Eric Vazquez Jauregui
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Research Interests
Eric Vazquez Jauregui has a total of 1000 co-authors. Here are the top co-authors by number of shared publications:
I. Lawson
Laurentian University
18 shared publicationsE. Behnke
Indiana University South Bend
15 shared publicationsI. Levine
Indiana University South Bend
15 shared publicationsP. S. Cooper
Fermi National Accelerator Laboratory
15 shared publicationsC. B. Krauss
University of Alberta
14 shared publicationsM. Crisler
Fermi National Accelerator Laboratory
14 shared publications
Latest Publications
- Open Access
- 6 November 2026
- Published by American Physical Society (APS) in Physical Review D
- Vol. 114 (9)
Background of the BULLKID detector array operated with a moderate shield on the surface
We present the operation with moderate radiation shield in a surface laboratory of BULky and Low-threshold Kinetic Inductance Detector) (BULLKID), a cryogenic detector for searches of light dark matter or coherent elastic neutrino-nucleus scattering. The detector consists of an array of 60 cubic silicon particle absorbers of 0.34 g each, sensed by cryogenic kinetic inductance detectors. The analysis presented focuses on data from 15 elements of the array, with two central units used to evaluate the background and with their surrounding elements used as veto. The low energy spectrum resulting from an exposure of 290 hours to ambient backgrounds, acquired with the use of external and internal radiation shields, is compatible with the simulations at the level of ( 6.8 ± 0.4 stat . ± 0.1 syst . ) × 10 4 counts / keV kg days from 2 keV down to an energy of 600 eV. The region between 225 eV and 600 eV shows a rise in background in disagreement with the simulations, while not sharing some of the key traits of the low energy excess observed in other cryogenic experiments. The high energy spectrum shape is in overall agreement with the simulations and displays the typical particle-induced x-ray emission of the surrounding lead.
- 6 November 2026
- Published by American Physical Society (APS) in Physical Review D
- Vol. 114 (9)
Open AccessBackground of the BULLKID detector array operated with a moderate shield on the surface
We present the operation with moderate radiation shield in a surface laboratory of BULky and Low-threshold Kinetic Inductance Detector) (BULLKID), a cryogenic detector for searches of light dark matter or coherent elastic neutrino-nucleus scattering. The detector consists of an array of 60 cubic silicon particle absorbers of 0.34 g each, sensed by cryogenic kinetic inductance detectors. The analysis presented focuses on data from 15 elements of the array, with two central units used to evaluate the background and with their surrounding elements used as veto. The low energy spectrum resulting from an exposure of 290 hours to ambient backgrounds, acquired with the use of external and internal radiation shields, is compatible with the simulations at the level of ( 6.8 ± 0.4 stat . ± 0.1 syst . ) × 10 4 counts / keV kg days from 2 keV down to an energy of 600 eV. The region between 225 eV and 600 eV shows a rise in background in disagreement with the simulations, while not sharing some of the key traits of the low energy excess observed in other cryogenic experiments. The high energy spectrum shape is in overall agreement with the simulations and displays the typical particle-induced x-ray emission of the surrounding lead.
- Open Access
- 11 June 2026
- Published by American Physical Society (APS) in Physical Review D
- Vol. 113 (11)
Constraints on light sterile neutrinos and scalar nonstandard interactions using the first reactor antineutrino oscillation results at JUNO
Constraints on light sterile neutrinos and scalar nonstandard neutrino interactions are obtained from the first reactor antineutrino results reported by JUNO. The analysis is based on a spectral χ 2 fit to the prompt-energy distribution corresponding to 59.1 days of data, including full three-flavor oscillations extended to a 3 + 1 framework and effective scalar nonstandard neutrino interaction (NSI) contributions. The reactor flux is modeled using the Daya Bay measured spectrum, and systematic uncertainties are accounted for through a set of nuisance parameters describing reactor flux normalization, spectral shape, background normalization, and detector response. It is found that JUNO is already sensitive to light sterile neutrinos in the mass-splitting range 10 − 5 ≲ Δ m 41 2 / eV 2 ≲ 10 − 2 , probing mixing amplitudes down to sin 2 2 θ 14 ∼ O ( 10 − 1 ) . In addition, a constraint on the scalar NSI parameter | η e e | ∼ O ( 10 − 3 ) is obtained, with correlations with solar oscillation parameters. These results demonstrate the potential of JUNO to probe small deviations from the Standard Model resulting from new physics through precision measurements, with significant improvements expected as statistics and systematic control improve.
