Mehdi Ghiai
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Mehdi Ghiai has a total of 34 co-authors. Here are the top co-authors by number of shared publications:
Sepideh Niknia
Huckabee College of Architecture, Texas Tech University, Lubbock, USA
3 shared publications- Sepideh Niknia
Texas Tech University, Lubbock, TX, USA
3 shared publications Christian Bassaw
Department of Design, Texas Tech University, Lubbock, USA
2 shared publicationsJamal Tabe Arjmand
Faculty of Architecture and Urban Planning, University of Art, Tehran, Iran
2 shared publications- Marjan Pahlevani
University of Louisiana at Lafayette
2 shared publications Zahra Khodaee
Islamic Azad University
2 shared publications
Latest Publications
- Open Access
- 27 September 2026
- Published by Springer Nature in Discover Sustainability
A multi-timescale post-occupancy evaluation of indoor environmental quality in an occupied university building
- 27 September 2026
- Published by Springer Nature in Discover Sustainability
Open AccessA multi-timescale post-occupancy evaluation of indoor environmental quality in an occupied university building
- 13 August 2026
- Published by SAGE Publications in WORK: A Journal of Prevention, Assessment & Rehabilitation
The influence of the physical work environment on presenteeism: A theoretical exploration
Background: Presenteeism, defined as attending work despite reduced functional capacity, has been widely studied in occupational health and organizational research. However, the role of the physical work environment remains underexplored and inconsistently integrated into dominant conceptual models. Objective: This integrative review examines the role of the physical work environment in presenteeism in knowledge-intensive workplaces, while considering organizational structures and health-related resources, and synthesizes these relationships into a unified theoretical framework. Methods: A structured search and synthesis procedure was conducted across five databases (Scopus, Web of Science, PubMed, PsycINFO, and Google Scholar), yielding 28 articles that met the inclusion and exclusion criteria. Studies were synthesized using thematic and comparative analysis across three domains: physical environmental exposures, organizational conditions, and individual psychological factors. Results: Environmental exposures, including noise, air quality, lighting, thermal comfort, and ergonomics, are linked to reduced work functioning alongside attendance norms, job demands, and resource depletion. Presenteeism emerges from the combined influence of workplace context and individual capacity, with impaired functioning contributing to further resource depletion over time. The review presents the Integrated Multifactor Framework of Presenteeism (IMFP), which organizes these relationships into a coherent theoretical framework. Conclusions: The IMFP extends existing models by incorporating the physical environment as a structural input and specifying a recursive feedback process between outcomes and resource depletion. The framework provides a theoretical foundation for future empirical investigation and targeted workplace interventions to reduce presenteeism.
- 13 August 2026
- Published by SAGE Publications in WORK: A Journal of Prevention, Assessment & Rehabilitation
The influence of the physical work environment on presenteeism: A theoretical exploration
Background: Presenteeism, defined as attending work despite reduced functional capacity, has been widely studied in occupational health and organizational research. However, the role of the physical work environment remains underexplored and inconsistently integrated into dominant conceptual models. Objective: This integrative review examines the role of the physical work environment in presenteeism in knowledge-intensive workplaces, while considering organizational structures and health-related resources, and synthesizes these relationships into a unified theoretical framework. Methods: A structured search and synthesis procedure was conducted across five databases (Scopus, Web of Science, PubMed, PsycINFO, and Google Scholar), yielding 28 articles that met the inclusion and exclusion criteria. Studies were synthesized using thematic and comparative analysis across three domains: physical environmental exposures, organizational conditions, and individual psychological factors. Results: Environmental exposures, including noise, air quality, lighting, thermal comfort, and ergonomics, are linked to reduced work functioning alongside attendance norms, job demands, and resource depletion. Presenteeism emerges from the combined influence of workplace context and individual capacity, with impaired functioning contributing to further resource depletion over time. The review presents the Integrated Multifactor Framework of Presenteeism (IMFP), which organizes these relationships into a coherent theoretical framework. Conclusions: The IMFP extends existing models by incorporating the physical environment as a structural input and specifying a recursive feedback process between outcomes and resource depletion. The framework provides a theoretical foundation for future empirical investigation and targeted workplace interventions to reduce presenteeism.
