RNRamesh P. Nair

Ramesh P. Nair

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Ramesh P. Nair has a total of 7 co-authors. Here are the top co-authors by number of shared publications:

  • Sumangala B. Vishwanath

    Department of EEE, Ramaiah Institute of Technology, Bengaluru, Karnataka, India

    3 shared publications
  • B. Nageshwar Rao

    Central Power Research Institute, Prof. Sir C V Raman Road, PB No. 8066, Bengaluru, India

    2 shared publications
  • B. V. Sumangala

    Electrical and Electronics Engineering Department, Dr. Ambedkar Institute of Technology, Bengaluru, India

    2 shared publications
  • Burjupati Nageshwar Rao

    Central Power Research Institute, Bangalore, P.B.No. 8066, India

    1 shared publication
  • Nageshwar B. Rao

    Cables and Diagnostics Division Central Power Research Institute Bengaluru India

    1 shared publication
  • Sumangala B. Vishwanath

    Department of Electrical and Electronics Engineering Dr. Ambedkar Institute of Technology Bengaluru India

    1 shared publication

Latest Publications

  • The Applicability of Very Low Frequency Diagnostic Testing in the Evaluation of Thermally Aged Stator Coil

    by Ramesh P. Nair, Sumangala B. Vishwanath

    In this study, stator coils were aged under thermal stress and changes in insulation condition with the aging cycles were evaluated using diagnostic tests. Diagnostic tests such as partial discharge measurement and tan delta and capacitance measurements were performed at 50 Hz, 1 Hz and 0.1 Hz (very low frequency). The results obtained from this study demonstrate the possibility of evaluating the signs of thermal aging in a stator insulation system with very low frequency tests. Partial discharge parameters like peak apparent charge magnitude and integrated charge per cycle along with tan delta and capacitance tip-up values were used to evaluate the stator insulation condition. Diagnostic test results showed an identical trend with aging cycles at all the chosen test frequency, i.e. 50 Hz, 1 Hz and 0.1 Hz, which indicates that testing at 0.1 Hz is suitable for insulation condition evaluation. Further, the tip-up values have shown distinct variations, especially at 0.1 Hz indicating significant thermal degradation in a stator coil.


  • Open Access

    Analysis of partial discharge sources in stator insulation system using variable excitation frequency

    by Ramesh P. Nair, Sumangala B. Vishwanath

    Identification of partial discharge (PD) sources in stator insulation is an important and challenging task. Distinct phase‐resolved PD (PRPD) pattern of different PD sources are well established at power frequency (50/60 Hz) and can help to identify each source. In this study, different sources of PD commonly found in stator insulation were created on a 6.6 kV epoxy‐mica stator coil. Each PD source was experimentally investigated at a variable excitation frequency in the range of 50–0.1 Hz. PRPD pattern and PD parameters such as integrated charge per cycle and number of discharge pulses per cycle of each discharge source were compared at different frequencies. The comparison suggests that the parameter of each PD source was dependent on excitation frequency. Some discharge sources have shown a distinct variation in their characteristics with excitation frequency. These distinct characteristics are additional information to the existing ones, which will help to correlate PD characteristics with the source of PD in stator insulation.


  • Stator Winding Insulation Diagnosis by Very Low Frequency Techniques

    by Burjupati Nageshwar Rao, Ramesh P. Nair

    Laboratory studies were undertaken to understand the low frequency response of thermally degraded stator winding insulation. The dielectric diagnostic methods namely capacitance and tan δ measurements at different frequencies (Dielectric spectroscopy a frequency domain method) and Recovery voltage measurement (time domain method) has been used to study the dielectric response of epoxy mica insulation. Two different types of insulation systems namely Epoxy-Mica resin poor and epoxy-Mica resin rich system are evaluated. Low voltage measurements at 140 volts peak were made in the frequency range of 1 mHz to 1 kHz using Dielectric spectroscopy. The Recovery voltage measurement technique was adopted to investigate the slow polarization process in the dielectric and to assess the insulation ageing based on the analysis of polarization spectrum. This paper presents the dielectric response of epoxy mica insulation system subjected to thermal ageing.

  • Open Access

    Identification of slot discharges in rotating machine insulation system using variable frequency PD measurement

    by Ramesh P. Nair, Sumangala B. Vishwanath, Nageshwar B. Rao

    Slot discharge studies are very important from the insulation diagnosis perspective. Further in practice, testing of rotating machines with power frequency requires sources which are quite bulky and costly. Instead if the diagnosis is carried out at lower frequencies (<50 Hz), the size and cost of the test source can be reduced significantly. Therefore, it is important to know whether the study at low frequencies can be considered equivalent to study at power frequency. Hence, in this study, a slot discharge phenomenon occurring in a rotating machine insulation system was investigated experimentally at different frequencies (50, 10, 1 and 0.1 Hz). Slot discharges are known to have a distinct phase resolved partial discharge pattern for power frequency (50/60 Hz) excitation. These distinct patterns are useful in identifying the presence of slot discharge activity in rotating machines. Slot discharges were created on a 6.6 kV mica‐epoxy stator coil and the slot discharge characteristics measured at different frequencies are compared. Slot discharge measurements were repeated by varying the air gap between the insulation surface and grounded steel plate. The changes in slot discharge characteristics due to the increase in air gap were found similar at all frequencies. The comparison suggests that the identification of slot discharge is also possible from the partial discharge (PD) measurement at low frequencies.


  • Effect of temperature on slot discharge pattern measured in stator coils at variable frequency sinusoidal voltage excitation

    by Ramesh P. Nair, B. V. Sumangala, B. Nageshwar Rao, Thirumurthy

    In this paper, an attempt has been made to study the slot discharge pattern occurring in the stator coils at various frequencies and maintained at different surface temperature. Epoxy-mica based stator coils were used in the present study. Slot discharges were simulated in stator coils by partially removing semi conducting tape from the insulation surface and clamping a steel flat over the exposed insulation, which acts as stator core. Partial discharge measurements were carried out on 6.6 kV stator coils with simulated slot discharges. The Phase Resolved Partial Discharge pattern of slot discharge and the variation in the slot discharge characteristics due to increase in surface temperature of the stator coil is compared at different frequencies. The partial discharge characteristics and Phase Resolved Partial Discharge pattern were found dependent on excitation voltage frequency. The results are summarized and discussed in this paper.


  • Study of corona with and without barrier at 0.1 Hz and 50 Hz frequency sinusoidal voltage excitation

    by Ramesh P. Nair, B. Nageshwar Rao, B. V. Sumangala

    Partial Discharge (PD) measurement is a very important tool for insulation diagnosis of High Voltage (HV) equipment. The interpretation of PD data is very challenging and has ability to diagnose incipient faults in HV equipment. PD measurement at normal operating power frequency (50/60 Hz) is being carried out for decades and the data interpretation is widely established. At present there is a need of PD measurement to be performed at different frequency of excitation voltage such as Very Low Frequency (0.01-0.1) Hz. But the data interpretation and diagnosis becomes challenging because of limited available studies. In this paper, an attempt is made to compare the corona characteristics, with and without insulation barrier, at Very Low Frequency (0.1Hz) and normal operating power frequency (50 Hz). The corona characteristics used for comparison include average charge magnitude, inception voltage and Phase Resolved Partial Discharge (PRPD) pattern.