- 11 June 2026
- Published by American Physical Society (APS) in Physical Review D
- Vol. 113 (11)
Open AccessConstraints on light sterile neutrinos and scalar nonstandard interactions using the first reactor antineutrino oscillation results at JUNO
Constraints on light sterile neutrinos and scalar nonstandard neutrino interactions are obtained from the first reactor antineutrino results reported by JUNO. The analysis is based on a spectral χ 2 fit to the prompt-energy distribution corresponding to 59.1 days of data, including full three-flavor oscillations extended to a 3 + 1 framework and effective scalar nonstandard neutrino interaction (NSI) contributions. The reactor flux is modeled using the Daya Bay measured spectrum, and systematic uncertainties are accounted for through a set of nuisance parameters describing reactor flux normalization, spectral shape, background normalization, and detector response. It is found that JUNO is already sensitive to light sterile neutrinos in the mass-splitting range 10 − 5 ≲ Δ m 41 2 / eV 2 ≲ 10 − 2 , probing mixing amplitudes down to sin 2 2 θ 14 ∼ O ( 10 − 1 ) . In addition, a constraint on the scalar NSI parameter | η e e | ∼ O ( 10 − 3 ) is obtained, with correlations with solar oscillation parameters. These results demonstrate the potential of JUNO to probe small deviations from the Standard Model resulting from new physics through precision measurements, with significant improvements expected as statistics and systematic control improve.
- Open Access
- 23 March 2026
- Published by Springer Nature in The European Physical Journal C
- Vol. 86 (3)
Energy calibration of bulk events in the BULLKID detector
BULLKID is a cryogenic, solid-state detector designed for direct searches of particle Dark Matter candidates, with mass $$\lesssim 1$$ GeV/c $$^2$$ , and coherent neutrino-nucleus scattering. It is based on an array of dice carved in 5 mm thick silicon crystal, sensed by phonon-mediated Kinetic Inductance Detectors. In previous works, the array was calibrated with bursts of optical photons, which are absorbed in the first hundreds nanometers of the dice and give rise to surface events. In this work, we present the reconstruction of bulk events through the 59.5 keV $$\gamma $$ -ray generated by an $$^{241}$$ Am source, which emulates more closely the interaction of Dark Matter and neutrinos. The peak resolution is $$5\%~(\sigma )$$ and its position is shifted by less than $$10\%$$ with respect to the optical calibration. We observe that the resolution is further improved by a factor 2 combining the signal from neighboring dice. These results confirm the performance of the detector in view of the physics goals of the BULLKID-DM experiment for dark matter search.- 23 March 2026
- Published by Springer Nature in The European Physical Journal C
- Vol. 86 (3)
Open AccessEnergy calibration of bulk events in the BULLKID detector
BULLKID is a cryogenic, solid-state detector designed for direct searches of particle Dark Matter candidates, with mass $$\lesssim 1$$ GeV/c $$^2$$ , and coherent neutrino-nucleus scattering. It is based on an array of dice carved in 5 mm thick silicon crystal, sensed by phonon-mediated Kinetic Inductance Detectors. In previous works, the array was calibrated with bursts of optical photons, which are absorbed in the first hundreds nanometers of the dice and give rise to surface events. In this work, we present the reconstruction of bulk events through the 59.5 keV $$\gamma $$ -ray generated by an $$^{241}$$ Am source, which emulates more closely the interaction of Dark Matter and neutrinos. The peak resolution is $$5\%~(\sigma )$$ and its position is shifted by less than $$10\%$$ with respect to the optical calibration. We observe that the resolution is further improved by a factor 2 combining the signal from neighboring dice. These results confirm the performance of the detector in view of the physics goals of the BULLKID-DM experiment for dark matter search. - 17 February 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Applied Superconductivity
- Vol. 36 (6) , 1-7
Developing the Cryogenic Veto for BULLKID-DM Experiment