- Open Access
- 13 August 2026
- Published by MDPI AG in Sustainability
- Vol. 18 (16) , 8306
Where Green Building Certification Falls Short of Biophilic Design: A Pattern Analysis of LEED v5 and WELL v2
Biophilic design connects people to nature through direct, indirect, and spatial experiences, yet how systematically LEED v5 and WELL v2 represent these dimensions remains insufficiently understood. This study examines how and to what extent LEED v5 BD+C and WELL v2 optional scoring components represent biophilic design, using 14 Patterns of Biophilic Design as a common analytical framework. Optional LEED v5 credits and WELL v2 optimization features were screened for biophilic relevance, mapped to a primary pattern, and scored for alignment strength on a 0–3 scale. Representation was limited on every measure. Only 9 of 34 LEED v5 optional credits (26.5%) and 11 of 84 WELL v2 optimization features (13.1%) qualified as biophilically relevant, and only 3 credits (8.8%) and 4 features (4.8%) showed strong and direct alignment. LEED v5 addressed 7 of the 14 patterns and WELL v2 only 5; the remaining 7, including Mystery, Risk/Peril, Biomorphic Forms and Patterns, and Complexity and Order, received no primary representation in either system. Nature in the Space accounted for 17 of the 20 qualifying items (85%). LEED v5 showed a more site- and ecology-oriented profile, particularly through Connection with Natural Systems, while WELL v2 concentrated more on occupant-centered indoor environmental conditions, especially lighting, daylight, airflow, and thermal comfort. These findings suggest that, within the optional components analyzed, biophilic design is more readily represented where it overlaps with measurable and documentable criteria. Experiential, symbolic, and psychological–spatial dimensions are largely absent from the primary pattern assignments. The study contributes a transparent procedure for screening, mapping, and scoring biophilic content across rating systems. Given the small number of qualifying items and the interpretive nature of pattern scoring, the findings are presented as a documentation-based, pattern-level critique rather than a statistical ranking of the two systems.
- 13 August 2026
- Published by MDPI AG in Sustainability
- Vol. 18 (16) , 8306
Open AccessWhere Green Building Certification Falls Short of Biophilic Design: A Pattern Analysis of LEED v5 and WELL v2
Biophilic design connects people to nature through direct, indirect, and spatial experiences, yet how systematically LEED v5 and WELL v2 represent these dimensions remains insufficiently understood. This study examines how and to what extent LEED v5 BD+C and WELL v2 optional scoring components represent biophilic design, using 14 Patterns of Biophilic Design as a common analytical framework. Optional LEED v5 credits and WELL v2 optimization features were screened for biophilic relevance, mapped to a primary pattern, and scored for alignment strength on a 0–3 scale. Representation was limited on every measure. Only 9 of 34 LEED v5 optional credits (26.5%) and 11 of 84 WELL v2 optimization features (13.1%) qualified as biophilically relevant, and only 3 credits (8.8%) and 4 features (4.8%) showed strong and direct alignment. LEED v5 addressed 7 of the 14 patterns and WELL v2 only 5; the remaining 7, including Mystery, Risk/Peril, Biomorphic Forms and Patterns, and Complexity and Order, received no primary representation in either system. Nature in the Space accounted for 17 of the 20 qualifying items (85%). LEED v5 showed a more site- and ecology-oriented profile, particularly through Connection with Natural Systems, while WELL v2 concentrated more on occupant-centered indoor environmental conditions, especially lighting, daylight, airflow, and thermal comfort. These findings suggest that, within the optional components analyzed, biophilic design is more readily represented where it overlaps with measurable and documentable criteria. Experiential, symbolic, and psychological–spatial dimensions are largely absent from the primary pattern assignments. The study contributes a transparent procedure for screening, mapping, and scoring biophilic content across rating systems. Given the small number of qualifying items and the interpretive nature of pattern scoring, the findings are presented as a documentation-based, pattern-level critique rather than a statistical ranking of the two systems.
