Lisa K. Behrens
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Research Interests
Lisa K. Behrens has a total of 73 co-authors. Here are the top co-authors by number of shared publications:
- Andreas Richter
Institute of Environmental Physics, University of Bremen
16 shared publications - John Phillip Burrows
Institute of Environmental Physics, University of Bremen, Bremen, Germany
15 shared publications - Kezia Lange
Institute of Environmental Physics, University of Bremen
10 shared publications - Tim Bösch
Institute of Environmental Physics, University of Bremen, Otto-Hahn-Allee 1, 28359 Bremen, Germany
10 shared publications Bianca Zilker
Institute of Environmental Physics, University of Bremen
7 shared publicationsHyunkee Hong
National Institute of Environmental Research
7 shared publications
Latest Publications
- Open Access
- 10 December 2025
- Published by Taylor & Francis in GIScience & Remote Sensing
- Vol. 62 (1)
Comparison of GEMS v3.0 tropospheric NO 2 columns with ground-based DOAS instruments in Ulsan
- 10 December 2025
- Published by Taylor & Francis in GIScience & Remote Sensing
- Vol. 62 (1)
Open AccessComparison of GEMS v3.0 tropospheric NO 2 columns with ground-based DOAS instruments in Ulsan
- Open Access
- 20 January 2025
- Published by Copernicus GmbH
MAX-DOAS measurements of air pollution on the northern tip of Taiwan
Wind and weather in Taiwan are strongly influenced by the monsoons. Taiwan is on the lee side of the Asian winter monsoon, originating on the Asian continent. It receives continental air masses transported by the monsoon, thus air pollutants originating in the eastern and northern parts of China. While polluted air reaches Taiwan during winter monsoon, clean air masses from the remote western North Pacific are predominant in summer, making Taiwan an ideal location to investigate variations in atmospheric composition due to the monsoons. In addition to that, the monsoons themselves are also subject to regional climate changes in the future. Since June 2023, a Multi-AXis-DOAS (MAX-DOAS) instrument has been installed at the Cape Fuguei Research Station (CAFE) at the northernmost point of Taiwan, measuring vertical and horizontal distributions of trace gases, including NO2, SO2, HCHO, and aerosols. The measurements aim to investigate local air pollution and study the impact of pollution export from mainland China on tropospheric composition and local air quality. The MAX-DOAS and the other measurements at the site will also be very valuable in the validation of the data products from the GEMS satellite.The measurements are part of the project “Investigation of Pollution Transport to Taiwan” (IPToT), which has been established as a cooperation between the Insitute of Environmental Physics (IUP) of the University of Bremen (Germany) and the Research Center for Environmental Changes of the Academia Sinica (Taiwan), funded by the DFG (Deutsche Forschungsgemeinschaft). Here, we present first MAX-DOAS observations and retrieved profiles of NO2, SO2, HCHO, and aerosols at this new station and compare them to collocated in-situ and (aerosol) LIDAR measurements. The data are evaluated for diurnal and weekly pollution signals and the dependency on the prevailing wind direction. A first comparison to satellite measurements is also shown.
- 20 January 2025
- Published by Copernicus GmbH
Open AccessMAX-DOAS measurements of air pollution on the northern tip of Taiwan
Wind and weather in Taiwan are strongly influenced by the monsoons. Taiwan is on the lee side of the Asian winter monsoon, originating on the Asian continent. It receives continental air masses transported by the monsoon, thus air pollutants originating in the eastern and northern parts of China. While polluted air reaches Taiwan during winter monsoon, clean air masses from the remote western North Pacific are predominant in summer, making Taiwan an ideal location to investigate variations in atmospheric composition due to the monsoons. In addition to that, the monsoons themselves are also subject to regional climate changes in the future. Since June 2023, a Multi-AXis-DOAS (MAX-DOAS) instrument has been installed at the Cape Fuguei Research Station (CAFE) at the northernmost point of Taiwan, measuring vertical and horizontal distributions of trace gases, including NO2, SO2, HCHO, and aerosols. The measurements aim to investigate local air pollution and study the impact of pollution export from mainland China on tropospheric composition and local air quality. The MAX-DOAS and the other measurements at the site will also be very valuable in the validation of the data products from the GEMS satellite.The measurements are part of the project “Investigation of Pollution Transport to Taiwan” (IPToT), which has been established as a cooperation between the Insitute of Environmental Physics (IUP) of the University of Bremen (Germany) and the Research Center for Environmental Changes of the Academia Sinica (Taiwan), funded by the DFG (Deutsche Forschungsgemeinschaft). Here, we present first MAX-DOAS observations and retrieved profiles of NO2, SO2, HCHO, and aerosols at this new station and compare them to collocated in-situ and (aerosol) LIDAR measurements. The data are evaluated for diurnal and weekly pollution signals and the dependency on the prevailing wind direction. A first comparison to satellite measurements is also shown.
