Joel Segal
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Joel Segal has a total of 138 co-authors. Here are the top co-authors by number of shared publications:
- Svetan Ratchev
Institute for Advanced Manufacturing, University of Nottingham, Nottingham, UK
16 shared publications - Shukri Afazov
Nottingham Trent University
7 shared publications - Felicity Rosamari A.J. Rose
School of Pharmacy, Biodiscovery Institute, University of Nottingham, Nottingham, UK
5 shared publications - Andrew Gleadall
Wolfson School of Mechanical and Manufacturing Engineering, Loughborough University, Loughborough LE11 3TU, UK
4 shared publications - David M. Grant
Advanced Materials Research Group, Faculty of Engineering, University of Nottingham, Nottingham, United Kingdom
4 shared publications - Ifty Ahmed
University of Nottingham
4 shared publications
Latest Publications
- Open Access
- 10 October 2026
- Published by Elsevier in European Polymer Journal
- Vol. 260
Bio-based jasmine lactone homo- and co-oligomers for stereolithographic additive manufacturing
- 10 October 2026
- Published by Elsevier in European Polymer Journal
- Vol. 260
Open AccessBio-based jasmine lactone homo- and co-oligomers for stereolithographic additive manufacturing
- Open Access
- 23 June 2025
- Published by Royal Society of Chemistry (RSC) in Faraday Discussions
- Vol. 262, 123-137
Polyglycerol resin towards sustainable 3D-printing
This work explores the use of (meth)acrylated polyglycerols in stereolithography (SLA), examining printability optimisation and biocompatibility. It also investigates greener resin alternatives via anhydride ring-opening and initial curability tests.
- 23 June 2025
- Published by Royal Society of Chemistry (RSC) in Faraday Discussions
- Vol. 262, 123-137
Open AccessPolyglycerol resin towards sustainable 3D-printing
This work explores the use of (meth)acrylated polyglycerols in stereolithography (SLA), examining printability optimisation and biocompatibility. It also investigates greener resin alternatives via anhydride ring-opening and initial curability tests.
- 1 January 2022
- Published by Elsevier in Journal of Materials Processing Technology
- Vol. 299
Magnetic manipulation in directed energy deposition using a programmable solenoid
- 1 January 2022
- Published by Elsevier in Journal of Materials Processing Technology
- Vol. 299
Magnetic manipulation in directed energy deposition using a programmable solenoid
- Open Access
- 2 April 2020
- Published by Royal Society of Chemistry (RSC) in Biomaterials Science
- Vol. 8 (9) , 2611-2626
The electrospinning of a thermo-responsive polymer with peptide conjugates for phenotype support and extracellular matrix production of therapeutically relevant mammalian cells
The fabrication and application of a biocompatible peptide conjugated thermo-responsive fibrous scaffolds for cellular phenotype support and enzymatic-free passaging of mammalian cells.
- 2 April 2020
- Published by Royal Society of Chemistry (RSC) in Biomaterials Science
- Vol. 8 (9) , 2611-2626
Open AccessThe electrospinning of a thermo-responsive polymer with peptide conjugates for phenotype support and extracellular matrix production of therapeutically relevant mammalian cells
The fabrication and application of a biocompatible peptide conjugated thermo-responsive fibrous scaffolds for cellular phenotype support and enzymatic-free passaging of mammalian cells.