- Open Access
- 2 June 2026
- Published by Frontiers Media SA in Frontiers in Built Environment
- Vol. 12, 1837203
Post-occupancy evaluation and human-centered indoor environmental quality in higher-education buildings: a structured review
The ongoing discrepancy between predicted and actual building performance has reinforced the need for post-occupancy evaluation (POE) to ensure that higher education facilities meet the demand for stable indoor conditions to support learning, teaching, and administrative activities. This literature review synthesized findings from the existing literature on a human-centered approach to indoor environmental quality (IEQ) that combines objective measurements with occupants’ perception of comfort, satisfaction, symptoms, and perceived control. A structured literature search was conducted using Scopus, Web of Science, ScienceDirect, and Google Scholar to synthesize 43 review articles and empirical studies on the relationship among four major IEQ factors. The findings revealed that all IEQ factors can affect occupants’ fatigue, concentration, decision-making, stress, and satisfaction, with perceived control and adaptation playing a moderate role in most cases. It also revealed that adherence to technical standards and rating systems (ASHRAE, LEED, and WELL) does not guarantee satisfaction with IEQ. This paper concludes that the proposed mixed-methodology for POE has the potential to support continuous facility operations, resolve conflicts between energy efficiency and user satisfaction, and inform the design and management of healthy and high-performing university facilities. In this study, a human-centered Post-Occupancy Evaluation (POE) framework that incorporates objective indoor environmental quality metrics and perceptions with decision-making processes in higher education facilities.
- 2 June 2026
- Published by Frontiers Media SA in Frontiers in Built Environment
- Vol. 12, 1837203
Open AccessPost-occupancy evaluation and human-centered indoor environmental quality in higher-education buildings: a structured review
The ongoing discrepancy between predicted and actual building performance has reinforced the need for post-occupancy evaluation (POE) to ensure that higher education facilities meet the demand for stable indoor conditions to support learning, teaching, and administrative activities. This literature review synthesized findings from the existing literature on a human-centered approach to indoor environmental quality (IEQ) that combines objective measurements with occupants’ perception of comfort, satisfaction, symptoms, and perceived control. A structured literature search was conducted using Scopus, Web of Science, ScienceDirect, and Google Scholar to synthesize 43 review articles and empirical studies on the relationship among four major IEQ factors. The findings revealed that all IEQ factors can affect occupants’ fatigue, concentration, decision-making, stress, and satisfaction, with perceived control and adaptation playing a moderate role in most cases. It also revealed that adherence to technical standards and rating systems (ASHRAE, LEED, and WELL) does not guarantee satisfaction with IEQ. This paper concludes that the proposed mixed-methodology for POE has the potential to support continuous facility operations, resolve conflicts between energy efficiency and user satisfaction, and inform the design and management of healthy and high-performing university facilities. In this study, a human-centered Post-Occupancy Evaluation (POE) framework that incorporates objective indoor environmental quality metrics and perceptions with decision-making processes in higher education facilities.
- Open Access
- 26 May 2026
- Published by MDPI AG in Preprints.org
Post-Occupancy Evaluation to Examine the Quality of Female Student Housing Facilities: A Case Study of Iran
Student living environments have a significant impact on educational quality and academic outcomes. However, limited empirical research has focused on the condition of female student housing in Iran. This study conducts a post-occupancy evaluation (POE) of a representative on-campus female dormitory (Eram 3) at Shiraz University. A comprehensive evaluation framework was developed through an extensive literature review and structured into eleven performance indicators across three key dimensions: technical, functional, and behavioral. Data was collected using a 65-item questionnaire completed by 62 students who had resided in the building for at least one semester. Additional qualitative insights were gathered through focus group discussions and systematic observation, enhancing the reliability and contextual depth of the findings. Results indicate widespread dissatisfaction among residents, particularly in relation to indoor air quality, lighting, room layout, and privacy. The technical dimension received the lowest satisfaction scores, especially concerning air quality and lighting. Functionally, residents reported inadequate room sizes and limited flexibility in furniture arrangement. The behavioral dimension revealed dissatisfaction with visual privacy and the aesthetic quality of interior spaces. Based on these findings, the study proposes targeted improvements to ventilation systems, artificial and natural lighting, acoustic performance, and spatial layout. The research contributes to a gender-sensitive, user-centered POE framework applicable to similar residential environments in developing countries.