BULLKID-DM is a cryogenic experiment that will use phonon-sensing Kinetic Inductance Detectors (KIDs) to search for $\leq 1\ \text{GeV}/\text{c}^{2}$ WIMP dark matter particles. The experiment will be conducted in the low background environment of the underground Gran Sasso National Laboratories in Italy. In the experiment's energy region of interest (200 eV - 2 keV), it is crucial to minimise background signals from muons, $\gamma$-rays and neutrons. For this reason, the collaboration is developing a cryogenic anticoincidence detector (veto) composed of high density scintillating crystals read out by KID-based light detectors. We conducted a study to select the optimal veto material. Along with Bismuth Germanate B $_{4}$ G$_{3}$O $_{12}$ (BGO), we have identified Gadolinium Oxyorthosilicate Gd$_{2}$ SiO$_{5}$ (GSO) and Gadolinium Aluminum Gallium Garnet Gd $_{3}$ Al$_{2}$Ga $_{3}$ O$_{12}$ (GAGG), which contain Gadolinium and thus are ideal for absorption of thermal neutrons. We tested the scintillating properties of the three crystals at cryogenic temperatures down to 20 K. GAGG exhibited the highest light yield and sub-microsecond scintillation times. Furthermore, we validated the effectiveness of the veto through simulation of the backgrounds originating from photon and neutron fluxes in the full BULLKID-DM experimental setup. A benchmark detector composed of a large (3x3 inch cylinder) BGO crystal coupled to a Si wafer equipped with with a KID was tested. We successfully operated this device by measuring the energy spectrum of a $^{137}$Cs gamma source. We then estimated the light yield, energy resolution, and expected energy threshold. We interpreted the results with a simulation that takes into account crystal scintillation, optical photon transport, and KID response. Our finding allow for the optimization of the coupling between a KID and a scintillating crystal to further enhance the detection performance of the BULLKID-DM veto.
- 17 February 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Applied Superconductivity
- Vol. 36 (6) , 1-7
Developing the Cryogenic Veto for BULLKID-DM Experiment
BULLKID-DM is a cryogenic experiment that will use phonon-sensing Kinetic Inductance Detectors (KIDs) to search for $\leq 1\ \text{GeV}/\text{c}^{2}$ WIMP dark matter particles. The experiment will be conducted in the low background environment of the underground Gran Sasso National Laboratories in Italy. In the experiment's energy region of interest (200 eV - 2 keV), it is crucial to minimise background signals from muons, $\gamma$-rays and neutrons. For this reason, the collaboration is developing a cryogenic anticoincidence detector (veto) composed of high density scintillating crystals read out by KID-based light detectors. We conducted a study to select the optimal veto material. Along with Bismuth Germanate B $_{4}$ G$_{3}$O $_{12}$ (BGO), we have identified Gadolinium Oxyorthosilicate Gd$_{2}$ SiO$_{5}$ (GSO) and Gadolinium Aluminum Gallium Garnet Gd $_{3}$ Al$_{2}$Ga $_{3}$ O$_{12}$ (GAGG), which contain Gadolinium and thus are ideal for absorption of thermal neutrons. We tested the scintillating properties of the three crystals at cryogenic temperatures down to 20 K. GAGG exhibited the highest light yield and sub-microsecond scintillation times. Furthermore, we validated the effectiveness of the veto through simulation of the backgrounds originating from photon and neutron fluxes in the full BULLKID-DM experimental setup. A benchmark detector composed of a large (3x3 inch cylinder) BGO crystal coupled to a Si wafer equipped with with a KID was tested. We successfully operated this device by measuring the energy spectrum of a $^{137}$Cs gamma source. We then estimated the light yield, energy resolution, and expected energy threshold. We interpreted the results with a simulation that takes into account crystal scintillation, optical photon transport, and KID response. Our finding allow for the optimization of the coupling between a KID and a scintillating crystal to further enhance the detection performance of the BULLKID-DM veto.
