June W. Lau
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
June W. Lau has a total of 232 co-authors. Here are the top co-authors by number of shared publications:
Y. Zhu
Brookhaven National Laboratory 2 Department of Condensed Matter Physics and Materials Science Upton, New York 11973, USA
11 shared publications- Randy K. Dumas
Department of Physics, University of Gothenburg, 412 96 Gothenburg, Sweden
6 shared publications - Yimei Zhu
Brookhaven National Laboratory
6 shared publications - Marco Beleggia
Department of Physics, University of Modena and Reggio Emilia 4 , 41125 Modena
5 shared publications Chunguang Jing
Euclid Techlabs LLC, 365 Remington Blvd. Bolingbrook, IL 60440, USA
4 shared publications- Chunguang Jing
Euclid Beamlabs LLC
4 shared publications
Latest Publications
- Open Access
- 1 May 2025
- Published by AIP Publishing in Structural Dynamics
- Vol. 12 (3) , 034302
Statistically elucidated responses from low-signal contrast mechanisms in ultrafast electron microscopy
The emergence of ultrafast electron microscopy (UEM) has enabled the discovery of strongly correlated dynamic mechanisms, including electron–phonon coupling, structural phase transitions, thermal transport, and electromagnetic deflection. Most UEM systems operate stroboscopically, meaning that the technique is susceptible to artifacts, mistakes, and misinterpretation of the data due to extensive experimental effort. In contrast to the ultrafast designation, data acquisition is extraordinarily slow because the electron beam has significantly reduced signal compared to traditional transmission electron microscopy due to pulsing the electron beam. Consequently, the sample may drift, tilt, or undergo irreversible structural changes that are independent of the time-resolved dynamics throughout the experimental time frame. Furthermore, these datasets require significant user interpretation that can be problematic when proper controls are not implemented thoroughly. Here, we demonstrate a new algorithm designed to separate ultrafast structural dynamics from long-term artifacts using a LiNbO3 sample experiencing electrically driven surface acoustic wave propagation. Additionally, we provide examples of the impact of user bias when analyzing the data and provide a methodology, which enables the extraction of time-resolved responses when the image signal is extraordinarily low. Overall, the goal of this publication is to provide methods that validate the experimental results and reduce researcher biases during UEM data interpretation.
- 1 May 2025
- Published by AIP Publishing in Structural Dynamics
- Vol. 12 (3) , 034302
Open AccessStatistically elucidated responses from low-signal contrast mechanisms in ultrafast electron microscopy
The emergence of ultrafast electron microscopy (UEM) has enabled the discovery of strongly correlated dynamic mechanisms, including electron–phonon coupling, structural phase transitions, thermal transport, and electromagnetic deflection. Most UEM systems operate stroboscopically, meaning that the technique is susceptible to artifacts, mistakes, and misinterpretation of the data due to extensive experimental effort. In contrast to the ultrafast designation, data acquisition is extraordinarily slow because the electron beam has significantly reduced signal compared to traditional transmission electron microscopy due to pulsing the electron beam. Consequently, the sample may drift, tilt, or undergo irreversible structural changes that are independent of the time-resolved dynamics throughout the experimental time frame. Furthermore, these datasets require significant user interpretation that can be problematic when proper controls are not implemented thoroughly. Here, we demonstrate a new algorithm designed to separate ultrafast structural dynamics from long-term artifacts using a LiNbO3 sample experiencing electrically driven surface acoustic wave propagation. Additionally, we provide examples of the impact of user bias when analyzing the data and provide a methodology, which enables the extraction of time-resolved responses when the image signal is extraordinarily low. Overall, the goal of this publication is to provide methods that validate the experimental results and reduce researcher biases during UEM data interpretation.
- Open Access
- 11 November 2024
- Published by Springer Nature in Integrating Materials and Manufacturing Innovation
- Vol. 13 (4) , 915-926
Natural Language Processing-Driven Microscopy Ontology Development
This manuscript describes the accelerated development of an ontology for microscopy in materials science and engineering, leveraging natural language processing (NLP) techniques. Drawing from a comprehensive corpus comprising over 14 k contributions to the Microscopy and Microanalysis conference series, we employed two neural network-based algorithms for NLP. The goal was to semiautomatically create the Microscopy Ontology (MO) that encapsulates and interconnects the terminology most frequently used by the community. The MO, characterized by its interlinked entities and relationships, is designed to enhance the quality of user query results within NexusLIMS. This enhancement is facilitated through the concurrent querying of related terms and the seamless integration of logical connections.