- 1 July 2019
- Published by Elsevier in European Journal of Pharmaceutics and Biopharmaceutics
- Vol. 140, 121-140
Expanding the applications of microneedles in dermatology
- 1 July 2019
- Published by Elsevier in European Journal of Pharmaceutics and Biopharmaceutics
- Vol. 140, 121-140
Expanding the applications of microneedles in dermatology
- Open Access
- 1 November 2018
- Published by Wiley in Journal of Biomedical Materials Research Part B: Applied Biomaterials
- Vol. 107 (5) , 1711-1721
Design and fabrication of a hybrid alginate hydrogel/poly(ε‐caprolactone) mold for auricular cartilage reconstruction
The aim of this study was to design and manufacture an easily assembled cartilage implant model for auricular reconstruction. First, the printing accuracy and mechanical properties of 3D‐printed poly‐ε‐caprolactone (PCL) scaffolds with varying porosities were determined to assess overall material properties. Next, the applicability of alginate as cell carrier for the cartilage implant model was determined. Using the optimal outcomes of both experiments (in terms of (bio)mechanical properties, cell survival, neocartilage formation, and printing accuracy), a hybrid auricular implant model was developed. PCL scaffolds with 600 μm distances between strands exhibited the best mechanical properties and most optimal printing quality for further exploration. In alginate, chondrocytes displayed high cell survival (~83% after 21 days) and produced cartilage‐like matrix in vitro. Alginate beads cultured in proliferation medium exhibited slightly higher compressive moduli (6 kPa) compared to beads cultured in chondrogenic medium (3.5 kPa, p > .05). The final auricular mold could be printed with 300 μm pores and high fidelity, and the injected chondrocytes survived the culture period of 21 days. The presented hybrid auricular mold appears to be an adequate model for cartilage tissue engineering and may provide a novel approach to auricular cartilage regeneration for facial reconstruction. © 2018 Wiley Periodicals, Inc. J Biomed Mater Res Part B: Appl Biomater 107B: 1711–1721, 2019.
- 1 November 2018
- Published by Wiley in Journal of Biomedical Materials Research Part B: Applied Biomaterials
- Vol. 107 (5) , 1711-1721
Open AccessDesign and fabrication of a hybrid alginate hydrogel/poly(ε‐caprolactone) mold for auricular cartilage reconstruction
The aim of this study was to design and manufacture an easily assembled cartilage implant model for auricular reconstruction. First, the printing accuracy and mechanical properties of 3D‐printed poly‐ε‐caprolactone (PCL) scaffolds with varying porosities were determined to assess overall material properties. Next, the applicability of alginate as cell carrier for the cartilage implant model was determined. Using the optimal outcomes of both experiments (in terms of (bio)mechanical properties, cell survival, neocartilage formation, and printing accuracy), a hybrid auricular implant model was developed. PCL scaffolds with 600 μm distances between strands exhibited the best mechanical properties and most optimal printing quality for further exploration. In alginate, chondrocytes displayed high cell survival (~83% after 21 days) and produced cartilage‐like matrix in vitro. Alginate beads cultured in proliferation medium exhibited slightly higher compressive moduli (6 kPa) compared to beads cultured in chondrogenic medium (3.5 kPa, p > .05). The final auricular mold could be printed with 300 μm pores and high fidelity, and the injected chondrocytes survived the culture period of 21 days. The presented hybrid auricular mold appears to be an adequate model for cartilage tissue engineering and may provide a novel approach to auricular cartilage regeneration for facial reconstruction. © 2018 Wiley Periodicals, Inc. J Biomed Mater Res Part B: Appl Biomater 107B: 1711–1721, 2019.
- Open Access
- 3 July 2018
- Published by Oxford University Press (OUP) in Burns & Trauma
- Vol. 6 (1) , 19
Review of additive manufactured tissue engineering scaffolds: relationship between geometry and performance
Material extrusion additive manufacturing has rapidly grown in use for tissue engineering research since its adoption in the year 2000. It has enabled researchers to produce scaffolds with intricate porous geometries that were not feasible with traditional manufacturing processes. Researchers can control the structural geometry through a wide range of customisable printing parameters and design choices including material, print path, temperature, and many other process parameters. Currently, the impact of these choices is not fully understood. This review focuses on how the position and orientation of extruded filaments, which sometimes referred to as the print path, lay-down pattern, or simply “scaffold design”, affect scaffold properties and biological performance. By analysing trends across multiple studies, new understanding was developed on how filament position affects mechanical properties. Biological performance was also found to be affected by filament position, but a lack of consensus between studies indicates a need for further research and understanding. In most research studies, scaffold design was dictated by capabilities of additive manufacturing software rather than free-form design of structural geometry optimised for biological requirements. There is scope for much greater application of engineering innovation to additive manufacture novel geometries. To achieve this, better understanding of biological requirements is needed to enable the effective specification of ideal scaffold geometries.