- 26 May 2026
- Published by MDPI AG in Preprints.org
Open AccessPost-Occupancy Evaluation to Examine the Quality of Female Student Housing Facilities: A Case Study of Iran
Student living environments have a significant impact on educational quality and academic outcomes. However, limited empirical research has focused on the condition of female student housing in Iran. This study conducts a post-occupancy evaluation (POE) of a representative on-campus female dormitory (Eram 3) at Shiraz University. A comprehensive evaluation framework was developed through an extensive literature review and structured into eleven performance indicators across three key dimensions: technical, functional, and behavioral. Data was collected using a 65-item questionnaire completed by 62 students who had resided in the building for at least one semester. Additional qualitative insights were gathered through focus group discussions and systematic observation, enhancing the reliability and contextual depth of the findings. Results indicate widespread dissatisfaction among residents, particularly in relation to indoor air quality, lighting, room layout, and privacy. The technical dimension received the lowest satisfaction scores, especially concerning air quality and lighting. Functionally, residents reported inadequate room sizes and limited flexibility in furniture arrangement. The behavioral dimension revealed dissatisfaction with visual privacy and the aesthetic quality of interior spaces. Based on these findings, the study proposes targeted improvements to ventilation systems, artificial and natural lighting, acoustic performance, and spatial layout. The research contributes to a gender-sensitive, user-centered POE framework applicable to similar residential environments in developing countries.
- Open Access
- 7 April 2026
- Published by European Association for Architectural Education in EAAE Joint Publishings
Manufactured Homes: Accessibility, Resilience, and Enhanced Quality of Life in Three Extreme Climates
This paper asks what can we learn from homeowner modifications of manufactured homes about addressing resilience, accommodation, energy savings, occupation, and flexibility? The authors identify retrofits which decrease heating and/or cooling requirements; provide long term accessibility as owner’s age; plan resilience in the face of extreme weather; and enhance quality of life aligned with local culture. Three rural extreme climates in Louisiana, Arizona, and Colorado provide data on a wide range of solutions tailored to the particularities of climate conditions. The resulting assessment identifies categories of modifications and retrofits and associated typologies, for example homes on piers, unconditioned porch or carport additions, conditioned additions, envelope modifications, and changes to provide ADA accessibility. Quantified assessment through energy and structural modeling evaluates the effectiveness of the homeowner designed retrofits observed in Louisiana, Arizona, and Colorado. The results of assessment reveal that homeowners decreased EUI through simple passive methods adapted from agricultural, aquacultural, and industrial architecture. Energy modeling simulation on case studies for observed retrofit roof assemblies showed up to a 28% decrease in EUI in Louisiana, and 58% decrease in EUI in Arizona. These same retrofits produce large exterior covered occupiable spaces which provide an extended period of thermal comfort by over 20%. While the paper primarily focuses upon assessment of heating/cooling mitigation through roof assembly retrofit, it also discusses: structural changes through the addition of piers, super structure, and lifting systems along with accessibility and circulation changes, all due to accommodation of FEMA base flood height elevation in Louisiana; window retrofits, window shading, and understory/crawlspace protection and skirting to both provide resilience during climatic events, but also to mitigate heat transfer in manufactured homes in Arizona and Colorado; and heating/cooling source retrofits and augmentation in all three locations.
- 7 April 2026
- Published by European Association for Architectural Education in EAAE Joint Publishings
Open AccessManufactured Homes: Accessibility, Resilience, and Enhanced Quality of Life in Three Extreme Climates
This paper asks what can we learn from homeowner modifications of manufactured homes about addressing resilience, accommodation, energy savings, occupation, and flexibility? The authors identify retrofits which decrease heating and/or cooling requirements; provide long term accessibility as owner’s age; plan resilience in the face of extreme weather; and enhance quality of life aligned with local culture. Three rural extreme climates in Louisiana, Arizona, and Colorado provide data on a wide range of solutions tailored to the particularities of climate conditions. The resulting assessment identifies categories of modifications and retrofits and associated typologies, for example homes on piers, unconditioned porch or carport additions, conditioned additions, envelope modifications, and changes to provide ADA accessibility. Quantified assessment through energy and structural modeling evaluates the effectiveness of the homeowner designed retrofits observed in Louisiana, Arizona, and Colorado. The results of assessment reveal that homeowners decreased EUI through simple passive methods adapted from agricultural, aquacultural, and industrial architecture. Energy modeling simulation on case studies for observed retrofit roof assemblies showed up to a 28% decrease in EUI in Louisiana, and 58% decrease in EUI in Arizona. These same retrofits produce large exterior covered occupiable spaces which provide an extended period of thermal comfort by over 20%. While the paper primarily focuses upon assessment of heating/cooling mitigation through roof assembly retrofit, it also discusses: structural changes through the addition of piers, super structure, and lifting systems along with accessibility and circulation changes, all due to accommodation of FEMA base flood height elevation in Louisiana; window retrofits, window shading, and understory/crawlspace protection and skirting to both provide resilience during climatic events, but also to mitigate heat transfer in manufactured homes in Arizona and Colorado; and heating/cooling source retrofits and augmentation in all three locations.