- 11 November 2024
- Published by Springer Nature in Integrating Materials and Manufacturing Innovation
- Vol. 13 (4) , 915-926
Open AccessNatural Language Processing-Driven Microscopy Ontology Development
This manuscript describes the accelerated development of an ontology for microscopy in materials science and engineering, leveraging natural language processing (NLP) techniques. Drawing from a comprehensive corpus comprising over 14 k contributions to the Microscopy and Microanalysis conference series, we employed two neural network-based algorithms for NLP. The goal was to semiautomatically create the Microscopy Ontology (MO) that encapsulates and interconnects the terminology most frequently used by the community. The MO, characterized by its interlinked entities and relationships, is designed to enhance the quality of user query results within NexusLIMS. This enhancement is facilitated through the concurrent querying of related terms and the seamless integration of logical connections.
- Open Access
- 24 July 2024
- Published by Oxford University Press (OUP) in Microscopy and Microanalysis
- Vol. 30 (Supplement)
Practical Considerations for FAIR Data for the APT and FIM Communities: Lessons Learned from the NIST Electron Microscopy Facility
By now we have all seen the steady stream of news about ChatGPT or other AI engines and their fantastic capabilities at reasoning. Yet, scientific research data still feels very far from being able to wow us on that scale. But what does it take to make scientific research data AI-ready? Are we missing big opportunities by regarding our raw instrument outputs as valuable only until the paper is published?
- 24 July 2024
- Published by Oxford University Press (OUP) in Microscopy and Microanalysis
- Vol. 30 (Supplement)
Open AccessPractical Considerations for FAIR Data for the APT and FIM Communities: Lessons Learned from the NIST Electron Microscopy Facility
By now we have all seen the steady stream of news about ChatGPT or other AI engines and their fantastic capabilities at reasoning. Yet, scientific research data still feels very far from being able to wow us on that scale. But what does it take to make scientific research data AI-ready? Are we missing big opportunities by regarding our raw instrument outputs as valuable only until the paper is published?
- 17 February 2022
- Published by Elsevier in Ultramicroscopy
- Vol. 235, 113497
Stroboscopic ultrafast imaging using RF strip-lines in a commercial transmission electron microscope
- 17 February 2022
- Published by Elsevier in Ultramicroscopy
- Vol. 235, 113497
Stroboscopic ultrafast imaging using RF strip-lines in a commercial transmission electron microscope
- Open Access
- 2 October 2020
- Published by American Association for the Advancement of Science (AAAS) in Science Advances
- Vol. 6 (40) , eabc3456
Direct visualization of electromagnetic wave dynamics by laser-free ultrafast electron microscopy
A laser-free hack for ultrafast electron microscopy reveals electromagnetic wave dynamics at picosecond time scale.
- 2 October 2020
- Published by American Association for the Advancement of Science (AAAS) in Science Advances
- Vol. 6 (40) , eabc3456
Open AccessDirect visualization of electromagnetic wave dynamics by laser-free ultrafast electron microscopy
A laser-free hack for ultrafast electron microscopy reveals electromagnetic wave dynamics at picosecond time scale.
- Open Access
Mitigation of radiation damage in biological macromolecules via tunable picosecond pulsed transmission electron microscopy
We report mitigation of electron-beam-induced radiation damage in biological macromolecules using rapid, low-dose transmission electron microscopy (TEM) with a new, tunable, retrofittable picosecond pulser. Damage mitigation strategies historically consisted of sample cryoprotection and ultra-low beam current; ultrafast laser-pulsed systems have shown promise, but with day-long acquisition times. We show the first practical, fast, laser-free tunable system, with acquisition of diffraction series in minutes at 5.2 GHz and 10 pA. This is the largest study to date: two materials (C 36 H 74 paraffin and purple membrane), two beam energies (200 keV and 300 keV), two independent microscopes (Schottky and LaB 6 ), two modes (pulsed and continuous), and unsurpassed repetition rate tunability. Critical dose at room temperature doubled versus continuous beam for ∼100 MHz single-electron repetition rates. Results herald a new class of highly-tunable, ultrafast pulsers with future applications in cryogenic electron microscopy (CryoEM), high resolution single particle imaging, and rapid low-dose TEM.
Open AccessMitigation of radiation damage in biological macromolecules via tunable picosecond pulsed transmission electron microscopy
We report mitigation of electron-beam-induced radiation damage in biological macromolecules using rapid, low-dose transmission electron microscopy (TEM) with a new, tunable, retrofittable picosecond pulser. Damage mitigation strategies historically consisted of sample cryoprotection and ultra-low beam current; ultrafast laser-pulsed systems have shown promise, but with day-long acquisition times. We show the first practical, fast, laser-free tunable system, with acquisition of diffraction series in minutes at 5.2 GHz and 10 pA. This is the largest study to date: two materials (C 36 H 74 paraffin and purple membrane), two beam energies (200 keV and 300 keV), two independent microscopes (Schottky and LaB 6 ), two modes (pulsed and continuous), and unsurpassed repetition rate tunability. Critical dose at room temperature doubled versus continuous beam for ∼100 MHz single-electron repetition rates. Results herald a new class of highly-tunable, ultrafast pulsers with future applications in cryogenic electron microscopy (CryoEM), high resolution single particle imaging, and rapid low-dose TEM.
