Souichi Telada
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Souichi Telada has a total of 976 co-authors. Here are the top co-authors by number of shared publications:
- Kazuhiro Yamamoto
Institute for Cosmic Ray Research, The University of Tokyo, Kashiwa, Chiba 277-8582, Japan
24 shared publications - Masaki Ando
The University of Tokyo
23 shared publications Masatake Ohashi
18 shared publicationsDaisuke Tatsumi
17 shared publications- Koji Arai
California Institute of Technology
17 shared publications Masa-Katsu Fujimoto
13 shared publications
Latest Publications
- Open Access
- 1 January 2018
- Published by Oxford University Press (OUP) in Progress of Theoretical and Experimental Physics
- Vol. 2018 (1)
Construction of KAGRA: an underground gravitational-wave observatory
The major construction and initial-phase operation of a second-generation gravitational-wave detector, KAGRA, has been completed. The entire 3 km detector is installed underground in a mine in order to be isolated from background seismic vibrations on the surface. This allows us to achieve a good sensitivity at low frequencies and high stability of the detector. Bare-bones equipment for the interferometer operation has been installed and the first test run was accomplished in March and April of 2016 with a rather simple configuration. The initial configuration of KAGRA is called iKAGRA. In this paper, we summarize the construction of KAGRA, including a study of the advantages and challenges of building an underground detector, and the operation of the iKAGRA interferometer together with the geophysics interferometer that has been constructed in the same tunnel.
- 1 January 2018
- Published by Oxford University Press (OUP) in Progress of Theoretical and Experimental Physics
- Vol. 2018 (1)
Open AccessConstruction of KAGRA: an underground gravitational-wave observatory
The major construction and initial-phase operation of a second-generation gravitational-wave detector, KAGRA, has been completed. The entire 3 km detector is installed underground in a mine in order to be isolated from background seismic vibrations on the surface. This allows us to achieve a good sensitivity at low frequencies and high stability of the detector. Bare-bones equipment for the interferometer operation has been installed and the first test run was accomplished in March and April of 2016 with a rather simple configuration. The initial configuration of KAGRA is called iKAGRA. In this paper, we summarize the construction of KAGRA, including a study of the advantages and challenges of building an underground detector, and the operation of the iKAGRA interferometer together with the geophysics interferometer that has been constructed in the same tunnel.
- 1 September 2013
- Published by AIP Publishing in Review of Scientific Instruments
- Vol. 84 (9) , 093302
Propagation and stability characteristics of a 500-m-long laser-based fiducial line for high-precision alignment of long-distance linear accelerators
A laser-based alignment system with a He-Ne laser has been newly developed in order to precisely align accelerator units at the KEKB injector linac. The laser beam was first implemented as a 500-m-long fiducial straight line for alignment measurements. We experimentally investigated the propagation and stability characteristics of the laser beam passing through laser pipes in vacuum. The pointing stability at the last fiducial point was successfully obtained with the transverse displacements of ±40 μm level in one standard deviation by applying a feedback control. This pointing stability corresponds to an angle of ±0.08 μrad. This report contains a detailed description of the experimental investigation for the propagation and stability characteristics of the laser beam in the laser-based alignment system for long-distance linear accelerators.
- 1 September 2013
- Published by AIP Publishing in Review of Scientific Instruments
- Vol. 84 (9) , 093302
Propagation and stability characteristics of a 500-m-long laser-based fiducial line for high-precision alignment of long-distance linear accelerators
A laser-based alignment system with a He-Ne laser has been newly developed in order to precisely align accelerator units at the KEKB injector linac. The laser beam was first implemented as a 500-m-long fiducial straight line for alignment measurements. We experimentally investigated the propagation and stability characteristics of the laser beam passing through laser pipes in vacuum. The pointing stability at the last fiducial point was successfully obtained with the transverse displacements of ±40 μm level in one standard deviation by applying a feedback control. This pointing stability corresponds to an angle of ±0.08 μrad. This report contains a detailed description of the experimental investigation for the propagation and stability characteristics of the laser beam in the laser-based alignment system for long-distance linear accelerators.