- 9 February 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Applied Superconductivity
- Vol. 36 (6) , 1-7
Real-Time Readout System Design for the BULLKID-DM Experiment: Enhancing Dark Matter Search Capabilities
The BULLKID-DM experiment aims to detect WIMP-like potential Dark Matter particles with masses below 1 GeV/c$^{2}$. Sensing these particles is challenging, as it requires nuclear recoil detectors characterized by high exposure and an energy threshold in the order of 100 eV, achieved with cryogenic phonon detectors. BULLKID-DM introduces a detector that combines the low energy threshold with a new scalable technology, reaching a total target mass of 800 g. The core detector of the BULLKID-DM experiment is composed of 16 100mm silicon wafers, each segmented in 145 dice for a total of more than 2000 units, each sensed by a Microwave Kinetic Inductance Detector (MKID). The MKIDs on each wafer are coupled to a single transmission line and read using a frequency division multiplexing approach by the room-temperature data acquisition. In this contribution, we describe and assess the design of the room-temperature readout electronics system, including the selected hardware components and the FPGA firmware which contains the real-time signal processing stages for tone generation, frequency demultiplexing, and event triggering. We evaluate the system on the ZCU216 board, a commercial evaluation card built around a Radio-Frequency System-on-Chip (RFSoC) with integrated high-speed DACs and ADCs, and connected it to a custom-designed analog front-end for signal conditioning.
- 9 February 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Applied Superconductivity
- Vol. 36 (6) , 1-7
Real-Time Readout System Design for the BULLKID-DM Experiment: Enhancing Dark Matter Search Capabilities
The BULLKID-DM experiment aims to detect WIMP-like potential Dark Matter particles with masses below 1 GeV/c$^{2}$. Sensing these particles is challenging, as it requires nuclear recoil detectors characterized by high exposure and an energy threshold in the order of 100 eV, achieved with cryogenic phonon detectors. BULLKID-DM introduces a detector that combines the low energy threshold with a new scalable technology, reaching a total target mass of 800 g. The core detector of the BULLKID-DM experiment is composed of 16 100mm silicon wafers, each segmented in 145 dice for a total of more than 2000 units, each sensed by a Microwave Kinetic Inductance Detector (MKID). The MKIDs on each wafer are coupled to a single transmission line and read using a frequency division multiplexing approach by the room-temperature data acquisition. In this contribution, we describe and assess the design of the room-temperature readout electronics system, including the selected hardware components and the FPGA firmware which contains the real-time signal processing stages for tone generation, frequency demultiplexing, and event triggering. We evaluate the system on the ZCU216 board, a commercial evaluation card built around a Radio-Frequency System-on-Chip (RFSoC) with integrated high-speed DACs and ADCs, and connected it to a custom-designed analog front-end for signal conditioning.
- 1 July 2025
- Published by American Physical Society (APS) in Physical Review Letters
- Vol. 135 (1) , 011001
Absorption of Fermionic Dark Matter in the PICO-60 C 3 F 8 Bubble Chamber
Fermionic dark matter absorption on nuclear targets via neutral current interactions is explored using a nonrelativistic effective field theory framework. An analysis of data from the PICO-60 C_{3}F_{8} bubble chamber sets leading constraints on spin-independent absorption for dark matter masses below 23 MeV/c^{2} and establishes the first limits on spin-dependent absorptive interactions. These results demonstrate the sensitivity of bubble chambers to low-mass dark matter and underscore the importance of absorption searches in expanding the parameter space of direct detection experiments.
- 1 July 2025
- Published by American Physical Society (APS) in Physical Review Letters
- Vol. 135 (1) , 011001
Absorption of Fermionic Dark Matter in the PICO-60 C 3 F 8 Bubble Chamber
Fermionic dark matter absorption on nuclear targets via neutral current interactions is explored using a nonrelativistic effective field theory framework. An analysis of data from the PICO-60 C_{3}F_{8} bubble chamber sets leading constraints on spin-independent absorption for dark matter masses below 23 MeV/c^{2} and establishes the first limits on spin-dependent absorptive interactions. These results demonstrate the sensitivity of bubble chambers to low-mass dark matter and underscore the importance of absorption searches in expanding the parameter space of direct detection experiments.