- Open Access
- 30 October 2024
- Published by Copernicus GmbH in Atmospheric Measurement Techniques
- Vol. 17 (21) , 6315-6344
Validation of GEMS tropospheric NO2 columns and their diurnal variation with ground-based DOAS measurements
Instruments for air quality observations on geostationary satellites provide multiple observations per day and allow for the analysis of the diurnal variation in important air pollutants such as nitrogen dioxide (NO2). The South Korean instrument GEMS (Geostationary Environmental Monitoring Spectrometer), launched in February 2020, is the first geostationary instrument that is able to observe the diurnal variation in NO2. The measurements have a spatial resolution of 3.5 km × 8 km and cover a large part of Asia. This study compares 1 year of tropospheric NO2 vertical column density (VCD) observations from the operational GEMS L2 product, the scientific GEMS IUP-UB (Institute of Environmental Physics at the University of Bremen) product, the operational TROPOspheric Monitoring Instrument (TROPOMI) product, and ground-based differential optical absorption spectroscopy (DOAS) measurements in South Korea. The GEMS L2 tropospheric NO2 VCDs overestimate the ground-based tropospheric NO2 VCDs with a median relative difference of +61 % and a correlation coefficient of 0.76. The median relative difference is −2 % for the GEMS IUP-UB product and −16 % for the TROPOMI product, with correlation coefficients of 0.83 and 0.89, respectively. The scatter in the GEMS products can be reduced when observations are limited to the TROPOMI overpass time. Diurnal variations in tropospheric NO2 VCDs differ by the pollution level of the analyzed site but with good agreement between the GEMS IUP-UB and ground-based observations. Low-pollution sites show weak or almost no diurnal variation. In summer, the polluted sites show a minimum around noon, indicating the large influence of photochemical loss. Most variation is seen in spring and autumn, with increasing NO2 in the morning, a maximum close to noon, and a decrease towards the afternoon. Winter observations show rather flat or slightly decreasing NO2 throughout the day. Winter observations under low-wind-speed conditions at high-pollution sites show enhancements of NO2 throughout the day. This indicates that under calm conditions, dilution and the less effective chemical loss in winter do not balance the accumulating emissions. Diurnal variation observed at a low-pollution site follows seasonal wind patterns. A weekday–weekend effect analysis shows good agreement between the different products. However, the GEMS L2 product, while agreeing with the other data sets on weekdays, shows significantly less reduction on weekends. The influence of the stratospheric contribution and the surface reflectivity product on the satellite tropospheric NO2 VCD products is investigated. While the TM5 model's stratospheric VCDs, used in the TROPOMI product, are too high, resulting in tropospheric NO2 VCDs that are too low and even negative, when used in the GEMS IUP-UB retrieval, the GEMS L2 stratospheric VCD is too low. Surface reflectivity comparisons indicate that the GEMS L2 reflectivity makes a large contribution to the observed overestimation and scatter.
- 30 October 2024
- Published by Copernicus GmbH in Atmospheric Measurement Techniques
- Vol. 17 (21) , 6315-6344
Open AccessValidation of GEMS tropospheric NO2 columns and their diurnal variation with ground-based DOAS measurements
Instruments for air quality observations on geostationary satellites provide multiple observations per day and allow for the analysis of the diurnal variation in important air pollutants such as nitrogen dioxide (NO2). The South Korean instrument GEMS (Geostationary Environmental Monitoring Spectrometer), launched in February 2020, is the first geostationary instrument that is able to observe the diurnal variation in NO2. The measurements have a spatial resolution of 3.5 km × 8 km and cover a large part of Asia. This study compares 1 year of tropospheric NO2 vertical column density (VCD) observations from the operational GEMS L2 product, the scientific GEMS IUP-UB (Institute of Environmental Physics at the University of Bremen) product, the operational TROPOspheric Monitoring Instrument (TROPOMI) product, and ground-based differential optical absorption spectroscopy (DOAS) measurements in South Korea. The GEMS L2 tropospheric NO2 VCDs overestimate the ground-based tropospheric NO2 VCDs with a median relative difference of +61 % and a correlation coefficient of 0.76. The median relative difference is −2 % for the GEMS IUP-UB product and −16 % for the TROPOMI product, with correlation coefficients of 0.83 and 0.89, respectively. The scatter in the GEMS products can be reduced when observations are limited to the TROPOMI overpass time. Diurnal variations in tropospheric NO2 VCDs differ by the pollution level of the analyzed site but with good agreement between the GEMS IUP-UB and ground-based observations. Low-pollution sites show weak or almost no diurnal variation. In summer, the polluted sites show a minimum around noon, indicating the large influence of photochemical loss. Most variation is seen in spring and autumn, with increasing NO2 in the morning, a maximum close to noon, and a decrease towards the afternoon. Winter observations show rather flat or slightly decreasing NO2 throughout the day. Winter observations under low-wind-speed conditions at high-pollution sites show enhancements of NO2 throughout the day. This indicates that under calm conditions, dilution and the less effective chemical loss in winter do not balance the accumulating emissions. Diurnal variation observed at a low-pollution site follows seasonal wind patterns. A weekday–weekend effect analysis shows good agreement between the different products. However, the GEMS L2 product, while agreeing with the other data sets on weekdays, shows significantly less reduction on weekends. The influence of the stratospheric contribution and the surface reflectivity product on the satellite tropospheric NO2 VCD products is investigated. While the TM5 model's stratospheric VCDs, used in the TROPOMI product, are too high, resulting in tropospheric NO2 VCDs that are too low and even negative, when used in the GEMS IUP-UB retrieval, the GEMS L2 stratospheric VCD is too low. Surface reflectivity comparisons indicate that the GEMS L2 reflectivity makes a large contribution to the observed overestimation and scatter.
