Rachid El Bachtiri
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Rachid El Bachtiri has a total of 29 co-authors. Here are the top co-authors by number of shared publications:
Abdelaziz Fri
LESSI Lab, FSDM Faculty. USMBA University
4 shared publicationsTariq Riouch
Student in Sidi Mohamed Ben Abdallah University, Faculty of Sciences Dhar Mahraz and ESTF, Laboratory of Electronics, Computer Systems and Signals (LESSI), Research Team Electrical Engineering, Power Electronics and Renewable Energy (REPEER)
4 shared publicationsAbdelaziz El Ghzizal
LESSI Lab, FSDM Faculty. REEPER group, USMBA University
3 shared publicationsE. Matagne
3 shared publications- Naoufal El Youssfi
Electrical Engineering Department, Royal School of Aeronautics, Marrakech, Morocco
3 shared publications F. Labrique
2 shared publications
Latest Publications
- Open Access
- 1 December 2025
- Published by Institute of Advanced Engineering and Science in International Journal of Power Electronics and Drive Systems (IJPEDS)
- Vol. 16 (4) , 2464-2475
Performance analysis of a cascaded dual full bridges 5, 7, and 9 levels inverter: experimental validation
Cascaded full-bridge inverter is a suitable topology for grid-connected applications due to its ability to generate an output voltage waveform that closely resembles a sine wave, resulting in lower total harmonic distortion (THD) factors. This article proposes the use of the selective harmonic elimination (SHE) technique to produce a 5-level voltage using a symmetrical inverter and 7 and 9-level voltage using an asymmetrical inverter composed of only two full bridges loaded by an RL circuit of 51.4 Ω and 200 mH. The study primarily focuses on analysing the impact of the number of levels on the power quality of the inverter. This includes investigating the effects of the fundamental magnitude on the produced power, as well as measuring losses in the inverter, power factor, THD factor, and fundamental magnitude for each level configuration. The study demonstrates that asymmetrical MLIs lower THD (10.9% vs. 16.7%) and increasing voltage levels enhance waveform quality but slightly reduce the fundamental voltage magnitude, impacting AC power output. The simulation analysis has been conducted using the PSIM environment, and the results have been validated through experimental measurements.
- 1 December 2025
- Published by Institute of Advanced Engineering and Science in International Journal of Power Electronics and Drive Systems (IJPEDS)
- Vol. 16 (4) , 2464-2475
Open AccessPerformance analysis of a cascaded dual full bridges 5, 7, and 9 levels inverter: experimental validation
Cascaded full-bridge inverter is a suitable topology for grid-connected applications due to its ability to generate an output voltage waveform that closely resembles a sine wave, resulting in lower total harmonic distortion (THD) factors. This article proposes the use of the selective harmonic elimination (SHE) technique to produce a 5-level voltage using a symmetrical inverter and 7 and 9-level voltage using an asymmetrical inverter composed of only two full bridges loaded by an RL circuit of 51.4 Ω and 200 mH. The study primarily focuses on analysing the impact of the number of levels on the power quality of the inverter. This includes investigating the effects of the fundamental magnitude on the produced power, as well as measuring losses in the inverter, power factor, THD factor, and fundamental magnitude for each level configuration. The study demonstrates that asymmetrical MLIs lower THD (10.9% vs. 16.7%) and increasing voltage levels enhance waveform quality but slightly reduce the fundamental voltage magnitude, impacting AC power output. The simulation analysis has been conducted using the PSIM environment, and the results have been validated through experimental measurements.
- Open Access
- 27 April 2021
- Published by Inderscience Publishers in International Journal of Digital Signals and Smart Systems
- Vol. 5 (2) , 105
T-S fuzzy observers design and actuator fault tolerant control applied to vehicle lateral dynamics
In this study, we present a method for estimating actuator faults along with a technique of fault-tolerant control (FTC) based on fuzzy observers for continuous Takagi-Sugeno (T-S) fuzzy models, which are affected by modelling disturbances and actuator faults. The stability analysis is based on the quadratic function of Lyapunov and resolving a convex set of linear matrix inequalities (LMIs). The purpose is to ensure the asymptotic stability of the system states and to compensate for the impact of disturbances and actuator faults. Ultimately, numerical simulations on the vehicle lateral dynamics model exemplify the efficiency of the proposed control and the fuzzy observers' design procedure.
