Greeshma Agasthya
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Research Interests
Greeshma Agasthya has a total of 95 co-authors. Here are the top co-authors by number of shared publications:
- Anuj J. Kapadia
Oak Ridge National Laboratory
25 shared publications - Ehsan Samei
Center for Virtual Imaging Trials, Carl E. Ravin Advanced Imaging Laboratories, Department of Radiology, Duke University School of Medicine, 2424 Erwin Rd, Hock Plaza, Ste 302, Durham, NC 27705
9 shared publications Brian P. Harrawood
5 shared publications- Jainil P. Shah
Siemens Healthineers, Cary, NC 27561, USA
5 shared publications Gregory M. Sturgeon
Duke University, Carl E. Ravin Advanced Imaging Laboratories, Department of Radiology, Durham, North Carolina, United States
4 shared publicationsManu N. Lakshmanan
4 shared publications
Latest Publications
- Open Access
- 13 May 2026
- Published by IOP Publishing in Physics in Medicine & Biology
- Vol. 71 (10)
Efficient cell-by-cell simulation of DNA double strand breaks, chromosome aberrations, and cell survival for low- and high-LET radiation particles using TOPAS-nBio and MEDRAS
The increasing sophistication of Monte Carlo (MC)-based simulations, such as TOPAS-nBio for radiation track structure and DNA damage, and MEDRAS-MC for subsequent DNA repair and cell survival, has ushered in an era of in-silico single-cell radiobiology. However, these simulations remain computationally prohibitive. In this study, we introduce a novel method that significantly accelerates the integrated simulation process for in-silico single-cell radiobiology. Our approach centers on pre-calculating and constructing a single-particle-track (SPT) standard DNA damage (SDD) data library using TOPAS-nBio. Each SPT-SDD data entry in this library records the positions of various DNA damage types (e.g., base damage, single-strand breaks, and double-strand breaks) produced by a single particle track. The comprehensive library contains a massive amount of SPT-SDD data entries, covering a broad range of particle energies. This data library functions as a look-up table, allowing for rapid assembly of DNA damage data for any desired dose level. This is achieved by randomly fetching and superimposing many SPT-SDD data entries from the pre-calculated library. The resulting “composite” SDD data file then serves as input for MEDRAS-MC to simulate and compute DNA damage outcomes, including chromosome aberrations and cell lethality for each individual cell. Furthermore, "timestamps" can be added to the superimposed data to account for dose rate effects. This work presents the first integrated Monte Carlo framework that bridges track-structure simulation (TOPAS-nBio) with mechanistic repair-misrepair modeling (MEDRAS-MC) to predict chromosome aberrations and cell lethality on a cell-by-cell basis. In this paper, we first describe this novel methodology and then apply it to compute radiation-induced outcomes for three previously reported in vitro experiments. These applications involve 280-kVp X-rays, protons, and alpha particles, covering a broad spectrum of linear energy transfer (LET). Finally, we compare our in silico results with experimental data and provide a detailed discussion of any observed discrepancies.
- 13 May 2026
- Published by IOP Publishing in Physics in Medicine & Biology
- Vol. 71 (10)
Open AccessEfficient cell-by-cell simulation of DNA double strand breaks, chromosome aberrations, and cell survival for low- and high-LET radiation particles using TOPAS-nBio and MEDRAS
The increasing sophistication of Monte Carlo (MC)-based simulations, such as TOPAS-nBio for radiation track structure and DNA damage, and MEDRAS-MC for subsequent DNA repair and cell survival, has ushered in an era of in-silico single-cell radiobiology. However, these simulations remain computationally prohibitive. In this study, we introduce a novel method that significantly accelerates the integrated simulation process for in-silico single-cell radiobiology. Our approach centers on pre-calculating and constructing a single-particle-track (SPT) standard DNA damage (SDD) data library using TOPAS-nBio. Each SPT-SDD data entry in this library records the positions of various DNA damage types (e.g., base damage, single-strand breaks, and double-strand breaks) produced by a single particle track. The comprehensive library contains a massive amount of SPT-SDD data entries, covering a broad range of particle energies. This data library functions as a look-up table, allowing for rapid assembly of DNA damage data for any desired dose level. This is achieved by randomly fetching and superimposing many SPT-SDD data entries from the pre-calculated library. The resulting “composite” SDD data file then serves as input for MEDRAS-MC to simulate and compute DNA damage outcomes, including chromosome aberrations and cell lethality for each individual cell. Furthermore, "timestamps" can be added to the superimposed data to account for dose rate effects. This work presents the first integrated Monte Carlo framework that bridges track-structure simulation (TOPAS-nBio) with mechanistic repair-misrepair modeling (MEDRAS-MC) to predict chromosome aberrations and cell lethality on a cell-by-cell basis. In this paper, we first describe this novel methodology and then apply it to compute radiation-induced outcomes for three previously reported in vitro experiments. These applications involve 280-kVp X-rays, protons, and alpha particles, covering a broad spectrum of linear energy transfer (LET). Finally, we compare our in silico results with experimental data and provide a detailed discussion of any observed discrepancies.