- Open Access
- 24 April 2024
- Published by Copernicus GmbH
- Vol. 2024, 1-42
Comment on egusphere-2024-617
Instruments for air quality observations on geostationary satellites provide multiple observations per day and allow for the analysis of the diurnal variation of important air pollutants such as nitrogen dioxide (NO2) over large areas. The South Korean instrument GEMS on the GK2B satellite was launched in February 2020 and is the first instrument in geostationary orbit that delivers hourly daytime observations of NO2. The measurements with a spatial resolution of 3.5 km x 8 km cover a large part of Asia. This study compares one year of tropospheric NO2 vertical column density (VCD) observations of the operational GEMS L2 product, the scientific GEMS IUP-UB product, the operational TROPOMI product, and ground-based DOAS measurements in South Korea. The GEMS L2 tropospheric NO2 VCDs overestimate the VCDs retrieved from the ground-based observations with a median relative difference of +64 % and a correlation coefficient of 0.75. The median relative difference is -1 % for the GEMS IUP-UB product and -14 % for the TROPOMI product. The evaluation of the GEMS IUP-UB product and the operational TROPOMI product with ground-based measurements is in good agreement with correlation coefficients of 0.82 and 0.88. The scatter in the GEMS products can be reduced when observations are limited to the TROPOMI overpass time. The observed diurnal variations of the tropospheric NO2 VCDs show a maximum of NO2 during the late morning for urban sites, whereas rural sites show weak or almost no diurnal changes. Investigations of the seasonal diurnal variability show with a minimum in the observed tropospheric NO2 VCDs around noon the importance of chemical loss of NO2 in summer. Most variability is seen in spring and autumn, which dominate the average annual diurnal cycle. Observations under low wind conditions show strong enhancements of NO2 over the day, especially at polluted sites during winter. This indicates that under calm conditions, dilution and the less effective chemical loss in winter do not balance the accumulating emissions. The impact of transport processes is illustrated by the diurnal variability at a rural site following mean wind patterns for specific seasons and observation times. Analyzing the weekday-weekend effect, good agreement was found between the different products. However, the GEMS L2 product while agreeing with the other data sets during weekdays shows significantly less reduction on weekends. Our investigations show that the observed diurnal evolution of NO2 varies significantly at the different measurement sites, with good agreement between the GEMS IUP-UB and ground-based observations. The diurnal variability of tropospheric NO2 VCDs depends on chemistry, emissions, and transport into and out of the measurement region. To interpret the sources and sinks of NO2 requires that all of these factors are considered.
- 24 April 2024
- Published by Copernicus GmbH
- Vol. 2024, 1-42
Open AccessComment on egusphere-2024-617
Instruments for air quality observations on geostationary satellites provide multiple observations per day and allow for the analysis of the diurnal variation of important air pollutants such as nitrogen dioxide (NO2) over large areas. The South Korean instrument GEMS on the GK2B satellite was launched in February 2020 and is the first instrument in geostationary orbit that delivers hourly daytime observations of NO2. The measurements with a spatial resolution of 3.5 km x 8 km cover a large part of Asia. This study compares one year of tropospheric NO2 vertical column density (VCD) observations of the operational GEMS L2 product, the scientific GEMS IUP-UB product, the operational TROPOMI product, and ground-based DOAS measurements in South Korea. The GEMS L2 tropospheric NO2 VCDs overestimate the VCDs retrieved from the ground-based observations with a median relative difference of +64 % and a correlation coefficient of 0.75. The median relative difference is -1 % for the GEMS IUP-UB product and -14 % for the TROPOMI product. The evaluation of the GEMS IUP-UB product and the operational TROPOMI product with ground-based measurements is in good agreement with correlation coefficients of 0.82 and 0.88. The scatter in the GEMS products can be reduced when observations are limited to the TROPOMI overpass time. The observed diurnal variations of the tropospheric NO2 VCDs show a maximum of NO2 during the late morning for urban sites, whereas rural sites show weak or almost no diurnal changes. Investigations of the seasonal diurnal variability show with a minimum in the observed tropospheric NO2 VCDs around noon the importance of chemical loss of NO2 in summer. Most variability is seen in spring and autumn, which dominate the average annual diurnal cycle. Observations under low wind conditions show strong enhancements of NO2 over the day, especially at polluted sites during winter. This indicates that under calm conditions, dilution and the less effective chemical loss in winter do not balance the accumulating emissions. The impact of transport processes is illustrated by the diurnal variability at a rural site following mean wind patterns for specific seasons and observation times. Analyzing the weekday-weekend effect, good agreement was found between the different products. However, the GEMS L2 product while agreeing with the other data sets during weekdays shows significantly less reduction on weekends. Our investigations show that the observed diurnal evolution of NO2 varies significantly at the different measurement sites, with good agreement between the GEMS IUP-UB and ground-based observations. The diurnal variability of tropospheric NO2 VCDs depends on chemistry, emissions, and transport into and out of the measurement region. To interpret the sources and sinks of NO2 requires that all of these factors are considered.
- Open Access
- 19 April 2024
- Published by Copernicus GmbH
- Vol. 2024, 1-42
Comment on egusphere-2024-617
Instruments for air quality observations on geostationary satellites provide multiple observations per day and allow for the analysis of the diurnal variation of important air pollutants such as nitrogen dioxide (NO2) over large areas. The South Korean instrument GEMS on the GK2B satellite was launched in February 2020 and is the first instrument in geostationary orbit that delivers hourly daytime observations of NO2. The measurements with a spatial resolution of 3.5 km x 8 km cover a large part of Asia. This study compares one year of tropospheric NO2 vertical column density (VCD) observations of the operational GEMS L2 product, the scientific GEMS IUP-UB product, the operational TROPOMI product, and ground-based DOAS measurements in South Korea. The GEMS L2 tropospheric NO2 VCDs overestimate the VCDs retrieved from the ground-based observations with a median relative difference of +64 % and a correlation coefficient of 0.75. The median relative difference is -1 % for the GEMS IUP-UB product and -14 % for the TROPOMI product. The evaluation of the GEMS IUP-UB product and the operational TROPOMI product with ground-based measurements is in good agreement with correlation coefficients of 0.82 and 0.88. The scatter in the GEMS products can be reduced when observations are limited to the TROPOMI overpass time. The observed diurnal variations of the tropospheric NO2 VCDs show a maximum of NO2 during the late morning for urban sites, whereas rural sites show weak or almost no diurnal changes. Investigations of the seasonal diurnal variability show with a minimum in the observed tropospheric NO2 VCDs around noon the importance of chemical loss of NO2 in summer. Most variability is seen in spring and autumn, which dominate the average annual diurnal cycle. Observations under low wind conditions show strong enhancements of NO2 over the day, especially at polluted sites during winter. This indicates that under calm conditions, dilution and the less effective chemical loss in winter do not balance the accumulating emissions. The impact of transport processes is illustrated by the diurnal variability at a rural site following mean wind patterns for specific seasons and observation times. Analyzing the weekday-weekend effect, good agreement was found between the different products. However, the GEMS L2 product while agreeing with the other data sets during weekdays shows significantly less reduction on weekends. Our investigations show that the observed diurnal evolution of NO2 varies significantly at the different measurement sites, with good agreement between the GEMS IUP-UB and ground-based observations. The diurnal variability of tropospheric NO2 VCDs depends on chemistry, emissions, and transport into and out of the measurement region. To interpret the sources and sinks of NO2 requires that all of these factors are considered.