- 27 April 2021
- Published by Inderscience Publishers in International Journal of Digital Signals and Smart Systems
- Vol. 5 (2) , 105
Open AccessT-S fuzzy observers design and actuator fault tolerant control applied to vehicle lateral dynamics
In this study, we present a method for estimating actuator faults along with a technique of fault-tolerant control (FTC) based on fuzzy observers for continuous Takagi-Sugeno (T-S) fuzzy models, which are affected by modelling disturbances and actuator faults. The stability analysis is based on the quadratic function of Lyapunov and resolving a convex set of linear matrix inequalities (LMIs). The purpose is to ensure the asymptotic stability of the system states and to compensate for the impact of disturbances and actuator faults. Ultimately, numerical simulations on the vehicle lateral dynamics model exemplify the efficiency of the proposed control and the fuzzy observers' design procedure.
- 1 January 2019
- Published by AIP Publishing in AIP Conference Proceedings
- Vol. 2074, 020027
Actuator fault estimation and fault tolerant control for vehicle lateral dynamics
- 1 January 2019
- Published by AIP Publishing in AIP Conference Proceedings
- Vol. 2074, 020027
Actuator fault estimation and fault tolerant control for vehicle lateral dynamics
- Open Access
- 1 December 2018
- Published by Institute of Advanced Engineering and Science in International Journal of Power Electronics and Drive Systems (IJPEDS)
- Vol. 9 (4) , 1774-1783
A Multicarrier PWM Technique for Five Level Inverter Connected to the Grid
In this paper, a three-phase multilevel cascaded H-bridge inverter is developed for injecting renewable power energy into the grid through a filter. The main contribution of this work is to reduce the total harmonic distortion (THD) by using a passive filter and to enhance the output voltages by adopting a multicarrier pulse width modulation (MCPWM). The simulation results affirm a good performance of the proposed multicarrier PWM control using a three-phase five-level inverter. The proposed inverter is tested as well as the THD and the spectral analysis of the output voltage are calculated using Simulink/Matlab software.
- 1 December 2018
- Published by Institute of Advanced Engineering and Science in International Journal of Power Electronics and Drive Systems (IJPEDS)
- Vol. 9 (4) , 1774-1783
Open AccessA Multicarrier PWM Technique for Five Level Inverter Connected to the Grid
In this paper, a three-phase multilevel cascaded H-bridge inverter is developed for injecting renewable power energy into the grid through a filter. The main contribution of this work is to reduce the total harmonic distortion (THD) by using a passive filter and to enhance the output voltages by adopting a multicarrier pulse width modulation (MCPWM). The simulation results affirm a good performance of the proposed multicarrier PWM control using a three-phase five-level inverter. The proposed inverter is tested as well as the THD and the spectral analysis of the output voltage are calculated using Simulink/Matlab software.
- 1 June 2018
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 861-866
Fuzzy Sliding-Mode Observer for Lateral Dynamics of Vehicles with Consideration of Roll Motion
This paper focuses on the methodology of estimating dynamic states of the vehicle, by a sliding-mode observer (SMO). The vehicle is represented by the fuzzy model of Takagi Sugeno (TS). The main contribution of this article is the development of a robust observer with the synthesis of sufficient stability conditions of this observer. This representation is used to take into account the non-linearities of the lateral forces. The stability of the fuzzy observer is given by the Lyapunov approach; the stability conditions of this observer are expressed in terms of linear matrix inequalities (LMI). The simulation results show the effectiveness of the proposed observer in estimating the states of the vehicle dynamics.
- 1 June 2018
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 861-866
Fuzzy Sliding-Mode Observer for Lateral Dynamics of Vehicles with Consideration of Roll Motion
This paper focuses on the methodology of estimating dynamic states of the vehicle, by a sliding-mode observer (SMO). The vehicle is represented by the fuzzy model of Takagi Sugeno (TS). The main contribution of this article is the development of a robust observer with the synthesis of sufficient stability conditions of this observer. This representation is used to take into account the non-linearities of the lateral forces. The stability of the fuzzy observer is given by the Lyapunov approach; the stability conditions of this observer are expressed in terms of linear matrix inequalities (LMI). The simulation results show the effectiveness of the proposed observer in estimating the states of the vehicle dynamics.