- Open Access
- 21 March 2026
- Published by Springer Nature in Scientific Reports
- Vol. 16 (1)
Comparing daylight performance of dynamic and static shadings in office façades across multiple U.S. cities with various sky conditions
Shadings have a crucial role in daylight performance of buildings; however, their impact is dependent on both sky conditions and shading specifications. This study investigates the daylight performance of both dynamic shading systems and compares them with static shading at various rotation angles in a nearly fully glazed office unit. In addition to rotation angle, shading geometry and sky condition are examined to evaluate their combined impact on façade performance. The Hourly Useful Illuminance (HUI) metric is introduced to assess hourly illumination levels for three International Commission on Illumination sky types: sunny with sun, intermediate with sun, and cloudy. Simulations reveal that both dynamic and static shadings perform better under sunny skies than under intermediate ones, and both negatively affect daylight performance under cloudy conditions, with dynamic shadings showing greater superiority under sunny and intermediate skies. The superiority of dynamic shadings was greater in Las Vegas with a sunny sky; the difference of HUI between dynamic and static shadings is 4.5 for rectangular and 5.7 for triangular shadings. Rectangular geometries perform slightly better than triangular ones, though the difference is marginal. The study also determines optimum rotation angles for dynamic and static shadings and shows that as cloudiness increases, the range of effective rotation angles narrows. Additionally, analysis across multiple cities indicates that the decline in the useful illuminance level (HUI) at some time steps corresponds to changes in solar altitude and sky brightness, occurring around noon under sunny conditions and during midday and the summer season under intermediate skies.
- 21 March 2026
- Published by Springer Nature in Scientific Reports
- Vol. 16 (1)
Open AccessComparing daylight performance of dynamic and static shadings in office façades across multiple U.S. cities with various sky conditions
Shadings have a crucial role in daylight performance of buildings; however, their impact is dependent on both sky conditions and shading specifications. This study investigates the daylight performance of both dynamic shading systems and compares them with static shading at various rotation angles in a nearly fully glazed office unit. In addition to rotation angle, shading geometry and sky condition are examined to evaluate their combined impact on façade performance. The Hourly Useful Illuminance (HUI) metric is introduced to assess hourly illumination levels for three International Commission on Illumination sky types: sunny with sun, intermediate with sun, and cloudy. Simulations reveal that both dynamic and static shadings perform better under sunny skies than under intermediate ones, and both negatively affect daylight performance under cloudy conditions, with dynamic shadings showing greater superiority under sunny and intermediate skies. The superiority of dynamic shadings was greater in Las Vegas with a sunny sky; the difference of HUI between dynamic and static shadings is 4.5 for rectangular and 5.7 for triangular shadings. Rectangular geometries perform slightly better than triangular ones, though the difference is marginal. The study also determines optimum rotation angles for dynamic and static shadings and shows that as cloudiness increases, the range of effective rotation angles narrows. Additionally, analysis across multiple cities indicates that the decline in the useful illuminance level (HUI) at some time steps corresponds to changes in solar altitude and sky brightness, occurring around noon under sunny conditions and during midday and the summer season under intermediate skies.