- 19 April 2024
- Published by Copernicus GmbH
- Vol. 2024, 1-42
Open AccessComment on egusphere-2024-617
Instruments for air quality observations on geostationary satellites provide multiple observations per day and allow for the analysis of the diurnal variation of important air pollutants such as nitrogen dioxide (NO2) over large areas. The South Korean instrument GEMS on the GK2B satellite was launched in February 2020 and is the first instrument in geostationary orbit that delivers hourly daytime observations of NO2. The measurements with a spatial resolution of 3.5 km x 8 km cover a large part of Asia. This study compares one year of tropospheric NO2 vertical column density (VCD) observations of the operational GEMS L2 product, the scientific GEMS IUP-UB product, the operational TROPOMI product, and ground-based DOAS measurements in South Korea. The GEMS L2 tropospheric NO2 VCDs overestimate the VCDs retrieved from the ground-based observations with a median relative difference of +64 % and a correlation coefficient of 0.75. The median relative difference is -1 % for the GEMS IUP-UB product and -14 % for the TROPOMI product. The evaluation of the GEMS IUP-UB product and the operational TROPOMI product with ground-based measurements is in good agreement with correlation coefficients of 0.82 and 0.88. The scatter in the GEMS products can be reduced when observations are limited to the TROPOMI overpass time. The observed diurnal variations of the tropospheric NO2 VCDs show a maximum of NO2 during the late morning for urban sites, whereas rural sites show weak or almost no diurnal changes. Investigations of the seasonal diurnal variability show with a minimum in the observed tropospheric NO2 VCDs around noon the importance of chemical loss of NO2 in summer. Most variability is seen in spring and autumn, which dominate the average annual diurnal cycle. Observations under low wind conditions show strong enhancements of NO2 over the day, especially at polluted sites during winter. This indicates that under calm conditions, dilution and the less effective chemical loss in winter do not balance the accumulating emissions. The impact of transport processes is illustrated by the diurnal variability at a rural site following mean wind patterns for specific seasons and observation times. Analyzing the weekday-weekend effect, good agreement was found between the different products. However, the GEMS L2 product while agreeing with the other data sets during weekdays shows significantly less reduction on weekends. Our investigations show that the observed diurnal evolution of NO2 varies significantly at the different measurement sites, with good agreement between the GEMS IUP-UB and ground-based observations. The diurnal variability of tropospheric NO2 VCDs depends on chemistry, emissions, and transport into and out of the measurement region. To interpret the sources and sinks of NO2 requires that all of these factors are considered.
- Open Access
- 28 March 2024
- Published by Copernicus GmbH in EGUsphere
- Vol. 2024, 1-42
Validation of GEMS tropospheric NO2 columns and their diurnal variation with ground-based DOAS measurements
Instruments for air quality observations on geostationary satellites provide multiple observations per day and allow for the analysis of the diurnal variation of important air pollutants such as nitrogen dioxide (NO2) over large areas. The South Korean instrument GEMS on the GK2B satellite was launched in February 2020 and is the first instrument in geostationary orbit that delivers hourly daytime observations of NO2. The measurements with a spatial resolution of 3.5 km x 8 km cover a large part of Asia. This study compares one year of tropospheric NO2 vertical column density (VCD) observations of the operational GEMS L2 product, the scientific GEMS IUP-UB product, the operational TROPOMI product, and ground-based DOAS measurements in South Korea. The GEMS L2 tropospheric NO2 VCDs overestimate the VCDs retrieved from the ground-based observations with a median relative difference of +64 % and a correlation coefficient of 0.75. The median relative difference is -1 % for the GEMS IUP-UB product and -14 % for the TROPOMI product. The evaluation of the GEMS IUP-UB product and the operational TROPOMI product with ground-based measurements is in good agreement with correlation coefficients of 0.82 and 0.88. The scatter in the GEMS products can be reduced when observations are limited to the TROPOMI overpass time. The observed diurnal variations of the tropospheric NO2 VCDs show a maximum of NO2 during the late morning for urban sites, whereas rural sites show weak or almost no diurnal changes. Investigations of the seasonal diurnal variability show with a minimum in the observed tropospheric NO2 VCDs around noon the importance of chemical loss of NO2 in summer. Most variability is seen in spring and autumn, which dominate the average annual diurnal cycle. Observations under low wind conditions show strong enhancements of NO2 over the day, especially at polluted sites during winter. This indicates that under calm conditions, dilution and the less effective chemical loss in winter do not balance the accumulating emissions. The impact of transport processes is illustrated by the diurnal variability at a rural site following mean wind patterns for specific seasons and observation times. Analyzing the weekday-weekend effect, good agreement was found between the different products. However, the GEMS L2 product while agreeing with the other data sets during weekdays shows significantly less reduction on weekends. Our investigations show that the observed diurnal evolution of NO2 varies significantly at the different measurement sites, with good agreement between the GEMS IUP-UB and ground-based observations. The diurnal variability of tropospheric NO2 VCDs depends on chemistry, emissions, and transport into and out of the measurement region. To interpret the sources and sinks of NO2 requires that all of these factors are considered.
