Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Eduard Fernandez-Nofrerias has a total of 598 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Prognostic Impact of the Interaction Between Sarcopenia and Aortic Stenosis Hemodynamic Phenotypes

    by Michele Trichilo, Nicola Amelotti, Adele Antonini, Claudia Escabia‐Riera, Elena Ferrer‐Sistach, Victoria Vilalta, Eduard Fernandez‐Nofrerias, Xavier Carrillo‐Suarez, Victoria Delgado

    Background: The hemodynamic phenotype of severe aortic stenosis (AS) is associated with the long‐term outcomes following transcatheter aortic valve implantation (TAVI). Furthermore, sarcopenia has been associated with poor outcomes after TAVI. How the hemodynamic phenotype of severe AS relates to the presence of sarcopenia and how the interaction between both factors relates to all‐cause mortality after TAVI have not been evaluated. Aims: The present study investigated how the combination of sarcopenia and the hemodynamic phenotypes of AS impacts long‐term outcomes in patients undergoing TAVI. Methods: In this single‐center, retrospective study, a cohort of consecutive patients with severe AS who underwent TAVI between 2010 and 2024 with available computed tomography data to analyze the presence of sarcopenia was evaluated. Severe AS was classified into four hemodynamic subtypes according to mean transvalvular gradient, left ventricular ejection fraction (LVEF), and stroke volume index (SVi). Sarcopenia was defined by sex‐specific cut‐offs of psoas muscle area at the L4 level on computed tomography. The primary endpoint was all‐cause mortality. Results: Four hundred and seven patients (median age 82 years [78–85 years] and 38% male) were analyzed. Normal flow‐high gradient was the most frequent severe AS hemodynamic phenotype (74%), followed by classical low flow‐low gradient (13%), paradoxical low flow‐low gradient (7%), and 6% had normal flow‐low gradient. Sarcopenia was present in 42% of the patients, and it was more common among patients with classical low flow‐low gradient severe AS (76%). The interaction between sarcopenia and paradoxical low flow‐low gradient severe AS was independently associated with all‐cause mortality (hazard ratio 2.82; confidence interval 95% 2.54−3.14; p < 0.001). Conclusions: The presence of sarcopenia is not uncommon among patients with severe AS undergoing TAVI and significantly affects outcomes in patients with paradoxical low flow‐low gradient severe AS.

  • Open Access

    Dapagliflozin After Transcatheter Aortic Valve Implantation According to Frailty in DapaTAVI Trial

    by Rafael Gonzalez‐Manzanares, Soledad Ojeda, Ignacio Amat‐Santos, Albert Ariza‐Solé, Rafael Romaguera, Diego López Otero, Luis Nombela‐Franco, Livia Gheorge, Jorge Sanz‐Sánchez, Carlos Baladrón Zorita, et al.

    Background: Frailty is common in patients with severe aortic stenosis undergoing transcatheter aortic valve implantation and portends worse outcomes. Whether the benefit of posttranscatheter aortic valve implantation dapagliflozin differs by frailty is uncertain. Methods: In this post hoc analysis, we investigated the efficacy of dapagliflozin according to frailty status in the DapaTAVI (Dapagliflozin in Patients Undergoing Transcatheter Aortic Valve Implantation) trial. Frailty was assessed through the Fatigue, Resistance, Ambulation, Illnesses, and Loss of Weight scale (robust=0, prefrail=1–2, frail=3–5). The primary outcome was the composite of all‐cause death or worsening heart failure at 1 year. Results: Among 1222 patients with baseline frailty assessment, 47.2% were frail, 40.3% prefrail, and 12.4% robust. Over 12 months, 215 patients (17.6%) experienced the primary end point. Patients who were prefrail and frail had higher risk than robust patients (adjusted hazard ratios [HRs], 1.88 [95% CI, 1.05–3.38] and 2.29 [1.29–4.07], respectively; P =0.004). Dapagliflozin was associated with a lower risk of the primary end point in patients who were frail (HR, 0.53 [95% CI, 0.36–0.77]) but not in those who were prefrail (HR, 1.01 [95% CI, 0.66–1.55]) or robust patients (HR, 1.26 [95% CI, 0.42–3.75]); P for interaction=0.021. There was no evidence that frailty modified the safety profile of dapagliflozin. Conclusions: Frailty was common and independently associated with worse outcomes after transcatheter aortic valve implantation. Dapagliflozin appeared to confer greater relative benefit in patients with frailty.