- Open Access
- 12 May 2026
- Published by Public Library of Science (PLoS) in PLOS ONE
- Vol. 21 (5) , e0324673
Comparing machine and deep learning models for pediatric anxiety classification using structured EHRs and area-based measures of health data
Objective: This retrospective, case-control study with internal validation evaluates the performance of machine learning (ML) and deep learning (DL) models in classifying pediatric patients at risk for anxiety disorders using structured electronic health records (EHRs) and area-based measures of health (ABMH). The aim is to enable proactive care by monitoring potential anxiety onset across developmental stages. Methods: We trained a series of ML models (Logistic Regression, Decision Tree, Random Forest, K-Nearest Neighbors, XGBoost) and DL models (LSTM, GRU, RETAIN, Dipole) using structured EHR data from 30-day windows prior to diagnosis. Two datasets were used per age group: one with structured EHR data only, and another including both EHR and ABMH data. ML models were trained using short-term cross-sectional features, while DL models leveraged full longitudinal patient histories. Performance was assessed using AUROC, AUPRC, PPV, NPV, F1 score, and accuracy. Due to differences in input scope, model performance reflects both algorithmic and temporal design differences and is not intended as a direct comparison between ML and DL. Results: ML models offered strong baseline performance, with XGBoost achieving AUROC scores of 0.817 (EHR) and 0.816 (EHR+ABMH) for 8-year-olds. Adding ABMH features did not significantly improve performance. DL models, particularly RETAIN and Dipole, achieved the highest AUROC values (e.g., Dipole: 0.853 with EHR, 0.857 with EHR+ABMH for 8-year-olds), outperforming other DL and ML models within their respective design constraints. Conclusion: Both ML and DL models successfully identified likely anxiety onset using structured EHR data. DL models using longitudinal data achieved the highest performance, while XGBoost provided a robust ML baseline. The minimal impact of ABMH features highlights integration challenges, and performance variation across ages emphasizes the need for age-stratified modeling approaches.
- 12 May 2026
- Published by Public Library of Science (PLoS) in PLOS ONE
- Vol. 21 (5) , e0324673
Open AccessComparing machine and deep learning models for pediatric anxiety classification using structured EHRs and area-based measures of health data
Objective: This retrospective, case-control study with internal validation evaluates the performance of machine learning (ML) and deep learning (DL) models in classifying pediatric patients at risk for anxiety disorders using structured electronic health records (EHRs) and area-based measures of health (ABMH). The aim is to enable proactive care by monitoring potential anxiety onset across developmental stages. Methods: We trained a series of ML models (Logistic Regression, Decision Tree, Random Forest, K-Nearest Neighbors, XGBoost) and DL models (LSTM, GRU, RETAIN, Dipole) using structured EHR data from 30-day windows prior to diagnosis. Two datasets were used per age group: one with structured EHR data only, and another including both EHR and ABMH data. ML models were trained using short-term cross-sectional features, while DL models leveraged full longitudinal patient histories. Performance was assessed using AUROC, AUPRC, PPV, NPV, F1 score, and accuracy. Due to differences in input scope, model performance reflects both algorithmic and temporal design differences and is not intended as a direct comparison between ML and DL. Results: ML models offered strong baseline performance, with XGBoost achieving AUROC scores of 0.817 (EHR) and 0.816 (EHR+ABMH) for 8-year-olds. Adding ABMH features did not significantly improve performance. DL models, particularly RETAIN and Dipole, achieved the highest AUROC values (e.g., Dipole: 0.853 with EHR, 0.857 with EHR+ABMH for 8-year-olds), outperforming other DL and ML models within their respective design constraints. Conclusion: Both ML and DL models successfully identified likely anxiety onset using structured EHR data. DL models using longitudinal data achieved the highest performance, while XGBoost provided a robust ML baseline. The minimal impact of ABMH features highlights integration challenges, and performance variation across ages emphasizes the need for age-stratified modeling approaches.