- 28 March 2024
- Published by Copernicus GmbH in EGUsphere
- Vol. 2024, 1-42
Open AccessValidation of GEMS tropospheric NO2 columns and their diurnal variation with ground-based DOAS measurements
Instruments for air quality observations on geostationary satellites provide multiple observations per day and allow for the analysis of the diurnal variation of important air pollutants such as nitrogen dioxide (NO2) over large areas. The South Korean instrument GEMS on the GK2B satellite was launched in February 2020 and is the first instrument in geostationary orbit that delivers hourly daytime observations of NO2. The measurements with a spatial resolution of 3.5 km x 8 km cover a large part of Asia. This study compares one year of tropospheric NO2 vertical column density (VCD) observations of the operational GEMS L2 product, the scientific GEMS IUP-UB product, the operational TROPOMI product, and ground-based DOAS measurements in South Korea. The GEMS L2 tropospheric NO2 VCDs overestimate the VCDs retrieved from the ground-based observations with a median relative difference of +64 % and a correlation coefficient of 0.75. The median relative difference is -1 % for the GEMS IUP-UB product and -14 % for the TROPOMI product. The evaluation of the GEMS IUP-UB product and the operational TROPOMI product with ground-based measurements is in good agreement with correlation coefficients of 0.82 and 0.88. The scatter in the GEMS products can be reduced when observations are limited to the TROPOMI overpass time. The observed diurnal variations of the tropospheric NO2 VCDs show a maximum of NO2 during the late morning for urban sites, whereas rural sites show weak or almost no diurnal changes. Investigations of the seasonal diurnal variability show with a minimum in the observed tropospheric NO2 VCDs around noon the importance of chemical loss of NO2 in summer. Most variability is seen in spring and autumn, which dominate the average annual diurnal cycle. Observations under low wind conditions show strong enhancements of NO2 over the day, especially at polluted sites during winter. This indicates that under calm conditions, dilution and the less effective chemical loss in winter do not balance the accumulating emissions. The impact of transport processes is illustrated by the diurnal variability at a rural site following mean wind patterns for specific seasons and observation times. Analyzing the weekday-weekend effect, good agreement was found between the different products. However, the GEMS L2 product while agreeing with the other data sets during weekdays shows significantly less reduction on weekends. Our investigations show that the observed diurnal evolution of NO2 varies significantly at the different measurement sites, with good agreement between the GEMS IUP-UB and ground-based observations. The diurnal variability of tropospheric NO2 VCDs depends on chemistry, emissions, and transport into and out of the measurement region. To interpret the sources and sinks of NO2 requires that all of these factors are considered.
- Open Access
- 15 May 2023
- Published by Copernicus GmbH
First measurements of spatial NO2 variability in Bremen with a newly developed tram DOAS instrument
Mobile DOAS measurements are a good option to determine the spatial distribution of NO2 or other trace gases such as HCHO and SO2 within a city. In previous works, such measurements have been performed using cars and have provided interesting insights into spatial inhomogeneities of the NO2 distribution and valuable contributions to satellite validation. A disadvantage of car DOAS measurements is the time required for driving the car.Therefore, a new DOAS instrument was developed and installed on a tram in Bremen in November 2021. The instrument is mostly operating in zenith-sky mode, but also takes measurements at 20° elevation every 7 minutes. The advantage of the tram DOAS instrument is that it performs measurements during the normal operation of the tram. As a result, regular measurements along the route network can be carried out without additional time spent driving.Up to now, the instrument has gathered one year of data all over the Bremen tram network. It can be clearly seen that the areas of increased tropospheric NO2 VCDs change throughout the day, but certain areas show reproducibly higher NO2 pollution. We found elevated NO2 levels in the industrially dominated northwest and lower levels in the more rural northeast of Bremen. This is confirmation for a very similar distribution visible in the TROPOMI tropospheric NO2 VCDs data. In addition, the tram DOAS measurements are compared to the measurements from a stationary MAX-DOAS instrument installed close to one of the tram lines.
- 15 May 2023
- Published by Copernicus GmbH
Open AccessFirst measurements of spatial NO2 variability in Bremen with a newly developed tram DOAS instrument
Mobile DOAS measurements are a good option to determine the spatial distribution of NO2 or other trace gases such as HCHO and SO2 within a city. In previous works, such measurements have been performed using cars and have provided interesting insights into spatial inhomogeneities of the NO2 distribution and valuable contributions to satellite validation. A disadvantage of car DOAS measurements is the time required for driving the car.Therefore, a new DOAS instrument was developed and installed on a tram in Bremen in November 2021. The instrument is mostly operating in zenith-sky mode, but also takes measurements at 20° elevation every 7 minutes. The advantage of the tram DOAS instrument is that it performs measurements during the normal operation of the tram. As a result, regular measurements along the route network can be carried out without additional time spent driving.Up to now, the instrument has gathered one year of data all over the Bremen tram network. It can be clearly seen that the areas of increased tropospheric NO2 VCDs change throughout the day, but certain areas show reproducibly higher NO2 pollution. We found elevated NO2 levels in the industrially dominated northwest and lower levels in the more rural northeast of Bremen. This is confirmation for a very similar distribution visible in the TROPOMI tropospheric NO2 VCDs data. In addition, the tram DOAS measurements are compared to the measurements from a stationary MAX-DOAS instrument installed close to one of the tram lines.
