Zhenying Zhang
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Zhenying Zhang has a total of 53 co-authors. Here are the top co-authors by number of shared publications:
Li Chang
5 shared publications- Meiyuan Yang
College of Architecture and Civil Engineering, North China University of Science and Technology, Tangshan 063210, China
5 shared publications - Lili Tian
Department of Foreign Languages, Tangshan College, Tangshan 063000, China
4 shared publications - Lirui Tong
Institute of Architecture and Civil Engineering, North China University of Science and Technology, Tangshan 063009, China
4 shared publications Dingzhu Tian
School of Architecture and Civil Engineering, North China University of Science and Technology, Tangshan, China
3 shared publicationsHongli Wang
3 shared publications
Latest Publications
- Open Access
- 8 September 2025
- Published by MDPI AG in World Electric Vehicle Journal
- Vol. 16 (9) , 505
Assessment of Ejector-Expansion Heat Pump Systems with Low GWP Refrigerants for Electric Vehicles
This study addresses the critical challenge of developing efficient thermal management systems for electric vehicles by proposing and evaluating two novel ejector-expansion heat pump configurations: single-evaporator (SEEHP) and dual-evaporator (DEEHP) systems. Through comprehensive thermodynamic analysis across six representative Chinese cities using four refrigerants (R134a, R32, R152a, R290), system performance via coefficient of performance (COP) and lifecycle CO2 emissions were assessed. The results demonstrate significant advantages over conventional (CBHP) and vapor injection (VIHP) systems, particularly in extreme cold conditions. The SEEHP configuration achieves 10–30% COP improvements versus CBHP, while DEEHP shows 7–15% enhancement. The corresponding lifecycle emission reductions reach 9–14% for SEEHP and 2–11% for DEEHP relative to conventional systems. Among the refrigerants, R290 systems achieve the lowest equivalent CO2 emissions due to superior COP in Beijing, Shanghai, Chongqing, Kunming and Guangzhou, whereas R32 systems yield minimal emissions owing to its exceptional heating capacity in Harbin. These findings highlight ejector technology’s potential for substantially improving electric vehicle energy efficiency while reducing environmental impact.
- 8 September 2025
- Published by MDPI AG in World Electric Vehicle Journal
- Vol. 16 (9) , 505
Open AccessAssessment of Ejector-Expansion Heat Pump Systems with Low GWP Refrigerants for Electric Vehicles
This study addresses the critical challenge of developing efficient thermal management systems for electric vehicles by proposing and evaluating two novel ejector-expansion heat pump configurations: single-evaporator (SEEHP) and dual-evaporator (DEEHP) systems. Through comprehensive thermodynamic analysis across six representative Chinese cities using four refrigerants (R134a, R32, R152a, R290), system performance via coefficient of performance (COP) and lifecycle CO2 emissions were assessed. The results demonstrate significant advantages over conventional (CBHP) and vapor injection (VIHP) systems, particularly in extreme cold conditions. The SEEHP configuration achieves 10–30% COP improvements versus CBHP, while DEEHP shows 7–15% enhancement. The corresponding lifecycle emission reductions reach 9–14% for SEEHP and 2–11% for DEEHP relative to conventional systems. Among the refrigerants, R290 systems achieve the lowest equivalent CO2 emissions due to superior COP in Beijing, Shanghai, Chongqing, Kunming and Guangzhou, whereas R32 systems yield minimal emissions owing to its exceptional heating capacity in Harbin. These findings highlight ejector technology’s potential for substantially improving electric vehicle energy efficiency while reducing environmental impact.