- Open Access
Comparing Machine and Deep Learning Models for Pediatric Anxiety Classification using Structured EHRs and Area-based Measures of Health Data
Objective: This study investigates the performance of various machine learning (ML) and deep learning (DL) models to classify pediatric patients at risk of anxiety disorders using electronic health records (EHRs). By leveraging EHR data and including Area-based measures of health (ABMH) data, this approach aims to enable proactive care by monitoring potential anxiety onset comprehensively across various age groups. Methods: In this study, we trained a series of ML and DL models to classify youth at risk of developing anxiety disorders. ML models (Logistic Regression, Decision Tree, Random Forest, K-Nearest Neighbors, XGBoost) and DL models (LSTM, GRU, RETAIN, Dipole) were trained using structured EHR data from 30-day periods before anxiety diagnoses. Two datasets per age group were used: one with structured EHR data only and another with incorporating both structured EHR and ABMH data. Model performance was assessed using accuracy, the AUROC, AUPRC, PPV, NPV, and F1 scores. Results: The ML models provided a solid performance baseline, with XGBoost showing strong baseline performance across age groups, with AUROC scores of 0.817 (structured EHR) and 0.816 (structured EHR + ABMH). Between DL models, RETAIN and Dipole performed the best. For example, RETAIN achieved AUROC scores of 0.851 (structured EHR) and 0.853 (structured + ABMH), while Dipole scored 0.853 and 0.857, respectively, for 8-year-olds. These results underscore the viability of both ML and DL models for the early detection of pediatric anxiety disorders. Conclusion: This study comprehensively investigated ML and DL models for diagnosing pediatric anxiety. We demonstrated that ML and DL models can effectively monitor probable anxiety onset within an EHR system and also with the ABMH data. We discovered that model performance varied with age, indicating the need for personalized model development per age group for effective clinical predictive analytics.
Open AccessComparing Machine and Deep Learning Models for Pediatric Anxiety Classification using Structured EHRs and Area-based Measures of Health Data
Objective: This study investigates the performance of various machine learning (ML) and deep learning (DL) models to classify pediatric patients at risk of anxiety disorders using electronic health records (EHRs). By leveraging EHR data and including Area-based measures of health (ABMH) data, this approach aims to enable proactive care by monitoring potential anxiety onset comprehensively across various age groups. Methods: In this study, we trained a series of ML and DL models to classify youth at risk of developing anxiety disorders. ML models (Logistic Regression, Decision Tree, Random Forest, K-Nearest Neighbors, XGBoost) and DL models (LSTM, GRU, RETAIN, Dipole) were trained using structured EHR data from 30-day periods before anxiety diagnoses. Two datasets per age group were used: one with structured EHR data only and another with incorporating both structured EHR and ABMH data. Model performance was assessed using accuracy, the AUROC, AUPRC, PPV, NPV, and F1 scores. Results: The ML models provided a solid performance baseline, with XGBoost showing strong baseline performance across age groups, with AUROC scores of 0.817 (structured EHR) and 0.816 (structured EHR + ABMH). Between DL models, RETAIN and Dipole performed the best. For example, RETAIN achieved AUROC scores of 0.851 (structured EHR) and 0.853 (structured + ABMH), while Dipole scored 0.853 and 0.857, respectively, for 8-year-olds. These results underscore the viability of both ML and DL models for the early detection of pediatric anxiety disorders. Conclusion: This study comprehensively investigated ML and DL models for diagnosing pediatric anxiety. We demonstrated that ML and DL models can effectively monitor probable anxiety onset within an EHR system and also with the ABMH data. We discovered that model performance varied with age, indicating the need for personalized model development per age group for effective clinical predictive analytics.