- Open Access
- 15 May 2023
- Published by Copernicus GmbH
An improved tropospheric NO2 product for the GEMS instrument
Nitrogen oxides are among the most important pollutants in the troposphere. They are emitted in many anthropogenic activities such as fossil fuel use for energy production and transportation or agricultural burning. At high concentrations, nitrogen oxides are a health hazard. They also are involved in the formation of tropospheric ozone and acid rain.There are many different ways to measure nitrogen oxides in the atmosphere. Satellite observations of NO2 are one of the most powerful as they provide excellent coverage. However, the spatial resolution is limited and in the case of measurements from low-earth satellites, there is only one measurement per day. The latter problem can be overcome by using geostationary satellites, and the Korean GEMS instrument is the first to provide hourly NO2 observations over Asia.In this study, a full year of tropospheric NO2 columns are retrieved from GEMS observations. Different retrieval settings are applied and the results compared with a particular emphasis on the analysis of the diurnal variation of NO2. Sensitivity tests include correction for the polarisation sensitivity of the GEMS instrument, different stratospheric correction schemes, different surface reflectances and different a priori profiles. While all of these parameters affect the retrieved NO2 columns, the pattern of the diurnal variation of the retrieved tropospheric columns appears to be robust, at least over regions with large pollution signals.
- 15 May 2023
- Published by Copernicus GmbH
Open AccessAn improved tropospheric NO2 product for the GEMS instrument
Nitrogen oxides are among the most important pollutants in the troposphere. They are emitted in many anthropogenic activities such as fossil fuel use for energy production and transportation or agricultural burning. At high concentrations, nitrogen oxides are a health hazard. They also are involved in the formation of tropospheric ozone and acid rain.There are many different ways to measure nitrogen oxides in the atmosphere. Satellite observations of NO2 are one of the most powerful as they provide excellent coverage. However, the spatial resolution is limited and in the case of measurements from low-earth satellites, there is only one measurement per day. The latter problem can be overcome by using geostationary satellites, and the Korean GEMS instrument is the first to provide hourly NO2 observations over Asia.In this study, a full year of tropospheric NO2 columns are retrieved from GEMS observations. Different retrieval settings are applied and the results compared with a particular emphasis on the analysis of the diurnal variation of NO2. Sensitivity tests include correction for the polarisation sensitivity of the GEMS instrument, different stratospheric correction schemes, different surface reflectances and different a priori profiles. While all of these parameters affect the retrieved NO2 columns, the pattern of the diurnal variation of the retrieved tropospheric columns appears to be robust, at least over regions with large pollution signals.
- Top Cited PapersOpen Access
- 14 March 2023
- Published by Copernicus GmbH in Atmospheric Measurement Techniques
- Vol. 16 (5) , 1357-1389
Validation of Sentinel-5P TROPOMI tropospheric NO2 products by comparison with NO2 measurements from airborne imaging DOAS, ground-based stationary DOAS, and mobile car DOAS measurements during the S5P-VAL-DE-Ruhr campaign
Airborne imaging differential optical absorption spectroscopy (DOAS), ground-based stationary DOAS, and car DOAS measurements were conducted during the S5P-VAL-DE-Ruhr campaign in September 2020. The campaign area is located in the Rhine-Ruhr region of North Rhine-Westphalia, western Germany, which is a pollution hotspot in Europe comprising urban and large industrial sources. The DOAS measurements are used to validate spaceborne NO2 tropospheric vertical column density (VCD) data products from the Sentinel-5 Precursor (S5P) TROPOspheric Monitoring Instrument (TROPOMI). Seven flights were performed with the airborne imaging DOAS instrument for measurements of atmospheric pollution (AirMAP), providing measurements that were used to create continuous maps of NO2 in the layer below the aircraft. These flights cover many S5P ground pixels within an area of 30 km × 35 km and were accompanied by ground-based stationary measurements and three mobile car DOAS instruments. Stationary measurements were conducted by two Pandora, two Zenith-DOAS, and two MAX-DOAS instruments. Ground-based stationary and car DOAS measurements are used to evaluate the AirMAP tropospheric NO2 VCDs and show high Pearson correlation coefficients of 0.88 and 0.89 and slopes of 0.90 ± 0.09 and 0.89 ± 0.02 for the stationary and car DOAS, respectively. Having a spatial resolution of about 100 m × 30 m, the AirMAP tropospheric NO2 VCD data create a link between the ground-based and the TROPOMI measurements with a nadir resolution of 3.5 km × 5.5 km and are therefore well suited to validate the TROPOMI tropospheric NO2 VCD. The observations on the 7 flight days show strong NO2 variability, which is dependent on the three target areas, the day of the week, and the meteorological conditions. The AirMAP campaign data set is compared to the TROPOMI NO2 operational offline (OFFL) V01.03.02 data product, the reprocessed NO2 data using the V02.03.01 of the official level-2 processor provided by the Product Algorithm Laboratory (PAL), and several scientific TROPOMI NO2 data products. The AirMAP and TROPOMI OFFL V01.03.02 data are highly correlated (r=0.87) but show an underestimation of the TROPOMI data with a slope of 0.38 ± 0.02 and a median relative difference of −9 %. With the modifications in the NO2 retrieval implemented in the PAL V02.03.01 product, the slope and median relative difference increased to 0.83 ± 0.06 and +20 %. However, the modifications resulted in larger scatter and the correlation decreased significantly to r=0.72. The results can be improved by not applying a cloud correction for the TROPOMI data in conditions with high aerosol load and when cloud pressures are retrieved close to the surface. The influence of spatially more highly resolved a priori NO2 vertical profiles and surface reflectivity are investigated using scientific TROPOMI tropospheric NO2 VCD data products. The comparison of the AirMAP campaign data set to the scientific data products shows that the choice of surface reflectivity database has a minor impact on the tropospheric NO2 VCD retrieval in the campaign region and season. In comparison, the replacement of the a priori NO2 profile in combination with the improvements in the retrieval of the PAL V02.03.01 product regarding cloud heights can further increase the tropospheric NO2 VCDs. This study demonstrates that the underestimation of the TROPOMI tropospheric NO2 VCD product with respect to the validation data set has been and can be further significantly improved.