  • Transcarotid TAVI with left carotid-subclavian bypass for the management of refractory angina

    by Elisabet Berastegui Garcia, Gonzalo Bueno Casanovas, Eduard Fernàndez Nofrerias, Valentina Mescola, Ignasi Julià Amill, Danela Figuereo Beltre

    New transcatheter and endovascular techniques have transformed cardiac surgery operating rooms into collaborative spaces where multidisciplinary teams address complex cases. In the patient we present, surgical revascularization was performed; the patient then developed progressive angina with electrocardiographic changes in the anterior wall. Coronary angiography showed patent grafts and no progression of native coronary artery disease. Computed tomography revealed a calcified plaque at the origin of the left subclavian artery. Endovascular treatment was performed using a covered stent proximal to the mammary artery. Despite this, refractory angina persisted, and further angioplasties were necessary, with no improvement in the vascular lumen. Additionally, echocardiography showed worsening of a preexisting aortic stenosis. A multidisciplinary approach was chosen, involving a left transcarotid self-expanding transcatheter aortic valve implantation (TAVI) and concomitant carotid-subclavian bypass, using an alternative technique to achieve optimal annular alignment via a contralateral support balloon.

  • Tavi transcarótidea con bypass carótido-subclavio izquierdo para el manejo de la angina refractaria

    by Danela Figuereo Beltre, Ignasi Julià Amill, Valentina Mescola, Elisabet Berastegui Garcia, Eduard Fernàndez Nofrerias, Gonzalo Bueno Casanovas

    Las nuevas técnicas transcatéter y endovasculares han convertido los quirófanos de cirugía cardíaca en espacios de encuentro en los que equipos multidisciplinares abordan escenarios complejos. En el paciente que presentamos, se realizó una revascularización quirúrgica; y se constató angina progresiva con cambios electrocardiográficos en la pared anterior. La coronariografía mostró injertos permeables y sin progresión de la enfermedad coronaria nativa. La tomografía computarizada evidenció una placa calcificada en el origen de la arteria subclavia izquierda. Se realizó un tratamiento endovascular con un stent cubierto proximal a la arteria mamaria. A pesar de ello, la angina refractaria persistió y fue necesario realizar nuevas angioplastias, sin mejoría del lumen vascular. Además, el ecocardiograma mostró progresión hacia la gravedad de una estenosis aórtica preexistente. Se optó por un abordaje multidisciplinar con un implante valvular aórtico transcatéter (TAVI, por su sigla en inglés) autoexpandible transcarotídeo izquierdo y bypass carotídeo-subclavio concomitante, utilizando una técnica alternativa para lograr una alineación anular óptima mediante un balón de soporte contralateral.

  • Balloon- Versus Self-Expanding Transcatheter Valves for Failed Small Surgical Aortic Bioprostheses: 3-Year Results of the LYTEN Trial

    by Pedro Cepas-Guillén, Amr E. Abbas, Vicenç Serra, Victoria Vilalta, Luis Nombela-Franco, Ander Regueiro, Karim M. Al-Azizi, Ayman Iskander, Lenard Conradi, Jessica Forcillo, et al.

    BACKGROUND: Data comparing valve systems in the valve-in-valve transcatheter aortic valve replacement (TAVR) field have been obtained from retrospective studies. This prespecified secondary analysis of the LYTEN randomized trial (Comparison of the Balloon-Expandable Edwards Valve and Self-Expandable CoreValve Evolut R or Evolut PRO System for the Treatment of Small, Severely Dysfunctional Surgical Aortic Bioprostheses) aims to compare the 3-year hemodynamic performance and clinical outcomes between balloon-expandable valves (BEV) SAPIEN 3/ULTRA (Edwards Lifesciences) and self-expanding valves (SEV) Evolut R/PRO/PRO+ (Medtronic) in valve-in-valve TAVR. METHODS: Patients with a failed small (≤23 mm) surgical valve undergoing valve-in-valve TAVR were randomized to receive a SEV or a BEV. Patients had a clinical and valve hemodynamic (Doppler echocardiography) evaluation at 3-year follow-up. Study outcomes were defined according to VARC (Valve Academic Research Consortium)-2/VARC-3 criteria. Intended performance of the valve was defined as mean gradient P P =0.002), and larger indexed effective orifice area (BEV: 0.69±0.27 versus SEV: 0.93±0.32 cm 2 /m 2 ; P =0.002). The rate of moderate aortic regurgitation was 0% in the BEV group versus 2.9% in the SEV group ( P =0.582). Functional status and quality of life improved similarly in both groups. No differences were observed in the composite end point of death, stroke, or heart failure–related hospitalization (BEV: 32.6% versus SEV: 25.5%; P =0.489). Mortality was also not statistically different between groups (BEV: 23.3% versus SEV: 15.7%; P =0.375). No significant differences were observed in other adverse events. CONCLUSIONS: In patients undergoing valve-in-valve TAVR for failed small aortic bioprostheses, SEV demonstrated a superior valve hemodynamic performance at 3-year follow-up, with similar clinical outcomes and functional improvement compared with BEV. REGISTRATION: URL: https://www.clinicaltrials.gov ; Unique identifier: NCT03520101.