- 3 July 2018
- Published by Oxford University Press (OUP) in Burns & Trauma
- Vol. 6 (1) , 19
Open AccessReview of additive manufactured tissue engineering scaffolds: relationship between geometry and performance
Material extrusion additive manufacturing has rapidly grown in use for tissue engineering research since its adoption in the year 2000. It has enabled researchers to produce scaffolds with intricate porous geometries that were not feasible with traditional manufacturing processes. Researchers can control the structural geometry through a wide range of customisable printing parameters and design choices including material, print path, temperature, and many other process parameters. Currently, the impact of these choices is not fully understood. This review focuses on how the position and orientation of extruded filaments, which sometimes referred to as the print path, lay-down pattern, or simply “scaffold design”, affect scaffold properties and biological performance. By analysing trends across multiple studies, new understanding was developed on how filament position affects mechanical properties. Biological performance was also found to be affected by filament position, but a lack of consensus between studies indicates a need for further research and understanding. In most research studies, scaffold design was dictated by capabilities of additive manufacturing software rather than free-form design of structural geometry optimised for biological requirements. There is scope for much greater application of engineering innovation to additive manufacture novel geometries. To achieve this, better understanding of biological requirements is needed to enable the effective specification of ideal scaffold geometries.
- Open Access
- 1 May 2018
- Published by Elsevier in Additive Manufacturing
- Vol. 21, 605-618
VOLCO: A predictive model for 3D printed microarchitecture
- 1 May 2018
- Published by Elsevier in Additive Manufacturing
- Vol. 21, 605-618
Open AccessVOLCO: A predictive model for 3D printed microarchitecture
- 5 March 2018
- Published by American Chemical Society (ACS) in Molecular Pharmaceutics
- Vol. 15 (4) , 1578-1586
Self-Assembling Benzothiazole-Based Gelators: A Mechanistic Understanding of in Vitro Bioactivation and Gelation
Low molecular weight gelators (LMWGs) of chemotherapeutic drugs represent a valid alternative to the existing polymer-based formulations used for targeted delivery of anticancer drugs. Herein we report the design and development of novel self-assembling gelators of the antitumor benzothiazole 5F 203 (1). Two different types of derivatives of 1 were synthesized, formed by an amide (2) and a carbamate (3a–3d) linker, respectively, which showed potent in vitro antitumor activity against MCF-7 mammary and IGROV-1 ovarian carcinoma cells. In contrast, MRC-5 fibroblasts were inherently resistant to the above derivatives (GI50 > 10 μM), thus revealing stark selectivity against the malignant cell lines over the nontransformed fibroblasts. Western blots assays demonstrated induction of CYP1A1 by 1 and its derivatives only in sensitive malignant cells (MCF-7), corroborating conservation of a CYP1A1-mediated mechanism of action. The ability to form stable gels under relatively high strains was supported by rheological tests; in addition, their inner morphology was characterized as possessing a crossed-linked nanostructure, with the formation of thick aggregates with variable widths between 1100 and 400 nm and lengths from 8 to 32 μm. Finally, in vitro dissolution studies proved the ability of hydrogel 2 to release 48% of 2 within 80 h, therefore demonstrating its ability to act as a platform for localized delivery.