- 14 March 2023
- Published by Copernicus GmbH in Atmospheric Measurement Techniques
- Vol. 16 (5) , 1357-1389
Top Cited PapersOpen AccessValidation of Sentinel-5P TROPOMI tropospheric NO2 products by comparison with NO2 measurements from airborne imaging DOAS, ground-based stationary DOAS, and mobile car DOAS measurements during the S5P-VAL-DE-Ruhr campaign
Airborne imaging differential optical absorption spectroscopy (DOAS), ground-based stationary DOAS, and car DOAS measurements were conducted during the S5P-VAL-DE-Ruhr campaign in September 2020. The campaign area is located in the Rhine-Ruhr region of North Rhine-Westphalia, western Germany, which is a pollution hotspot in Europe comprising urban and large industrial sources. The DOAS measurements are used to validate spaceborne NO2 tropospheric vertical column density (VCD) data products from the Sentinel-5 Precursor (S5P) TROPOspheric Monitoring Instrument (TROPOMI). Seven flights were performed with the airborne imaging DOAS instrument for measurements of atmospheric pollution (AirMAP), providing measurements that were used to create continuous maps of NO2 in the layer below the aircraft. These flights cover many S5P ground pixels within an area of 30 km × 35 km and were accompanied by ground-based stationary measurements and three mobile car DOAS instruments. Stationary measurements were conducted by two Pandora, two Zenith-DOAS, and two MAX-DOAS instruments. Ground-based stationary and car DOAS measurements are used to evaluate the AirMAP tropospheric NO2 VCDs and show high Pearson correlation coefficients of 0.88 and 0.89 and slopes of 0.90 ± 0.09 and 0.89 ± 0.02 for the stationary and car DOAS, respectively. Having a spatial resolution of about 100 m × 30 m, the AirMAP tropospheric NO2 VCD data create a link between the ground-based and the TROPOMI measurements with a nadir resolution of 3.5 km × 5.5 km and are therefore well suited to validate the TROPOMI tropospheric NO2 VCD. The observations on the 7 flight days show strong NO2 variability, which is dependent on the three target areas, the day of the week, and the meteorological conditions. The AirMAP campaign data set is compared to the TROPOMI NO2 operational offline (OFFL) V01.03.02 data product, the reprocessed NO2 data using the V02.03.01 of the official level-2 processor provided by the Product Algorithm Laboratory (PAL), and several scientific TROPOMI NO2 data products. The AirMAP and TROPOMI OFFL V01.03.02 data are highly correlated (r=0.87) but show an underestimation of the TROPOMI data with a slope of 0.38 ± 0.02 and a median relative difference of −9 %. With the modifications in the NO2 retrieval implemented in the PAL V02.03.01 product, the slope and median relative difference increased to 0.83 ± 0.06 and +20 %. However, the modifications resulted in larger scatter and the correlation decreased significantly to r=0.72. The results can be improved by not applying a cloud correction for the TROPOMI data in conditions with high aerosol load and when cloud pressures are retrieved close to the surface. The influence of spatially more highly resolved a priori NO2 vertical profiles and surface reflectivity are investigated using scientific TROPOMI tropospheric NO2 VCD data products. The comparison of the AirMAP campaign data set to the scientific data products shows that the choice of surface reflectivity database has a minor impact on the tropospheric NO2 VCD retrieval in the campaign region and season. In comparison, the replacement of the a priori NO2 profile in combination with the improvements in the retrieval of the PAL V02.03.01 product regarding cloud heights can further increase the tropospheric NO2 VCDs. This study demonstrates that the underestimation of the TROPOMI tropospheric NO2 VCD product with respect to the validation data set has been and can be further significantly improved.