- Open Access
Temporal Drift in the Semantic Meaning of Pediatric Anxiety Terms in Electronic Healthcare Records
: Objective: To identify and measure semantic drift (i.e., the change in semantic meaning over time) in expert-provided anxiety-related (AR) terminology and compare it to other common electronic health record (EHR) vocabulary in longitudinal clinical notes. Methods: Computational methods were used to investigate semantic drift in a pediatric clinical note corpus from 2009 to 2022. First, we measured the semantic drift of a word using the similarity of temporal word embeddings. Second, we analyzed how a word’s contextual meaning evolved over successive years by examining its nearest neighbors. Third, we investigated the Laws of Semantic Change to measure frequency and polysemy. Words were categorized as AR or common EHR vocabulary. Results: 98% of the AR terminology maintained a cosine similarity score of 0.00 – 0.50; at least 90% of common EHR vocabulary maintained a cosine similarity score of 0.00 – 0.25. Laws of Semantic Change indicated that frequently occurring vocabulary words remained contextually stable (Frequency Coefficient = 0.04); however, words with multiple meanings, such as abbreviations, did not show the same stability (Polysemy Coefficient = 0.630). The semantic change over time within the AR terminology was slower on average than the semantic change within the common EHR vocabulary (Type Coefficient = -0.179); this was further validated by interacting the year and Type (Coef = -0.09 – -0.523). Conclusions: The semantic meaning of anxiety terms remains stable within our dataset, indicating slower overall semantic drift compared to common EHR vocabulary. However, failure to capture nuanced changes may impact the accuracy and reliability of clinical decision support systems over time.
Open AccessTemporal Drift in the Semantic Meaning of Pediatric Anxiety Terms in Electronic Healthcare Records
: Objective: To identify and measure semantic drift (i.e., the change in semantic meaning over time) in expert-provided anxiety-related (AR) terminology and compare it to other common electronic health record (EHR) vocabulary in longitudinal clinical notes. Methods: Computational methods were used to investigate semantic drift in a pediatric clinical note corpus from 2009 to 2022. First, we measured the semantic drift of a word using the similarity of temporal word embeddings. Second, we analyzed how a word’s contextual meaning evolved over successive years by examining its nearest neighbors. Third, we investigated the Laws of Semantic Change to measure frequency and polysemy. Words were categorized as AR or common EHR vocabulary. Results: 98% of the AR terminology maintained a cosine similarity score of 0.00 – 0.50; at least 90% of common EHR vocabulary maintained a cosine similarity score of 0.00 – 0.25. Laws of Semantic Change indicated that frequently occurring vocabulary words remained contextually stable (Frequency Coefficient = 0.04); however, words with multiple meanings, such as abbreviations, did not show the same stability (Polysemy Coefficient = 0.630). The semantic change over time within the AR terminology was slower on average than the semantic change within the common EHR vocabulary (Type Coefficient = -0.179); this was further validated by interacting the year and Type (Coef = -0.09 – -0.523). Conclusions: The semantic meaning of anxiety terms remains stable within our dataset, indicating slower overall semantic drift compared to common EHR vocabulary. However, failure to capture nuanced changes may impact the accuracy and reliability of clinical decision support systems over time.
- Open Access
- 13 December 2024
- Published by IOP Publishing in Physics in Medicine & Biology
- Vol. 69 (24) , 245017
Integrating chromosome conformation and DNA repair in a computational framework to assess cell radiosensitivity*
Objective. The arrangement of chromosomes in the cell nucleus has implications for cell radiosensitivity. The development of new tools to utilize Hi-C chromosome conformation data in nanoscale radiation track structure simulations allows for in silico investigation of this phenomenon. We have developed a framework employing Hi-C-based cell nucleus models in Monte Carlo radiation simulations, in conjunction with mechanistic models of DNA repair, to predict not only the initial radiation-induced DNA damage, but also the repair outcomes resulting from this damage, allowing us to investigate the role chromosome conformation plays in the biological outcome of radiation exposure. Approach. In this study, we used this framework to generate cell nucleus models based on Hi-C data from fibroblast and lymphoblastoid cells and explore the effects of cell type-specific chromosome structure on radiation response. The models were used to simulate external beam irradiation including DNA damage and subsequent DNA repair. The kinetics of the simulated DNA repair were compared with previous results. Main results. We found that the fibroblast models resulted in a higher rate of inter-chromosome misrepair than the lymphoblastoid model, despite having similar amounts of initial DNA damage and total misrepairs for each irradiation scenario. Significance. This framework represents a step forward in radiobiological modeling and simulation allowing for more realistic investigation of radiosensitivity in different types of cells.