- 5 March 2018
- Published by American Chemical Society (ACS) in Molecular Pharmaceutics
- Vol. 15 (4) , 1578-1586
Self-Assembling Benzothiazole-Based Gelators: A Mechanistic Understanding of in Vitro Bioactivation and Gelation
Low molecular weight gelators (LMWGs) of chemotherapeutic drugs represent a valid alternative to the existing polymer-based formulations used for targeted delivery of anticancer drugs. Herein we report the design and development of novel self-assembling gelators of the antitumor benzothiazole 5F 203 (1). Two different types of derivatives of 1 were synthesized, formed by an amide (2) and a carbamate (3a–3d) linker, respectively, which showed potent in vitro antitumor activity against MCF-7 mammary and IGROV-1 ovarian carcinoma cells. In contrast, MRC-5 fibroblasts were inherently resistant to the above derivatives (GI50 > 10 μM), thus revealing stark selectivity against the malignant cell lines over the nontransformed fibroblasts. Western blots assays demonstrated induction of CYP1A1 by 1 and its derivatives only in sensitive malignant cells (MCF-7), corroborating conservation of a CYP1A1-mediated mechanism of action. The ability to form stable gels under relatively high strains was supported by rheological tests; in addition, their inner morphology was characterized as possessing a crossed-linked nanostructure, with the formation of thick aggregates with variable widths between 1100 and 400 nm and lengths from 8 to 32 μm. Finally, in vitro dissolution studies proved the ability of hydrogel 2 to release 48% of 2 within 80 h, therefore demonstrating its ability to act as a platform for localized delivery.
- Open Access
- 25 September 2017
- Published by IOP Publishing in Biomedical Materials
- Vol. 12 (5) , 055009
A design of experiments approach to identify the influencing parameters that determine poly-D,L-lactic acid (PDLLA) electrospun scaffold morphologies
Electrospun fibrous materials have increasing applications in regenerative medicine due to the similarity of fibre constructs to the morphology of certain extracellular matrices. Although experimentally the electrospinning method is relatively simple, at the theoretical level the interactions between process parameters and their influence on the fibre morphology is not yet fully understood. Here, we hypothesised that a design of experiments (DoE) model could determine combinations of process parameters that result in significant effects on poly-D,L-lactic acid (PDLLA) fibre morphology. The process parameters used in this study were applied voltage, needle-to-collector distance, flow rate and polymer concentration. Data obtained for mean fibre diameter, standard deviation (SD) of the fibre diameter (measure of fibre morphology) and presence of 'beading' on the fibres (beads per μm2) were evaluated as a measure of PDLLA fibre morphology. Uniform fibres occurred at SDs of ≤500 nm, 'beads-on-string' morphologies were apparent between ±500 and 1300 nm and large beads were observed at ±1300-1800 nm respectively. Mean fibre diameter was significantly influenced by the applied voltage and interaction between flow rate and polymer concentration. Fibre morphology was mainly influenced by the polymer concentration, while bead distribution was significantly influenced by the polymer concentration as well as the flow rate. The resultant DoE model regression equations were tested and considered suitable for the prediction of parameters combinations needed for desired PDLLA fibre diameter and additionally provided information regarding the expected fibre morphology.
- 25 September 2017
- Published by IOP Publishing in Biomedical Materials
- Vol. 12 (5) , 055009
Open AccessA design of experiments approach to identify the influencing parameters that determine poly-D,L-lactic acid (PDLLA) electrospun scaffold morphologies
Electrospun fibrous materials have increasing applications in regenerative medicine due to the similarity of fibre constructs to the morphology of certain extracellular matrices. Although experimentally the electrospinning method is relatively simple, at the theoretical level the interactions between process parameters and their influence on the fibre morphology is not yet fully understood. Here, we hypothesised that a design of experiments (DoE) model could determine combinations of process parameters that result in significant effects on poly-D,L-lactic acid (PDLLA) fibre morphology. The process parameters used in this study were applied voltage, needle-to-collector distance, flow rate and polymer concentration. Data obtained for mean fibre diameter, standard deviation (SD) of the fibre diameter (measure of fibre morphology) and presence of 'beading' on the fibres (beads per μm2) were evaluated as a measure of PDLLA fibre morphology. Uniform fibres occurred at SDs of ≤500 nm, 'beads-on-string' morphologies were apparent between ±500 and 1300 nm and large beads were observed at ±1300-1800 nm respectively. Mean fibre diameter was significantly influenced by the applied voltage and interaction between flow rate and polymer concentration. Fibre morphology was mainly influenced by the polymer concentration, while bead distribution was significantly influenced by the polymer concentration as well as the flow rate. The resultant DoE model regression equations were tested and considered suitable for the prediction of parameters combinations needed for desired PDLLA fibre diameter and additionally provided information regarding the expected fibre morphology.