sections has been measured in the energy range used in hadron therapy (up to 400 MeV/nucleon). However, new data have been recently obtained at intermediate energy (95 MeV/nucleon). The aim of this work is to compare the reaction models embedded in the geant4 Monte Carlo toolkit with these new data. The strengths and weaknesses of each tested model, i.e., G4BinaryLightIonReaction, G4QMDReaction, and INCL++, coupled to two different de-excitation models, i.e., the generalized evaporation model and the Fermi break-up model, are discussed.
- 29 May 2014
- Published by American Physical Society (APS) in Physical Review C
- Vol. 89 (5)
Open AccessBenchmarking geant4 nuclear models for hadron therapy with 95 MeV/nucleon carbon ions
In carbon therapy, the interaction of the incoming beam with human tissue may lead to the production of a large amount of nuclear fragments and secondary light particles. An accurate estimation of the biological dose on the tumor and the surrounding healthy tissue thus requires sophisticated simulation tools based on nuclear reaction models. The validity of such models requires intensive comparisons with as many sets of experimental data as possible. Up to now, a rather limited set of double differential carbon fragmentation cross sections has been measured in the energy range used in hadron therapy (up to 400 MeV/nucleon). However, new data have been recently obtained at intermediate energy (95 MeV/nucleon). The aim of this work is to compare the reaction models embedded in the geant4 Monte Carlo toolkit with these new data. The strengths and weaknesses of each tested model, i.e., G4BinaryLightIonReaction, G4QMDReaction, and INCL++, coupled to two different de-excitation models, i.e., the generalized evaporation model and the Fermi break-up model, are discussed.
- 1 February 2014
- Published by Elsevier in Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment
- Vol. 736, 112-117
Characterization and performances of a monitoring ionization chamber dedicated to IBA-universal irradiation head for Pencil Beam Scanning
- 1 February 2014
- Published by Elsevier in Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment
- Vol. 736, 112-117
Characterization and performances of a monitoring ionization chamber dedicated to IBA-universal irradiation head for Pencil Beam Scanning