- Open Access
- 6 March 2025
- Published by American Physical Society (APS) in Physical Review D
- Vol. 111 (5)
Exploring the standard model and beyond from the evidence of with reactor antineutrinos inThe observation of the coherent elastic neutrino-nucleus scattering process using reactor antineutrinos offers a unique opportunity to probe the Standard Model and explore beyond the Standard Model scenarios. This study reports on the latest results from the CONUS + experiment conducted at the Leibstadt nuclear power plant in Switzerland. The CONUS collaboration reports 395 ± 106 events detected from reactor antineutrinos with an exposure of 327 kg · days , utilizing high-purity germanium detectors operated at sub-keV thresholds. A χ 2 -based statistical analysis was performed on these results, incorporating systematic uncertainties. This analysis was used to extract the weak mixing angle, establish a limit on the neutrino magnetic moment, and impose constraints on neutrino nonstandard interactions using reactor antineutrinos. The results confirm the potential of coherent elastic neutrino-nucleus scattering experiments in the study of fundamental neutrino properties and probing new physics.
- 6 March 2025
- Published by American Physical Society (APS) in Physical Review D
- Vol. 111 (5)
Open AccessExploring the standard model and beyond from the evidence of with reactor antineutrinos inThe observation of the coherent elastic neutrino-nucleus scattering process using reactor antineutrinos offers a unique opportunity to probe the Standard Model and explore beyond the Standard Model scenarios. This study reports on the latest results from the CONUS + experiment conducted at the Leibstadt nuclear power plant in Switzerland. The CONUS collaboration reports 395 ± 106 events detected from reactor antineutrinos with an exposure of 327 kg · days , utilizing high-purity germanium detectors operated at sub-keV thresholds. A χ 2 -based statistical analysis was performed on these results, incorporating systematic uncertainties. This analysis was used to extract the weak mixing angle, establish a limit on the neutrino magnetic moment, and impose constraints on neutrino nonstandard interactions using reactor antineutrinos. The results confirm the potential of coherent elastic neutrino-nucleus scattering experiments in the study of fundamental neutrino properties and probing new physics.
- Open Access
Correction: Golovko et al. Ambient Dose and Dose Rate Measurement in SNOLAB Underground Laboratory at Sudbury, Ontario, Canada. Sensors 2023, 23, 1945
We have found a discrepancy in the reported exposure time for passive sensors, specifically TLDs, in the original manuscript entitled “Ambient Dose and Dose Rate Measurement in SNOLAB Underground Laboratory at Sudbury, Ontario, Canada”
Open AccessCorrection: Golovko et al. Ambient Dose and Dose Rate Measurement in SNOLAB Underground Laboratory at Sudbury, Ontario, Canada. Sensors 2023, 23, 1945
We have found a discrepancy in the reported exposure time for passive sensors, specifically TLDs, in the original manuscript entitled “Ambient Dose and Dose Rate Measurement in SNOLAB Underground Laboratory at Sudbury, Ontario, Canada”
- Open Access
- 1 November 2023
- Published by Sociedad Mexicana de Fisica A C in Revista Mexicana de Física
- Vol. 69 (6 Nov-Dec)
Natural radioactivity concentration measurements in shrimp and sea bass samples from the Mexican Pacific Ocean and the Gulf of Mexico
The radioactivity concentration for shrimp and sea bass retrieved from the Mexican Pacific Ocean and the Gulf of Mexico is reported in this work. The activity of 40K and 208Tl was determined with gamma spectroscopy using a High Purity Germanium detector. Overall, the radioactivity concentration of samples from the Mexican Pacific Ocean is higher than from the Gulf of Mexico. The 40K concentration measured for shrimp is 575 ± 14 Bq/kg (Pacific) and 443 ± 10 Bq/kg (Gulf), while the activity for sea bass is 753 ± 18 Bq/kg (Pacific) and 502 ± 14 Bq/kg (Gulf). Similarly, the measured concentration of 208Tl for shrimp and sea bass is 0.75 ± 0.03 and 1.09 ± 0.05 Bq/kg (Pacific), respectively, and 0.51 ± 0.02 and 0.85 ± 0.04 Bq/kg (Gulf), respectively. No other natural radionuclides or radiation contaminants were observed with significant activity. This is the first comparison of radioactivity concentration in fish and shellfish between the two main Mexican marine ecosystems.