- 13 December 2024
- Published by IOP Publishing in Physics in Medicine & Biology
- Vol. 69 (24) , 245017
Open AccessIntegrating chromosome conformation and DNA repair in a computational framework to assess cell radiosensitivity*
Objective. The arrangement of chromosomes in the cell nucleus has implications for cell radiosensitivity. The development of new tools to utilize Hi-C chromosome conformation data in nanoscale radiation track structure simulations allows for in silico investigation of this phenomenon. We have developed a framework employing Hi-C-based cell nucleus models in Monte Carlo radiation simulations, in conjunction with mechanistic models of DNA repair, to predict not only the initial radiation-induced DNA damage, but also the repair outcomes resulting from this damage, allowing us to investigate the role chromosome conformation plays in the biological outcome of radiation exposure. Approach. In this study, we used this framework to generate cell nucleus models based on Hi-C data from fibroblast and lymphoblastoid cells and explore the effects of cell type-specific chromosome structure on radiation response. The models were used to simulate external beam irradiation including DNA damage and subsequent DNA repair. The kinetics of the simulated DNA repair were compared with previous results. Main results. We found that the fibroblast models resulted in a higher rate of inter-chromosome misrepair than the lymphoblastoid model, despite having similar amounts of initial DNA damage and total misrepairs for each irradiation scenario. Significance. This framework represents a step forward in radiobiological modeling and simulation allowing for more realistic investigation of radiosensitivity in different types of cells.
- Open Access
Integrating Chromosome Conformation and DNA Repair in a Computational Framework to Assess Cell Radiosensitivity
Objective: The arrangement of chromosomes in the cell nucleus has implications for cell radiosensitivity. The development of new tools to utilize Hi-C chromosome conformation data in nanoscale radiation track structure simulations allows for in silico investigation of this phenomenon. We have developed a framework employing Hi-C-based cell nucleus models in Monte Carlo radiation simulations, in conjunction with mechanistic models of DNA repair, to predict not only the initial radiation-induced DNA damage, but also the repair outcomes resulting from this damage, allowing us to investigate the role chromosome conformation plays in the biological outcome of radiation exposure. Approach: In this study, we used this framework to generate cell nucleus models based on Hi-C data from fibroblast and lymphoblastoid cells and explore the effects of cell type-specific chromosome structure on radiation response. The models were used to simulate external beam irradiation including DNA damage and subsequent DNA repair. The kinetics of the simulated DNA repair were compared with previous results. Main Results: We found that the fibroblast models resulted in a higher rate of inter-chromosome misrepair than the lymphoblastoid model, despite having similar amounts of initial DNA damage and total misrepairs for each irradiation scenario. Significance: This framework represents a step forward in radiobiological modeling and simulation allowing for more realistic investigation of radiosensitivity in different types of cells.
Open AccessIntegrating Chromosome Conformation and DNA Repair in a Computational Framework to Assess Cell Radiosensitivity
Objective: The arrangement of chromosomes in the cell nucleus has implications for cell radiosensitivity. The development of new tools to utilize Hi-C chromosome conformation data in nanoscale radiation track structure simulations allows for in silico investigation of this phenomenon. We have developed a framework employing Hi-C-based cell nucleus models in Monte Carlo radiation simulations, in conjunction with mechanistic models of DNA repair, to predict not only the initial radiation-induced DNA damage, but also the repair outcomes resulting from this damage, allowing us to investigate the role chromosome conformation plays in the biological outcome of radiation exposure. Approach: In this study, we used this framework to generate cell nucleus models based on Hi-C data from fibroblast and lymphoblastoid cells and explore the effects of cell type-specific chromosome structure on radiation response. The models were used to simulate external beam irradiation including DNA damage and subsequent DNA repair. The kinetics of the simulated DNA repair were compared with previous results. Main Results: We found that the fibroblast models resulted in a higher rate of inter-chromosome misrepair than the lymphoblastoid model, despite having similar amounts of initial DNA damage and total misrepairs for each irradiation scenario. Significance: This framework represents a step forward in radiobiological modeling and simulation allowing for more realistic investigation of radiosensitivity in different types of cells.