  • Open Access

    Late arrhythmic burden in patients with left bundle branch block after TAVR with the Evolut valve

    by Silvia Mas-Peiro, Thibault Lhermusier, Marina Urena, Luis Nombela-Franco, Victoria Vilalta, Antonio Muñoz-Garcia, Ignacio Amat-Santos, Felipe Atienza, Neal Kleiman, Chekrallah Chamandi, et al.

    Aims: Arrhythmic burden after discharge in patients with new-onset persistent left bundle branch block (NOP-LBBB) following transcatheter aortic valve replacement (TAVR) with Evolut devices remains largely unknown. The aim of this study is to assess the incidence and type of arrhythmias at 2-year follow-up in patients with NOP-LBBB post-TAVR. Methods and results: This is a prospective multicentre study including 88 patients with LBBB persisting for ≥3 days post-implantation. Before discharge, an implantable loop recorder (REVEAL XT/LINQ) was implanted; patients had continuous monitoring for 2 years. Arrhythmic events were adjudicated in a central core lab. Of the arrhythmic events, 411 were detected in 58 patients [65.9%; 2 (1–4) events per patient]. Symptoms were reported in 12/58 (20.7%), and therapy was changed in 25/58 (43.1%). There were 101 bradyarrhythmic events in 33 patients [35 high-grade atrioventricular block (HAVB) and 66 severe bradycardia]. The HAVB incidence was higher in the early (4-week) phase and remained stable over time, whereas severe bradycardia increased after 1 year. Permanent pacemaker was required in 11 (12.5%) patients (6.8% and 5.7% in the first and second year, respectively). There were 310 tachyarrhythmic events in 29 patients (120 AF/AFL, 111 AT, 72 SVT, 6 NSVT, and 1 VT); its incidence decreased throughout the 2 years. New AF/AFL episodes occurred in 20/69 patients [29%; symptomatic in 2/20 (10%)]. Conclusion: Patients with NOP-LBBB post-TAVR with Evolut devices exhibited a high burden of late arrhythmias, with events occurring in two-thirds of patients and leading to treatment changes in about half of them. These data should inform future studies on cardiac monitoring devices for follow-up and treatment optimization in this challenging population.


  • Validation of the Valve Academic Research Consortium High Bleeding Risk Definition in Patients Undergoing TAVR

    by Marisa Avvedimento, Pedro Cepas-Guillén, Julien Ternacle, Marina Urena, Alberto Alperi, Asim Cheema, Gabriela Veiga-Fernandez, Luis Nombela-Franco, Victoria Vilalta, Giovanni Esposito, et al.

    BACKGROUND: The Valve Academic Research Consortium for High Bleeding Risk (VARC-HBR) has recently introduced a consensus document that outlines risk factors to identify high bleeding risk in patients undergoing transcatheter aortic valve replacement. The objective of the present study was to evaluate the prevalence and predictive value of the VARC-HBR definition in a contemporary, large-scale transcatheter aortic valve replacement population. METHODS: Multicenter study including 10 449 patients undergoing transcatheter aortic valve replacement. Based on consensus, 21 clinical and laboratory criteria were identified and classified as major or minor. Patients were stratified as at low, moderate, high, and very high bleeding risk according to the VARC-HBR definition. The primary end point was the rate of Bleeding Academic Research Consortium type 3 or 5 bleeding at 1 year, defined as the composite of periprocedural (within 30 days) or late (after 30 days) bleeding. RESULTS: Patients with at least 1 VARC-HBR criterion (n=9267, 88.7%) had a higher risk of Bleeding Academic Research Consortium 3 or 5 bleeding, proportional to the severity of risk assessment (10.8%, 16.1%, and 24.6% for moderate, high, and very-high-risk groups, respectively). However, a comparable rate of bleeding events was observed in the low-risk and moderate-risk groups. The area under receiver operating characteristic curve was 0.58. Patients with VARC-HBR criteria also exhibited a gradual increase in 1-year all-cause mortality, with an up to 2-fold increased mortality risk for high and very-high-risk groups (hazard ratio, 1.33 [95% CI, 1.04–1.70] and 1.97 [95% CI, 1.53–2.53], respectively). CONCLUSIONS: The VARC-HBR consensus offered a pragmatic approach to guide bleeding risk stratification in transcatheter aortic valve replacement. The results of the present study would support the predictive validity of the new definition and promote its application in clinical practice to minimize bleeding risk and improve patient outcomes.