- 1 December 2017
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-6
A Bank of Kalman Filters for Current Sensors Faults Detection and Isolation of DFIG for Wind Turbine
This paper presents a model based Fault diagnosis approach. This approach is based on a bank of Kalman filters. These filters are structured according to the Dedicated Observer Scheme (DOS)., for detecting and isolating multiple and simultaneous current sensors faults of a doubly fed induction generator (DFIG) widely used in variable speed wind turbines. Then., a linear varying parameter model of DFIG is established and the faults diagnosis procedure is implemented. The DFIG model design and the model-based Fault Detection and Isolation (FDI) approach are performed in the Matlab/Simulink environment.
- 1 December 2017
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-6
A Bank of Kalman Filters for Current Sensors Faults Detection and Isolation of DFIG for Wind Turbine
This paper presents a model based Fault diagnosis approach. This approach is based on a bank of Kalman filters. These filters are structured according to the Dedicated Observer Scheme (DOS)., for detecting and isolating multiple and simultaneous current sensors faults of a doubly fed induction generator (DFIG) widely used in variable speed wind turbines. Then., a linear varying parameter model of DFIG is established and the faults diagnosis procedure is implemented. The DFIG model design and the model-based Fault Detection and Isolation (FDI) approach are performed in the Matlab/Simulink environment.
- Open Access
- 14 December 2016
- Published by Springer Nature
- p. 89-101
A Comparative Study Between Photovoltaic Pumping Systems Using a Permanent Magnet DC Motor and an Induction Motor
- 14 December 2016
- Published by Springer Nature
- p. 89-101
Open AccessA Comparative Study Between Photovoltaic Pumping Systems Using a Permanent Magnet DC Motor and an Induction Motor
- 1 March 2016
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-6
A comparison between two filters for PV inverter controlled to eliminate firsts harmonics
In this paper, a five-levels inverter is developed and used for injecting renewable power into the grid. To reduce harmonic distortion and increase the quality of the energy supplied by the PV system, we have used two filters. The goal is the elimination of the 3rd and the 5th harmonic by an adequate control applied to the five-levels inverter, also eliminate the 7th harmonics by an appropriate resonant filter. In a second time, we have used a low-pass filter for testing its performance comparatively to the above one. We calculated in different cases, spectrum and Total Harmonic Distortion (THD), both quantities necessary to judge the quality of the inverter output voltage. To validate our result we have used simulations with Psim.
- 1 March 2016
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-6
A comparison between two filters for PV inverter controlled to eliminate firsts harmonics
In this paper, a five-levels inverter is developed and used for injecting renewable power into the grid. To reduce harmonic distortion and increase the quality of the energy supplied by the PV system, we have used two filters. The goal is the elimination of the 3rd and the 5th harmonic by an adequate control applied to the five-levels inverter, also eliminate the 7th harmonics by an appropriate resonant filter. In a second time, we have used a low-pass filter for testing its performance comparatively to the above one. We calculated in different cases, spectrum and Total Harmonic Distortion (THD), both quantities necessary to judge the quality of the inverter output voltage. To validate our result we have used simulations with Psim.
- 31 January 2016
- Published by Praise Worthy Prize in International Review of Automatic Control (IREACO)
- Vol. 9 (1) , 11
Improved MPPT Algorithm for Controlling a PV System Grid Connected for Rapid Changes of Irradiance
Improved MPPT Algorithm for Controlling a PV System Grid Connected for Rapid Changes of Irradiance
- 31 January 2016
- Published by Praise Worthy Prize in International Review of Automatic Control (IREACO)
- Vol. 9 (1) , 11
Improved MPPT Algorithm for Controlling a PV System Grid Connected for Rapid Changes of Irradiance
Improved MPPT Algorithm for Controlling a PV System Grid Connected for Rapid Changes of Irradiance