- 21 March 2023
- Published by Elsevier in Child and Adolescent Psychiatric Clinics of North America
- Vol. 32 (3) , 511-530
Developmental Epidemiology of Pediatric Anxiety Disorders
- 21 March 2023
- Published by Elsevier in Child and Adolescent Psychiatric Clinics of North America
- Vol. 32 (3) , 511-530
Developmental Epidemiology of Pediatric Anxiety Disorders
- Open Access
- 11 December 2017
- Published by SPIE-Intl Soc Optical Eng in Journal of Medical Imaging
- Vol. 5 (03) , 1-7
Estimability index for volume quantification of homogeneous spherical lesions in computed tomography
Volume of lung nodules is an important biomarker, quantifiable from computed tomography (CT) images. The usefulness of volume quantification, however, depends on the precision of quantification. Experimental assessment of precision is time consuming. A mathematical estimability model was used to assess the quantification precision of CT nodule volumetry in terms of an index (e′), incorporating image noise and resolution, nodule properties, and segmentation software. The noise and resolution were characterized in terms of noise power spectrum and task transfer function. The nodule properties and segmentation algorithm were modeled in terms of a task function and a template function, respectively. The e′ values were benchmarked against experimentally acquired precision values from an anthropomorphic chest phantom across 54 acquisition protocols, 2 nodule sizes, and 2 volume segmentation softwares. e′ exhibited correlation with experimental precision across nodule sizes and acquisition protocols but dependence on segmentation software. Compared to the assessment of empirical precision, which required ∼300 h to perform the segmentation, the e′ method required ∼3 h from data collection to mathematical computation. A mathematical modeling of volume quantification provides efficient prediction of quantitative performance. It establishes a method to verify quantitative compliance and to optimize clinical protocols for chest CT volumetry.
- 11 December 2017
- Published by SPIE-Intl Soc Optical Eng in Journal of Medical Imaging
- Vol. 5 (03) , 1-7
Open AccessEstimability index for volume quantification of homogeneous spherical lesions in computed tomography
Volume of lung nodules is an important biomarker, quantifiable from computed tomography (CT) images. The usefulness of volume quantification, however, depends on the precision of quantification. Experimental assessment of precision is time consuming. A mathematical estimability model was used to assess the quantification precision of CT nodule volumetry in terms of an index (e′), incorporating image noise and resolution, nodule properties, and segmentation software. The noise and resolution were characterized in terms of noise power spectrum and task transfer function. The nodule properties and segmentation algorithm were modeled in terms of a task function and a template function, respectively. The e′ values were benchmarked against experimentally acquired precision values from an anthropomorphic chest phantom across 54 acquisition protocols, 2 nodule sizes, and 2 volume segmentation softwares. e′ exhibited correlation with experimental precision across nodule sizes and acquisition protocols but dependence on segmentation software. Compared to the assessment of empirical precision, which required ∼300 h to perform the segmentation, the e′ method required ∼3 h from data collection to mathematical computation. A mathematical modeling of volume quantification provides efficient prediction of quantitative performance. It establishes a method to verify quantitative compliance and to optimize clinical protocols for chest CT volumetry.
- 1 November 2017
- Published by American Roentgen Ray Society in American Journal of Roentgenology
- Vol. 209 (5) , W322-W332
Can Breast Compression Be Reduced in Digital Mammography and Breast Tomosynthesis?
OBJECTIVE. The objective of this study was to investigate the impact of decreasing breast compression during digital mammography and breast tomosynthesis (DBT) on perceived pain and image quality. MATERIALS AND METHODS. In this two-part study, two groups of women with prior mammograms were recruited. In part 1, subjects were positioned for craniocaudal (CC) and mediolateral oblique (MLO) views, and four levels of compression force were applied to evaluate changes in breast thickness, perceived pain, and relative tissue coverage. No imaging was performed. In part 2, two MLO DBT images of one breast of each patient were acquired at standard and reduced compression. Blurring artifacts and tissue coverage were judged by three breast imaging radiologists, and compression force, breast thickness, relative tissue coverage, and perceived pain were recorded. RESULTS. Only the first reduction in force was feasible because further reduction resulted in inadequate breast immobilization. Mean force reductions of 48% a...