- 1 May 2012
- Published by AIP Publishing in Review of Scientific Instruments
- Vol. 83 (5) , 053301
Experimental investigation on focusing characteristics of a He-Ne laser using circular Fresnel zone plate for high-precision alignment of linear accelerators
We experimentally investigate the focusing characteristics of a He–Ne laser at the focal region for the high-precision alignment of long-distance linear accelerators using a circular Fresnel zone plate. The laser wave passing through the Fresnel zone plate having a focal length of 66.7 m propagates for a 268-m-long distance at atmospheric pressure. A new laser-based alignment system using Fresnel zone plates as the alignment targets is discussed. The transverse displacement of the focused spot of the laser is measured as a function of the displacement of the target by a detector installed at the focal point. Systematic studies on the focusing characteristics and alignment precision have been successfully conducted in this experiment. The experimental results are in good agreement with theoretical calculations, and the alignment precision of the target is determined to be less than ±30 μm. In this study, we perform a detailed experimental investigation on the laser propagation and focusing characteristics using the circular Fresnel zone plate at the focal region along with theoretical calculations.
- 1 May 2012
- Published by AIP Publishing in Review of Scientific Instruments
- Vol. 83 (5) , 053301
Experimental investigation on focusing characteristics of a He-Ne laser using circular Fresnel zone plate for high-precision alignment of linear accelerators
We experimentally investigate the focusing characteristics of a He–Ne laser at the focal region for the high-precision alignment of long-distance linear accelerators using a circular Fresnel zone plate. The laser wave passing through the Fresnel zone plate having a focal length of 66.7 m propagates for a 268-m-long distance at atmospheric pressure. A new laser-based alignment system using Fresnel zone plates as the alignment targets is discussed. The transverse displacement of the focused spot of the laser is measured as a function of the displacement of the target by a detector installed at the focal point. Systematic studies on the focusing characteristics and alignment precision have been successfully conducted in this experiment. The experimental results are in good agreement with theoretical calculations, and the alignment precision of the target is determined to be less than ±30 μm. In this study, we perform a detailed experimental investigation on the laser propagation and focusing characteristics using the circular Fresnel zone plate at the focal region along with theoretical calculations.
- 3 April 2012
- Published by American Physical Society (APS) in Physical Review Letters
- Vol. 108 (14) , 141101
Reduction of Thermal Fluctuations in a Cryogenic Laser Interferometric Gravitational Wave Detector
The thermal fluctuation of mirror surfaces is the fundamental limitation for interferometric gravitational wave (GW) detectors. Here, we experimentally demonstrate for the first time a reduction in a mirror's thermal fluctuation in a GW detector with sapphire mirrors from the Cryogenic Laser Interferometer Observatory at 17 and 18~K. The detector sensitivity, which was limited by the mirror's thermal fluctuation at room temperature, was improved in the frequency range of 90 to 240~Hz by cooling the mirrors. The improved sensitivity reached a maximum of 2.2\ifmmode\times\else\texttimes\fi{}10-19\,\,m/Hz at 165~Hz.
- 3 April 2012
- Published by American Physical Society (APS) in Physical Review Letters
- Vol. 108 (14) , 141101
Reduction of Thermal Fluctuations in a Cryogenic Laser Interferometric Gravitational Wave Detector
The thermal fluctuation of mirror surfaces is the fundamental limitation for interferometric gravitational wave (GW) detectors. Here, we experimentally demonstrate for the first time a reduction in a mirror's thermal fluctuation in a GW detector with sapphire mirrors from the Cryogenic Laser Interferometer Observatory at 17 and 18~K. The detector sensitivity, which was limited by the mirror's thermal fluctuation at room temperature, was improved in the frequency range of 90 to 240~Hz by cooling the mirrors. The improved sensitivity reached a maximum of 2.2\ifmmode\times\else\texttimes\fi{}10-19\,\,m/Hz at 165~Hz.
- 21 September 2010
- Published by Optica Publishing Group in Applied Optics
- Vol. 49 (28) , 5217-5225
Expansion of linear range of Pound-Drever-Hall signal
We propose new solutions for expanding the linear signal range between the laser frequency deviation (or mirror position) and the voltage signal derived by the Pound-Drever-Hall (PDH) method for optical Fabry–Perot cavity resonance control. One solution is to perform not in-phase demodulation but near-Q-phase demodulation. Another solution is to take a suitable combination of signals demodulated by odd-harmonic modulation frequencies in the in phase. Although the PDH signal sensitivity will be diminished, the PDH signal linear range can be extended. From a practical standpoint, it is desirable that a sideband frequency for the PDH method is near the FP cavity resonance.