- Open Access
Parametric Effects of Mixing Channel Geometry on Entrainment Characteristics of Ejector in R410A Heat Pump Systems
The two-phase ejector has gained prominence in heat pump systems as a device that effectively mitigates throttling losses through expansion work recovery. This investigation employs three-dimensional computational fluid dynamics (CFD) simulations to analyze the parametric effects of the mixing channel geometry on the entrainment characteristics in an R410A ejector. After validating the model according to the experimental data, the parameter analysis was carried out, and four key geometric parameters were changed within a certain range: the nozzle exit position (NXP = 13–19 mm), the pre-mixing channel convergent angle (CA = 20–60°), the diameter ratio (DDR = 5.0–7.1), and the length-to-diameter ratio (LDR = 8.9–12.4). Multi-variable optimization studies revealed optimal geometric configurations at NXP = 17 mm (about 3.5Dmix), CA = 30°, DR = 6.4, and LDR = 11.1, yielding an optimized mass entrainment ratio enhancement of 23.6% compared to baseline designs. This research provides actionable guidelines for the design of high-efficiency ejector components for heat pump applications.
Open AccessParametric Effects of Mixing Channel Geometry on Entrainment Characteristics of Ejector in R410A Heat Pump Systems
The two-phase ejector has gained prominence in heat pump systems as a device that effectively mitigates throttling losses through expansion work recovery. This investigation employs three-dimensional computational fluid dynamics (CFD) simulations to analyze the parametric effects of the mixing channel geometry on the entrainment characteristics in an R410A ejector. After validating the model according to the experimental data, the parameter analysis was carried out, and four key geometric parameters were changed within a certain range: the nozzle exit position (NXP = 13–19 mm), the pre-mixing channel convergent angle (CA = 20–60°), the diameter ratio (DDR = 5.0–7.1), and the length-to-diameter ratio (LDR = 8.9–12.4). Multi-variable optimization studies revealed optimal geometric configurations at NXP = 17 mm (about 3.5Dmix), CA = 30°, DR = 6.4, and LDR = 11.1, yielding an optimized mass entrainment ratio enhancement of 23.6% compared to baseline designs. This research provides actionable guidelines for the design of high-efficiency ejector components for heat pump applications.
- 4 May 2025
- Published by Elsevier in Applied Thermal Engineering
- Vol. 274
Transient heat and mass transfer characteristics during multiple resurfacing operations in ice rink
- 4 May 2025
- Published by Elsevier in Applied Thermal Engineering
- Vol. 274
Transient heat and mass transfer characteristics during multiple resurfacing operations in ice rink
- 26 April 2024
- Published by Elsevier in Applied Thermal Engineering
- Vol. 248
Effect of the refrigerant charge on transcritical CO2 direct evaporation ice-making system
- 26 April 2024
- Published by Elsevier in Applied Thermal Engineering
- Vol. 248
Effect of the refrigerant charge on transcritical CO2 direct evaporation ice-making system
- 5 February 2024
- Published by Elsevier in Building and Environment
- Vol. 252
Heat and mass transfer during ice resurfacing process in ice rink
- 5 February 2024
- Published by Elsevier in Building and Environment
- Vol. 252
Heat and mass transfer during ice resurfacing process in ice rink
- Open Access
Analysis of Unsteady Heat Transfer during Ice-Making Process for Ice Rink Buildings
The ice-making process is an important factor that affects the ice quality and the energy consumption of ice rinks. An unsteady heat transfer model is established and validated for the ice-making process. The transient temperature variation and ice thickness growing characteristics during the ice-making process are analyzed. The freezing time of a water layer and the final temperature of the stabilized ice layer are quantified. The effects of ice rink structural parameters on the ice-making process are studied. The results show that the water temperature variations during the process go through three stages. The ice-growing process mainly occurs in the second stage. The ice-making process takes about 305 min–420 min for a water layer of 5 mm thickness. The reduction in the ice-making time and the decrease in the final temperature of the stabilized ice layer can be attained by reducing the water layer thickness, the surface heat flux, the cooling pipe spacing, the fluid temperature in the cooling pipe, or the top concrete thickness. Among them, the influences of the thickness of the water layer, the surface heat flux, and the fluid temperature in the cooling pipe are more significant. As the thickness of the water layer decreases from 7 mm to 3 mm, the total ice-making time decreases by about 37.6%. The ice-making time is reduced by 17.1% with the surface heat flux decreasing from 330 W/m2 to 250 W/m2. The ice-making time is reduced by 21.4% with the cooling pipe temperature decreasing from −15.5 °C to −19.5 °C.