- Open Access
- 1 February 2020
- Published by AIP Publishing in Review of Scientific Instruments
- Vol. 91 (2) , 021301
Laser-free GHz stroboscopic transmission electron microscope: Components, system integration, and practical considerations for pump–probe measurements
A 300 keV transmission electron microscope was modified to produce broadband pulsed beams that can be, in principle, between 40 MHz and 12 GHz, corresponding to temporal resolution in the nanosecond to picosecond range without an excitation laser. The key enabling technology is a pair of phase-matched modulating and de-modulating traveling wave metallic comb striplines (pulsers). An initial temporal resolution of 30 ps was achieved with a strobe frequency of 6.0 GHz. The placement of the pulsers, mounted immediately below the gun, allows for preservation of all optical configurations, otherwise available to the unmodified instrument, and therefore makes such a post-modified instrument for dual-use, i.e., both pulsed-beam mode (i.e., stroboscopic time-resolved) and conventional continuous waveform mode. In this article, we describe the elements inserted into the beam path, challenges encountered during integration with an in-service microscope, and early results from an electric-field-driven pump–probe experiment. We conclude with ideas for making this class of instruments broadly applicable for examining cyclical and repeatable phenomena.
- 1 February 2020
- Published by AIP Publishing in Review of Scientific Instruments
- Vol. 91 (2) , 021301
Open AccessLaser-free GHz stroboscopic transmission electron microscope: Components, system integration, and practical considerations for pump–probe measurements
A 300 keV transmission electron microscope was modified to produce broadband pulsed beams that can be, in principle, between 40 MHz and 12 GHz, corresponding to temporal resolution in the nanosecond to picosecond range without an excitation laser. The key enabling technology is a pair of phase-matched modulating and de-modulating traveling wave metallic comb striplines (pulsers). An initial temporal resolution of 30 ps was achieved with a strobe frequency of 6.0 GHz. The placement of the pulsers, mounted immediately below the gun, allows for preservation of all optical configurations, otherwise available to the unmodified instrument, and therefore makes such a post-modified instrument for dual-use, i.e., both pulsed-beam mode (i.e., stroboscopic time-resolved) and conventional continuous waveform mode. In this article, we describe the elements inserted into the beam path, challenges encountered during integration with an in-service microscope, and early results from an electric-field-driven pump–probe experiment. We conclude with ideas for making this class of instruments broadly applicable for examining cyclical and repeatable phenomena.
- 17 December 2019
- Published by National Institute of Standards and Technology (NIST) in Journal of Research of the National Institute of Standards and Technology
- Vol. 124, 1-12
Laboratory Information Management Systems for Electron Microscopy: Evaluation of the 4CeeD Data Curation Platform
An evaluation of the feasibility and the requirements associated with a facility-wide deployment of a laboratory information management system (LIMS) at an electron microscopy facility was conducted. 4CeeD, an open-source LIMS, was selected for the focus study. This report summarizes data infrastructure prerequisites, critical and desirable features, and lessons learned from using and interacting with 4CeeD, and broader LIMS adoption recommendations for this facility.
- 17 December 2019
- Published by National Institute of Standards and Technology (NIST) in Journal of Research of the National Institute of Standards and Technology
- Vol. 124, 1-12
Laboratory Information Management Systems for Electron Microscopy: Evaluation of the 4CeeD Data Curation Platform
An evaluation of the feasibility and the requirements associated with a facility-wide deployment of a laboratory information management system (LIMS) at an electron microscopy facility was conducted. 4CeeD, an open-source LIMS, was selected for the focus study. This report summarizes data infrastructure prerequisites, critical and desirable features, and lessons learned from using and interacting with 4CeeD, and broader LIMS adoption recommendations for this facility.
- 1 December 2019
- Published by Elsevier in Ultramicroscopy
- Vol. 207, 112829
Tunable electron beam pulser for picoseconds stroboscopic microscopy in transmission electron microscopes
- 1 December 2019
- Published by Elsevier in Ultramicroscopy
- Vol. 207, 112829
Tunable electron beam pulser for picoseconds stroboscopic microscopy in transmission electron microscopes
- 1 June 2019
- Published by Oxford University Press (OUP) in Microscopy and Microanalysis
- Vol. 25 (S2) , 1658-1659
Laser-Free GHz Stroboscopic TEM: Construction, Deployment, and Benchmarking
- 1 June 2019
- Published by Oxford University Press (OUP) in Microscopy and Microanalysis
- Vol. 25 (S2) , 1658-1659
Laser-Free GHz Stroboscopic TEM: Construction, Deployment, and Benchmarking