- 21 September 2010
- Published by Optica Publishing Group in Applied Optics
- Vol. 49 (28) , 5217-5225
Expansion of linear range of Pound-Drever-Hall signal
We propose new solutions for expanding the linear signal range between the laser frequency deviation (or mirror position) and the voltage signal derived by the Pound-Drever-Hall (PDH) method for optical Fabry–Perot cavity resonance control. One solution is to perform not in-phase demodulation but near-Q-phase demodulation. Another solution is to take a suitable combination of signals demodulated by odd-harmonic modulation frequencies in the in phase. Although the PDH signal sensitivity will be diminished, the PDH signal linear range can be extended. From a practical standpoint, it is desirable that a sideband frequency for the PDH method is near the FP cavity resonance.
- 6 April 2010
- Published by IOP Publishing in Classical and Quantum Gravity
- Vol. 27 (8)
Thermal-noise-limited underground interferometer CLIO
- 6 April 2010
- Published by IOP Publishing in Classical and Quantum Gravity
- Vol. 27 (8)
Thermal-noise-limited underground interferometer CLIO
- Open Access
- 2 April 2010
- Published by Oxford University Press (OUP) in Geophysical Journal International
- Vol. 181 (1) , 127-140
Analyses of far-field coseismic crustal deformation observed by a new laser distance measurement system
- 2 April 2010
- Published by Oxford University Press (OUP) in Geophysical Journal International
- Vol. 181 (1) , 127-140
Open AccessAnalyses of far-field coseismic crustal deformation observed by a new laser distance measurement system
- Open Access
- 28 January 2010
- Published by American Physical Society (APS) in Physical Review Letters
- Vol. 104 (4) , 040602
Direct Measurement of Thermal Fluctuation of High-PendulumWe have achieved a direct measurement of the thermal fluctuation of a pendulum in an off-resonant and wide frequency region using a laser interferometric gravitational-wave detector. These measurements have been well identified for over one decade by an agreement with a theoretical prediction, which is derived by a fluctuation-dissipation theorem. Thermal fluctuation was dominated by the contribution of resistances in coil-magnet actuator circuits. When we tuned these resistances, the noise spectrum also changed according to a theoretical prediction. The measured thermal noise level corresponds to a high quality factor on the order of 105 of the pendulum.
- 28 January 2010
- Published by American Physical Society (APS) in Physical Review Letters
- Vol. 104 (4) , 040602
Open AccessDirect Measurement of Thermal Fluctuation of High-PendulumWe have achieved a direct measurement of the thermal fluctuation of a pendulum in an off-resonant and wide frequency region using a laser interferometric gravitational-wave detector. These measurements have been well identified for over one decade by an agreement with a theoretical prediction, which is derived by a fluctuation-dissipation theorem. Thermal fluctuation was dominated by the contribution of resistances in coil-magnet actuator circuits. When we tuned these resistances, the noise spectrum also changed according to a theoretical prediction. The measured thermal noise level corresponds to a high quality factor on the order of 105 of the pendulum.
- 6 October 2009
- Published by IOP Publishing in Classical and Quantum Gravity
- Vol. 26 (20)
Status of Japanese gravitational wave detectors
- 6 October 2009
- Published by IOP Publishing in Classical and Quantum Gravity
- Vol. 26 (20)
Status of Japanese gravitational wave detectors
- 2 September 2008
- Published by IOP Publishing in Classical and Quantum Gravity
- Vol. 25 (18) , 184013
Search for continuous gravitational waves from PSR J0835-4510 using CLIO data
We search for continuous gravitational waves from PSR J0835-4510 at twice its rotational frequency using CLIO (Cryogenic Laser Interferometric Observatory) in the Kamioka mine. In this search, we use data from an observational run during 12–28 February 2007. We give a brief description of the methods used in this search. We obtain an upper limit on gravitational wave amplitude for PSR J0835-4510 as h0(UL) = 5.3 × 10−20 with 99.4% confidence level.
- 2 September 2008
- Published by IOP Publishing in Classical and Quantum Gravity
- Vol. 25 (18) , 184013
Search for continuous gravitational waves from PSR J0835-4510 using CLIO data
We search for continuous gravitational waves from PSR J0835-4510 at twice its rotational frequency using CLIO (Cryogenic Laser Interferometric Observatory) in the Kamioka mine. In this search, we use data from an observational run during 12–28 February 2007. We give a brief description of the methods used in this search. We obtain an upper limit on gravitational wave amplitude for PSR J0835-4510 as h0(UL) = 5.3 × 10−20 with 99.4% confidence level.