Latest Publications
- Open Access
- 12 December 2025
- Published by Elsevier in International Journal of Electrical Power & Energy Systems
- Vol. 174
Data-driven emission analysis of on-board chargers and large AC charging sites of electric vehicles
- 12 December 2025
- Published by Elsevier in International Journal of Electrical Power & Energy Systems
- Vol. 174
Open AccessData-driven emission analysis of on-board chargers and large AC charging sites of electric vehicles
- Open Access
- 21 September 2022
- Published by Elsevier in Sustainable Energy, Grids and Networks
- Vol. 32
A data collection and supplementary control platform of a modern building for smart energy applications
- 21 September 2022
- Published by Elsevier in Sustainable Energy, Grids and Networks
- Vol. 32
Open AccessA data collection and supplementary control platform of a modern building for smart energy applications
- 27 October 2016
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-10
Grid-connected PV power plant induced power quality problems — Experimental evidence
This paper presents new findings on phenomena contributing to flicker and voltage variations caused by grid-connected photovoltaic (PV) inverters. The voltage variations caused by two different 6 kW single-phase grid-connected PV inverters were studied during climatic variations by varying their grid-coupling impedance. Two different methods for characterizing the PV-plant induced voltage variations were studied: the short-term flicker index (Pst) and the 10 minute very-short voltage variation value (VSV). The results clearly indicate that PV inverter power fluctuations induced by cloud shading and enhancement have a significant effect on the VSV value, but not on Pst. PV inverters have a clear effect on the Pst as well, but the main contributors are related to the inverter design rather than the power fluctuations caused by clouds. The main contributor in the elevated Pst values could be traced back to the poor design of the maximum power point tracking (MPPT) of the inverters. The MPPT caused subharmonic current variations at a frequency of approximately 8 Hz which is close to the most sensitive frequency of human eye. Another factor causing rapid voltage variations in low irradiance conditions was the current transients related to the inverter start-up and shut-down. Harmonic current distortion is also a potential PV inverter related power quality (PQ) issue. This study indicates that although the current total harmonic distortion (THD) may be very large at low power levels the total demand distortion (TDD) of the PV inverters is almost constant regardless of the output power and the harmonic current had only a very limited effect on the voltage quality even at the weakest network having a short-circuit current of Isc=250 A. Thus, voltage variations caused by the PV inverters were the main PQ issue in the studied networks. The investigations also clearly show that a part of the power quality problems found in the PV plants are caused by the poor design of the PV inverters.
- 27 October 2016
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-10
Grid-connected PV power plant induced power quality problems — Experimental evidence
This paper presents new findings on phenomena contributing to flicker and voltage variations caused by grid-connected photovoltaic (PV) inverters. The voltage variations caused by two different 6 kW single-phase grid-connected PV inverters were studied during climatic variations by varying their grid-coupling impedance. Two different methods for characterizing the PV-plant induced voltage variations were studied: the short-term flicker index (Pst) and the 10 minute very-short voltage variation value (VSV). The results clearly indicate that PV inverter power fluctuations induced by cloud shading and enhancement have a significant effect on the VSV value, but not on Pst. PV inverters have a clear effect on the Pst as well, but the main contributors are related to the inverter design rather than the power fluctuations caused by clouds. The main contributor in the elevated Pst values could be traced back to the poor design of the maximum power point tracking (MPPT) of the inverters. The MPPT caused subharmonic current variations at a frequency of approximately 8 Hz which is close to the most sensitive frequency of human eye. Another factor causing rapid voltage variations in low irradiance conditions was the current transients related to the inverter start-up and shut-down. Harmonic current distortion is also a potential PV inverter related power quality (PQ) issue. This study indicates that although the current total harmonic distortion (THD) may be very large at low power levels the total demand distortion (TDD) of the PV inverters is almost constant regardless of the output power and the harmonic current had only a very limited effect on the voltage quality even at the weakest network having a short-circuit current of Isc=250 A. Thus, voltage variations caused by the PV inverters were the main PQ issue in the studied networks. The investigations also clearly show that a part of the power quality problems found in the PV plants are caused by the poor design of the PV inverters.
- 1 November 2015
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-6
A versatile solution for continuous on-line PD monitoring
Smart Grid concept substantially increases the power measurement need in the future for efficient and guaranteed power delivery. The medium voltage (MV) cable is an important asset of a distribution network and it must guarantee a stable operation of the supply. With the increasing age of the underground MV cables in power grids, the accident and failure arising from insulation degradation is becoming one of the main challenges against power system reliability. It is also essential economically to extend the life span of the medium voltage cable. Continuous on-line partial discharge (PD) monitoring is an excellent way to determine the overall health of the MV components and to detect incipient faults in underground cables. However, continuous on-line PD monitoring is not widely used primarily because no adequate cost-effective solution is available for permanent installation. This paper presents the development of a versatile solution for continuous on-line PD monitoring of MV cables at secondary substation. The laboratory tests and data analysis exhibit the capability of the proposed system to detect PD signals successfully.
- 1 November 2015
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-6
A versatile solution for continuous on-line PD monitoring
Smart Grid concept substantially increases the power measurement need in the future for efficient and guaranteed power delivery. The medium voltage (MV) cable is an important asset of a distribution network and it must guarantee a stable operation of the supply. With the increasing age of the underground MV cables in power grids, the accident and failure arising from insulation degradation is becoming one of the main challenges against power system reliability. It is also essential economically to extend the life span of the medium voltage cable. Continuous on-line partial discharge (PD) monitoring is an excellent way to determine the overall health of the MV components and to detect incipient faults in underground cables. However, continuous on-line PD monitoring is not widely used primarily because no adequate cost-effective solution is available for permanent installation. This paper presents the development of a versatile solution for continuous on-line PD monitoring of MV cables at secondary substation. The laboratory tests and data analysis exhibit the capability of the proposed system to detect PD signals successfully.