- Open Access
- 17 November 2025
- Published by Springer Nature in Research Square
Simulation-Based Assessment of Construction Phase Environmental Impacts for Tall Buildings Structural Systems
The construction phase of tall buildings plays a significant role in environmental degradation due to the intensive use of materials, high energy consumption, and emissions from on-site activities. This study examines the environmental impacts associated with the construction process of tall office buildings by integrating Building Information Modeling (BIM) and Life Cycle Assessment (LCA). A generic model representing common structural systems and material configurations was developed in Autodesk Revit. Grasshopper and Karamba 3D were utilized to optimize the structural system, enhancing its performance and efficiency. The environmental impact of the construction process, Stage A5 of the building life cycle, as defined by EN 15978 standards, was then assessed using the Tally plugin. MATLAB was used to quantify the energy consumption and CO₂ emissions of the optimized structure. Then, different construction scenarios were optimized using VSGA-III, providing a more precise evaluation of the system’s environmental performance. An LCA analysis was conducted using the Tally plugin within Revit to highlight key impact factors, including fossil fuel depletion, global warming potential, and construction waste. By combining BIM, structural optimization, and advanced analytical tools, this framework provides a reliable tool for early-stage environmental assessments of tall buildings' structural systems, helping architects and designers to make informed decisions to minimize environmental impacts during the construction phase of tall buildings. This process might lead to New or revised green building certifications, Changes in regulatory requirements, and this framework could become a new standard for designing sustainable tall buildings, influencing industry practices and promoting the adoption of sustainable design principles. This study quantified measurable outcomes, including an 18% reduction in CO₂ emissions, a 22% reduction in energy consumption, and a 17% reduction in smog formation potential, thereby demonstrating the framework’s practical effectiveness in minimizing Stage A5 environmental impacts. Future studies could expand this framework by incorporating additional life cycle stages, testing real-world construction projects, and integrating renewable energy solutions or automation strategies to further enhance sustainability outcomes.
- 17 November 2025
- Published by Springer Nature in Research Square
Open AccessSimulation-Based Assessment of Construction Phase Environmental Impacts for Tall Buildings Structural Systems
The construction phase of tall buildings plays a significant role in environmental degradation due to the intensive use of materials, high energy consumption, and emissions from on-site activities. This study examines the environmental impacts associated with the construction process of tall office buildings by integrating Building Information Modeling (BIM) and Life Cycle Assessment (LCA). A generic model representing common structural systems and material configurations was developed in Autodesk Revit. Grasshopper and Karamba 3D were utilized to optimize the structural system, enhancing its performance and efficiency. The environmental impact of the construction process, Stage A5 of the building life cycle, as defined by EN 15978 standards, was then assessed using the Tally plugin. MATLAB was used to quantify the energy consumption and CO₂ emissions of the optimized structure. Then, different construction scenarios were optimized using VSGA-III, providing a more precise evaluation of the system’s environmental performance. An LCA analysis was conducted using the Tally plugin within Revit to highlight key impact factors, including fossil fuel depletion, global warming potential, and construction waste. By combining BIM, structural optimization, and advanced analytical tools, this framework provides a reliable tool for early-stage environmental assessments of tall buildings' structural systems, helping architects and designers to make informed decisions to minimize environmental impacts during the construction phase of tall buildings. This process might lead to New or revised green building certifications, Changes in regulatory requirements, and this framework could become a new standard for designing sustainable tall buildings, influencing industry practices and promoting the adoption of sustainable design principles. This study quantified measurable outcomes, including an 18% reduction in CO₂ emissions, a 22% reduction in energy consumption, and a 17% reduction in smog formation potential, thereby demonstrating the framework’s practical effectiveness in minimizing Stage A5 environmental impacts. Future studies could expand this framework by incorporating additional life cycle stages, testing real-world construction projects, and integrating renewable energy solutions or automation strategies to further enhance sustainability outcomes.
- Open Access
Enhancing Outdoor Environmental Comfort: A Review of Façade-Surface Strategies and Microclimate Impacts
Building façades traditionally focus on enhancing indoor environmental quality and improving energy performance, but undermine their influence on Outdoor Environmental Comfort (OEC), including thermal, acoustic, and visual conditions. With technological advancements in envelope design, research on new materials and green systems has been introduced in the last few decades. This review examines the role of two key elements—façade materials and green façades—in shaping OEC. A total of 41 peer-reviewed studies (24 on urban scale and 17 on building scale) were categorized into three focus areas: (1) outdoor thermal comfort; (2) outdoor acoustic comfort; and (3) outdoor visual comfort. The analysis was structured across three levels: (a) Performance Determinants; (b) Metrics/Models; and (c) Material or Façade Types. We proposed this analytical structure to highlight the interactions between building façades and OEC domains (thermal, acoustic, and visual comfort). Our results showed façade treatment can impact all three comfort factors related to OEC, but trade-offs must be evaluated. Moreover, the findings highlighted that additional research is required to cover variations in both climate and context conditions, due to their close association with the OEC. Finally, the conceptual framework is presented to synthesize the three comfort domains for sustainable outdoor environments.