- 1 November 2017
- Published by American Roentgen Ray Society in American Journal of Roentgenology
- Vol. 209 (5) , W322-W332
Can Breast Compression Be Reduced in Digital Mammography and Breast Tomosynthesis?
OBJECTIVE. The objective of this study was to investigate the impact of decreasing breast compression during digital mammography and breast tomosynthesis (DBT) on perceived pain and image quality. MATERIALS AND METHODS. In this two-part study, two groups of women with prior mammograms were recruited. In part 1, subjects were positioned for craniocaudal (CC) and mediolateral oblique (MLO) views, and four levels of compression force were applied to evaluate changes in breast thickness, perceived pain, and relative tissue coverage. No imaging was performed. In part 2, two MLO DBT images of one breast of each patient were acquired at standard and reduced compression. Blurring artifacts and tissue coverage were judged by three breast imaging radiologists, and compression force, breast thickness, relative tissue coverage, and perceived pain were recorded. RESULTS. Only the first reduction in force was feasible because further reduction resulted in inadequate breast immobilization. Mean force reductions of 48% a...
- 7 August 2017
- Published by IOP Publishing in Physics in Medicine & Biology
- Vol. 62 (17) , 6920-6937
The compressed breast during mammography and breast tomosynthesis: in vivo shape characterization and modeling
To characterize and develop a patient-based 3D model of the compressed breast undergoing mammography and breast tomosynthesis. During this IRB-approved, HIPAA-compliant study, 50 women were recruited to undergo 3D breast surface imaging with structured light (SL) during breast compression, along with simultaneous acquisition of a tomosynthesis image. A pair of SL systems were used to acquire 3D surface images by projecting 24 different patterns onto the compressed breast and capturing their reflection off the breast surface in approximately 12–16 s. The 3D surface was characterized and modeled via principal component analysis. The resulting surface model was combined with a previously developed 2D model of projected compressed breast shapes to generate a full 3D model. Data from ten patients were discarded due to technical problems during image acquisition. The maximum breast thickness (found at the chest-wall) had an average value of 56 mm, and decreased 13% towards the nipple (breast tilt angle of 5.2°). The portion of the breast not in contact with the compression paddle or the support table extended on average 17 mm, 18% of the chest-wall to nipple distance. The outermost point along the breast surface lies below the midline of the total thickness. A complete 3D model of compressed breast shapes was created and implemented as a software application available for download, capable of generating new random realistic 3D shapes of breasts undergoing compression. Accurate characterization and modeling of the breast curvature and shape was achieved and will be used for various image processing and clinical tasks.
- 7 August 2017
- Published by IOP Publishing in Physics in Medicine & Biology
- Vol. 62 (17) , 6920-6937
The compressed breast during mammography and breast tomosynthesis: in vivo shape characterization and modeling
To characterize and develop a patient-based 3D model of the compressed breast undergoing mammography and breast tomosynthesis. During this IRB-approved, HIPAA-compliant study, 50 women were recruited to undergo 3D breast surface imaging with structured light (SL) during breast compression, along with simultaneous acquisition of a tomosynthesis image. A pair of SL systems were used to acquire 3D surface images by projecting 24 different patterns onto the compressed breast and capturing their reflection off the breast surface in approximately 12–16 s. The 3D surface was characterized and modeled via principal component analysis. The resulting surface model was combined with a previously developed 2D model of projected compressed breast shapes to generate a full 3D model. Data from ten patients were discarded due to technical problems during image acquisition. The maximum breast thickness (found at the chest-wall) had an average value of 56 mm, and decreased 13% towards the nipple (breast tilt angle of 5.2°). The portion of the breast not in contact with the compression paddle or the support table extended on average 17 mm, 18% of the chest-wall to nipple distance. The outermost point along the breast surface lies below the midline of the total thickness. A complete 3D model of compressed breast shapes was created and implemented as a software application available for download, capable of generating new random realistic 3D shapes of breasts undergoing compression. Accurate characterization and modeling of the breast curvature and shape was achieved and will be used for various image processing and clinical tasks.