- Open Access
- 25 October 2022
- Published by Copernicus GmbH in EGUsphere
- Vol. 2022, 1-45
Validation of Sentinel-5P TROPOMI tropospheric NO2 products by comparison with NO2 measurements from airborne imaging, ground-based stationary, and mobile car DOAS measurements during the S5P-VAL-DE-Ruhr campaign
Airborne imaging differential optical absorption spectroscopy (DOAS), ground-based stationary and car DOAS measurements were conducted during the S5P-VAL-DE-Ruhr campaign in September 2020. The campaign area is located in the Rhine-Ruhr region of North Rhine-Westphalia, Western Germany, which is a pollution hotspot in Europe comprising urban and large industrial emitters. The measurements are used to validate space-borne NO2 tropospheric vertical column density data products from the Sentinel-5 Precursor (S5P) TROPOspheric Monitoring Instrument (TROPOMI). Seven flights were performed with the airborne imaging DOAS instrument for measurements of atmospheric pollution (AirMAP), providing measurements which were used to create continuous maps of NO2 in the layer below the aircraft. These flights cover many S5P ground pixels within an area of 30 km x 35 km and were accompanied by ground-based stationary measurements and three mobile car DOAS instruments. Stationary measurements were conducted by two Pandora, two zenith-sky and two MAX-DOAS instruments distributed over three target areas. Ground-based stationary and car DOAS measurements are used to evaluate the AirMAP tropospheric NO2 vertical column densities and show high Pearson correlation coefficients of 0.87 and 0.89 and slopes of 0.93 ± 0.09 and 0.98 ± 0.02 for the stationary and car DOAS, respectively. Having a spatial resolution of about 100 m x 30 m, the AirMAP tropospheric NO2 vertical column density (VCD) data creates a link between the ground-based and the TROPOMI measurements with a resolution of 3.5 km x 5.5 km and is therefore well suited to validate the TROPOMI tropospheric NO2 VCD. The measurements on the seven flight days show strong NO2 variability, which is dependent on the different target areas, the weekday, and the meteorological conditions. The AirMAP campaign dataset is compared to the TROPOMI NO2 operational off-line (OFFL) V01.03.02 data product, the reprocessed NO2 data, using the V02.03.01 of the official L2 processor, provided by the Product Algorithm Laboratory (PAL), and several scientific TROPOMI NO2 data products. The TROPOMI data products and the AirMAP data are highly correlated with correlation coefficients between 0.72 and 0.87, and slopes of 0.38 ± 0.02 to 1.02 ± 0.07. On average, TROPOMI tropospheric NO2 VCDs are lower than the AirMAP NO2 results. The slope increased from 0.38 ± 0.02 for the operational OFFL V01.03.02 product to 0.83 ± 0.06 after the improvements in the retrieval of the PAL V02.03.01 product were implemented. Different auxiliary data, such as spatially higher resolved a priori NO2 vertical profiles, surface reflectivity and the cloud treatment, are investigated using scientific TROPOMI tropospheric NO2 VCD data products to evaluate their impact on the operational TROPOMI NO2 VCD data product. The comparison of the AirMAP campaign dataset to the scientific data products shows that the choice of surface reflectivity data base has a minor impact on the tropospheric NO2 VCD retrieval in the campaign region and season. In comparison, the replacement of the a priori NO2 profile in combination with the improvements in the retrieval of the PAL V02.03.01 product regarding cloud heights has a major impact on the tropospheric NO2 VCD retrieval and increases the slope from 0.88 ± 0.06 to 1.00 ± 0.07. This study demonstrates that the underestimation of the TROPOMI tropospheric NO2 VCD product with respect to the validation dataset has been and can be further significantly improved.
- 25 October 2022
- Published by Copernicus GmbH in EGUsphere
- Vol. 2022, 1-45
Open AccessValidation of Sentinel-5P TROPOMI tropospheric NO2 products by comparison with NO2 measurements from airborne imaging, ground-based stationary, and mobile car DOAS measurements during the S5P-VAL-DE-Ruhr campaign
Airborne imaging differential optical absorption spectroscopy (DOAS), ground-based stationary and car DOAS measurements were conducted during the S5P-VAL-DE-Ruhr campaign in September 2020. The campaign area is located in the Rhine-Ruhr region of North Rhine-Westphalia, Western Germany, which is a pollution hotspot in Europe comprising urban and large industrial emitters. The measurements are used to validate space-borne NO2 tropospheric vertical column density data products from the Sentinel-5 Precursor (S5P) TROPOspheric Monitoring Instrument (TROPOMI). Seven flights were performed with the airborne imaging DOAS instrument for measurements of atmospheric pollution (AirMAP), providing measurements which were used to create continuous maps of NO2 in the layer below the aircraft. These flights cover many S5P ground pixels within an area of 30 km x 35 km and were accompanied by ground-based stationary measurements and three mobile car DOAS instruments. Stationary measurements were conducted by two Pandora, two zenith-sky and two MAX-DOAS instruments distributed over three target areas. Ground-based stationary and car DOAS measurements are used to evaluate the AirMAP tropospheric NO2 vertical column densities and show high Pearson correlation coefficients of 0.87 and 0.89 and slopes of 0.93 ± 0.09 and 0.98 ± 0.02 for the stationary and car DOAS, respectively. Having a spatial resolution of about 100 m x 30 m, the AirMAP tropospheric NO2 vertical column density (VCD) data creates a link between the ground-based and the TROPOMI measurements with a resolution of 3.5 km x 5.5 km and is therefore well suited to validate the TROPOMI tropospheric NO2 VCD. The measurements on the seven flight days show strong NO2 variability, which is dependent on the different target areas, the weekday, and the meteorological conditions. The AirMAP campaign dataset is compared to the TROPOMI NO2 operational off-line (OFFL) V01.03.02 data product, the reprocessed NO2 data, using the V02.03.01 of the official L2 processor, provided by the Product Algorithm Laboratory (PAL), and several scientific TROPOMI NO2 data products. The TROPOMI data products and the AirMAP data are highly correlated with correlation coefficients between 0.72 and 0.87, and slopes of 0.38 ± 0.02 to 1.02 ± 0.07. On average, TROPOMI tropospheric NO2 VCDs are lower than the AirMAP NO2 results. The slope increased from 0.38 ± 0.02 for the operational OFFL V01.03.02 product to 0.83 ± 0.06 after the improvements in the retrieval of the PAL V02.03.01 product were implemented. Different auxiliary data, such as spatially higher resolved a priori NO2 vertical profiles, surface reflectivity and the cloud treatment, are investigated using scientific TROPOMI tropospheric NO2 VCD data products to evaluate their impact on the operational TROPOMI NO2 VCD data product. The comparison of the AirMAP campaign dataset to the scientific data products shows that the choice of surface reflectivity data base has a minor impact on the tropospheric NO2 VCD retrieval in the campaign region and season. In comparison, the replacement of the a priori NO2 profile in combination with the improvements in the retrieval of the PAL V02.03.01 product regarding cloud heights has a major impact on the tropospheric NO2 VCD retrieval and increases the slope from 0.88 ± 0.06 to 1.00 ± 0.07. This study demonstrates that the underestimation of the TROPOMI tropospheric NO2 VCD product with respect to the validation dataset has been and can be further significantly improved.