Open AccessAnalysis of Unsteady Heat Transfer during Ice-Making Process for Ice Rink Buildings
The ice-making process is an important factor that affects the ice quality and the energy consumption of ice rinks. An unsteady heat transfer model is established and validated for the ice-making process. The transient temperature variation and ice thickness growing characteristics during the ice-making process are analyzed. The freezing time of a water layer and the final temperature of the stabilized ice layer are quantified. The effects of ice rink structural parameters on the ice-making process are studied. The results show that the water temperature variations during the process go through three stages. The ice-growing process mainly occurs in the second stage. The ice-making process takes about 305 min–420 min for a water layer of 5 mm thickness. The reduction in the ice-making time and the decrease in the final temperature of the stabilized ice layer can be attained by reducing the water layer thickness, the surface heat flux, the cooling pipe spacing, the fluid temperature in the cooling pipe, or the top concrete thickness. Among them, the influences of the thickness of the water layer, the surface heat flux, and the fluid temperature in the cooling pipe are more significant. As the thickness of the water layer decreases from 7 mm to 3 mm, the total ice-making time decreases by about 37.6%. The ice-making time is reduced by 17.1% with the surface heat flux decreasing from 330 W/m2 to 250 W/m2. The ice-making time is reduced by 21.4% with the cooling pipe temperature decreasing from −15.5 °C to −19.5 °C.
- Open Access
Parametric Evaluation of Cooling Pipe in Direct Evaporation Artificial Ice Rink
With the coming of the 2022 Beijing Winter Olympic Games, China’s artificial ice rink construction will be in rapid development. A parametric evaluation of the cooling pipe in a direct evaporation rink was performed by numerical simulation. The results showed that the influence of the temperature of the antifreeze pipe on the ice surface temperature can be ignored. The evaporation temperature of the working medium in the cooling pipe is between −32 °C and −22.4 °C to ensure the ice surface temperature is between −5 °C and −3 °C. With the increase in the cooling pipe spacing, the required evaporation temperature of the working medium in the cooling pipe and the uniformity of the ice surface temperature decreased. The required evaporation temperature of the working medium in the cooling pipe decreases by 1.2–1.5 °C for every 10 mm increment of spacing. With the increase in the cooling pipe diameter, the required evaporation temperature of the working medium in the cooling pipe and the uniformity of the ice surface temperature increase. The required evaporation temperature of the working medium in the cooling pipe increases by 2.2–2.9 °C for every 5 mm increment of diameter. The maximum temperature difference of ice surface temperature ranged from 0.004 °C to 0.111 °C.
Open AccessParametric Evaluation of Cooling Pipe in Direct Evaporation Artificial Ice Rink
With the coming of the 2022 Beijing Winter Olympic Games, China’s artificial ice rink construction will be in rapid development. A parametric evaluation of the cooling pipe in a direct evaporation rink was performed by numerical simulation. The results showed that the influence of the temperature of the antifreeze pipe on the ice surface temperature can be ignored. The evaporation temperature of the working medium in the cooling pipe is between −32 °C and −22.4 °C to ensure the ice surface temperature is between −5 °C and −3 °C. With the increase in the cooling pipe spacing, the required evaporation temperature of the working medium in the cooling pipe and the uniformity of the ice surface temperature decreased. The required evaporation temperature of the working medium in the cooling pipe decreases by 1.2–1.5 °C for every 10 mm increment of spacing. With the increase in the cooling pipe diameter, the required evaporation temperature of the working medium in the cooling pipe and the uniformity of the ice surface temperature increase. The required evaporation temperature of the working medium in the cooling pipe increases by 2.2–2.9 °C for every 5 mm increment of diameter. The maximum temperature difference of ice surface temperature ranged from 0.004 °C to 0.111 °C.