  • Open Access

    Experience with the ACURATE neo and neo2 transcatheter aortic valves in Spain. The PRECISA (PRospective Evaluation Complementing Investigation with ACURATE devices) registry

    by Daniel Tébar, Xavier Carrillo, Bruno García del Blanco, Joan Antoni Gómez‐Hospital, Luis Nombela, Eduardo Molina, Guillermo Galeote, Victoria Vilalta, Vicenc Serra‐García, Guillem Muntané Carol, et al.

    Background: Previous studies have documented a high rate of implantation success with the ACURATE neo2 valve, as well as a reduction in paravalvular leak (PVL) compared to its predecessor, the ACURATE neo. However, there are no studies that have reviewed and compared the long‐term clinical and hemodynamic outcomes of these patients.Aims: This study aimed to evaluate the results of the ACURATE neo transcatheter aortic valve in a real‐world context, and to compare the results of the outcomes of both generations of this device (ACURATE neo and ACURATE neo2), with a specific focus on procedural success, safety, and long‐term effectiveness.Methods: A prospective study including all consecutive patients treated with the ACURATE neo device in seven hospitals was conducted (Clinical Trials Identification Number: NCT03846557). The primary endpoint consisted of a composite of adverse events, including mortality, aortic insufficiency, and other procedural complications. As the second‐generation device (ACURATE neo2) replaced the ACURATE neo during the study period, hemodynamic and clinical results before admission, at 30 days, and at 1 year of follow‐up were compared between the two generations.Results: A total of 296 patients underwent transcatheter aortic valve implantation with the ACURATE device, with 178 patients receiving the ACURATE neo and 118 patients receiving the ACURATE neo2. In the overall population, the absence of device success occurred in 14.5%. The primary reason for the absence of device success was the presence of para‐valvular regurgitation ≥ 2. There were no instances of coronary occlusions, valve embolization, annulus rupture, or procedural deaths. ACURATE neo2 was associated with a significantly higher device success rate (91.7% vs. 82%, p = 0.04), primarily due to a significantly lower rate of para‐valvular regurgitation, which remained significant at 1 year.Conclusion: The use of ACURATE neo and neo2 transcatheter aortic valves is associated with satisfactory clinical results and an extremely low rate of complications. The ACURATE neo2 enables a significantly higher device success rate, primarily attributed to a significant reduction in the rate of PVL.


  • Transcatheter mitral valve leak closure with left atrial appendage closure device: kill two birds with one stone

    by Victoria Vilalta, Eduard Fernández-Nofrerias, Xavier Carrillo, Victoria Delgado

    Victoria Vilalta, MD, PhD, Eduard Fernández-Nofrerias, MD, PhD, Xavier Carrillo, MD, PhD, Victoria Delgado, MD; Transcatheter Mitral valve leak closure with Lef

  • Optimal Degree of Balloon-Expandable Transcatheter Valve Oversizing in Patients With Borderline Aortic Annulus Measurements: Insights From a Multicenter Real-World Experience

    by Vassili Panagides, Asim N. Cheema, Marina Urena, Luis Nombela-Franco, Gabriela Veiga-Fernandez, Victoria Vilalta, Ander Regueiro, David Del Val, Lluis Asmarats, Maria del Trigo, et al.

    Background: The potential benefit of using larger or smaller transcatheter heart valves (THV) in patients with borderline aortic annulus measurement (BAM) remains uncertain. The objective of this study was to evaluate the clinical outcomes associated with the selection of larger or smaller THV in the context of BAM. Methods: This was a multicenter observational study including patients who underwent transcatheter aortic valve replacement with the SAPIEN 3 or SAPIEN 3 Ultra-valve systems (Edwards Lifesciences, Irvine, CA) from April 2014 to June 2021. BAM was defined according to the manufacturer sizing chart and included the following annulus areas: 314 to 346, 400 to 430, 500 to 546 mm 2 . A 1:1 propensity score matching was used to compare outcomes of patients with larger or smaller THV. Results: From a total of 2467 patients, BAM was identified in 852 patients (34.5%). A larger and smaller THV was selected in 338 (39.7%) and 514 patients (60.3%) patients, respectively. The choice of a larger THV was associated (before and after propensity matching) with a higher risk of new-onset left bundle branch block (HR, 2.25 [95% CI, 1.39–3.65; P =0.001) and permanent pacemaker implantation (HR, 1.86 [95% CI, 1.11–3.09]; P =0.016) without any impact on gradients or the risk of moderate or severe paravalvular regurgitation at discharge (HR, 0.78 [95% CI, 0.41–1.45]; P =0.427). The risk of periprocedural complications such as aortic rupture and tamponade was low (<1%) and similar between groups. Conclusions: In patient with BAM, selecting a larger SAPIEN 3/Ultra THV increased the risk of conduction disturbances without any benefit on valve hemodynamics and clinical outcomes.