Open AccessEnhancing Outdoor Environmental Comfort: A Review of Façade-Surface Strategies and Microclimate Impacts
Building façades traditionally focus on enhancing indoor environmental quality and improving energy performance, but undermine their influence on Outdoor Environmental Comfort (OEC), including thermal, acoustic, and visual conditions. With technological advancements in envelope design, research on new materials and green systems has been introduced in the last few decades. This review examines the role of two key elements—façade materials and green façades—in shaping OEC. A total of 41 peer-reviewed studies (24 on urban scale and 17 on building scale) were categorized into three focus areas: (1) outdoor thermal comfort; (2) outdoor acoustic comfort; and (3) outdoor visual comfort. The analysis was structured across three levels: (a) Performance Determinants; (b) Metrics/Models; and (c) Material or Façade Types. We proposed this analytical structure to highlight the interactions between building façades and OEC domains (thermal, acoustic, and visual comfort). Our results showed façade treatment can impact all three comfort factors related to OEC, but trade-offs must be evaluated. Moreover, the findings highlighted that additional research is required to cover variations in both climate and context conditions, due to their close association with the OEC. Finally, the conceptual framework is presented to synthesize the three comfort domains for sustainable outdoor environments.
- Open Access
- 5 July 2025
- Published by MDPI AG in Sustainability
- Vol. 17 (13) , 6179
Energy and Sustainability Impacts of U.S. Buildings Under Future Climate Scenarios
Projected changes in outdoor environmental conditions are expected to significantly alter building energy demand across the United States. Yet, policymakers and designers lack typology and climate-zone-specific guidance to support long-term planning. We simulated 10 U.S. Department of Energy (DOE) prototype buildings across all 16 ASHRAE climate zones with EnergyPlus. Future weather files generated in Meteonorm from a CMIP6 ensemble reflected two emissions pathways (RCP 4.5 and RCP 8.5) and two planning horizons (2050 and 2080), producing 800 simulations. Envelope parameters and schedules were held at DOE reference values to isolate the pure climate signal. Results show that cooling energy use intensity (EUI) in very hot-humid Zones 1A–2A climbs by 12% for full-service restaurants and 21% for medium offices by 2080 under RCP 8.5, while heating EUI in sub-arctic Zone 8 falls by 14–20%. Hospitals and large hotels change by < 6%, showing resilience linked to high internal gains. A simple linear-regression meta-model (R2 > 0.90) links baseline EUI to future percentage change, enabling rapid screening of vulnerable stock without further simulation. These high-resolution maps supply actionable targets for state code updates, retrofit prioritization, and long-term decarbonization planning to support climate adaptation and sustainable development.
- 5 July 2025
- Published by MDPI AG in Sustainability
- Vol. 17 (13) , 6179
Open AccessEnergy and Sustainability Impacts of U.S. Buildings Under Future Climate Scenarios
Projected changes in outdoor environmental conditions are expected to significantly alter building energy demand across the United States. Yet, policymakers and designers lack typology and climate-zone-specific guidance to support long-term planning. We simulated 10 U.S. Department of Energy (DOE) prototype buildings across all 16 ASHRAE climate zones with EnergyPlus. Future weather files generated in Meteonorm from a CMIP6 ensemble reflected two emissions pathways (RCP 4.5 and RCP 8.5) and two planning horizons (2050 and 2080), producing 800 simulations. Envelope parameters and schedules were held at DOE reference values to isolate the pure climate signal. Results show that cooling energy use intensity (EUI) in very hot-humid Zones 1A–2A climbs by 12% for full-service restaurants and 21% for medium offices by 2080 under RCP 8.5, while heating EUI in sub-arctic Zone 8 falls by 14–20%. Hospitals and large hotels change by < 6%, showing resilience linked to high internal gains. A simple linear-regression meta-model (R2 > 0.90) links baseline EUI to future percentage change, enabling rapid screening of vulnerable stock without further simulation. These high-resolution maps supply actionable targets for state code updates, retrofit prioritization, and long-term decarbonization planning to support climate adaptation and sustainable development.