- 8 June 2022
- Published by Springer Nature in Journal of Thermal Science
- Vol. 31 (6) , 1914-1927
A Parametric Study on the Effect of Mixing Chamber for Expansion Work Recovery CO2 Ejector
- 8 June 2022
- Published by Springer Nature in Journal of Thermal Science
- Vol. 31 (6) , 1914-1927
A Parametric Study on the Effect of Mixing Chamber for Expansion Work Recovery CO2 Ejector
- Open Access
- 24 April 2022
- Published by MDPI AG in Sustainability
- Vol. 14 (9) , 5117
Environmental and Economic Analysis of Heating Solutions for Rural Residences in China
A spatial assessment is important to explore appropriate heating schemes for rural residences in China. Taking rural residences in six typical cities of China as the focus, four heating solutions, namely, coal-fired boiler heating systems (CBHS), wall-hung gas-fired boiler heating systems (GBHS), direct electric heating systems (DEHS), and air source heat pump systems (ASHPS), are compared and analyzed from the perspectives of primary energy consumption, environmental impact and heating costs. The results show that the primary energy consumption and the environmental impact can be significantly reduced by using solutions of GBHS and ASHPS in comparison with CBHS. DEHS has the most significant primary energy consumption and environmental impact and is less economical. The weighted environmental impact of GBHS is reduced by over 94% compared with that of CBHS, the weighted environmental impact of ASHPS is reduced by 8–23%, 35–39%, and 43–44% compared with that of CBHS for severe cold regions, cold regions, and hot-summer and cold-winter regions, respectively. The life cycle cost of GBHS is about 33% higher than that of CBHS for the six typical cities. The life cycle cost of ASHPS is about 33–57% higher than CBHS for severe cold regions, but not much difference or even less than CBHS for cold regions and hot-summer and cold-winter regions.
- 24 April 2022
- Published by MDPI AG in Sustainability
- Vol. 14 (9) , 5117
Open AccessEnvironmental and Economic Analysis of Heating Solutions for Rural Residences in China
A spatial assessment is important to explore appropriate heating schemes for rural residences in China. Taking rural residences in six typical cities of China as the focus, four heating solutions, namely, coal-fired boiler heating systems (CBHS), wall-hung gas-fired boiler heating systems (GBHS), direct electric heating systems (DEHS), and air source heat pump systems (ASHPS), are compared and analyzed from the perspectives of primary energy consumption, environmental impact and heating costs. The results show that the primary energy consumption and the environmental impact can be significantly reduced by using solutions of GBHS and ASHPS in comparison with CBHS. DEHS has the most significant primary energy consumption and environmental impact and is less economical. The weighted environmental impact of GBHS is reduced by over 94% compared with that of CBHS, the weighted environmental impact of ASHPS is reduced by 8–23%, 35–39%, and 43–44% compared with that of CBHS for severe cold regions, cold regions, and hot-summer and cold-winter regions, respectively. The life cycle cost of GBHS is about 33% higher than that of CBHS for the six typical cities. The life cycle cost of ASHPS is about 33–57% higher than CBHS for severe cold regions, but not much difference or even less than CBHS for cold regions and hot-summer and cold-winter regions.
- 11 January 2022
- Published by Elsevier in Journal of Energy Storage
- Vol. 48, 103979
Mg(NO3)2·6H2O-LiNO3 eutectic/expanded graphite composite phase change material for thermal energy storage applications
- 11 January 2022
- Published by Elsevier in Journal of Energy Storage
- Vol. 48, 103979
Mg(NO3)2·6H2O-LiNO3 eutectic/expanded graphite composite phase change material for thermal energy storage applications