- 1 November 2023
- Published by Sociedad Mexicana de Fisica A C in Revista Mexicana de Física
- Vol. 69 (6 Nov-Dec)
Open AccessNatural radioactivity concentration measurements in shrimp and sea bass samples from the Mexican Pacific Ocean and the Gulf of Mexico
The radioactivity concentration for shrimp and sea bass retrieved from the Mexican Pacific Ocean and the Gulf of Mexico is reported in this work. The activity of 40K and 208Tl was determined with gamma spectroscopy using a High Purity Germanium detector. Overall, the radioactivity concentration of samples from the Mexican Pacific Ocean is higher than from the Gulf of Mexico. The 40K concentration measured for shrimp is 575 ± 14 Bq/kg (Pacific) and 443 ± 10 Bq/kg (Gulf), while the activity for sea bass is 753 ± 18 Bq/kg (Pacific) and 502 ± 14 Bq/kg (Gulf). Similarly, the measured concentration of 208Tl for shrimp and sea bass is 0.75 ± 0.03 and 1.09 ± 0.05 Bq/kg (Pacific), respectively, and 0.51 ± 0.02 and 0.85 ± 0.04 Bq/kg (Gulf), respectively. No other natural radionuclides or radiation contaminants were observed with significant activity. This is the first comparison of radioactivity concentration in fish and shellfish between the two main Mexican marine ecosystems.
- 5 September 2023
- Published by American Physical Society (APS) in Physical Review D
- Vol. 108 (6) , 062003
Search for inelastic dark matter-nucleus scattering with the PICO-60 and bubble chambersPICO bubble chambers have exceptional sensitivity to inelastic dark matter-nucleus interactions due to a combination of their extended nuclear-recoil energy detection window from a few keV to or more and the use of iodine as a heavy target. Inelastic dark matter-nucleus scattering is interesting for studying the properties of dark matter, where many theoretical scenarios have been developed. This study reports the results of a search for dark matter inelastic scattering with the PICO-60 bubble chambers. The analysis reported here comprises physics runs from PICO-60 bubble chambers using and . The run consisted of 36.8 kg of reaching an exposure of operating at thermodynamic thresholds between 7 and 20 keV. The runs consisted of 52 kg of reaching exposures of 1404 and running at thermodynamic thresholds of 2.45 and 3.29 keV, respectively. The analysis disfavors various scenarios, in a wide region of parameter space, that provide a feasible explanation of the signal observed by the DAMA experiment, assuming an inelastic interaction, considering that the PICO bubble chamber used iodine as the target material.- 5 September 2023
- Published by American Physical Society (APS) in Physical Review D
- Vol. 108 (6) , 062003
Search for inelastic dark matter-nucleus scattering with the PICO-60 and bubble chambersPICO bubble chambers have exceptional sensitivity to inelastic dark matter-nucleus interactions due to a combination of their extended nuclear-recoil energy detection window from a few keV to or more and the use of iodine as a heavy target. Inelastic dark matter-nucleus scattering is interesting for studying the properties of dark matter, where many theoretical scenarios have been developed. This study reports the results of a search for dark matter inelastic scattering with the PICO-60 bubble chambers. The analysis reported here comprises physics runs from PICO-60 bubble chambers using and . The run consisted of 36.8 kg of reaching an exposure of operating at thermodynamic thresholds between 7 and 20 keV. The runs consisted of 52 kg of reaching exposures of 1404 and running at thermodynamic thresholds of 2.45 and 3.29 keV, respectively. The analysis disfavors various scenarios, in a wide region of parameter space, that provide a feasible explanation of the signal observed by the DAMA experiment, assuming an inelastic interaction, considering that the PICO bubble chamber used iodine as the target material.